Cisco 350-601 Practice Test 48
Question 470
An automation team sets a boot order that tries an empty virtual media device before the intended SAN boot target. The observed failure is: misordered or unavailable devices can redirect the host into unintended boot methods. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to configure DHCP reservations to override all firmware boot policy entries.
- The controlled remediation is to correct device priority and target availability, then test normal and fallback boot behavior.
- The controlled remediation is to use only a VLAN tag change to define BIOS boot order.
- The controlled remediation is to delete the working boot medium to reduce boot choices.
Explanation
Correct Answer
B:Validate against boot policy order, effective BIOS settings, device presence and boot logs from the host. A UCS boot policy determines device search order and must reflect provisioned boot media.
Incorrect Answers
A:Configure DHCP reservations to override all firmware boot policy entries. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.
C:Use only a VLAN tag change to define BIOS boot order. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.
D:Delete the working boot medium to reduce boot choices. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.
Question 471
A UCS-X chassis is deployed in Intersight Managed Mode but administrators look for its server configuration only in legacy UCS Manager. Which next step should the data center engineer select?
- Attempt to configure every UCS-X blade only through a classic UCSM service profile.
- Disable the claimed device connection so Intersight cannot receive inventory.
- Use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
- Assume chassis insertion automatically builds LAN and SAN policies.
Explanation
Correct Answer
C:This directly addresses UCS-X IMM profile management because UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. Confirm the change against Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
Incorrect Answers
A:Attempt to configure every UCS-X blade only through a classic UCSM service profile. This is not a valid substitute for the specified fix. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The relevant correction is to use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
B:That option would disable the claimed device connection so Intersight cannot receive inventory, but it addresses a different concern. This directly addresses UCS-X IMM profile management because UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain.
D:Assume chassis insertion automatically builds LAN and SAN policies. This would leave the diagnosed requirement unresolved. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The appropriate action remains to use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
Question 472
A UCS-X chassis is deployed in Intersight Managed Mode but administrators look for its server configuration only in legacy UCS Manager. Which diagnostic record would most strongly confirm the result?
- The rack label without current UCS or Intersight policy associations.
- A management ping that does not verify the required server or adapter function.
- An operator assurance without current logs, component inventory or health faults.
- Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
Explanation
Correct Answer
D:These observations test the actual UCS-X IMM profile management mechanism rather than a superficial management status. UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain.
Incorrect Answers
A:This information cannot independently verify UCS-X IMM profile management. The decisive records instead include Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
B:This information cannot independently verify UCS-X IMM profile management. UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain.
C:This information cannot independently verify UCS-X IMM profile management. An operator assurance without current logs, component inventory or health faults.
Question 473
A UCS-X chassis is deployed in Intersight Managed Mode but administrators look for its server configuration only in legacy UCS Manager. Which platform concept should guide the engineer’s assessment?
- UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain.
- Service profiles can never change effective network identity or firmware behavior.
- Two logical objects always provide resilience even if they share one failed hardware path.
- A rack server that powers on is automatically configured for every SAN and LAN service.
Explanation
Correct Answer
A:Validation depends on Intersight organization and domain inventory, assigned profiles, policy state and server operational health. This explains why the most appropriate response is to use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
Incorrect Answers
B:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for UCS-X IMM profile management. The applicable technical behavior is that UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. The operator should verify Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
C:Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for UCS-X IMM profile management. The applicable technical behavior is that UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. The operator should verify Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
D:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for UCS-X IMM profile management. The applicable technical behavior is that UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. The operator should verify Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
Question 474
A UCS-X chassis is deployed in Intersight Managed Mode but administrators look for its server configuration only in legacy UCS Manager. Assume an engineer instead chooses to attempt to configure every UCS-X blade only through a classic UCSM service profile. Which root-cause observation follows from that incorrect change?
- Recording chassis health events is what prevents server management.
- Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced.
- Checking effective service-profile bindings caused the original hardware mismatch.
- The underlying fault was caused only by retaining accurate firmware inventory.
Explanation
Correct Answer
B:The proper corrective action is to use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
Incorrect Answers
A:This does not explain the actual UCS-X IMM profile management defect after the shortcut. The meaningful failure is that treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced.
C:This does not explain the actual UCS-X IMM profile management defect after the shortcut. The relevant evidence is Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
D:This does not explain the actual UCS-X IMM profile management defect after the shortcut. The underlying fault was caused only by retaining accurate firmware inventory.
Question 475
A UCS-X chassis is deployed in Intersight Managed Mode but administrators look for its server configuration only in legacy UCS Manager. The observed failure is: treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. Which recovery action addresses the underlying technical fault?
- Disable the claimed device connection so Intersight cannot receive inventory.
- Assume chassis insertion automatically builds LAN and SAN policies.
- Define and assign proper Intersight domain and server policies and validate the server life cycle.
- Attempt to configure every UCS-X blade only through a classic UCSM service profile.
Explanation
Correct Answer
C:UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
A:Disable the claimed device connection so Intersight cannot receive inventory. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.
B:Assume chassis insertion automatically builds LAN and SAN policies. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.
D:Attempt to configure every UCS-X blade only through a classic UCSM service profile. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.
Question 476
A new Intersight-managed compute domain cannot provision an X-Series server because domain and server policies are missing. What is the BEST supported implementation or corrective action?
- On this affected device, the engineer should disable the claimed device connection so Intersight cannot receive inventory.
- On this affected device, the engineer should assume chassis insertion automatically builds LAN and SAN policies.
- On this affected device, the engineer should attempt to configure every UCS-X blade only through a classic UCSM service profile.
- On this affected device, the engineer should use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
Explanation
Correct Answer
D:This directly addresses UCS-X IMM profile management because UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain.
Incorrect Answers
A:Disable the claimed device connection so Intersight cannot receive inventory. The proposed change targets the wrong mechanism or lacks essential validation. UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. Relevant evidence is Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
B:Assume chassis insertion automatically builds LAN and SAN policies. This would leave the diagnosed requirement unresolved. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The appropriate action remains to use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
C:Attempt to configure every UCS-X blade only through a classic UCSM service profile. This is not a valid substitute for the specified fix. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The relevant correction is to use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
Question 477
A new Intersight-managed compute domain cannot provision an X-Series server because domain and server policies are missing. Which evidence BEST verifies the intended technical behavior?
- For this deployment, examine Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
- For this deployment, examine the planned service profile template without checking effective deployed settings.
- For this deployment, examine the rack label without current UCS or Intersight policy associations.
- For this deployment, examine a management ping that does not verify the required server or adapter function.
Explanation
Correct Answer
A:These observations test the actual UCS-X IMM profile management mechanism rather than a superficial management status. They should be checked after use Cisco Intersight to configure the supported UCS-X domain profile, server profile and required policies.
Incorrect Answers
B:This information cannot independently verify UCS-X IMM profile management. The planned service profile template without checking effective deployed settings.
C:This information cannot independently verify UCS-X IMM profile management. The rack label without current UCS or Intersight policy associations.
D:This information cannot independently verify UCS-X IMM profile management. A management ping that does not verify the required server or adapter function.
Question 478
A new Intersight-managed compute domain cannot provision an X-Series server because domain and server policies are missing. Which principle BEST explains why the recommended solution is appropriate?
- For this condition, the applicable principle is that a rack server that powers on is automatically configured for every SAN and LAN service.
- For this condition, the applicable principle is that UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain.
- For this condition, the applicable principle is that service profiles can never change effective network identity or firmware behavior.
- For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.
Explanation
Correct Answer
B:Validation depends on Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
Incorrect Answers
A:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for UCS-X IMM profile management. The applicable technical behavior is that UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. The operator should verify Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
C:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for UCS-X IMM profile management. The applicable technical behavior is that UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. The operator should verify Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
D:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for UCS-X IMM profile management. The applicable technical behavior is that UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. The operator should verify Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
Question 479
A new Intersight-managed compute domain cannot provision an X-Series server because domain and server policies are missing. Assume an engineer instead chooses to attempt to configure every UCS-X blade only through a classic UCSM service profile. What is the MOST significant failure introduced by that shortcut?
- The resulting defect is that the underlying fault was caused only by retaining accurate firmware inventory.
- The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.
- The resulting defect is that treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced.
- The resulting defect is that checking effective service-profile bindings caused the original hardware mismatch.
Explanation
Correct Answer
C:UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual UCS-X IMM profile management defect after the shortcut. In the given case, a new Intersight-managed compute domain cannot provision an X-Series server because domain and server policies are missing.
B:This does not explain the actual UCS-X IMM profile management defect after the shortcut. A controlled failover test itself proves that the previous outage had no cause.
D:This does not explain the actual UCS-X IMM profile management defect after the shortcut. Checking effective service-profile bindings caused the original hardware mismatch.
Question 480
A new Intersight-managed compute domain cannot provision an X-Series server because domain and server policies are missing. The observed failure is: treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. What is the BEST controlled recovery once this failure is recognized?
- The controlled remediation is to assume chassis insertion automatically builds LAN and SAN policies.
- The controlled remediation is to attempt to configure every UCS-X blade only through a classic UCSM service profile.
- The controlled remediation is to disable the claimed device connection so Intersight cannot receive inventory.
- The controlled remediation is to define and assign proper Intersight domain and server policies and validate the server life cycle.
Explanation
Correct Answer
D:UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. Validate against Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
Incorrect Answers
A:Assume chassis insertion automatically builds LAN and SAN policies. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.
B:Attempt to configure every UCS-X blade only through a classic UCSM service profile. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.
C:Disable the claimed device connection so Intersight cannot receive inventory. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.