Cisco 350-601 Practice Test 47
Question 460
A network policy edit would require a blade reboot but the business expects the change to occur only during its approved window. The observed failure is: immediate application without review can interrupt active workloads even when the policy change itself is valid. What should the engineer do to recover and validate the service?
- The controlled remediation is to force every host to reboot at the moment any template is saved.
- The controlled remediation is to disable power management alarms rather than controlling reboot timing.
- The controlled remediation is to assume all UCS changes are nondisruptive because they are policy based.
- The controlled remediation is to use approved user acknowledgment or schedule and verify stable host return after applying changes.
Explanation
Correct Answer
D:This addresses the observable fault while preserving a check of the expected result. UCS maintenance policies control when policy modifications requiring reboot may be applied.
Incorrect Answers
A:Force every host to reboot at the moment any template is saved. This would not reliably restore service after the stated fault. Immediate application without review can interrupt active workloads even when the policy change itself is valid. The controlled recovery is to use approved user acknowledgment or schedule and verify stable host return after applying changes.
B:Disable power management alarms rather than controlling reboot timing. This would not reliably restore service after the stated fault. Immediate application without review can interrupt active workloads even when the policy change itself is valid. The controlled recovery is to use approved user acknowledgment or schedule and verify stable host return after applying changes.
C:Assume all UCS changes are nondisruptive because they are policy based. This would not reliably restore service after the stated fault. Immediate application without review can interrupt active workloads even when the policy change itself is valid. The controlled recovery is to use approved user acknowledgment or schedule and verify stable host return after applying changes.
Question 461
A C-Series host with both local disk and PXE falls into network boot after the configured disk path is missing. Which operator action best meets this technical requirement?
- Validate UCS boot policy priority and ensure the intended boot device or fallback path is available.
- Use only a VLAN tag change to define BIOS boot order.
- Delete the working boot medium to reduce boot choices.
- Configure DHCP reservations to override all firmware boot policy entries.
Explanation
Correct Answer
A:This directly addresses boot policy order and fallback because a UCS boot policy determines device search order and must reflect provisioned boot media. Confirm the change against boot policy order, effective BIOS settings, device presence and boot logs from the host.
Incorrect Answers
B:Misordered or unavailable devices can redirect the host into unintended boot methods. The relevant correction is to validate UCS boot policy priority and ensure the intended boot device or fallback path is available.
C:Delete the working boot medium to reduce boot choices. The proposed change targets the wrong mechanism or lacks essential validation. A UCS boot policy determines device search order and must reflect provisioned boot media. Relevant evidence is boot policy order, effective BIOS settings, device presence and boot logs from the host.
D:Misordered or unavailable devices can redirect the host into unintended boot methods. The appropriate action remains to validate UCS boot policy priority and ensure the intended boot device or fallback path is available.
Question 462
A C-Series host with both local disk and PXE falls into network boot after the configured disk path is missing. Which collection of observations most directly tests the suspected cause?
- An old inventory export that omits the current chassis and firmware state.
- Boot policy order, effective BIOS settings, device presence and boot logs from the host.
- An operator assurance without current logs, component inventory or health faults.
- The planned service profile template without checking effective deployed settings.
Explanation
Correct Answer
B:These observations test the actual boot policy order and fallback mechanism rather than a superficial management status. A UCS boot policy determines device search order and must reflect provisioned boot media.
Incorrect Answers
A:This information cannot independently verify boot policy order and fallback. The decisive records instead include boot policy order, effective BIOS settings, device presence and boot logs from the host.
C:This information cannot independently verify boot policy order and fallback. A UCS boot policy determines device search order and must reflect provisioned boot media.
D:This information cannot independently verify boot policy order and fallback. The planned service profile template without checking effective deployed settings.
Question 463
A C-Series host with both local disk and PXE falls into network boot after the configured disk path is missing. Which statement most accurately explains this scenario?
- Two logical objects always provide resilience even if they share one failed hardware path.
- All UCS configuration edits take effect without maintenance, validation or dependencies.
- A UCS boot policy determines device search order and must reflect provisioned boot media.
- Out-of-band management reachability guarantees that all host interfaces operate correctly.
Explanation
Correct Answer
C:Validation depends on boot policy order, effective BIOS settings, device presence and boot logs from the host. This explains why the most appropriate response is to validate UCS boot policy priority and ensure the intended boot device or fallback path is available.
Incorrect Answers
A:Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for boot policy order and fallback. The applicable technical behavior is that a UCS boot policy determines device search order and must reflect provisioned boot media. The operator should verify boot policy order, effective BIOS settings, device presence and boot logs from the host.
B:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for boot policy order and fallback. The applicable technical behavior is that a UCS boot policy determines device search order and must reflect provisioned boot media. The operator should verify boot policy order, effective BIOS settings, device presence and boot logs from the host.
D:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for boot policy order and fallback. The applicable technical behavior is that a UCS boot policy determines device search order and must reflect provisioned boot media. The operator should verify boot policy order, effective BIOS settings, device presence and boot logs from the host.
Question 464
A C-Series host with both local disk and PXE falls into network boot after the configured disk path is missing. Assume an engineer instead chooses to use only a VLAN tag change to define BIOS boot order. What is the principal technical consequence of the mistaken choice?
- A controlled failover test itself proves that the previous outage had no cause.
- The only failure is that the administrator preserved a known-good backup.
- Recording chassis health events is what prevents server management.
- Misordered or unavailable devices can redirect the host into unintended boot methods.
Explanation
Correct Answer
D:The proper corrective action is to validate UCS boot policy priority and ensure the intended boot device or fallback path is available. A UCS boot policy determines device search order and must reflect provisioned boot media.
Incorrect Answers
A:This does not explain the actual boot policy order and fallback defect after the shortcut. The meaningful failure is that misordered or unavailable devices can redirect the host into unintended boot methods.
B:This does not explain the actual boot policy order and fallback defect after the shortcut. The relevant evidence is boot policy order, effective BIOS settings, device presence and boot logs from the host.
C:This does not explain the actual boot policy order and fallback defect after the shortcut. Recording chassis health events is what prevents server management.
Question 465
A C-Series host with both local disk and PXE falls into network boot after the configured disk path is missing. The observed failure is: misordered or unavailable devices can redirect the host into unintended boot methods. What should the engineer do to recover and validate the service?
- Correct device priority and target availability, then test normal and fallback boot behavior.
- Delete the working boot medium to reduce boot choices.
- Configure DHCP reservations to override all firmware boot policy entries.
- Use only a VLAN tag change to define BIOS boot order.
Explanation
Correct Answer
A:Validate against boot policy order, effective BIOS settings, device presence and boot logs from the host. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
B:Delete the working boot medium to reduce boot choices. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.
C:Configure DHCP reservations to override all firmware boot policy entries. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.
D:Use only a VLAN tag change to define BIOS boot order. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.
Question 466
An automation team sets a boot order that tries an empty virtual media device before the intended SAN boot target. Which next step should the data center engineer select?
- On this affected device, the engineer should delete the working boot medium to reduce boot choices.
- On this affected device, the engineer should validate UCS boot policy priority and ensure the intended boot device or fallback path is available.
- On this affected device, the engineer should configure DHCP reservations to override all firmware boot policy entries.
- On this affected device, the engineer should use only a VLAN tag change to define BIOS boot order.
Explanation
Correct Answer
B:This directly addresses boot policy order and fallback because a UCS boot policy determines device search order and must reflect provisioned boot media.
Incorrect Answers
A:Delete the working boot medium to reduce boot choices. The proposed change targets the wrong mechanism or lacks essential validation. A UCS boot policy determines device search order and must reflect provisioned boot media. Relevant evidence is boot policy order, effective BIOS settings, device presence and boot logs from the host.
C:Misordered or unavailable devices can redirect the host into unintended boot methods. Configure DHCP reservations to override all firmware boot policy entries.
D:Misordered or unavailable devices can redirect the host into unintended boot methods. Use only a VLAN tag change to define BIOS boot order.
Question 467
An automation team sets a boot order that tries an empty virtual media device before the intended SAN boot target. Which diagnostic record would most strongly confirm the result?
- For this deployment, examine the rack label without current UCS or Intersight policy associations.
- For this deployment, examine an old inventory export that omits the current chassis and firmware state.
- For this deployment, examine boot policy order, effective BIOS settings, device presence and boot logs from the host.
- For this deployment, examine an operator assurance without current logs, component inventory or health faults.
Explanation
Correct Answer
C:These observations test the actual boot policy order and fallback mechanism rather than a superficial management status. They should be checked after validate UCS boot policy priority and ensure the intended boot device or fallback path is available.
Incorrect Answers
A:This information cannot independently verify boot policy order and fallback. The rack label without current UCS or Intersight policy associations.
B:This information cannot independently verify boot policy order and fallback. An old inventory export that omits the current chassis and firmware state.
D:This information cannot independently verify boot policy order and fallback. An operator assurance without current logs, component inventory or health faults.
Question 468
An automation team sets a boot order that tries an empty virtual media device before the intended SAN boot target. Which platform concept should guide the engineer’s assessment?
- For this condition, the applicable principle is that out-of-band management reachability guarantees that all host interfaces operate correctly.
- For this condition, the applicable principle is that two logical objects always provide resilience even if they share one failed hardware path.
- For this condition, the applicable principle is that a rack server that powers on is automatically configured for every SAN and LAN service.
- For this condition, the applicable principle is that a UCS boot policy determines device search order and must reflect provisioned boot media.
Explanation
Correct Answer
D:Validation depends on boot policy order, effective BIOS settings, device presence and boot logs from the host. A UCS boot policy determines device search order and must reflect provisioned boot media.
Incorrect Answers
A:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for boot policy order and fallback. The applicable technical behavior is that a UCS boot policy determines device search order and must reflect provisioned boot media. The operator should verify boot policy order, effective BIOS settings, device presence and boot logs from the host.
B:Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for boot policy order and fallback. The applicable technical behavior is that a UCS boot policy determines device search order and must reflect provisioned boot media. The operator should verify boot policy order, effective BIOS settings, device presence and boot logs from the host.
C:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for boot policy order and fallback. The applicable technical behavior is that a UCS boot policy determines device search order and must reflect provisioned boot media. The operator should verify boot policy order, effective BIOS settings, device presence and boot logs from the host.
Question 469
An automation team sets a boot order that tries an empty virtual media device before the intended SAN boot target. Assume an engineer instead chooses to use only a VLAN tag change to define BIOS boot order. Which root-cause observation follows from that incorrect change?
- The resulting defect is that misordered or unavailable devices can redirect the host into unintended boot methods.
- The resulting defect is that recording chassis health events is what prevents server management.
- The resulting defect is that checking effective service-profile bindings caused the original hardware mismatch.
- The resulting defect is that the only failure is that the administrator preserved a known-good backup.
Explanation
Correct Answer
A:The proper corrective action is to validate UCS boot policy priority and ensure the intended boot device or fallback path is available. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
B:This does not explain the actual boot policy order and fallback defect after the shortcut. In the given case, an automation team sets a boot order that tries an empty virtual media device before the intended SAN boot target.
C:This does not explain the actual boot policy order and fallback defect after the shortcut. Checking effective service-profile bindings caused the original hardware mismatch.
D:This does not explain the actual boot policy order and fallback defect after the shortcut. The only failure is that the administrator preserved a known-good backup.
Question 470
An automation team sets a boot order that tries an empty virtual media device before the intended SAN boot target. The observed failure is: misordered or unavailable devices can redirect the host into unintended boot methods. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to configure DHCP reservations to override all firmware boot policy entries.
- The controlled remediation is to correct device priority and target availability, then test normal and fallback boot behavior.
- The controlled remediation is to use only a VLAN tag change to define BIOS boot order.
- The controlled remediation is to delete the working boot medium to reduce boot choices.
Explanation
Correct Answer
B:Validate against boot policy order, effective BIOS settings, device presence and boot logs from the host. A UCS boot policy determines device search order and must reflect provisioned boot media.
Incorrect Answers
A:Configure DHCP reservations to override all firmware boot policy entries. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.
C:Use only a VLAN tag change to define BIOS boot order. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.
D:Delete the working boot medium to reduce boot choices. This would not reliably restore service after the stated fault. Misordered or unavailable devices can redirect the host into unintended boot methods. The controlled recovery is to correct device priority and target availability, then test normal and fallback boot behavior.