Cisco 350-601 Practice Test 49
Question 480
A new Intersight-managed compute domain cannot provision an X-Series server because domain and server policies are missing. The observed failure is: treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. What is the BEST controlled recovery once this failure is recognized?
- The controlled remediation is to assume chassis insertion automatically builds LAN and SAN policies.
- The controlled remediation is to attempt to configure every UCS-X blade only through a classic UCSM service profile.
- The controlled remediation is to disable the claimed device connection so Intersight cannot receive inventory.
- The controlled remediation is to define and assign proper Intersight domain and server policies and validate the server life cycle.
Explanation
Correct Answer
D:UCS-X in Intersight Managed Mode is configured through Intersight policies rather than a traditional UCS Manager domain. Validate against Intersight organization and domain inventory, assigned profiles, policy state and server operational health.
Incorrect Answers
A:Assume chassis insertion automatically builds LAN and SAN policies. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.
B:Attempt to configure every UCS-X blade only through a classic UCSM service profile. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.
C:Disable the claimed device connection so Intersight cannot receive inventory. This would not reliably restore service after the stated fault. Treating IMM as UCSM-managed leaves essential policy objects unprovisioned or misplaced. The controlled recovery is to define and assign proper Intersight domain and server policies and validate the server life cycle.
Question 481
A UCS domain has access to local management but cannot report health to Intersight because device connector claims are unresolved. What is the BEST supported implementation or corrective action?
- Check the Intersight device connector status and restore required claim, reachability and trust prerequisites.
- Disable all DNS and proxy configuration to simplify cloud reachability.
- Assume a server's VLAN trunk automatically handles connector trust.
- Use an FC alias in place of Intersight device registration.
Explanation
Correct Answer
A:This directly addresses Intersight claimed-device connectivity because Intersight management requires an authenticated and reachable connector path for the claimed device. Confirm the change against connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
Incorrect Answers
B:Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. The relevant correction is to check the Intersight device connector status and restore required claim, reachability and trust prerequisites.
C:Assume a server's VLAN trunk automatically handles connector trust. The proposed change targets the wrong mechanism or lacks essential validation. Intersight management requires an authenticated and reachable connector path for the claimed device. Relevant evidence is connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
D:Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. The appropriate action remains to check the Intersight device connector status and restore required claim, reachability and trust prerequisites.
Question 482
A UCS domain has access to local management but cannot report health to Intersight because device connector claims are unresolved. Which evidence BEST verifies the intended technical behavior?
- The planned service profile template without checking effective deployed settings.
- Connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
- An old inventory export that omits the current chassis and firmware state.
- A management ping that does not verify the required server or adapter function.
Explanation
Correct Answer
B:These observations test the actual Intersight claimed-device connectivity mechanism rather than a superficial management status. Intersight management requires an authenticated and reachable connector path for the claimed device.
Incorrect Answers
A:The planned service profile template without checking effective deployed settings. This information cannot independently verify Intersight claimed-device connectivity. The decisive records instead include connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. Intersight management requires an authenticated and reachable connector path for the claimed device.
C:An old inventory export that omits the current chassis and firmware state. This information cannot independently verify Intersight claimed-device connectivity. The decisive records instead include connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. Intersight management requires an authenticated and reachable connector path for the claimed device.
D:A management ping that does not verify the required server or adapter function. This information cannot independently verify Intersight claimed-device connectivity. The decisive records instead include connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. Intersight management requires an authenticated and reachable connector path for the claimed device.
Question 483
A UCS domain has access to local management but cannot report health to Intersight because device connector claims are unresolved. Which principle BEST explains why the recommended solution is appropriate?
- Out-of-band management reachability guarantees that all host interfaces operate correctly.
- Service profiles can never change effective network identity or firmware behavior.
- Intersight management requires an authenticated and reachable connector path for the claimed device.
- All UCS configuration edits take effect without maintenance, validation or dependencies.
Explanation
Correct Answer
C:Validation depends on connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. This explains why the most appropriate response is to check the Intersight device connector status and restore required claim, reachability and trust prerequisites.
Incorrect Answers
A:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for Intersight claimed-device connectivity. The applicable technical behavior is that Intersight management requires an authenticated and reachable connector path for the claimed device. The operator should verify connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
B:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for Intersight claimed-device connectivity. The applicable technical behavior is that Intersight management requires an authenticated and reachable connector path for the claimed device. The operator should verify connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
D:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for Intersight claimed-device connectivity. The applicable technical behavior is that Intersight management requires an authenticated and reachable connector path for the claimed device. The operator should verify connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
Question 484
A UCS domain has access to local management but cannot report health to Intersight because device connector claims are unresolved. Assume an engineer instead chooses to disable all DNS and proxy configuration to simplify cloud reachability. What is the MOST significant failure introduced by that shortcut?
- The underlying fault was caused only by retaining accurate firmware inventory.
- A controlled failover test itself proves that the previous outage had no cause.
- The only failure is that the administrator preserved a known-good backup.
- Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable.
Explanation
Correct Answer
D:The proper corrective action is to check the Intersight device connector status and restore required claim, reachability and trust prerequisites. Intersight management requires an authenticated and reachable connector path for the claimed device.
Incorrect Answers
A:This does not explain the actual Intersight claimed-device connectivity defect after the shortcut. The meaningful failure is that local chassis operation can continue while Intersight remote inventory and policy operations are unavailable.
B:This does not explain the actual Intersight claimed-device connectivity defect after the shortcut. The relevant evidence is connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
C:This does not explain the actual Intersight claimed-device connectivity defect after the shortcut. The only failure is that the administrator preserved a known-good backup.
Question 485
A UCS domain has access to local management but cannot report health to Intersight because device connector claims are unresolved. The observed failure is: local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. What is the BEST controlled recovery once this failure is recognized?
- Repair claim and connector communication and verify real-time inventory and authorized management.
- Assume a server's VLAN trunk automatically handles connector trust.
- Use an FC alias in place of Intersight device registration.
- Disable all DNS and proxy configuration to simplify cloud reachability.
Explanation
Correct Answer
A:Validate against connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
B:Assume a server's VLAN trunk automatically handles connector trust. This would not reliably restore service after the stated fault. Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. The controlled recovery is to repair claim and connector communication and verify real-time inventory and authorized management.
C:Use an FC alias in place of Intersight device registration. This would not reliably restore service after the stated fault. Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. The controlled recovery is to repair claim and connector communication and verify real-time inventory and authorized management.
D:Disable all DNS and proxy configuration to simplify cloud reachability. This would not reliably restore service after the stated fault. Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. The controlled recovery is to repair claim and connector communication and verify real-time inventory and authorized management.
Question 486
A remote UCS-X deployment shows its management connector offline in Intersight after outbound connectivity changed. Which configuration decision MOST directly resolves the issue?
- On this affected device, the engineer should assume a server's VLAN trunk automatically handles connector trust.
- On this affected device, the engineer should check the Intersight device connector status and restore required claim, reachability and trust prerequisites.
- On this affected device, the engineer should use an FC alias in place of Intersight device registration.
- On this affected device, the engineer should disable all DNS and proxy configuration to simplify cloud reachability.
Explanation
Correct Answer
B:This directly addresses Intersight claimed-device connectivity because Intersight management requires an authenticated and reachable connector path for the claimed device.
Incorrect Answers
A:Assume a server's VLAN trunk automatically handles connector trust. The proposed change targets the wrong mechanism or lacks essential validation. Intersight management requires an authenticated and reachable connector path for the claimed device. Relevant evidence is connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
C:Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. Use an FC alias in place of Intersight device registration.
D:Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. Disable all DNS and proxy configuration to simplify cloud reachability.
Question 487
A remote UCS-X deployment shows its management connector offline in Intersight after outbound connectivity changed. What should the engineer inspect to confirm the actual state?
- For this deployment, examine an operator assurance without current logs, component inventory or health faults.
- For this deployment, examine the planned service profile template without checking effective deployed settings.
- For this deployment, examine connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
- For this deployment, examine an old inventory export that omits the current chassis and firmware state.
Explanation
Correct Answer
C:These observations test the actual Intersight claimed-device connectivity mechanism rather than a superficial management status. They should be checked after check the Intersight device connector status and restore required claim, reachability and trust prerequisites.
Incorrect Answers
A:An operator assurance without current logs, component inventory or health faults. This information cannot independently verify Intersight claimed-device connectivity. The decisive records instead include connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. Intersight management requires an authenticated and reachable connector path for the claimed device.
B:The planned service profile template without checking effective deployed settings. This information cannot independently verify Intersight claimed-device connectivity. The decisive records instead include connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. Intersight management requires an authenticated and reachable connector path for the claimed device.
D:An old inventory export that omits the current chassis and firmware state. This information cannot independently verify Intersight claimed-device connectivity. The decisive records instead include connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. Intersight management requires an authenticated and reachable connector path for the claimed device.
Question 488
A remote UCS-X deployment shows its management connector offline in Intersight after outbound connectivity changed. What technical behavior underlies the correct decision?
- For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.
- For this condition, the applicable principle is that out-of-band management reachability guarantees that all host interfaces operate correctly.
- For this condition, the applicable principle is that two logical objects always provide resilience even if they share one failed hardware path.
- For this condition, the applicable principle is that Intersight management requires an authenticated and reachable connector path for the claimed device.
Explanation
Correct Answer
D:Validation depends on connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. Intersight management requires an authenticated and reachable connector path for the claimed device.
Incorrect Answers
A:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for Intersight claimed-device connectivity. The applicable technical behavior is that Intersight management requires an authenticated and reachable connector path for the claimed device. The operator should verify connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
B:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for Intersight claimed-device connectivity. The applicable technical behavior is that Intersight management requires an authenticated and reachable connector path for the claimed device. The operator should verify connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
C:Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for Intersight claimed-device connectivity. The applicable technical behavior is that Intersight management requires an authenticated and reachable connector path for the claimed device. The operator should verify connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory.
Question 489
A remote UCS-X deployment shows its management connector offline in Intersight after outbound connectivity changed. Assume an engineer instead chooses to disable all DNS and proxy configuration to simplify cloud reachability. Which resulting risk or fault should the reviewer identify?
- The resulting defect is that local chassis operation can continue while Intersight remote inventory and policy operations are unavailable.
- The resulting defect is that the only failure is that the administrator preserved a known-good backup.
- The resulting defect is that recording chassis health events is what prevents server management.
- The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.
Explanation
Correct Answer
A:The proper corrective action is to check the Intersight device connector status and restore required claim, reachability and trust prerequisites. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
B:This does not explain the actual Intersight claimed-device connectivity defect after the shortcut. In the given case, a remote UCS-X deployment shows its management connector offline in Intersight after outbound connectivity changed.
C:This does not explain the actual Intersight claimed-device connectivity defect after the shortcut. Recording chassis health events is what prevents server management.
D:This does not explain the actual Intersight claimed-device connectivity defect after the shortcut. A controlled failover test itself proves that the previous outage had no cause.
Question 490
A remote UCS-X deployment shows its management connector offline in Intersight after outbound connectivity changed. The observed failure is: local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. Which remediation most directly restores the intended behavior?
- The controlled remediation is to use an FC alias in place of Intersight device registration.
- The controlled remediation is to repair claim and connector communication and verify real-time inventory and authorized management.
- The controlled remediation is to disable all DNS and proxy configuration to simplify cloud reachability.
- The controlled remediation is to assume a server's VLAN trunk automatically handles connector trust.
Explanation
Correct Answer
B:Validate against connector status, claim identity, reachability and certificate or proxy health, and current Intersight inventory. Intersight management requires an authenticated and reachable connector path for the claimed device.
Incorrect Answers
A:Use an FC alias in place of Intersight device registration. This would not reliably restore service after the stated fault. Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. The controlled recovery is to repair claim and connector communication and verify real-time inventory and authorized management.
C:Disable all DNS and proxy configuration to simplify cloud reachability. This would not reliably restore service after the stated fault. Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. The controlled recovery is to repair claim and connector communication and verify real-time inventory and authorized management.
D:Assume a server's VLAN trunk automatically handles connector trust. This would not reliably restore service after the stated fault. Local chassis operation can continue while Intersight remote inventory and policy operations are unavailable. The controlled recovery is to repair claim and connector communication and verify real-time inventory and authorized management.