cert
cert-1
cert-2

Pass Nokia 4A0-C03 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
4A0-C03 Exam - Verified By Experts
4A0-C03 Premium File

4A0-C03 Premium File

$69.99
$76.99
  • Premium File 145 Questions & Answers. Last Update: Nov 23, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Nokia 4A0-C03 Practice Test 78

Question 770

A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Which measurable result would verify success without relying on assumptions?

  1. The subscriber obtains intended shared routed connectivity with no unauthorized VPN imports.
  2. All frames within the contracted size pass from source to remote customer handoff.
  3. The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.
  4. Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.

Explanation

Correct Answer

C:

The acceptance measurement for this case is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes. It establishes that the intended remediation (“Implement the approved layer-two spoke termination and layer-three service association”) was effective and can be corroborated by: Compare incoming Ethernet encapsulation with expected customer VPRN route membership.

Incorrect Answers

A:

The actual case evidence is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The proposed option addresses a different condition: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. Confirm the distinction by checking: Inspect spoke SDP binding and the routed service interface on the destination PE. The response supported by the evidence is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.

B:

The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The pertinent verification is: Inspect spoke SDP binding and the routed service interface on the destination PE. The action or outcome to select here is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.

D:

The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The distinguishing check is: Inspect spoke SDP binding and the routed service interface on the destination PE. The supported action or criterion is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.

Question 771

A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Which change most directly addresses the observed problem?

  1. Diagnose the remote attachment status rather than changing the already healthy transport LSP.
  2. Restore the intended service administrative state after confirming maintenance authorization.
  3. Monitor the individual customer SAP operational state as well as transport and service status.
  4. Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.

Explanation

Correct Answer

C:

The fault stated in this case is: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The specific corrective action is: Monitor the individual customer SAP operational state as well as transport and service status. Confirm it with: Inspect SAP admin and oper state and its assigned service identifier. The expected end-to-end outcome is: Monitoring flags the correct customer attachment outage even when the core transport remains active.

Incorrect Answers

A:

The alternative is directed at this separate case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The present incident is: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The pertinent verification is: Inspect SAP admin and oper state and its assigned service identifier. The action or outcome to select here is: Monitor the individual customer SAP operational state as well as transport and service status.

B:

This choice does not address the stated situation: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Its competing context is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The relevant diagnostic is: Inspect SAP admin and oper state and its assigned service identifier. The case-supported response is: Monitor the individual customer SAP operational state as well as transport and service status.

D:

These other facts could justify the alternative: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. They differ from the stated case: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Test the distinction using: Inspect SAP admin and oper state and its assigned service identifier. The case-specific response is: Monitor the individual customer SAP operational state as well as transport and service status.

Question 772

A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Which TWO independent checks would best establish what is happening? (Select TWO.)

  1. Inspect service OAM result and remote SAP policy drop counters together.
  2. Inspect pseudowire status TLVs and remote attachment-circuit alarms.
  3. Capture synthetic frames at both access ports and compare VLAN tag presence.
  4. Inspect SAP admin and oper state and its assigned service identifier.
  5. Compare customer-facing interface counters with the SDP and Epipe health report.

Explanation

Correct Answers

D:

This is a direct diagnostic for the reported fault: Inspect SAP admin and oper state and its assigned service identifier. A second independent check is: Compare customer-facing interface counters with the SDP and Epipe health report. Combined evidence distinguishes the fault before implementing: Monitor the individual customer SAP operational state as well as transport and service status.

E:

This is a direct diagnostic for the reported fault: Compare customer-facing interface counters with the SDP and Epipe health report. A second independent check is: Inspect SAP admin and oper state and its assigned service identifier. Combined evidence distinguishes the fault before implementing: Monitor the individual customer SAP operational state as well as transport and service status.

Incorrect Answers

A:

This choice does not address the stated situation: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Its competing context is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The relevant diagnostic is: Inspect SAP admin and oper state and its assigned service identifier. The case-supported response is: Inspect SAP admin and oper state and its assigned service identifier; and Compare customer-facing interface counters with the SDP and Epipe health report.

B:

The alternative applies to another situation: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The reported case instead states: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The distinguishing check is: Inspect SAP admin and oper state and its assigned service identifier. The supported action or criterion is: Inspect SAP admin and oper state and its assigned service identifier; and Compare customer-facing interface counters with the SDP and Epipe health report.

C:

These other facts could justify the alternative: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. They differ from the stated case: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Test the distinction using: Inspect SAP admin and oper state and its assigned service identifier. The case-specific response is: Inspect SAP admin and oper state and its assigned service identifier; and Compare customer-facing interface counters with the SDP and Epipe health report.

Question 773

A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. What is the key technical or security failure this situation can produce?

  1. Aggregated service status can conceal a failed required attachment circuit.
  2. A healthy interface cannot carry private-wire traffic through a disabled service instance.
  3. A green transport or SDP check cannot establish application reachability through customer filters.
  4. A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.

Explanation

Correct Answer

A:

The observed condition is: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The principal operational or security impact is: Aggregated service status can conceal a failed required attachment circuit. The supported repair is: Monitor the individual customer SAP operational state as well as transport and service status. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

B:

These other facts could justify the alternative: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. They differ from the stated case: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Test the distinction using: Inspect SAP admin and oper state and its assigned service identifier. The case-specific response is: Aggregated service status can conceal a failed required attachment circuit.

C:

The actual case evidence is: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Inspect SAP admin and oper state and its assigned service identifier. The response supported by the evidence is: Aggregated service status can conceal a failed required attachment circuit.

D:

The alternative is directed at this separate case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The present incident is: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The pertinent verification is: Inspect SAP admin and oper state and its assigned service identifier. The action or outcome to select here is: Aggregated service status can conceal a failed required attachment circuit.

Question 774

A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Choose TWO complementary steps: one repair and one precaution against collateral impact. (Select TWO.)

  1. Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
  2. Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.
  3. Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
  4. Monitor the individual customer SAP operational state as well as transport and service status.
  5. Use a test shutdown and observe alarms without affecting unrelated SAPs.

Explanation

Correct Answers

D:

This is the required technical repair: Monitor the individual customer SAP operational state as well as transport and service status. The separately necessary deployment safeguard is: Use a test shutdown and observe alarms without affecting unrelated SAPs. Together they address: Aggregated service status can conceal a failed required attachment circuit.

E:

This safeguard prevents unwanted collateral effects: Use a test shutdown and observe alarms without affecting unrelated SAPs. Its complementary corrective change is: Monitor the individual customer SAP operational state as well as transport and service status. Both are required because: Aggregated service status can conceal a failed required attachment circuit.

Incorrect Answers

A:

These other facts could justify the alternative: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. They differ from the stated case: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Test the distinction using: Inspect SAP admin and oper state and its assigned service identifier. The case-specific response is: Monitor the individual customer SAP operational state as well as transport and service status; and Use a test shutdown and observe alarms without affecting unrelated SAPs.

B:

The actual case evidence is: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The proposed option addresses a different condition: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Confirm the distinction by checking: Inspect SAP admin and oper state and its assigned service identifier. The response supported by the evidence is: Monitor the individual customer SAP operational state as well as transport and service status; and Use a test shutdown and observe alarms without affecting unrelated SAPs.

C:

The alternative is directed at this separate case: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The present incident is: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The pertinent verification is: Inspect SAP admin and oper state and its assigned service identifier. The action or outcome to select here is: Monitor the individual customer SAP operational state as well as transport and service status; and Use a test shutdown and observe alarms without affecting unrelated SAPs.

Question 775

A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. What evidence would demonstrate that the intended fix worked correctly?

  1. Monitoring flags the correct customer attachment outage even when the core transport remains active.
  2. The contracted customer application passes while unapproved access remains blocked.
  3. The authorized Epipe becomes operational and remote customer MAC traffic is restored.
  4. The remote attachment comes Up and the Epipe reports end-to-end operational service.

Explanation

Correct Answer

A:

The acceptance measurement for this case is: Monitoring flags the correct customer attachment outage even when the core transport remains active. It establishes that the intended remediation (“Monitor the individual customer SAP operational state as well as transport and service status”) was effective and can be corroborated by: Compare customer-facing interface counters with the SDP and Epipe health report.

Incorrect Answers

B:

The alternative is directed at this separate case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The present incident is: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The pertinent verification is: Inspect SAP admin and oper state and its assigned service identifier. The action or outcome to select here is: Monitoring flags the correct customer attachment outage even when the core transport remains active.

C:

This choice does not address the stated situation: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Its competing context is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The relevant diagnostic is: Inspect SAP admin and oper state and its assigned service identifier. The case-supported response is: Monitoring flags the correct customer attachment outage even when the core transport remains active.

D:

The alternative applies to another situation: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The reported case instead states: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The distinguishing check is: Inspect SAP admin and oper state and its assigned service identifier. The supported action or criterion is: Monitoring flags the correct customer attachment outage even when the core transport remains active.

Question 776

A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Which corrective action best resolves this particular network fault?

  1. Verify MTU at both customer attachment endpoints and the transport service overhead.
  2. Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
  3. Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
  4. Diagnose the remote attachment status rather than changing the already healthy transport LSP.

Explanation

Correct Answer

A:

The fault stated in this case is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The specific corrective action is: Verify MTU at both customer attachment endpoints and the transport service overhead. Confirm it with: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The expected end-to-end outcome is: All frames within the contracted size pass from source to remote customer handoff.

Incorrect Answers

B:

This choice does not address the stated situation: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Its competing context is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The relevant diagnostic is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The case-supported response is: Verify MTU at both customer attachment endpoints and the transport service overhead.

C:

The alternative applies to another situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The reported case instead states: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The distinguishing check is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The supported action or criterion is: Verify MTU at both customer attachment endpoints and the transport service overhead.

D:

These other facts could justify the alternative: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. They differ from the stated case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Test the distinction using: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The case-specific response is: Verify MTU at both customer attachment endpoints and the transport service overhead.

Question 777

A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Before proposing a change, which TWO observations would give the most useful confirmation? (Select TWO.)

  1. Inspect pseudowire status TLVs and remote attachment-circuit alarms.
  2. Inspect actual SR OS port mode and the service attachment hierarchy.
  3. Compare permitted customer frame size with every core link MTU and label count.
  4. Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
  5. Compare frame-size dependent drops at the remote port against permitted service limits.

Explanation

Correct Answers

D:

This is a direct diagnostic for the reported fault: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. A second independent check is: Compare frame-size dependent drops at the remote port against permitted service limits. Combined evidence distinguishes the fault before implementing: Verify MTU at both customer attachment endpoints and the transport service overhead.

E:

This is a direct diagnostic for the reported fault: Compare frame-size dependent drops at the remote port against permitted service limits. A second independent check is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. Combined evidence distinguishes the fault before implementing: Verify MTU at both customer attachment endpoints and the transport service overhead.

Incorrect Answers

A:

This choice does not address the stated situation: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The case-supported response is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU; and Compare frame-size dependent drops at the remote port against permitted service limits.

B:

The alternative applies to another situation: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The reported case instead states: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The distinguishing check is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The supported action or criterion is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU; and Compare frame-size dependent drops at the remote port against permitted service limits.

C:

These other facts could justify the alternative: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. They differ from the stated case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Test the distinction using: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The case-specific response is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU; and Compare frame-size dependent drops at the remote port against permitted service limits.

Question 778

A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Which statement best describes the immediate risk of ignoring this problem?

  1. Service control sessions can remain healthy while oversized customer frames are silently dropped.
  2. A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
  3. Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.
  4. A green transport or SDP check cannot establish application reachability through customer filters.

Explanation

Correct Answer

C:

The observed condition is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The principal operational or security impact is: Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size. The supported repair is: Verify MTU at both customer attachment endpoints and the transport service overhead. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The reported case instead states: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The distinguishing check is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The supported action or criterion is: Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.

B:

These other facts could justify the alternative: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. They differ from the stated case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Test the distinction using: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The case-specific response is: Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.

D:

The alternative is directed at this separate case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The present incident is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The pertinent verification is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The action or outcome to select here is: Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.

Question 779

A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Which TWO measures together address the fault while protecting other services? (Select TWO.)

  1. Troubleshoot the customer service attachment separately from the operational SDP transport test.
  2. Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
  3. Verify MTU at both customer attachment endpoints and the transport service overhead.
  4. Test known safe frame lengths and obtain customer approval before changing attachment MTUs.
  5. Distinguish access ports and their SAPs from the provider's network-facing transport ports.

Explanation

Correct Answers

C:

This is the required technical repair: Verify MTU at both customer attachment endpoints and the transport service overhead. The separately necessary deployment safeguard is: Test known safe frame lengths and obtain customer approval before changing attachment MTUs. Together they address: Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.

D:

This safeguard prevents unwanted collateral effects: Test known safe frame lengths and obtain customer approval before changing attachment MTUs. Its complementary corrective change is: Verify MTU at both customer attachment endpoints and the transport service overhead. Both are required because: Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.

Incorrect Answers

A:

These other facts could justify the alternative: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. They differ from the stated case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Test the distinction using: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The case-specific response is: Verify MTU at both customer attachment endpoints and the transport service overhead; and Test known safe frame lengths and obtain customer approval before changing attachment MTUs.

B:

The actual case evidence is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The proposed option addresses a different condition: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Confirm the distinction by checking: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The response supported by the evidence is: Verify MTU at both customer attachment endpoints and the transport service overhead; and Test known safe frame lengths and obtain customer approval before changing attachment MTUs.

E:

The alternative applies to another situation: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The reported case instead states: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The distinguishing check is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The supported action or criterion is: Verify MTU at both customer attachment endpoints and the transport service overhead; and Test known safe frame lengths and obtain customer approval before changing attachment MTUs.

Question 780

A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. After the approved repair, which outcome best demonstrates that this exact fault is resolved?

  1. Permitted large frames reach all sites and discard counters stop increasing.
  2. The contracted customer application passes while unapproved access remains blocked.
  3. The remote attachment comes Up and the Epipe reports end-to-end operational service.
  4. All frames within the contracted size pass from source to remote customer handoff.

Explanation

Correct Answer

D:

The acceptance measurement for this case is: All frames within the contracted size pass from source to remote customer handoff. It establishes that the intended remediation (“Verify MTU at both customer attachment endpoints and the transport service overhead”) was effective and can be corroborated by: Compare frame-size dependent drops at the remote port against permitted service limits.

Incorrect Answers

A:

The actual case evidence is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The proposed option addresses a different condition: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Confirm the distinction by checking: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The response supported by the evidence is: All frames within the contracted size pass from source to remote customer handoff.

B:

The alternative is directed at this separate case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The present incident is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The pertinent verification is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The action or outcome to select here is: All frames within the contracted size pass from source to remote customer handoff.

C:

This choice does not address the stated situation: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The case-supported response is: All frames within the contracted size pass from source to remote customer handoff.

Nokia NRS II Composite: IS-IS version (4A0-C03) Practice Tests