Nokia 4A0-C03 Practice Test 79
Question 780
A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. After the approved repair, which outcome best demonstrates that this exact fault is resolved?
- Permitted large frames reach all sites and discard counters stop increasing.
- The contracted customer application passes while unapproved access remains blocked.
- The remote attachment comes Up and the Epipe reports end-to-end operational service.
- All frames within the contracted size pass from source to remote customer handoff.
Explanation
Correct Answer
D:The acceptance measurement for this case is: All frames within the contracted size pass from source to remote customer handoff. It establishes that the intended remediation (“Verify MTU at both customer attachment endpoints and the transport service overhead”) was effective and can be corroborated by: Compare frame-size dependent drops at the remote port against permitted service limits.
Incorrect Answers
A:The actual case evidence is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The proposed option addresses a different condition: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Confirm the distinction by checking: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The response supported by the evidence is: All frames within the contracted size pass from source to remote customer handoff.
B:The alternative is directed at this separate case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The present incident is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The pertinent verification is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The action or outcome to select here is: All frames within the contracted size pass from source to remote customer handoff.
C:This choice does not address the stated situation: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Inspect ingress and egress SAP size limits alongside SDP tunnel MTU. The case-supported response is: All frames within the contracted size pass from source to remote customer handoff.
Question 781
An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. An operator needs a controlled repair. Which response is most appropriate?
- Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
- Recognize dynamic MAC aging and confirm attachment state before declaring service failure.
- Choose the single contracted routing service association and remove the conflicting attachment.
- Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
Explanation
Correct Answer
D:The fault stated in this case is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The specific corrective action is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs. Confirm it with: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The expected end-to-end outcome is: Each service ID resolves to one authorized tenant and all attachments remain correctly mapped.
Incorrect Answers
A:The alternative is directed at this separate case: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The present incident is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The pertinent verification is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The action or outcome to select here is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
B:This choice does not address the stated situation: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Its competing context is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The relevant diagnostic is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The case-supported response is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
C:The alternative applies to another situation: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The reported case instead states: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The distinguishing check is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The supported action or criterion is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
Question 782
An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Which TWO diagnostic investigations most directly test the cause? (Select TWO.)
- Inspect MAC move records and remote endpoint identities associated with the address.
- Inspect live service IDs and associations with SAP, SDP and tenant metadata.
- Compare retired and new provisioning records and the operational dashboard references.
- Inspect forwarding database aging timers and the current learned location.
- Inspect active SAP-to-service associations and routing instance membership.
Explanation
Correct Answers
B:This is a direct diagnostic for the reported fault: Inspect live service IDs and associations with SAP, SDP and tenant metadata. A second independent check is: Compare retired and new provisioning records and the operational dashboard references. Combined evidence distinguishes the fault before implementing: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
C:This is a direct diagnostic for the reported fault: Compare retired and new provisioning records and the operational dashboard references. A second independent check is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. Combined evidence distinguishes the fault before implementing: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
Incorrect Answers
A:This choice does not address the stated situation: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Its competing context is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The relevant diagnostic is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The case-supported response is: Inspect live service IDs and associations with SAP, SDP and tenant metadata; and Compare retired and new provisioning records and the operational dashboard references.
D:The actual case evidence is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The proposed option addresses a different condition: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Confirm the distinction by checking: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The response supported by the evidence is: Inspect live service IDs and associations with SAP, SDP and tenant metadata; and Compare retired and new provisioning records and the operational dashboard references.
E:The alternative is directed at this separate case: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The present incident is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The pertinent verification is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The action or outcome to select here is: Inspect live service IDs and associations with SAP, SDP and tenant metadata; and Compare retired and new provisioning records and the operational dashboard references.
Question 783
An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Which specific consequence explains why a repair is necessary?
- An aged MAC entry alone is not proof of failed transport or endpoint hardware.
- Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors.
- Mixing shared internet and private VPN contexts can break routing or expose sensitive prefixes.
- Incorrect SAP membership can create a serious cross-tenant layer-two data exposure.
Explanation
Correct Answer
B:The observed condition is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The principal operational or security impact is: Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors. The supported repair is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The reported case instead states: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The distinguishing check is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The supported action or criterion is: Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors.
C:The actual case evidence is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The proposed option addresses a different condition: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Confirm the distinction by checking: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The response supported by the evidence is: Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors.
D:The alternative is directed at this separate case: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The present incident is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The pertinent verification is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The action or outcome to select here is: Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors.
Question 784
An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Which TWO actions form both a suitable correction and its necessary change-control safeguard? (Select TWO.)
- Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards.
- Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
- Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
- Confirm tenant authorization and migrate only the affected service within an approved window.
- Choose the single contracted routing service association and remove the conflicting attachment.
Explanation
Correct Answers
B:This is the required technical repair: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs. The separately necessary deployment safeguard is: Confirm tenant authorization and migrate only the affected service within an approved window. Together they address: Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors.
D:This safeguard prevents unwanted collateral effects: Confirm tenant authorization and migrate only the affected service within an approved window. Its complementary corrective change is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs. Both are required because: Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors.
Incorrect Answers
A:These other facts could justify the alternative: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. They differ from the stated case: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Test the distinction using: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The case-specific response is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs; and Confirm tenant authorization and migrate only the affected service within an approved window.
C:The alternative is directed at this separate case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The present incident is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The pertinent verification is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The action or outcome to select here is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs; and Confirm tenant authorization and migrate only the affected service within an approved window.
E:The alternative applies to another situation: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The reported case instead states: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The distinguishing check is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The supported action or criterion is: Reconcile unique internal service identifiers with current customer ownership and the intended SAPs; and Confirm tenant authorization and migrate only the affected service within an approved window.
Question 785
An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Which post-change observation is the strongest acceptance criterion?
- Frames from one customer remain isolated within its approved VPLS membership.
- Each service ID resolves to one authorized tenant and all attachments remain correctly mapped.
- The interface belongs to the authorized service only and its routing behavior matches the contract.
- The expected MAC is relearned on the correct site while the service stays operational.
Explanation
Correct Answer
B:The acceptance measurement for this case is: Each service ID resolves to one authorized tenant and all attachments remain correctly mapped. It establishes that the intended remediation (“Reconcile unique internal service identifiers with current customer ownership and the intended SAPs”) was effective and can be corroborated by: Compare retired and new provisioning records and the operational dashboard references.
Incorrect Answers
A:The actual case evidence is: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The proposed option addresses a different condition: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Confirm the distinction by checking: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The response supported by the evidence is: Each service ID resolves to one authorized tenant and all attachments remain correctly mapped.
C:This choice does not address the stated situation: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Its competing context is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The relevant diagnostic is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The case-supported response is: Each service ID resolves to one authorized tenant and all attachments remain correctly mapped.
D:The alternative applies to another situation: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The reported case instead states: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The distinguishing check is: Inspect live service IDs and associations with SAP, SDP and tenant metadata. The supported action or criterion is: Each service ID resolves to one authorized tenant and all attachments remain correctly mapped.
Question 786
A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Which next technical step should the engineer prioritize?
- Diagnose the remote attachment status rather than changing the already healthy transport LSP.
- Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
- Verify MTU at both customer attachment endpoints and the transport service overhead.
- Troubleshoot the customer service attachment separately from the operational SDP transport test.
Explanation
Correct Answer
B:The fault stated in this case is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The specific corrective action is: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter. Confirm it with: Inspect service OAM result and remote SAP policy drop counters together. The expected end-to-end outcome is: The contracted customer application passes while unapproved access remains blocked.
Incorrect Answers
A:The alternative is directed at this separate case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The present incident is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The pertinent verification is: Inspect service OAM result and remote SAP policy drop counters together. The action or outcome to select here is: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
C:The alternative applies to another situation: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The reported case instead states: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The distinguishing check is: Inspect service OAM result and remote SAP policy drop counters together. The supported action or criterion is: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
D:These other facts could justify the alternative: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. They differ from the stated case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Test the distinction using: Inspect service OAM result and remote SAP policy drop counters together. The case-specific response is: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
Question 787
A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Which TWO items of evidence should the engineer examine first? (Select TWO.)
- Inspect the SAP's VLAN tag association and customer ingress discard counters.
- Compare permitted customer frame size with every core link MTU and label count.
- Inspect service OAM result and remote SAP policy drop counters together.
- Compare a controlled permitted frame with the actual customer application's encapsulation.
- Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
Explanation
Correct Answers
C:This is a direct diagnostic for the reported fault: Inspect service OAM result and remote SAP policy drop counters together. A second independent check is: Compare a controlled permitted frame with the actual customer application's encapsulation. Combined evidence distinguishes the fault before implementing: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
D:This is a direct diagnostic for the reported fault: Compare a controlled permitted frame with the actual customer application's encapsulation. A second independent check is: Inspect service OAM result and remote SAP policy drop counters together. Combined evidence distinguishes the fault before implementing: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
Incorrect Answers
A:This choice does not address the stated situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Its competing context is: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The relevant diagnostic is: Inspect service OAM result and remote SAP policy drop counters together. The case-supported response is: Inspect service OAM result and remote SAP policy drop counters together; and Compare a controlled permitted frame with the actual customer application's encapsulation.
B:The alternative applies to another situation: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The reported case instead states: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The distinguishing check is: Inspect service OAM result and remote SAP policy drop counters together. The supported action or criterion is: Inspect service OAM result and remote SAP policy drop counters together; and Compare a controlled permitted frame with the actual customer application's encapsulation.
E:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The pertinent verification is: Inspect service OAM result and remote SAP policy drop counters together. The action or outcome to select here is: Inspect service OAM result and remote SAP policy drop counters together; and Compare a controlled permitted frame with the actual customer application's encapsulation.
Question 788
A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. If the condition is left unresolved, which operational consequence is most directly at risk?
- Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.
- A green transport or SDP check cannot establish application reachability through customer filters.
- A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
- Transport OAM success does not guarantee correct attachment or customer encapsulation.
Explanation
Correct Answer
B:The observed condition is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The principal operational or security impact is: A green transport or SDP check cannot establish application reachability through customer filters. The supported repair is: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The reported case instead states: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The distinguishing check is: Inspect service OAM result and remote SAP policy drop counters together. The supported action or criterion is: A green transport or SDP check cannot establish application reachability through customer filters.
C:The actual case evidence is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The proposed option addresses a different condition: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Confirm the distinction by checking: Inspect service OAM result and remote SAP policy drop counters together. The response supported by the evidence is: A green transport or SDP check cannot establish application reachability through customer filters.
D:The alternative is directed at this separate case: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The present incident is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The pertinent verification is: Inspect service OAM result and remote SAP policy drop counters together. The action or outcome to select here is: A green transport or SDP check cannot establish application reachability through customer filters.
Question 789
A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The engineer wants a safe remedy. Which TWO actions should be paired? (Select TWO.)
- Obtain explicit policy approval and test one known harmless flow before changing security controls.
- Troubleshoot the customer service attachment separately from the operational SDP transport test.
- Distinguish access ports and their SAPs from the provider's network-facing transport ports.
- Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
- Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
Explanation
Correct Answers
A:This safeguard prevents unwanted collateral effects: Obtain explicit policy approval and test one known harmless flow before changing security controls. Its complementary corrective change is: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter. Both are required because: A green transport or SDP check cannot establish application reachability through customer filters.
D:This is the required technical repair: Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter. The separately necessary deployment safeguard is: Obtain explicit policy approval and test one known harmless flow before changing security controls. Together they address: A green transport or SDP check cannot establish application reachability through customer filters.
Incorrect Answers
B:The actual case evidence is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The proposed option addresses a different condition: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Confirm the distinction by checking: Inspect service OAM result and remote SAP policy drop counters together. The response supported by the evidence is: Obtain explicit policy approval and test one known harmless flow before changing security controls; and Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
C:The alternative is directed at this separate case: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The present incident is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The pertinent verification is: Inspect service OAM result and remote SAP policy drop counters together. The action or outcome to select here is: Obtain explicit policy approval and test one known harmless flow before changing security controls; and Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
E:The alternative applies to another situation: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The reported case instead states: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The distinguishing check is: Inspect service OAM result and remote SAP policy drop counters together. The supported action or criterion is: Obtain explicit policy approval and test one known harmless flow before changing security controls; and Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
Question 790
A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Which measurable result would verify success without relying on assumptions?
- The remote attachment comes Up and the Epipe reports end-to-end operational service.
- The contracted customer application passes while unapproved access remains blocked.
- All frames within the contracted size pass from source to remote customer handoff.
- Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
Explanation
Correct Answer
B:The acceptance measurement for this case is: The contracted customer application passes while unapproved access remains blocked. It establishes that the intended remediation (“Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter”) was effective and can be corroborated by: Compare a controlled permitted frame with the actual customer application's encapsulation.
Incorrect Answers
A:The actual case evidence is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The proposed option addresses a different condition: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Confirm the distinction by checking: Inspect service OAM result and remote SAP policy drop counters together. The response supported by the evidence is: The contracted customer application passes while unapproved access remains blocked.
C:This choice does not address the stated situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Its competing context is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The relevant diagnostic is: Inspect service OAM result and remote SAP policy drop counters together. The case-supported response is: The contracted customer application passes while unapproved access remains blocked.
D:The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The distinguishing check is: Inspect service OAM result and remote SAP policy drop counters together. The supported action or criterion is: The contracted customer application passes while unapproved access remains blocked.