Nokia 4A0-C03 Practice Test 77
Question 760
A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. After the approved repair, which outcome best demonstrates that this exact fault is resolved?
- The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.
- Remote PE nodes install a valid VPN service label and customer traffic reaches the CE.
- The MAC resides at one intended site and VPLS unicast forwarding stabilizes.
- The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.
Explanation
Correct Answer
A:The acceptance measurement for this case is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs. It establishes that the intended remediation (“Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding”) was effective and can be corroborated by: Compare bridge membership and routed interface subnet addressing with the customer design.
Incorrect Answers
B:The alternative is directed at this separate case: A local PE learns a customer subnet from the CE but remote sites cannot forward to it because the PE's MP-BGP VPN route is missing a usable service label. The present incident is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The pertinent verification is: Inspect RVPLS interface state and its parent VPLS service identifier. The action or outcome to select here is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.
C:This choice does not address the stated situation: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Its competing context is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The relevant diagnostic is: Inspect RVPLS interface state and its parent VPLS service identifier. The case-supported response is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.
D:The alternative applies to another situation: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The reported case instead states: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The distinguishing check is: Inspect RVPLS interface state and its parent VPLS service identifier. The supported action or criterion is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.
Question 761
Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. An operator needs a controlled repair. Which response is most appropriate?
- Preserve the intended mesh SDP split-horizon behavior and correct the invalid service topology.
- Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards.
- Implement the approved layer-two spoke termination and layer-three service association.
- Align the routed VPLS gateway and redundancy model with the approved architecture.
Explanation
Correct Answer
D:The fault stated in this case is: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The specific corrective action is: Align the routed VPLS gateway and redundancy model with the approved architecture. Confirm it with: Inspect gateway MAC and IP ownership advertisements on both PEs. The expected end-to-end outcome is: The client resolves a stable intended gateway and failover follows the documented design.
Incorrect Answers
A:The alternative is directed at this separate case: A multipoint VPLS configuration attempts to relay a frame received from one mesh SDP toward another mesh SDP, generating duplicate copies in a provider-side ring. The present incident is: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The pertinent verification is: Inspect gateway MAC and IP ownership advertisements on both PEs. The action or outcome to select here is: Align the routed VPLS gateway and redundancy model with the approved architecture.
B:This choice does not address the stated situation: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Its competing context is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The relevant diagnostic is: Inspect gateway MAC and IP ownership advertisements on both PEs. The case-supported response is: Align the routed VPLS gateway and redundancy model with the approved architecture.
C:The alternative applies to another situation: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The reported case instead states: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The distinguishing check is: Inspect gateway MAC and IP ownership advertisements on both PEs. The supported action or criterion is: Align the routed VPLS gateway and redundancy model with the approved architecture.
Question 762
Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Which TWO diagnostic investigations most directly test the cause? (Select TWO.)
- Inspect spoke SDP binding and the routed service interface on the destination PE.
- Compare observed ARP resolution and customer next-hop selection during path changes.
- Inspect per-SDP forwarding decisions for frames arriving from provider tunnel peers.
- Inspect VPN-IPv4 NLRI for both tenants and their RD values.
- Inspect gateway MAC and IP ownership advertisements on both PEs.
Explanation
Correct Answers
B:This is a direct diagnostic for the reported fault: Compare observed ARP resolution and customer next-hop selection during path changes. A second independent check is: Inspect gateway MAC and IP ownership advertisements on both PEs. Combined evidence distinguishes the fault before implementing: Align the routed VPLS gateway and redundancy model with the approved architecture.
E:This is a direct diagnostic for the reported fault: Inspect gateway MAC and IP ownership advertisements on both PEs. A second independent check is: Compare observed ARP resolution and customer next-hop selection during path changes. Combined evidence distinguishes the fault before implementing: Align the routed VPLS gateway and redundancy model with the approved architecture.
Incorrect Answers
A:This choice does not address the stated situation: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Its competing context is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The relevant diagnostic is: Inspect gateway MAC and IP ownership advertisements on both PEs. The case-supported response is: Compare observed ARP resolution and customer next-hop selection during path changes; and Inspect gateway MAC and IP ownership advertisements on both PEs.
C:These other facts could justify the alternative: A multipoint VPLS configuration attempts to relay a frame received from one mesh SDP toward another mesh SDP, generating duplicate copies in a provider-side ring. They differ from the stated case: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Test the distinction using: Inspect gateway MAC and IP ownership advertisements on both PEs. The case-specific response is: Compare observed ARP resolution and customer next-hop selection during path changes; and Inspect gateway MAC and IP ownership advertisements on both PEs.
D:The actual case evidence is: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The proposed option addresses a different condition: Two private routed network customers both use 10.10.0.0/16 but an automation template gives their exported routes the same RD. Confirm the distinction by checking: Inspect gateway MAC and IP ownership advertisements on both PEs. The response supported by the evidence is: Compare observed ARP resolution and customer next-hop selection during path changes; and Inspect gateway MAC and IP ownership advertisements on both PEs.
Question 763
Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Which specific consequence explains why a repair is necessary?
- Uncoordinated duplicate gateways can create MAC flaps and unpredictable customer forwarding.
- Duplicate MAC identities can cause intermittent private-layer-two forwarding and service instability.
- A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
- Disabling provider split horizon can create Ethernet loops and amplify broadcast traffic.
Explanation
Correct Answer
A:The observed condition is: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The principal operational or security impact is: Uncoordinated duplicate gateways can create MAC flaps and unpredictable customer forwarding. The supported repair is: Align the routed VPLS gateway and redundancy model with the approved architecture. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
B:These other facts could justify the alternative: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. They differ from the stated case: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Test the distinction using: Inspect gateway MAC and IP ownership advertisements on both PEs. The case-specific response is: Uncoordinated duplicate gateways can create MAC flaps and unpredictable customer forwarding.
C:The actual case evidence is: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The proposed option addresses a different condition: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Confirm the distinction by checking: Inspect gateway MAC and IP ownership advertisements on both PEs. The response supported by the evidence is: Uncoordinated duplicate gateways can create MAC flaps and unpredictable customer forwarding.
D:The alternative is directed at this separate case: A multipoint VPLS configuration attempts to relay a frame received from one mesh SDP toward another mesh SDP, generating duplicate copies in a provider-side ring. The present incident is: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The pertinent verification is: Inspect gateway MAC and IP ownership advertisements on both PEs. The action or outcome to select here is: Uncoordinated duplicate gateways can create MAC flaps and unpredictable customer forwarding.
Question 764
Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Which TWO actions form both a suitable correction and its necessary change-control safeguard? (Select TWO.)
- Use unique approved route distinguishers so overlapping customer prefixes have distinct VPN identities.
- Preserve the intended mesh SDP split-horizon behavior and correct the invalid service topology.
- Align the routed VPLS gateway and redundancy model with the approved architecture.
- Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
- Model redundant gateway behavior in a lab before changing live service addresses.
Explanation
Correct Answers
C:This is the required technical repair: Align the routed VPLS gateway and redundancy model with the approved architecture. The separately necessary deployment safeguard is: Model redundant gateway behavior in a lab before changing live service addresses. Together they address: Uncoordinated duplicate gateways can create MAC flaps and unpredictable customer forwarding.
E:This safeguard prevents unwanted collateral effects: Model redundant gateway behavior in a lab before changing live service addresses. Its complementary corrective change is: Align the routed VPLS gateway and redundancy model with the approved architecture. Both are required because: Uncoordinated duplicate gateways can create MAC flaps and unpredictable customer forwarding.
Incorrect Answers
A:These other facts could justify the alternative: Two private routed network customers both use 10.10.0.0/16 but an automation template gives their exported routes the same RD. They differ from the stated case: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Test the distinction using: Inspect gateway MAC and IP ownership advertisements on both PEs. The case-specific response is: Align the routed VPLS gateway and redundancy model with the approved architecture; and Model redundant gateway behavior in a lab before changing live service addresses.
B:The actual case evidence is: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The proposed option addresses a different condition: A multipoint VPLS configuration attempts to relay a frame received from one mesh SDP toward another mesh SDP, generating duplicate copies in a provider-side ring. Confirm the distinction by checking: Inspect gateway MAC and IP ownership advertisements on both PEs. The response supported by the evidence is: Align the routed VPLS gateway and redundancy model with the approved architecture; and Model redundant gateway behavior in a lab before changing live service addresses.
D:This choice does not address the stated situation: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Its competing context is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The relevant diagnostic is: Inspect gateway MAC and IP ownership advertisements on both PEs. The case-supported response is: Align the routed VPLS gateway and redundancy model with the approved architecture; and Model redundant gateway behavior in a lab before changing live service addresses.
Question 765
Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Which post-change observation is the strongest acceptance criterion?
- The client resolves a stable intended gateway and failover follows the documented design.
- The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.
- The MAC resides at one intended site and VPLS unicast forwarding stabilizes.
- Frames reach authorized customer SAPs without inappropriate mesh-to-mesh flooding.
Explanation
Correct Answer
A:The acceptance measurement for this case is: The client resolves a stable intended gateway and failover follows the documented design. It establishes that the intended remediation (“Align the routed VPLS gateway and redundancy model with the approved architecture”) was effective and can be corroborated by: Compare observed ARP resolution and customer next-hop selection during path changes.
Incorrect Answers
B:The alternative is directed at this separate case: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The present incident is: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The pertinent verification is: Inspect gateway MAC and IP ownership advertisements on both PEs. The action or outcome to select here is: The client resolves a stable intended gateway and failover follows the documented design.
C:This choice does not address the stated situation: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Its competing context is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The relevant diagnostic is: Inspect gateway MAC and IP ownership advertisements on both PEs. The case-supported response is: The client resolves a stable intended gateway and failover follows the documented design.
D:The alternative applies to another situation: A multipoint VPLS configuration attempts to relay a frame received from one mesh SDP toward another mesh SDP, generating duplicate copies in a provider-side ring. The reported case instead states: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The distinguishing check is: Inspect gateway MAC and IP ownership advertisements on both PEs. The supported action or criterion is: The client resolves a stable intended gateway and failover follows the documented design.
Question 766
A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Which next technical step should the engineer prioritize?
- Implement the approved layer-two spoke termination and layer-three service association.
- Verify MTU at both customer attachment endpoints and the transport service overhead.
- Troubleshoot the customer service attachment separately from the operational SDP transport test.
- Attach the approved IES interface to the proper global routed service context.
Explanation
Correct Answer
A:The fault stated in this case is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The specific corrective action is: Implement the approved layer-two spoke termination and layer-three service association. Confirm it with: Inspect spoke SDP binding and the routed service interface on the destination PE. The expected end-to-end outcome is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.
Incorrect Answers
B:This choice does not address the stated situation: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Its competing context is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The relevant diagnostic is: Inspect spoke SDP binding and the routed service interface on the destination PE. The case-supported response is: Implement the approved layer-two spoke termination and layer-three service association.
C:The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The distinguishing check is: Inspect spoke SDP binding and the routed service interface on the destination PE. The supported action or criterion is: Implement the approved layer-two spoke termination and layer-three service association.
D:These other facts could justify the alternative: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. They differ from the stated case: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Test the distinction using: Inspect spoke SDP binding and the routed service interface on the destination PE. The case-specific response is: Implement the approved layer-two spoke termination and layer-three service association.
Question 767
A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Which TWO items of evidence should the engineer examine first? (Select TWO.)
- Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
- Compare incoming Ethernet encapsulation with expected customer VPRN route membership.
- Inspect the SAP's VLAN tag association and customer ingress discard counters.
- Inspect spoke SDP binding and the routed service interface on the destination PE.
- Inspect SAP-to-service mappings and the destination of synthetic broadcast frames.
Explanation
Correct Answers
B:This is a direct diagnostic for the reported fault: Compare incoming Ethernet encapsulation with expected customer VPRN route membership. A second independent check is: Inspect spoke SDP binding and the routed service interface on the destination PE. Combined evidence distinguishes the fault before implementing: Implement the approved layer-two spoke termination and layer-three service association.
D:This is a direct diagnostic for the reported fault: Inspect spoke SDP binding and the routed service interface on the destination PE. A second independent check is: Compare incoming Ethernet encapsulation with expected customer VPRN route membership. Combined evidence distinguishes the fault before implementing: Implement the approved layer-two spoke termination and layer-three service association.
Incorrect Answers
A:This choice does not address the stated situation: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Its competing context is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The relevant diagnostic is: Inspect spoke SDP binding and the routed service interface on the destination PE. The case-supported response is: Compare incoming Ethernet encapsulation with expected customer VPRN route membership; and Inspect spoke SDP binding and the routed service interface on the destination PE.
C:These other facts could justify the alternative: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. They differ from the stated case: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Test the distinction using: Inspect spoke SDP binding and the routed service interface on the destination PE. The case-specific response is: Compare incoming Ethernet encapsulation with expected customer VPRN route membership; and Inspect spoke SDP binding and the routed service interface on the destination PE.
E:The alternative is directed at this separate case: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The present incident is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The pertinent verification is: Inspect spoke SDP binding and the routed service interface on the destination PE. The action or outcome to select here is: Compare incoming Ethernet encapsulation with expected customer VPRN route membership; and Inspect spoke SDP binding and the routed service interface on the destination PE.
Question 768
A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. If the condition is left unresolved, which operational consequence is most directly at risk?
- Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.
- Transport OAM success does not guarantee correct attachment or customer encapsulation.
- Confusing IES with VPRN can cause missing reachability or unintended private-route exposure.
- A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
Explanation
Correct Answer
D:The observed condition is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The principal operational or security impact is: A correctly transported L2 circuit does not by itself create the intended routed VPN termination. The supported repair is: Implement the approved layer-two spoke termination and layer-three service association. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The reported case instead states: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The distinguishing check is: Inspect spoke SDP binding and the routed service interface on the destination PE. The supported action or criterion is: A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
B:These other facts could justify the alternative: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. They differ from the stated case: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Test the distinction using: Inspect spoke SDP binding and the routed service interface on the destination PE. The case-specific response is: A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
C:The actual case evidence is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The proposed option addresses a different condition: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. Confirm the distinction by checking: Inspect spoke SDP binding and the routed service interface on the destination PE. The response supported by the evidence is: A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
Question 769
A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The engineer wants a safe remedy. Which TWO actions should be paired? (Select TWO.)
- Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding.
- Validate service ownership and introduce one test subnet without crossing tenant boundaries.
- Troubleshoot the customer service attachment separately from the operational SDP transport test.
- Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
- Implement the approved layer-two spoke termination and layer-three service association.
Explanation
Correct Answers
B:This safeguard prevents unwanted collateral effects: Validate service ownership and introduce one test subnet without crossing tenant boundaries. Its complementary corrective change is: Implement the approved layer-two spoke termination and layer-three service association. Both are required because: A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
E:This is the required technical repair: Implement the approved layer-two spoke termination and layer-three service association. The separately necessary deployment safeguard is: Validate service ownership and introduce one test subnet without crossing tenant boundaries. Together they address: A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
Incorrect Answers
A:These other facts could justify the alternative: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. They differ from the stated case: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Test the distinction using: Inspect spoke SDP binding and the routed service interface on the destination PE. The case-specific response is: Validate service ownership and introduce one test subnet without crossing tenant boundaries; and Implement the approved layer-two spoke termination and layer-three service association.
C:The alternative is directed at this separate case: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The present incident is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The pertinent verification is: Inspect spoke SDP binding and the routed service interface on the destination PE. The action or outcome to select here is: Validate service ownership and introduce one test subnet without crossing tenant boundaries; and Implement the approved layer-two spoke termination and layer-three service association.
D:This choice does not address the stated situation: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Its competing context is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The relevant diagnostic is: Inspect spoke SDP binding and the routed service interface on the destination PE. The case-supported response is: Validate service ownership and introduce one test subnet without crossing tenant boundaries; and Implement the approved layer-two spoke termination and layer-three service association.
Question 770
A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Which measurable result would verify success without relying on assumptions?
- The subscriber obtains intended shared routed connectivity with no unauthorized VPN imports.
- All frames within the contracted size pass from source to remote customer handoff.
- The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.
- Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
Explanation
Correct Answer
C:The acceptance measurement for this case is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes. It establishes that the intended remediation (“Implement the approved layer-two spoke termination and layer-three service association”) was effective and can be corroborated by: Compare incoming Ethernet encapsulation with expected customer VPRN route membership.
Incorrect Answers
A:The actual case evidence is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The proposed option addresses a different condition: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. Confirm the distinction by checking: Inspect spoke SDP binding and the routed service interface on the destination PE. The response supported by the evidence is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.
B:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The pertinent verification is: Inspect spoke SDP binding and the routed service interface on the destination PE. The action or outcome to select here is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.
D:The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The distinguishing check is: Inspect spoke SDP binding and the routed service interface on the destination PE. The supported action or criterion is: The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.