cert
cert-1
cert-2

Pass Nokia 4A0-C03 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
4A0-C03 Exam - Verified By Experts
4A0-C03 Premium File

4A0-C03 Premium File

$69.99
$76.99
  • Premium File 145 Questions & Answers. Last Update: Nov 23, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Nokia 4A0-C03 Practice Test 76

Question 750

A copied RT import policy lets one enterprise's private subnet appear inside another tenant's VPRN route table during a provisioning rollout. Which measurable result would verify success without relying on assumptions?

  1. The private prefix remains only in its authorized VPRN and global routing stays unaffected.
  2. A VPRN-scoped probe reaches the intended customer endpoint while other tenants remain isolated.
  3. Both customers retain independent VPN prefixes and correct isolated route lookup.
  4. Each tenant sees only its own authorized routes and cross-tenant forwarding is blocked.

Explanation

Correct Answer

D:

The acceptance measurement for this case is: Each tenant sees only its own authorized routes and cross-tenant forwarding is blocked. It establishes that the intended remediation (“Remove the unauthorized import membership and restore strict per-tenant VPN separation”) was effective and can be corroborated by: Compare customer service identity and assigned route targets with approved access records.

Incorrect Answers

A:

The actual case evidence is: A copied RT import policy lets one enterprise's private subnet appear inside another tenant's VPRN route table during a provisioning rollout. The proposed option addresses a different condition: An operations audit finds a private customer /24 installed in the Nokia base IP route table because a service-specific redistribution rule was applied globally. Confirm the distinction by checking: Inspect the unexpected VPN route's RT attributes and destination VPRN import policy. The response supported by the evidence is: Each tenant sees only its own authorized routes and cross-tenant forwarding is blocked.

B:

The alternative is directed at this separate case: A technician tests a VPRN using a base-routing-table ICMP probe to a private customer IP and assumes the remote tenant is unreachable. The present incident is: A copied RT import policy lets one enterprise's private subnet appear inside another tenant's VPRN route table during a provisioning rollout. The pertinent verification is: Inspect the unexpected VPN route's RT attributes and destination VPRN import policy. The action or outcome to select here is: Each tenant sees only its own authorized routes and cross-tenant forwarding is blocked.

C:

This choice does not address the stated situation: A copied RT import policy lets one enterprise's private subnet appear inside another tenant's VPRN route table during a provisioning rollout. Its competing context is: Two private routed network customers both use 10.10.0.0/16 but an automation template gives their exported routes the same RD. The relevant diagnostic is: Inspect the unexpected VPN route's RT attributes and destination VPRN import policy. The case-supported response is: Each tenant sees only its own authorized routes and cross-tenant forwarding is blocked.

Question 751

A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Which change most directly addresses the observed problem?

  1. Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards.
  2. Use unique approved route distinguishers so overlapping customer prefixes have distinct VPN identities.
  3. Choose the single contracted routing service association and remove the conflicting attachment.
  4. Run the approved service-aware OAM probe in the correct customer routing instance.

Explanation

Correct Answer

C:

The fault stated in this case is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The specific corrective action is: Choose the single contracted routing service association and remove the conflicting attachment. Confirm it with: Inspect active SAP-to-service associations and routing instance membership. The expected end-to-end outcome is: The interface belongs to the authorized service only and its routing behavior matches the contract.

Incorrect Answers

A:

The alternative is directed at this separate case: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The present incident is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The pertinent verification is: Inspect active SAP-to-service associations and routing instance membership. The action or outcome to select here is: Choose the single contracted routing service association and remove the conflicting attachment.

B:

This choice does not address the stated situation: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Its competing context is: Two private routed network customers both use 10.10.0.0/16 but an automation template gives their exported routes the same RD. The relevant diagnostic is: Inspect active SAP-to-service associations and routing instance membership. The case-supported response is: Choose the single contracted routing service association and remove the conflicting attachment.

D:

These other facts could justify the alternative: A technician tests a VPRN using a base-routing-table ICMP probe to a private customer IP and assumes the remote tenant is unreachable. They differ from the stated case: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Test the distinction using: Inspect active SAP-to-service associations and routing instance membership. The case-specific response is: Choose the single contracted routing service association and remove the conflicting attachment.

Question 752

A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Which TWO independent checks would best establish what is happening? (Select TWO.)

  1. Inspect base and customer route tables for the same private prefix and its origin policy.
  2. Inspect active SAP-to-service associations and routing instance membership.
  3. Inspect VPN-IPv4 NLRI for both tenants and their RD values.
  4. Inspect service identifier and routing context used by the failed probe.
  5. Compare intended public versus private service topology with customer provisioning records.

Explanation

Correct Answers

B:

This is a direct diagnostic for the reported fault: Inspect active SAP-to-service associations and routing instance membership. A second independent check is: Compare intended public versus private service topology with customer provisioning records. Combined evidence distinguishes the fault before implementing: Choose the single contracted routing service association and remove the conflicting attachment.

E:

This is a direct diagnostic for the reported fault: Compare intended public versus private service topology with customer provisioning records. A second independent check is: Inspect active SAP-to-service associations and routing instance membership. Combined evidence distinguishes the fault before implementing: Choose the single contracted routing service association and remove the conflicting attachment.

Incorrect Answers

A:

This choice does not address the stated situation: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Its competing context is: An operations audit finds a private customer /24 installed in the Nokia base IP route table because a service-specific redistribution rule was applied globally. The relevant diagnostic is: Inspect active SAP-to-service associations and routing instance membership. The case-supported response is: Inspect active SAP-to-service associations and routing instance membership; and Compare intended public versus private service topology with customer provisioning records.

C:

These other facts could justify the alternative: Two private routed network customers both use 10.10.0.0/16 but an automation template gives their exported routes the same RD. They differ from the stated case: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Test the distinction using: Inspect active SAP-to-service associations and routing instance membership. The case-specific response is: Inspect active SAP-to-service associations and routing instance membership; and Compare intended public versus private service topology with customer provisioning records.

D:

The actual case evidence is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The proposed option addresses a different condition: A technician tests a VPRN using a base-routing-table ICMP probe to a private customer IP and assumes the remote tenant is unreachable. Confirm the distinction by checking: Inspect active SAP-to-service associations and routing instance membership. The response supported by the evidence is: Inspect active SAP-to-service associations and routing instance membership; and Compare intended public versus private service topology with customer provisioning records.

Question 753

A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. What is the key technical or security failure this situation can produce?

  1. Mixing shared internet and private VPN contexts can break routing or expose sensitive prefixes.
  2. Overlapping RDs can make identically numbered VPN prefixes collide in the shared control plane.
  3. A test from the wrong routing context can report a false outage or invite unsafe route leaking.
  4. Duplicate MAC identities can cause intermittent private-layer-two forwarding and service instability.

Explanation

Correct Answer

A:

The observed condition is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The principal operational or security impact is: Mixing shared internet and private VPN contexts can break routing or expose sensitive prefixes. The supported repair is: Choose the single contracted routing service association and remove the conflicting attachment. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

B:

These other facts could justify the alternative: Two private routed network customers both use 10.10.0.0/16 but an automation template gives their exported routes the same RD. They differ from the stated case: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Test the distinction using: Inspect active SAP-to-service associations and routing instance membership. The case-specific response is: Mixing shared internet and private VPN contexts can break routing or expose sensitive prefixes.

C:

The actual case evidence is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The proposed option addresses a different condition: A technician tests a VPRN using a base-routing-table ICMP probe to a private customer IP and assumes the remote tenant is unreachable. Confirm the distinction by checking: Inspect active SAP-to-service associations and routing instance membership. The response supported by the evidence is: Mixing shared internet and private VPN contexts can break routing or expose sensitive prefixes.

D:

The alternative is directed at this separate case: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The present incident is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The pertinent verification is: Inspect active SAP-to-service associations and routing instance membership. The action or outcome to select here is: Mixing shared internet and private VPN contexts can break routing or expose sensitive prefixes.

Question 754

A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Choose TWO complementary steps: one repair and one precaution against collateral impact. (Select TWO.)

  1. Remove the unintended global route leak and restore the contracted VPRN route context.
  2. Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
  3. Use unique approved route distinguishers so overlapping customer prefixes have distinct VPN identities.
  4. Change one isolated service instance with explicit customer authorization.
  5. Choose the single contracted routing service association and remove the conflicting attachment.

Explanation

Correct Answers

D:

This safeguard prevents unwanted collateral effects: Change one isolated service instance with explicit customer authorization. Its complementary corrective change is: Choose the single contracted routing service association and remove the conflicting attachment. Both are required because: Mixing shared internet and private VPN contexts can break routing or expose sensitive prefixes.

E:

This is the required technical repair: Choose the single contracted routing service association and remove the conflicting attachment. The separately necessary deployment safeguard is: Change one isolated service instance with explicit customer authorization. Together they address: Mixing shared internet and private VPN contexts can break routing or expose sensitive prefixes.

Incorrect Answers

A:

These other facts could justify the alternative: An operations audit finds a private customer /24 installed in the Nokia base IP route table because a service-specific redistribution rule was applied globally. They differ from the stated case: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Test the distinction using: Inspect active SAP-to-service associations and routing instance membership. The case-specific response is: Change one isolated service instance with explicit customer authorization; and Choose the single contracted routing service association and remove the conflicting attachment.

B:

The actual case evidence is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The proposed option addresses a different condition: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Confirm the distinction by checking: Inspect active SAP-to-service associations and routing instance membership. The response supported by the evidence is: Change one isolated service instance with explicit customer authorization; and Choose the single contracted routing service association and remove the conflicting attachment.

C:

The alternative is directed at this separate case: Two private routed network customers both use 10.10.0.0/16 but an automation template gives their exported routes the same RD. The present incident is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The pertinent verification is: Inspect active SAP-to-service associations and routing instance membership. The action or outcome to select here is: Change one isolated service instance with explicit customer authorization; and Choose the single contracted routing service association and remove the conflicting attachment.

Question 755

A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. What evidence would demonstrate that the intended fix worked correctly?

  1. Both customers retain independent VPN prefixes and correct isolated route lookup.
  2. The interface belongs to the authorized service only and its routing behavior matches the contract.
  3. The MAC resides at one intended site and VPLS unicast forwarding stabilizes.
  4. A VPRN-scoped probe reaches the intended customer endpoint while other tenants remain isolated.

Explanation

Correct Answer

B:

The acceptance measurement for this case is: The interface belongs to the authorized service only and its routing behavior matches the contract. It establishes that the intended remediation (“Choose the single contracted routing service association and remove the conflicting attachment”) was effective and can be corroborated by: Compare intended public versus private service topology with customer provisioning records.

Incorrect Answers

A:

The actual case evidence is: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The proposed option addresses a different condition: Two private routed network customers both use 10.10.0.0/16 but an automation template gives their exported routes the same RD. Confirm the distinction by checking: Inspect active SAP-to-service associations and routing instance membership. The response supported by the evidence is: The interface belongs to the authorized service only and its routing behavior matches the contract.

C:

This choice does not address the stated situation: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Its competing context is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The relevant diagnostic is: Inspect active SAP-to-service associations and routing instance membership. The case-supported response is: The interface belongs to the authorized service only and its routing behavior matches the contract.

D:

The alternative applies to another situation: A technician tests a VPRN using a base-routing-table ICMP probe to a private customer IP and assumes the remote tenant is unreachable. The reported case instead states: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. The distinguishing check is: Inspect active SAP-to-service associations and routing instance membership. The supported action or criterion is: The interface belongs to the authorized service only and its routing behavior matches the contract.

Question 756

A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Which corrective action best resolves this particular network fault?

  1. Restore supported per-VPN service label advertisement and egress forwarding state.
  2. Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards.
  3. Implement the approved layer-two spoke termination and layer-three service association.
  4. Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding.

Explanation

Correct Answer

D:

The fault stated in this case is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The specific corrective action is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding. Confirm it with: Inspect RVPLS interface state and its parent VPLS service identifier. The expected end-to-end outcome is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.

Incorrect Answers

A:

The alternative is directed at this separate case: A local PE learns a customer subnet from the CE but remote sites cannot forward to it because the PE's MP-BGP VPN route is missing a usable service label. The present incident is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The pertinent verification is: Inspect RVPLS interface state and its parent VPLS service identifier. The action or outcome to select here is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding.

B:

This choice does not address the stated situation: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Its competing context is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The relevant diagnostic is: Inspect RVPLS interface state and its parent VPLS service identifier. The case-supported response is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding.

C:

The alternative applies to another situation: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The reported case instead states: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The distinguishing check is: Inspect RVPLS interface state and its parent VPLS service identifier. The supported action or criterion is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding.

Question 757

A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Before proposing a change, which TWO observations would give the most useful confirmation? (Select TWO.)

  1. Inspect MP-BGP labeled VPN NLRI and the PE service-label table.
  2. Inspect gateway MAC and IP ownership advertisements on both PEs.
  3. Inspect RVPLS interface state and its parent VPLS service identifier.
  4. Inspect spoke SDP binding and the routed service interface on the destination PE.
  5. Compare bridge membership and routed interface subnet addressing with the customer design.

Explanation

Correct Answers

C:

This is a direct diagnostic for the reported fault: Inspect RVPLS interface state and its parent VPLS service identifier. A second independent check is: Compare bridge membership and routed interface subnet addressing with the customer design. Combined evidence distinguishes the fault before implementing: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding.

E:

This is a direct diagnostic for the reported fault: Compare bridge membership and routed interface subnet addressing with the customer design. A second independent check is: Inspect RVPLS interface state and its parent VPLS service identifier. Combined evidence distinguishes the fault before implementing: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding.

Incorrect Answers

A:

This choice does not address the stated situation: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Its competing context is: A local PE learns a customer subnet from the CE but remote sites cannot forward to it because the PE's MP-BGP VPN route is missing a usable service label. The relevant diagnostic is: Inspect RVPLS interface state and its parent VPLS service identifier. The case-supported response is: Inspect RVPLS interface state and its parent VPLS service identifier; and Compare bridge membership and routed interface subnet addressing with the customer design.

B:

The alternative applies to another situation: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The reported case instead states: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The distinguishing check is: Inspect RVPLS interface state and its parent VPLS service identifier. The supported action or criterion is: Inspect RVPLS interface state and its parent VPLS service identifier; and Compare bridge membership and routed interface subnet addressing with the customer design.

D:

The actual case evidence is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The proposed option addresses a different condition: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. Confirm the distinction by checking: Inspect RVPLS interface state and its parent VPLS service identifier. The response supported by the evidence is: Inspect RVPLS interface state and its parent VPLS service identifier; and Compare bridge membership and routed interface subnet addressing with the customer design.

Question 758

A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Which statement best describes the immediate risk of ignoring this problem?

  1. Duplicate MAC identities can cause intermittent private-layer-two forwarding and service instability.
  2. A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
  3. CE-to-PE reachability does not guarantee usable provider-to-provider customer forwarding.
  4. Without an appropriate routed attachment, customer VLANs may bridge locally but not reach routed networks.

Explanation

Correct Answer

D:

The observed condition is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The principal operational or security impact is: Without an appropriate routed attachment, customer VLANs may bridge locally but not reach routed networks. The supported repair is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The reported case instead states: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The distinguishing check is: Inspect RVPLS interface state and its parent VPLS service identifier. The supported action or criterion is: Without an appropriate routed attachment, customer VLANs may bridge locally but not reach routed networks.

B:

These other facts could justify the alternative: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. They differ from the stated case: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Test the distinction using: Inspect RVPLS interface state and its parent VPLS service identifier. The case-specific response is: Without an appropriate routed attachment, customer VLANs may bridge locally but not reach routed networks.

C:

The actual case evidence is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The proposed option addresses a different condition: A local PE learns a customer subnet from the CE but remote sites cannot forward to it because the PE's MP-BGP VPN route is missing a usable service label. Confirm the distinction by checking: Inspect RVPLS interface state and its parent VPLS service identifier. The response supported by the evidence is: Without an appropriate routed attachment, customer VLANs may bridge locally but not reach routed networks.

Question 759

A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Which TWO measures together address the fault while protecting other services? (Select TWO.)

  1. Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding.
  2. Align the routed VPLS gateway and redundancy model with the approved architecture.
  3. Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
  4. Test a synthetic host on each side and preserve tenant-specific filtering.
  5. Implement the approved layer-two spoke termination and layer-three service association.

Explanation

Correct Answers

A:

This is the required technical repair: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding. The separately necessary deployment safeguard is: Test a synthetic host on each side and preserve tenant-specific filtering. Together they address: Without an appropriate routed attachment, customer VLANs may bridge locally but not reach routed networks.

D:

This safeguard prevents unwanted collateral effects: Test a synthetic host on each side and preserve tenant-specific filtering. Its complementary corrective change is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding. Both are required because: Without an appropriate routed attachment, customer VLANs may bridge locally but not reach routed networks.

Incorrect Answers

B:

The actual case evidence is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The proposed option addresses a different condition: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Confirm the distinction by checking: Inspect RVPLS interface state and its parent VPLS service identifier. The response supported by the evidence is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding; and Test a synthetic host on each side and preserve tenant-specific filtering.

C:

The alternative is directed at this separate case: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The present incident is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The pertinent verification is: Inspect RVPLS interface state and its parent VPLS service identifier. The action or outcome to select here is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding; and Test a synthetic host on each side and preserve tenant-specific filtering.

E:

The alternative applies to another situation: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The reported case instead states: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The distinguishing check is: Inspect RVPLS interface state and its parent VPLS service identifier. The supported action or criterion is: Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding; and Test a synthetic host on each side and preserve tenant-specific filtering.

Question 760

A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. After the approved repair, which outcome best demonstrates that this exact fault is resolved?

  1. The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.
  2. Remote PE nodes install a valid VPN service label and customer traffic reaches the CE.
  3. The MAC resides at one intended site and VPLS unicast forwarding stabilizes.
  4. The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.

Explanation

Correct Answer

A:

The acceptance measurement for this case is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs. It establishes that the intended remediation (“Bind the authorized routed VPLS interface to the correct service and verify L2-to-L3 forwarding”) was effective and can be corroborated by: Compare bridge membership and routed interface subnet addressing with the customer design.

Incorrect Answers

B:

The alternative is directed at this separate case: A local PE learns a customer subnet from the CE but remote sites cannot forward to it because the PE's MP-BGP VPN route is missing a usable service label. The present incident is: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The pertinent verification is: Inspect RVPLS interface state and its parent VPLS service identifier. The action or outcome to select here is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.

C:

This choice does not address the stated situation: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. Its competing context is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The relevant diagnostic is: Inspect RVPLS interface state and its parent VPLS service identifier. The case-supported response is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.

D:

The alternative applies to another situation: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The reported case instead states: A customer asks to route between two segments within a VPLS domain, but the expected routed VPLS interface is not attached to the intended bridged service. The distinguishing check is: Inspect RVPLS interface state and its parent VPLS service identifier. The supported action or criterion is: The approved customer subnets route through the RVPLS interface without leaking unrelated VLANs.

Nokia NRS II Composite: IS-IS version (4A0-C03) Practice Tests