cert
cert-1
cert-2

Pass Nokia 4A0-C03 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
4A0-C03 Exam - Verified By Experts
4A0-C03 Premium File

4A0-C03 Premium File

$69.99
$76.99
  • Premium File 145 Questions & Answers. Last Update: Nov 23, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Nokia 4A0-C03 Practice Test 67

Question 660

A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. After the approved repair, which outcome best demonstrates that this exact fault is resolved?

  1. The interface belongs to the authorized service only and its routing behavior matches the contract.
  2. Observed spoke traffic follows the authorized hub path and meets documented latency expectations.
  3. The MAC resides at one intended site and VPLS unicast forwarding stabilizes.
  4. The client resolves a stable intended gateway and failover follows the documented design.

Explanation

Correct Answer

C:

The acceptance measurement for this case is: The MAC resides at one intended site and VPLS unicast forwarding stabilizes. It establishes that the intended remediation (“Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards”) was effective and can be corroborated by: Compare source MAC configuration on each cloned appliance and site switch.

Incorrect Answers

A:

The actual case evidence is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The proposed option addresses a different condition: A service designer attaches the same customer-facing logical interface to incompatible IES and private VPRN service contexts, causing ambiguous routing. Confirm the distinction by checking: Inspect MAC move records and remote endpoint identities associated with the address. The response supported by the evidence is: The MAC resides at one intended site and VPLS unicast forwarding stabilizes.

B:

The alternative is directed at this separate case: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The present incident is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The pertinent verification is: Inspect MAC move records and remote endpoint identities associated with the address. The action or outcome to select here is: The MAC resides at one intended site and VPLS unicast forwarding stabilizes.

D:

The alternative applies to another situation: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. The reported case instead states: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The distinguishing check is: Inspect MAC move records and remote endpoint identities associated with the address. The supported action or criterion is: The MAC resides at one intended site and VPLS unicast forwarding stabilizes.

Question 661

A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. An operator needs a controlled repair. Which response is most appropriate?

  1. Recognize normal unknown-unicast handling and verify MAC learning before diagnosing a permanent forwarding error.
  2. Allow only the contracted customer's route-target import in the destination VPRN.
  3. Repair the specific remote SDP flood-list membership for the contracted VPLS topology.
  4. Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.

Explanation

Correct Answer

C:

The fault stated in this case is: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The specific corrective action is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology. Confirm it with: Inspect unknown destination flood entries and active SDP states for all three sites. The expected end-to-end outcome is: All three authorized sites receive required initial discovery frames without cross-tenant exposure.

Incorrect Answers

A:

The alternative is directed at this separate case: A new destination MAC is absent from the VPLS forwarding database and the first synthetic unicast frame is flooded to authorized members, alarming a junior engineer. The present incident is: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The pertinent verification is: Inspect unknown destination flood entries and active SDP states for all three sites. The action or outcome to select here is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology.

B:

This choice does not address the stated situation: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Its competing context is: A branch provider edge receives MP-BGP VPN routes but a newly installed site lacks its intended LAN prefix because the site's VPRN import RT list is incomplete. The relevant diagnostic is: Inspect unknown destination flood entries and active SDP states for all three sites. The case-supported response is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology.

D:

These other facts could justify the alternative: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. They differ from the stated case: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Test the distinction using: Inspect unknown destination flood entries and active SDP states for all three sites. The case-specific response is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology.

Question 662

A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Which TWO diagnostic investigations most directly test the cause? (Select TWO.)

  1. Inspect unknown destination flood entries and active SDP states for all three sites.
  2. Inspect missing route RT values and remote import-policy match results.
  3. Inspect gateway MAC and IP ownership advertisements on both PEs.
  4. Inspect service OAM result and remote SAP policy drop counters together.
  5. Compare member SAP and SDP inventories with the intended multipoint service configuration.

Explanation

Correct Answers

A:

This is a direct diagnostic for the reported fault: Inspect unknown destination flood entries and active SDP states for all three sites. A second independent check is: Compare member SAP and SDP inventories with the intended multipoint service configuration. Combined evidence distinguishes the fault before implementing: Repair the specific remote SDP flood-list membership for the contracted VPLS topology.

E:

This is a direct diagnostic for the reported fault: Compare member SAP and SDP inventories with the intended multipoint service configuration. A second independent check is: Inspect unknown destination flood entries and active SDP states for all three sites. Combined evidence distinguishes the fault before implementing: Repair the specific remote SDP flood-list membership for the contracted VPLS topology.

Incorrect Answers

B:

The alternative applies to another situation: A branch provider edge receives MP-BGP VPN routes but a newly installed site lacks its intended LAN prefix because the site's VPRN import RT list is incomplete. The reported case instead states: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The distinguishing check is: Inspect unknown destination flood entries and active SDP states for all three sites. The supported action or criterion is: Inspect unknown destination flood entries and active SDP states for all three sites; and Compare member SAP and SDP inventories with the intended multipoint service configuration.

C:

These other facts could justify the alternative: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. They differ from the stated case: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Test the distinction using: Inspect unknown destination flood entries and active SDP states for all three sites. The case-specific response is: Inspect unknown destination flood entries and active SDP states for all three sites; and Compare member SAP and SDP inventories with the intended multipoint service configuration.

D:

The actual case evidence is: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Inspect unknown destination flood entries and active SDP states for all three sites. The response supported by the evidence is: Inspect unknown destination flood entries and active SDP states for all three sites; and Compare member SAP and SDP inventories with the intended multipoint service configuration.

Question 663

A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Which specific consequence explains why a repair is necessary?

  1. A green transport or SDP check cannot establish application reachability through customer filters.
  2. Incomplete flooding can prevent remote ARP or MAC learning while other unicast flows still work.
  3. An RT mismatch can isolate a remote VPRN location without any MPLS transport fault.
  4. Confusing unknown-unicast flooding with a design fault can cause unnecessary service filtering.

Explanation

Correct Answer

B:

The observed condition is: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The principal operational or security impact is: Incomplete flooding can prevent remote ARP or MAC learning while other unicast flows still work. The supported repair is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The reported case instead states: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The distinguishing check is: Inspect unknown destination flood entries and active SDP states for all three sites. The supported action or criterion is: Incomplete flooding can prevent remote ARP or MAC learning while other unicast flows still work.

C:

The actual case evidence is: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The proposed option addresses a different condition: A branch provider edge receives MP-BGP VPN routes but a newly installed site lacks its intended LAN prefix because the site's VPRN import RT list is incomplete. Confirm the distinction by checking: Inspect unknown destination flood entries and active SDP states for all three sites. The response supported by the evidence is: Incomplete flooding can prevent remote ARP or MAC learning while other unicast flows still work.

D:

The alternative is directed at this separate case: A new destination MAC is absent from the VPLS forwarding database and the first synthetic unicast frame is flooded to authorized members, alarming a junior engineer. The present incident is: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The pertinent verification is: Inspect unknown destination flood entries and active SDP states for all three sites. The action or outcome to select here is: Incomplete flooding can prevent remote ARP or MAC learning while other unicast flows still work.

Question 664

A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Which TWO actions form both a suitable correction and its necessary change-control safeguard? (Select TWO.)

  1. Repair the specific remote SDP flood-list membership for the contracted VPLS topology.
  2. Align the routed VPLS gateway and redundancy model with the approved architecture.
  3. Use a low-rate synthetic broadcast and avoid expanding the flood domain to other customers.
  4. Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
  5. Update the approved remote PE endpoint and transport resolution for the affected service distribution point.

Explanation

Correct Answers

A:

This is the required technical repair: Repair the specific remote SDP flood-list membership for the contracted VPLS topology. The separately necessary deployment safeguard is: Use a low-rate synthetic broadcast and avoid expanding the flood domain to other customers. Together they address: Incomplete flooding can prevent remote ARP or MAC learning while other unicast flows still work.

C:

This safeguard prevents unwanted collateral effects: Use a low-rate synthetic broadcast and avoid expanding the flood domain to other customers. Its complementary corrective change is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology. Both are required because: Incomplete flooding can prevent remote ARP or MAC learning while other unicast flows still work.

Incorrect Answers

B:

The actual case evidence is: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The proposed option addresses a different condition: Two PEs independently configure the same RVPLS gateway identity without an approved resiliency design, creating unstable ARP and traffic paths. Confirm the distinction by checking: Inspect unknown destination flood entries and active SDP states for all three sites. The response supported by the evidence is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology; and Use a low-rate synthetic broadcast and avoid expanding the flood domain to other customers.

D:

This choice does not address the stated situation: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Its competing context is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The relevant diagnostic is: Inspect unknown destination flood entries and active SDP states for all three sites. The case-supported response is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology; and Use a low-rate synthetic broadcast and avoid expanding the flood domain to other customers.

E:

The alternative applies to another situation: A multipoint Nokia VPN is healthy at its local access ports but its SDP references a remote provider edge removed during a metro replacement. The reported case instead states: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The distinguishing check is: Inspect unknown destination flood entries and active SDP states for all three sites. The supported action or criterion is: Repair the specific remote SDP flood-list membership for the contracted VPLS topology; and Use a low-rate synthetic broadcast and avoid expanding the flood domain to other customers.

Question 665

A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Which post-change observation is the strongest acceptance criterion?

  1. All three authorized sites receive required initial discovery frames without cross-tenant exposure.
  2. The authorized branch LAN route installs in the correct VPRN and the tenant stays isolated.
  3. The contracted customer application passes while unapproved access remains blocked.
  4. After learning, the destination's frames forward only along the correct VPLS attachment.

Explanation

Correct Answer

A:

The acceptance measurement for this case is: All three authorized sites receive required initial discovery frames without cross-tenant exposure. It establishes that the intended remediation (“Repair the specific remote SDP flood-list membership for the contracted VPLS topology”) was effective and can be corroborated by: Compare member SAP and SDP inventories with the intended multipoint service configuration.

Incorrect Answers

B:

The alternative is directed at this separate case: A branch provider edge receives MP-BGP VPN routes but a newly installed site lacks its intended LAN prefix because the site's VPRN import RT list is incomplete. The present incident is: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The pertinent verification is: Inspect unknown destination flood entries and active SDP states for all three sites. The action or outcome to select here is: All three authorized sites receive required initial discovery frames without cross-tenant exposure.

C:

This choice does not address the stated situation: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Its competing context is: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The relevant diagnostic is: Inspect unknown destination flood entries and active SDP states for all three sites. The case-supported response is: All three authorized sites receive required initial discovery frames without cross-tenant exposure.

D:

The alternative applies to another situation: A new destination MAC is absent from the VPLS forwarding database and the first synthetic unicast frame is flooded to authorized members, alarming a junior engineer. The reported case instead states: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The distinguishing check is: Inspect unknown destination flood entries and active SDP states for all three sites. The supported action or criterion is: All three authorized sites receive required initial discovery frames without cross-tenant exposure.

Question 666

A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Which next technical step should the engineer prioritize?

  1. Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
  2. Restore the intended service administrative state after confirming maintenance authorization.
  3. Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards.
  4. Recognize dynamic MAC aging and confirm attachment state before declaring service failure.

Explanation

Correct Answer

D:

The fault stated in this case is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The specific corrective action is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure. Confirm it with: Inspect forwarding database aging timers and the current learned location. The expected end-to-end outcome is: The expected MAC is relearned on the correct site while the service stays operational.

Incorrect Answers

A:

The alternative is directed at this separate case: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The present incident is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The pertinent verification is: Inspect forwarding database aging timers and the current learned location. The action or outcome to select here is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure.

B:

This choice does not address the stated situation: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Its competing context is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The relevant diagnostic is: Inspect forwarding database aging timers and the current learned location. The case-supported response is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure.

C:

The alternative applies to another situation: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The reported case instead states: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The distinguishing check is: Inspect forwarding database aging timers and the current learned location. The supported action or criterion is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure.

Question 667

A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Which TWO items of evidence should the engineer examine first? (Select TWO.)

  1. Inspect forwarding database aging timers and the current learned location.
  2. Inspect MAC move records and remote endpoint identities associated with the address.
  3. Generate one controlled frame from the authorized branch and observe new learning.
  4. Compare permitted customer frame size with every core link MTU and label count.
  5. Inspect the Epipe admin and oper status alongside physical port state.

Explanation

Correct Answers

A:

This is a direct diagnostic for the reported fault: Inspect forwarding database aging timers and the current learned location. A second independent check is: Generate one controlled frame from the authorized branch and observe new learning. Combined evidence distinguishes the fault before implementing: Recognize dynamic MAC aging and confirm attachment state before declaring service failure.

C:

This is a direct diagnostic for the reported fault: Generate one controlled frame from the authorized branch and observe new learning. A second independent check is: Inspect forwarding database aging timers and the current learned location. Combined evidence distinguishes the fault before implementing: Recognize dynamic MAC aging and confirm attachment state before declaring service failure.

Incorrect Answers

B:

The alternative applies to another situation: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The reported case instead states: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The distinguishing check is: Inspect forwarding database aging timers and the current learned location. The supported action or criterion is: Inspect forwarding database aging timers and the current learned location; and Generate one controlled frame from the authorized branch and observe new learning.

D:

The actual case evidence is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The proposed option addresses a different condition: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Confirm the distinction by checking: Inspect forwarding database aging timers and the current learned location. The response supported by the evidence is: Inspect forwarding database aging timers and the current learned location; and Generate one controlled frame from the authorized branch and observe new learning.

E:

The alternative is directed at this separate case: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The present incident is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The pertinent verification is: Inspect forwarding database aging timers and the current learned location. The action or outcome to select here is: Inspect forwarding database aging timers and the current learned location; and Generate one controlled frame from the authorized branch and observe new learning.

Question 668

A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. If the condition is left unresolved, which operational consequence is most directly at risk?

  1. An aged MAC entry alone is not proof of failed transport or endpoint hardware.
  2. A healthy interface cannot carry private-wire traffic through a disabled service instance.
  3. Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors.
  4. Duplicate MAC identities can cause intermittent private-layer-two forwarding and service instability.

Explanation

Correct Answer

A:

The observed condition is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The principal operational or security impact is: An aged MAC entry alone is not proof of failed transport or endpoint hardware. The supported repair is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

B:

These other facts could justify the alternative: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. They differ from the stated case: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Test the distinction using: Inspect forwarding database aging timers and the current learned location. The case-specific response is: An aged MAC entry alone is not proof of failed transport or endpoint hardware.

C:

The actual case evidence is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The proposed option addresses a different condition: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Confirm the distinction by checking: Inspect forwarding database aging timers and the current learned location. The response supported by the evidence is: An aged MAC entry alone is not proof of failed transport or endpoint hardware.

D:

The alternative is directed at this separate case: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The present incident is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The pertinent verification is: Inspect forwarding database aging timers and the current learned location. The action or outcome to select here is: An aged MAC entry alone is not proof of failed transport or endpoint hardware.

Question 669

A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The engineer wants a safe remedy. Which TWO actions should be paired? (Select TWO.)

  1. Recognize dynamic MAC aging and confirm attachment state before declaring service failure.
  2. Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
  3. Use nonintrusive test traffic and preserve logs for the original incident timeline.
  4. Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards.
  5. Correct the specific customer SAP port and encapsulation binding without modifying other tenants.

Explanation

Correct Answers

A:

This is the required technical repair: Recognize dynamic MAC aging and confirm attachment state before declaring service failure. The separately necessary deployment safeguard is: Use nonintrusive test traffic and preserve logs for the original incident timeline. Together they address: An aged MAC entry alone is not proof of failed transport or endpoint hardware.

C:

This safeguard prevents unwanted collateral effects: Use nonintrusive test traffic and preserve logs for the original incident timeline. Its complementary corrective change is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure. Both are required because: An aged MAC entry alone is not proof of failed transport or endpoint hardware.

Incorrect Answers

B:

The actual case evidence is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The proposed option addresses a different condition: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Confirm the distinction by checking: Inspect forwarding database aging timers and the current learned location. The response supported by the evidence is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure; and Use nonintrusive test traffic and preserve logs for the original incident timeline.

D:

This choice does not address the stated situation: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Its competing context is: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The relevant diagnostic is: Inspect forwarding database aging timers and the current learned location. The case-supported response is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure; and Use nonintrusive test traffic and preserve logs for the original incident timeline.

E:

The alternative applies to another situation: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The reported case instead states: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The distinguishing check is: Inspect forwarding database aging timers and the current learned location. The supported action or criterion is: Recognize dynamic MAC aging and confirm attachment state before declaring service failure; and Use nonintrusive test traffic and preserve logs for the original incident timeline.

Question 670

A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Which measurable result would verify success without relying on assumptions?

  1. The MAC resides at one intended site and VPLS unicast forwarding stabilizes.
  2. The expected MAC is relearned on the correct site while the service stays operational.
  3. The authorized Epipe becomes operational and remote customer MAC traffic is restored.
  4. Each service ID resolves to one authorized tenant and all attachments remain correctly mapped.

Explanation

Correct Answer

B:

The acceptance measurement for this case is: The expected MAC is relearned on the correct site while the service stays operational. It establishes that the intended remediation (“Recognize dynamic MAC aging and confirm attachment state before declaring service failure”) was effective and can be corroborated by: Generate one controlled frame from the authorized branch and observe new learning.

Incorrect Answers

A:

The actual case evidence is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The proposed option addresses a different condition: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. Confirm the distinction by checking: Inspect forwarding database aging timers and the current learned location. The response supported by the evidence is: The expected MAC is relearned on the correct site while the service stays operational.

C:

This choice does not address the stated situation: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Its competing context is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The relevant diagnostic is: Inspect forwarding database aging timers and the current learned location. The case-supported response is: The expected MAC is relearned on the correct site while the service stays operational.

D:

The alternative applies to another situation: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The reported case instead states: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The distinguishing check is: Inspect forwarding database aging timers and the current learned location. The supported action or criterion is: The expected MAC is relearned on the correct site while the service stays operational.

Nokia NRS II Composite: IS-IS version (4A0-C03) Practice Tests