Nokia 4A0-C03 Practice Test 69
Question 680
A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. After the approved repair, which outcome best demonstrates that this exact fault is resolved?
- Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
- All frames within the contracted size pass from source to remote customer handoff.
- Permitted large frames reach all sites and discard counters stop increasing.
- The contracted customer application passes while unapproved access remains blocked.
Explanation
Correct Answer
C:The acceptance measurement for this case is: Permitted large frames reach all sites and discard counters stop increasing. It establishes that the intended remediation (“Align approved customer payload limits with MPLS transport MTU and label-stack overhead”) was effective and can be corroborated by: Inspect size-related discards on service SDP and MPLS interfaces during synthetic tests.
Incorrect Answers
A:The actual case evidence is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The proposed option addresses a different condition: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Confirm the distinction by checking: Compare permitted customer frame size with every core link MTU and label count. The response supported by the evidence is: Permitted large frames reach all sites and discard counters stop increasing.
B:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The pertinent verification is: Compare permitted customer frame size with every core link MTU and label count. The action or outcome to select here is: Permitted large frames reach all sites and discard counters stop increasing.
D:The alternative applies to another situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The reported case instead states: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The distinguishing check is: Compare permitted customer frame size with every core link MTU and label count. The supported action or criterion is: Permitted large frames reach all sites and discard counters stop increasing.
Question 681
A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. An operator needs a controlled repair. Which response is most appropriate?
- Remove the unauthorized import membership and restore strict per-tenant VPN separation.
- Implement the approved layer-two spoke termination and layer-three service association.
- Reconcile unique internal service identifiers with current customer ownership and the intended SAPs.
- Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
Explanation
Correct Answer
D:The fault stated in this case is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The specific corrective action is: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries. Confirm it with: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The expected end-to-end outcome is: Frames from one customer remain isolated within its approved VPLS membership.
Incorrect Answers
A:The alternative is directed at this separate case: A copied RT import policy lets one enterprise's private subnet appear inside another tenant's VPRN route table during a provisioning rollout. The present incident is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The pertinent verification is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The action or outcome to select here is: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
B:This choice does not address the stated situation: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Its competing context is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The relevant diagnostic is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The case-supported response is: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
C:The alternative applies to another situation: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The reported case instead states: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The distinguishing check is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The supported action or criterion is: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
Question 682
A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Which TWO diagnostic investigations most directly test the cause? (Select TWO.)
- Inspect spoke SDP binding and the routed service interface on the destination PE.
- Inspect SAP-to-service mappings and the destination of synthetic broadcast frames.
- Compare both customer contracts with the active service and VLAN inventory.
- Inspect the unexpected VPN route's RT attributes and destination VPRN import policy.
- Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame.
Explanation
Correct Answers
B:This is a direct diagnostic for the reported fault: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. A second independent check is: Compare both customer contracts with the active service and VLAN inventory. Combined evidence distinguishes the fault before implementing: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
C:This is a direct diagnostic for the reported fault: Compare both customer contracts with the active service and VLAN inventory. A second independent check is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. Combined evidence distinguishes the fault before implementing: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
Incorrect Answers
A:This choice does not address the stated situation: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Its competing context is: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The relevant diagnostic is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The case-supported response is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames; and Compare both customer contracts with the active service and VLAN inventory.
D:The actual case evidence is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The proposed option addresses a different condition: A copied RT import policy lets one enterprise's private subnet appear inside another tenant's VPRN route table during a provisioning rollout. Confirm the distinction by checking: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The response supported by the evidence is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames; and Compare both customer contracts with the active service and VLAN inventory.
E:The alternative is directed at this separate case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The present incident is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The pertinent verification is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The action or outcome to select here is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames; and Compare both customer contracts with the active service and VLAN inventory.
Question 683
A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Which specific consequence explains why a repair is necessary?
- Incorrect SAP membership can create a serious cross-tenant layer-two data exposure.
- A correctly transported L2 circuit does not by itself create the intended routed VPN termination.
- Incorrect service identifiers can lead to wrong-customer configuration changes or audit errors.
- A route target error can violate VPN segmentation and potentially expose private traffic.
Explanation
Correct Answer
A:The observed condition is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The principal operational or security impact is: Incorrect SAP membership can create a serious cross-tenant layer-two data exposure. The supported repair is: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
B:These other facts could justify the alternative: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. They differ from the stated case: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Test the distinction using: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The case-specific response is: Incorrect SAP membership can create a serious cross-tenant layer-two data exposure.
C:The actual case evidence is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The proposed option addresses a different condition: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Confirm the distinction by checking: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The response supported by the evidence is: Incorrect SAP membership can create a serious cross-tenant layer-two data exposure.
D:The alternative is directed at this separate case: A copied RT import policy lets one enterprise's private subnet appear inside another tenant's VPRN route table during a provisioning rollout. The present incident is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The pertinent verification is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The action or outcome to select here is: Incorrect SAP membership can create a serious cross-tenant layer-two data exposure.
Question 684
A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Which TWO actions form both a suitable correction and its necessary change-control safeguard? (Select TWO.)
- Implement the approved layer-two spoke termination and layer-three service association.
- Disable only the offending attachment and audit nearby script-generated service entries.
- Preserve the intended mesh SDP split-horizon behavior and correct the invalid service topology.
- Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
- Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
Explanation
Correct Answers
B:This safeguard prevents unwanted collateral effects: Disable only the offending attachment and audit nearby script-generated service entries. Its complementary corrective change is: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries. Both are required because: Incorrect SAP membership can create a serious cross-tenant layer-two data exposure.
E:This is the required technical repair: Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries. The separately necessary deployment safeguard is: Disable only the offending attachment and audit nearby script-generated service entries. Together they address: Incorrect SAP membership can create a serious cross-tenant layer-two data exposure.
Incorrect Answers
A:These other facts could justify the alternative: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. They differ from the stated case: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Test the distinction using: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The case-specific response is: Disable only the offending attachment and audit nearby script-generated service entries; and Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
C:The alternative is directed at this separate case: A multipoint VPLS configuration attempts to relay a frame received from one mesh SDP toward another mesh SDP, generating duplicate copies in a provider-side ring. The present incident is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The pertinent verification is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The action or outcome to select here is: Disable only the offending attachment and audit nearby script-generated service entries; and Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
D:This choice does not address the stated situation: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Its competing context is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The relevant diagnostic is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The case-supported response is: Disable only the offending attachment and audit nearby script-generated service entries; and Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries.
Question 685
A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Which post-change observation is the strongest acceptance criterion?
- Each service ID resolves to one authorized tenant and all attachments remain correctly mapped.
- The spoke traffic terminates in the intended routed service and reaches authorized VPRN routes.
- Each tenant sees only its own authorized routes and cross-tenant forwarding is blocked.
- Frames from one customer remain isolated within its approved VPLS membership.
Explanation
Correct Answer
D:The acceptance measurement for this case is: Frames from one customer remain isolated within its approved VPLS membership. It establishes that the intended remediation (“Remove the unauthorized SAP membership and restore strict tenant-specific service attachment boundaries”) was effective and can be corroborated by: Compare both customer contracts with the active service and VLAN inventory.
Incorrect Answers
A:The actual case evidence is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The proposed option addresses a different condition: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. Confirm the distinction by checking: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The response supported by the evidence is: Frames from one customer remain isolated within its approved VPLS membership.
B:The alternative is directed at this separate case: A customer VPWS spoke is intended to terminate into a routed VPRN service, but the provider configures only a bridged handoff and traffic never enters the right IP routing context. The present incident is: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. The pertinent verification is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The action or outcome to select here is: Frames from one customer remain isolated within its approved VPLS membership.
C:This choice does not address the stated situation: A provisioning script copies a VPLS SAP into a separate customer's service instance, making test broadcasts appear at the wrong customer handoff. Its competing context is: A copied RT import policy lets one enterprise's private subnet appear inside another tenant's VPRN route table during a provisioning rollout. The relevant diagnostic is: Inspect SAP-to-service mappings and the destination of synthetic broadcast frames. The case-supported response is: Frames from one customer remain isolated within its approved VPLS membership.
Question 686
A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Which next technical step should the engineer prioritize?
- Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
- Troubleshoot the customer service attachment separately from the operational SDP transport test.
- Verify service identifier and SDP attachment consistency after confirming transport reachability.
- Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
Explanation
Correct Answer
B:The fault stated in this case is: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The specific corrective action is: Troubleshoot the customer service attachment separately from the operational SDP transport test. Confirm it with: Inspect the SAP's VLAN tag association and customer ingress discard counters. The expected end-to-end outcome is: Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
Incorrect Answers
A:The alternative is directed at this separate case: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The present incident is: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The pertinent verification is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The action or outcome to select here is: Troubleshoot the customer service attachment separately from the operational SDP transport test.
C:The alternative applies to another situation: An operations engineer uses service traceroute to reach the intended remote provider edge but the Epipe still reports an invalid remote service binding. The reported case instead states: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The distinguishing check is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The supported action or criterion is: Troubleshoot the customer service attachment separately from the operational SDP transport test.
D:These other facts could justify the alternative: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. They differ from the stated case: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Test the distinction using: Inspect the SAP's VLAN tag association and customer ingress discard counters. The case-specific response is: Troubleshoot the customer service attachment separately from the operational SDP transport test.
Question 687
A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Which TWO items of evidence should the engineer examine first? (Select TWO.)
- Compare successful service OAM results with a controlled end-to-end customer frame test.
- Inspect the service traceroute endpoint and service binding configuration at both PEs.
- Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
- Compare permitted customer frame size with every core link MTU and label count.
- Inspect the SAP's VLAN tag association and customer ingress discard counters.
Explanation
Correct Answers
A:This is a direct diagnostic for the reported fault: Compare successful service OAM results with a controlled end-to-end customer frame test. A second independent check is: Inspect the SAP's VLAN tag association and customer ingress discard counters. Combined evidence distinguishes the fault before implementing: Troubleshoot the customer service attachment separately from the operational SDP transport test.
E:This is a direct diagnostic for the reported fault: Inspect the SAP's VLAN tag association and customer ingress discard counters. A second independent check is: Compare successful service OAM results with a controlled end-to-end customer frame test. Combined evidence distinguishes the fault before implementing: Troubleshoot the customer service attachment separately from the operational SDP transport test.
Incorrect Answers
B:The alternative applies to another situation: An operations engineer uses service traceroute to reach the intended remote provider edge but the Epipe still reports an invalid remote service binding. The reported case instead states: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The distinguishing check is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The supported action or criterion is: Compare successful service OAM results with a controlled end-to-end customer frame test; and Inspect the SAP's VLAN tag association and customer ingress discard counters.
C:These other facts could justify the alternative: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. They differ from the stated case: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Test the distinction using: Inspect the SAP's VLAN tag association and customer ingress discard counters. The case-specific response is: Compare successful service OAM results with a controlled end-to-end customer frame test; and Inspect the SAP's VLAN tag association and customer ingress discard counters.
D:The actual case evidence is: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The proposed option addresses a different condition: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Confirm the distinction by checking: Inspect the SAP's VLAN tag association and customer ingress discard counters. The response supported by the evidence is: Compare successful service OAM results with a controlled end-to-end customer frame test; and Inspect the SAP's VLAN tag association and customer ingress discard counters.
Question 688
A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. If the condition is left unresolved, which operational consequence is most directly at risk?
- A green transport or SDP check cannot establish application reachability through customer filters.
- Service control sessions can remain healthy while oversized customer frames are silently dropped.
- Transport OAM success does not guarantee correct attachment or customer encapsulation.
- A transport path can exist while service-level forwarding remains unbound.
Explanation
Correct Answer
C:The observed condition is: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The principal operational or security impact is: Transport OAM success does not guarantee correct attachment or customer encapsulation. The supported repair is: Troubleshoot the customer service attachment separately from the operational SDP transport test. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The reported case instead states: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The distinguishing check is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The supported action or criterion is: Transport OAM success does not guarantee correct attachment or customer encapsulation.
B:These other facts could justify the alternative: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. They differ from the stated case: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Test the distinction using: Inspect the SAP's VLAN tag association and customer ingress discard counters. The case-specific response is: Transport OAM success does not guarantee correct attachment or customer encapsulation.
D:The alternative is directed at this separate case: An operations engineer uses service traceroute to reach the intended remote provider edge but the Epipe still reports an invalid remote service binding. The present incident is: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The pertinent verification is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The action or outcome to select here is: Transport OAM success does not guarantee correct attachment or customer encapsulation.
Question 689
A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The engineer wants a safe remedy. Which TWO actions should be paired? (Select TWO.)
- Verify MTU at both customer attachment endpoints and the transport service overhead.
- Verify service identifier and SDP attachment consistency after confirming transport reachability.
- Troubleshoot the customer service attachment separately from the operational SDP transport test.
- Attach the approved IES interface to the proper global routed service context.
- Use a synthetic VLAN test and preserve current healthy transport configuration.
Explanation
Correct Answers
C:This is the required technical repair: Troubleshoot the customer service attachment separately from the operational SDP transport test. The separately necessary deployment safeguard is: Use a synthetic VLAN test and preserve current healthy transport configuration. Together they address: Transport OAM success does not guarantee correct attachment or customer encapsulation.
E:This safeguard prevents unwanted collateral effects: Use a synthetic VLAN test and preserve current healthy transport configuration. Its complementary corrective change is: Troubleshoot the customer service attachment separately from the operational SDP transport test. Both are required because: Transport OAM success does not guarantee correct attachment or customer encapsulation.
Incorrect Answers
A:These other facts could justify the alternative: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. They differ from the stated case: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Test the distinction using: Inspect the SAP's VLAN tag association and customer ingress discard counters. The case-specific response is: Troubleshoot the customer service attachment separately from the operational SDP transport test; and Use a synthetic VLAN test and preserve current healthy transport configuration.
B:The actual case evidence is: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The proposed option addresses a different condition: An operations engineer uses service traceroute to reach the intended remote provider edge but the Epipe still reports an invalid remote service binding. Confirm the distinction by checking: Inspect the SAP's VLAN tag association and customer ingress discard counters. The response supported by the evidence is: Troubleshoot the customer service attachment separately from the operational SDP transport test; and Use a synthetic VLAN test and preserve current healthy transport configuration.
D:This choice does not address the stated situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Its competing context is: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. The relevant diagnostic is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The case-supported response is: Troubleshoot the customer service attachment separately from the operational SDP transport test; and Use a synthetic VLAN test and preserve current healthy transport configuration.
Question 690
A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Which measurable result would verify success without relying on assumptions?
- Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
- Permitted large frames reach all sites and discard counters stop increasing.
- The remote PE and specific Epipe service both resolve and customer traffic passes.
- The contracted customer application passes while unapproved access remains blocked.
Explanation
Correct Answer
A:The acceptance measurement for this case is: Both the SDP OAM and end-to-end authorized customer frame forwarding succeed. It establishes that the intended remediation (“Troubleshoot the customer service attachment separately from the operational SDP transport test”) was effective and can be corroborated by: Compare successful service OAM results with a controlled end-to-end customer frame test.
Incorrect Answers
B:The alternative is directed at this separate case: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The present incident is: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The pertinent verification is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The action or outcome to select here is: Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
C:This choice does not address the stated situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Its competing context is: An operations engineer uses service traceroute to reach the intended remote provider edge but the Epipe still reports an invalid remote service binding. The relevant diagnostic is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The case-supported response is: Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
D:The alternative applies to another situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The reported case instead states: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The distinguishing check is: Inspect the SAP's VLAN tag association and customer ingress discard counters. The supported action or criterion is: Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.