Nokia 4A0-C03 Practice Test 68
Question 670
A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Which measurable result would verify success without relying on assumptions?
- The MAC resides at one intended site and VPLS unicast forwarding stabilizes.
- The expected MAC is relearned on the correct site while the service stays operational.
- The authorized Epipe becomes operational and remote customer MAC traffic is restored.
- Each service ID resolves to one authorized tenant and all attachments remain correctly mapped.
Explanation
Correct Answer
B:The acceptance measurement for this case is: The expected MAC is relearned on the correct site while the service stays operational. It establishes that the intended remediation (“Recognize dynamic MAC aging and confirm attachment state before declaring service failure”) was effective and can be corroborated by: Generate one controlled frame from the authorized branch and observe new learning.
Incorrect Answers
A:The actual case evidence is: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The proposed option addresses a different condition: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. Confirm the distinction by checking: Inspect forwarding database aging timers and the current learned location. The response supported by the evidence is: The expected MAC is relearned on the correct site while the service stays operational.
C:This choice does not address the stated situation: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. Its competing context is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The relevant diagnostic is: Inspect forwarding database aging timers and the current learned location. The case-supported response is: The expected MAC is relearned on the correct site while the service stays operational.
D:The alternative applies to another situation: An automation job uses a retired VPLS service ID for a new customer's branch, causing ambiguous service references in an operations dashboard. The reported case instead states: A branch endpoint is idle long enough for its VPLS MAC entry to age out, and support concludes the physical site has failed despite an Up SDP. The distinguishing check is: Inspect forwarding database aging timers and the current learned location. The supported action or criterion is: The expected MAC is relearned on the correct site while the service stays operational.
Question 671
Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. Which change most directly addresses the observed problem?
- Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards.
- Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.
- Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub.
- Verify MTU at both customer attachment endpoints and the transport service overhead.
Explanation
Correct Answer
C:The fault stated in this case is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The specific corrective action is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub. Confirm it with: Inspect spoke SDP topology and the effective service forwarding graph. The expected end-to-end outcome is: Observed spoke traffic follows the authorized hub path and meets documented latency expectations.
Incorrect Answers
A:The alternative is directed at this separate case: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The present incident is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The pertinent verification is: Inspect spoke SDP topology and the effective service forwarding graph. The action or outcome to select here is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub.
B:This choice does not address the stated situation: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. Its competing context is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The relevant diagnostic is: Inspect spoke SDP topology and the effective service forwarding graph. The case-supported response is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub.
D:These other facts could justify the alternative: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. They differ from the stated case: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. Test the distinction using: Inspect spoke SDP topology and the effective service forwarding graph. The case-specific response is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub.
Question 672
Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. Which TWO independent checks would best establish what is happening? (Select TWO.)
- Inspect spoke SDP topology and the effective service forwarding graph.
- Inspect remote service endpoint type and split-horizon group membership.
- Measure synthetic frame path through remote spokes and the central hub.
- Inspect service ID, far-end and signaling state at both Epipe endpoints.
- Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
Explanation
Correct Answers
A:This is a direct diagnostic for the reported fault: Inspect spoke SDP topology and the effective service forwarding graph. A second independent check is: Measure synthetic frame path through remote spokes and the central hub. Combined evidence distinguishes the fault before implementing: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub.
C:This is a direct diagnostic for the reported fault: Measure synthetic frame path through remote spokes and the central hub. A second independent check is: Inspect spoke SDP topology and the effective service forwarding graph. Combined evidence distinguishes the fault before implementing: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub.
Incorrect Answers
B:The alternative applies to another situation: A hub-and-spoke VPLS needs a traffic flow from one remote spoke to another through the hub, but both service endpoints are incorrectly classified as mesh SDPs. The reported case instead states: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The distinguishing check is: Inspect spoke SDP topology and the effective service forwarding graph. The supported action or criterion is: Inspect spoke SDP topology and the effective service forwarding graph; and Measure synthetic frame path through remote spokes and the central hub.
D:The actual case evidence is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The proposed option addresses a different condition: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Confirm the distinction by checking: Inspect spoke SDP topology and the effective service forwarding graph. The response supported by the evidence is: Inspect spoke SDP topology and the effective service forwarding graph; and Measure synthetic frame path through remote spokes and the central hub.
E:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The pertinent verification is: Inspect spoke SDP topology and the effective service forwarding graph. The action or outcome to select here is: Inspect spoke SDP topology and the effective service forwarding graph; and Measure synthetic frame path through remote spokes and the central hub.
Question 673
Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. What is the key technical or security failure this situation can produce?
- Assuming direct spoke reachability can conceal deliberate split-horizon or hub policy behavior.
- Duplicate MAC identities can cause intermittent private-layer-two forwarding and service instability.
- A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.
- Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.
Explanation
Correct Answer
A:The observed condition is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The principal operational or security impact is: Assuming direct spoke reachability can conceal deliberate split-horizon or hub policy behavior. The supported repair is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
B:These other facts could justify the alternative: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. They differ from the stated case: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. Test the distinction using: Inspect spoke SDP topology and the effective service forwarding graph. The case-specific response is: Assuming direct spoke reachability can conceal deliberate split-horizon or hub policy behavior.
C:The actual case evidence is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The proposed option addresses a different condition: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Confirm the distinction by checking: Inspect spoke SDP topology and the effective service forwarding graph. The response supported by the evidence is: Assuming direct spoke reachability can conceal deliberate split-horizon or hub policy behavior.
D:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The pertinent verification is: Inspect spoke SDP topology and the effective service forwarding graph. The action or outcome to select here is: Assuming direct spoke reachability can conceal deliberate split-horizon or hub policy behavior.
Question 674
Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. Choose TWO complementary steps: one repair and one precaution against collateral impact. (Select TWO.)
- Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub.
- Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.
- Use a test VLAN to compare designs without creating new provider-side loops.
- Use the supported spoke and hub service design to permit required transit without breaking loop prevention.
- Repair the specific remote SDP flood-list membership for the contracted VPLS topology.
Explanation
Correct Answers
A:This is the required technical repair: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub. The separately necessary deployment safeguard is: Use a test VLAN to compare designs without creating new provider-side loops. Together they address: Assuming direct spoke reachability can conceal deliberate split-horizon or hub policy behavior.
C:This safeguard prevents unwanted collateral effects: Use a test VLAN to compare designs without creating new provider-side loops. Its complementary corrective change is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub. Both are required because: Assuming direct spoke reachability can conceal deliberate split-horizon or hub policy behavior.
Incorrect Answers
B:The actual case evidence is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The proposed option addresses a different condition: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Confirm the distinction by checking: Inspect spoke SDP topology and the effective service forwarding graph. The response supported by the evidence is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub; and Use a test VLAN to compare designs without creating new provider-side loops.
D:This choice does not address the stated situation: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. Its competing context is: A hub-and-spoke VPLS needs a traffic flow from one remote spoke to another through the hub, but both service endpoints are incorrectly classified as mesh SDPs. The relevant diagnostic is: Inspect spoke SDP topology and the effective service forwarding graph. The case-supported response is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub; and Use a test VLAN to compare designs without creating new provider-side loops.
E:The alternative applies to another situation: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. The reported case instead states: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The distinguishing check is: Inspect spoke SDP topology and the effective service forwarding graph. The supported action or criterion is: Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub; and Use a test VLAN to compare designs without creating new provider-side loops.
Question 675
Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. What evidence would demonstrate that the intended fix worked correctly?
- Observed spoke traffic follows the authorized hub path and meets documented latency expectations.
- All frames within the contracted size pass from source to remote customer handoff.
- The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire.
- The MAC resides at one intended site and VPLS unicast forwarding stabilizes.
Explanation
Correct Answer
A:The acceptance measurement for this case is: Observed spoke traffic follows the authorized hub path and meets documented latency expectations. It establishes that the intended remediation (“Validate the supported hub-and-spoke VPLS forwarding design and document intended transit through the hub”) was effective and can be corroborated by: Measure synthetic frame path through remote spokes and the central hub.
Incorrect Answers
B:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The pertinent verification is: Inspect spoke SDP topology and the effective service forwarding graph. The action or outcome to select here is: Observed spoke traffic follows the authorized hub path and meets documented latency expectations.
C:This choice does not address the stated situation: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. Its competing context is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The relevant diagnostic is: Inspect spoke SDP topology and the effective service forwarding graph. The case-supported response is: Observed spoke traffic follows the authorized hub path and meets documented latency expectations.
D:The alternative applies to another situation: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The reported case instead states: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The distinguishing check is: Inspect spoke SDP topology and the effective service forwarding graph. The supported action or criterion is: Observed spoke traffic follows the authorized hub path and meets documented latency expectations.
Question 676
A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Which corrective action best resolves this particular network fault?
- Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
- Verify MTU at both customer attachment endpoints and the transport service overhead.
- Troubleshoot the customer service attachment separately from the operational SDP transport test.
- Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
Explanation
Correct Answer
A:The fault stated in this case is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The specific corrective action is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead. Confirm it with: Compare permitted customer frame size with every core link MTU and label count. The expected end-to-end outcome is: Permitted large frames reach all sites and discard counters stop increasing.
Incorrect Answers
B:This choice does not address the stated situation: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Its competing context is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The relevant diagnostic is: Compare permitted customer frame size with every core link MTU and label count. The case-supported response is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
C:The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The distinguishing check is: Compare permitted customer frame size with every core link MTU and label count. The supported action or criterion is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
D:These other facts could justify the alternative: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. They differ from the stated case: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Test the distinction using: Compare permitted customer frame size with every core link MTU and label count. The case-specific response is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
Question 677
A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Before proposing a change, which TWO observations would give the most useful confirmation? (Select TWO.)
- Inspect service-SDP operational state and its selected underlying transport LSP.
- Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
- Inspect service OAM result and remote SAP policy drop counters together.
- Compare permitted customer frame size with every core link MTU and label count.
- Inspect size-related discards on service SDP and MPLS interfaces during synthetic tests.
Explanation
Correct Answers
D:This is a direct diagnostic for the reported fault: Compare permitted customer frame size with every core link MTU and label count. A second independent check is: Inspect size-related discards on service SDP and MPLS interfaces during synthetic tests. Combined evidence distinguishes the fault before implementing: Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
E:This is a direct diagnostic for the reported fault: Inspect size-related discards on service SDP and MPLS interfaces during synthetic tests. A second independent check is: Compare permitted customer frame size with every core link MTU and label count. Combined evidence distinguishes the fault before implementing: Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
Incorrect Answers
A:This choice does not address the stated situation: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Its competing context is: A customer service is bound to an SDP but its underlying LSP is down, and a technician wants to recreate every VPLS SAP rather than checking the transport dependency. The relevant diagnostic is: Compare permitted customer frame size with every core link MTU and label count. The case-supported response is: Compare permitted customer frame size with every core link MTU and label count; and Inspect size-related discards on service SDP and MPLS interfaces during synthetic tests.
B:The alternative applies to another situation: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The reported case instead states: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The distinguishing check is: Compare permitted customer frame size with every core link MTU and label count. The supported action or criterion is: Compare permitted customer frame size with every core link MTU and label count; and Inspect size-related discards on service SDP and MPLS interfaces during synthetic tests.
C:These other facts could justify the alternative: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. They differ from the stated case: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Test the distinction using: Compare permitted customer frame size with every core link MTU and label count. The case-specific response is: Compare permitted customer frame size with every core link MTU and label count; and Inspect size-related discards on service SDP and MPLS interfaces during synthetic tests.
Question 678
A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Which statement best describes the immediate risk of ignoring this problem?
- Transport OAM success does not guarantee correct attachment or customer encapsulation.
- Service control sessions can remain healthy while oversized customer frames are silently dropped.
- A green transport or SDP check cannot establish application reachability through customer filters.
- Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.
Explanation
Correct Answer
B:The observed condition is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The principal operational or security impact is: Service control sessions can remain healthy while oversized customer frames are silently dropped. The supported repair is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The distinguishing check is: Compare permitted customer frame size with every core link MTU and label count. The supported action or criterion is: Service control sessions can remain healthy while oversized customer frames are silently dropped.
C:The actual case evidence is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Compare permitted customer frame size with every core link MTU and label count. The response supported by the evidence is: Service control sessions can remain healthy while oversized customer frames are silently dropped.
D:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The pertinent verification is: Compare permitted customer frame size with every core link MTU and label count. The action or outcome to select here is: Service control sessions can remain healthy while oversized customer frames are silently dropped.
Question 679
A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. Which TWO measures together address the fault while protecting other services? (Select TWO.)
- Align approved customer payload limits with MPLS transport MTU and label-stack overhead.
- Verify MTU at both customer attachment endpoints and the transport service overhead.
- Resolve the duplicate customer MAC assignment and preserve normal VPLS learning safeguards.
- Validate an approved common MTU in a lab before modifying shared core ports.
- Separate the service-level SDP association from the core MPLS transport tunnel and restore the missing dependency.
Explanation
Correct Answers
A:This is the required technical repair: Align approved customer payload limits with MPLS transport MTU and label-stack overhead. The separately necessary deployment safeguard is: Validate an approved common MTU in a lab before modifying shared core ports. Together they address: Service control sessions can remain healthy while oversized customer frames are silently dropped.
D:This safeguard prevents unwanted collateral effects: Validate an approved common MTU in a lab before modifying shared core ports. Its complementary corrective change is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead. Both are required because: Service control sessions can remain healthy while oversized customer frames are silently dropped.
Incorrect Answers
B:The actual case evidence is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The proposed option addresses a different condition: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Confirm the distinction by checking: Compare permitted customer frame size with every core link MTU and label count. The response supported by the evidence is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead; and Validate an approved common MTU in a lab before modifying shared core ports.
C:The alternative is directed at this separate case: A customer accidentally configures the same Ethernet MAC on cloned appliances in different branches of one VPLS, causing rapid MAC move events. The present incident is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The pertinent verification is: Compare permitted customer frame size with every core link MTU and label count. The action or outcome to select here is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead; and Validate an approved common MTU in a lab before modifying shared core ports.
E:The alternative applies to another situation: A customer service is bound to an SDP but its underlying LSP is down, and a technician wants to recreate every VPLS SAP rather than checking the transport dependency. The reported case instead states: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The distinguishing check is: Compare permitted customer frame size with every core link MTU and label count. The supported action or criterion is: Align approved customer payload limits with MPLS transport MTU and label-stack overhead; and Validate an approved common MTU in a lab before modifying shared core ports.
Question 680
A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. After the approved repair, which outcome best demonstrates that this exact fault is resolved?
- Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
- All frames within the contracted size pass from source to remote customer handoff.
- Permitted large frames reach all sites and discard counters stop increasing.
- The contracted customer application passes while unapproved access remains blocked.
Explanation
Correct Answer
C:The acceptance measurement for this case is: Permitted large frames reach all sites and discard counters stop increasing. It establishes that the intended remediation (“Align approved customer payload limits with MPLS transport MTU and label-stack overhead”) was effective and can be corroborated by: Inspect size-related discards on service SDP and MPLS interfaces during synthetic tests.
Incorrect Answers
A:The actual case evidence is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The proposed option addresses a different condition: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. Confirm the distinction by checking: Compare permitted customer frame size with every core link MTU and label count. The response supported by the evidence is: Permitted large frames reach all sites and discard counters stop increasing.
B:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The pertinent verification is: Compare permitted customer frame size with every core link MTU and label count. The action or outcome to select here is: Permitted large frames reach all sites and discard counters stop increasing.
D:The alternative applies to another situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The reported case instead states: A multipoint Ethernet customer can send small frames but full-size frames fail because an additional provider label increases transport overhead beyond the core path MTU. The distinguishing check is: Compare permitted customer frame size with every core link MTU and label count. The supported action or criterion is: Permitted large frames reach all sites and discard counters stop increasing.