Nokia 4A0-C03 Practice Test 65
Question 640
A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. After the approved repair, which outcome best demonstrates that this exact fault is resolved?
- The contracted customer application passes while unapproved access remains blocked.
- Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
- The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.
- Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.
Explanation
Correct Answer
C:The acceptance measurement for this case is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly. It establishes that the intended remediation (“Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff”) was effective and can be corroborated by: Inspect egress SAP encapsulation and any configured VLAN rewrite behavior.
Incorrect Answers
A:The actual case evidence is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Capture synthetic frames at both access ports and compare VLAN tag presence. The response supported by the evidence is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.
B:The alternative is directed at this separate case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The present incident is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The pertinent verification is: Capture synthetic frames at both access ports and compare VLAN tag presence. The action or outcome to select here is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.
D:The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The distinguishing check is: Capture synthetic frames at both access ports and compare VLAN tag presence. The supported action or criterion is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.
Question 641
A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. An operator needs a controlled repair. Which response is most appropriate?
- Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
- Diagnose the remote attachment status rather than changing the already healthy transport LSP.
- Restore the intended service administrative state after confirming maintenance authorization.
- Monitor the individual customer SAP operational state as well as transport and service status.
Explanation
Correct Answer
C:The fault stated in this case is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The specific corrective action is: Restore the intended service administrative state after confirming maintenance authorization. Confirm it with: Inspect the Epipe admin and oper status alongside physical port state. The expected end-to-end outcome is: The authorized Epipe becomes operational and remote customer MAC traffic is restored.
Incorrect Answers
A:The alternative is directed at this separate case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The present incident is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The pertinent verification is: Inspect the Epipe admin and oper status alongside physical port state. The action or outcome to select here is: Restore the intended service administrative state after confirming maintenance authorization.
B:This choice does not address the stated situation: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Inspect the Epipe admin and oper status alongside physical port state. The case-supported response is: Restore the intended service administrative state after confirming maintenance authorization.
D:These other facts could justify the alternative: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. They differ from the stated case: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Test the distinction using: Inspect the Epipe admin and oper status alongside physical port state. The case-specific response is: Restore the intended service administrative state after confirming maintenance authorization.
Question 642
A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Which TWO diagnostic investigations most directly test the cause? (Select TWO.)
- Inspect pseudowire status TLVs and remote attachment-circuit alarms.
- Compare change history with service-level alarms for that customer identifier.
- Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame.
- Inspect the Epipe admin and oper status alongside physical port state.
- Inspect actual SR OS port mode and the service attachment hierarchy.
Explanation
Correct Answers
B:This is a direct diagnostic for the reported fault: Compare change history with service-level alarms for that customer identifier. A second independent check is: Inspect the Epipe admin and oper status alongside physical port state. Combined evidence distinguishes the fault before implementing: Restore the intended service administrative state after confirming maintenance authorization.
D:This is a direct diagnostic for the reported fault: Inspect the Epipe admin and oper status alongside physical port state. A second independent check is: Compare change history with service-level alarms for that customer identifier. Combined evidence distinguishes the fault before implementing: Restore the intended service administrative state after confirming maintenance authorization.
Incorrect Answers
A:This choice does not address the stated situation: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Inspect the Epipe admin and oper status alongside physical port state. The case-supported response is: Compare change history with service-level alarms for that customer identifier; and Inspect the Epipe admin and oper status alongside physical port state.
C:These other facts could justify the alternative: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. They differ from the stated case: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Test the distinction using: Inspect the Epipe admin and oper status alongside physical port state. The case-specific response is: Compare change history with service-level alarms for that customer identifier; and Inspect the Epipe admin and oper status alongside physical port state.
E:The alternative is directed at this separate case: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The present incident is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The pertinent verification is: Inspect the Epipe admin and oper status alongside physical port state. The action or outcome to select here is: Compare change history with service-level alarms for that customer identifier; and Inspect the Epipe admin and oper status alongside physical port state.
Question 643
A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Which specific consequence explains why a repair is necessary?
- A healthy interface cannot carry private-wire traffic through a disabled service instance.
- A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
- Aggregated service status can conceal a failed required attachment circuit.
- A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
Explanation
Correct Answer
A:The observed condition is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The principal operational or security impact is: A healthy interface cannot carry private-wire traffic through a disabled service instance. The supported repair is: Restore the intended service administrative state after confirming maintenance authorization. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
B:These other facts could justify the alternative: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. They differ from the stated case: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Test the distinction using: Inspect the Epipe admin and oper status alongside physical port state. The case-specific response is: A healthy interface cannot carry private-wire traffic through a disabled service instance.
C:The actual case evidence is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The proposed option addresses a different condition: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. Confirm the distinction by checking: Inspect the Epipe admin and oper status alongside physical port state. The response supported by the evidence is: A healthy interface cannot carry private-wire traffic through a disabled service instance.
D:The alternative is directed at this separate case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The present incident is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The pertinent verification is: Inspect the Epipe admin and oper status alongside physical port state. The action or outcome to select here is: A healthy interface cannot carry private-wire traffic through a disabled service instance.
Question 644
A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Which TWO actions form both a suitable correction and its necessary change-control safeguard? (Select TWO.)
- Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
- Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
- Restore the intended service administrative state after confirming maintenance authorization.
- Verify the service owner and other active service dependencies before enabling.
- Distinguish access ports and their SAPs from the provider's network-facing transport ports.
Explanation
Correct Answers
C:This is the required technical repair: Restore the intended service administrative state after confirming maintenance authorization. The separately necessary deployment safeguard is: Verify the service owner and other active service dependencies before enabling. Together they address: A healthy interface cannot carry private-wire traffic through a disabled service instance.
D:This safeguard prevents unwanted collateral effects: Verify the service owner and other active service dependencies before enabling. Its complementary corrective change is: Restore the intended service administrative state after confirming maintenance authorization. Both are required because: A healthy interface cannot carry private-wire traffic through a disabled service instance.
Incorrect Answers
A:These other facts could justify the alternative: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. They differ from the stated case: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Test the distinction using: Inspect the Epipe admin and oper status alongside physical port state. The case-specific response is: Restore the intended service administrative state after confirming maintenance authorization; and Verify the service owner and other active service dependencies before enabling.
B:The actual case evidence is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Inspect the Epipe admin and oper status alongside physical port state. The response supported by the evidence is: Restore the intended service administrative state after confirming maintenance authorization; and Verify the service owner and other active service dependencies before enabling.
E:The alternative applies to another situation: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. The reported case instead states: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The distinguishing check is: Inspect the Epipe admin and oper status alongside physical port state. The supported action or criterion is: Restore the intended service administrative state after confirming maintenance authorization; and Verify the service owner and other active service dependencies before enabling.
Question 645
A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Which post-change observation is the strongest acceptance criterion?
- The authorized Epipe becomes operational and remote customer MAC traffic is restored.
- The remote attachment comes Up and the Epipe reports end-to-end operational service.
- Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
- Monitoring flags the correct customer attachment outage even when the core transport remains active.
Explanation
Correct Answer
A:The acceptance measurement for this case is: The authorized Epipe becomes operational and remote customer MAC traffic is restored. It establishes that the intended remediation (“Restore the intended service administrative state after confirming maintenance authorization”) was effective and can be corroborated by: Compare change history with service-level alarms for that customer identifier.
Incorrect Answers
B:The alternative is directed at this separate case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The present incident is: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The pertinent verification is: Inspect the Epipe admin and oper status alongside physical port state. The action or outcome to select here is: The authorized Epipe becomes operational and remote customer MAC traffic is restored.
C:This choice does not address the stated situation: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. Its competing context is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The relevant diagnostic is: Inspect the Epipe admin and oper status alongside physical port state. The case-supported response is: The authorized Epipe becomes operational and remote customer MAC traffic is restored.
D:The alternative applies to another situation: A maintenance team closes an Epipe SAP administratively but the global service and core SDP remain Up, misleading customer monitoring that checks only the SDP. The reported case instead states: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The distinguishing check is: Inspect the Epipe admin and oper status alongside physical port state. The supported action or criterion is: The authorized Epipe becomes operational and remote customer MAC traffic is restored.
Question 646
A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Which next technical step should the engineer prioritize?
- Diagnose the remote attachment status rather than changing the already healthy transport LSP.
- Verify MTU at both customer attachment endpoints and the transport service overhead.
- Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
- Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.
Explanation
Correct Answer
A:The fault stated in this case is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The specific corrective action is: Diagnose the remote attachment status rather than changing the already healthy transport LSP. Confirm it with: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The expected end-to-end outcome is: The remote attachment comes Up and the Epipe reports end-to-end operational service.
Incorrect Answers
B:This choice does not address the stated situation: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Its competing context is: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The relevant diagnostic is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The case-supported response is: Diagnose the remote attachment status rather than changing the already healthy transport LSP.
C:The alternative applies to another situation: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The reported case instead states: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The distinguishing check is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The supported action or criterion is: Diagnose the remote attachment status rather than changing the already healthy transport LSP.
D:These other facts could justify the alternative: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. They differ from the stated case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Test the distinction using: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The case-specific response is: Diagnose the remote attachment status rather than changing the already healthy transport LSP.
Question 647
A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Which TWO items of evidence should the engineer examine first? (Select TWO.)
- Inspect service ID, far-end and signaling state at both Epipe endpoints.
- Inspect the Epipe admin and oper status alongside physical port state.
- Compare local SDP transport state with the remote SAP's physical and admin state.
- Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
- Inspect pseudowire status TLVs and remote attachment-circuit alarms.
Explanation
Correct Answers
C:This is a direct diagnostic for the reported fault: Compare local SDP transport state with the remote SAP's physical and admin state. A second independent check is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. Combined evidence distinguishes the fault before implementing: Diagnose the remote attachment status rather than changing the already healthy transport LSP.
E:This is a direct diagnostic for the reported fault: Inspect pseudowire status TLVs and remote attachment-circuit alarms. A second independent check is: Compare local SDP transport state with the remote SAP's physical and admin state. Combined evidence distinguishes the fault before implementing: Diagnose the remote attachment status rather than changing the already healthy transport LSP.
Incorrect Answers
A:This choice does not address the stated situation: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Its competing context is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The relevant diagnostic is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The case-supported response is: Compare local SDP transport state with the remote SAP's physical and admin state; and Inspect pseudowire status TLVs and remote attachment-circuit alarms.
B:The alternative applies to another situation: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. The reported case instead states: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The distinguishing check is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The supported action or criterion is: Compare local SDP transport state with the remote SAP's physical and admin state; and Inspect pseudowire status TLVs and remote attachment-circuit alarms.
D:The actual case evidence is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The proposed option addresses a different condition: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Confirm the distinction by checking: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The response supported by the evidence is: Compare local SDP transport state with the remote SAP's physical and admin state; and Inspect pseudowire status TLVs and remote attachment-circuit alarms.
Question 648
A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. If the condition is left unresolved, which operational consequence is most directly at risk?
- A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.
- Sufficient core transport MTU alone does not guarantee the remote customer handoff supports the frame size.
- A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
- A green transport or SDP check cannot establish application reachability through customer filters.
Explanation
Correct Answer
C:The observed condition is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The principal operational or security impact is: A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down. The supported repair is: Diagnose the remote attachment status rather than changing the already healthy transport LSP. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The reported case instead states: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The distinguishing check is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The supported action or criterion is: A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
B:These other facts could justify the alternative: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. They differ from the stated case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Test the distinction using: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The case-specific response is: A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
D:The alternative is directed at this separate case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The present incident is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The pertinent verification is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The action or outcome to select here is: A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
Question 649
A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The engineer wants a safe remedy. Which TWO actions should be paired? (Select TWO.)
- Restore the intended service administrative state after confirming maintenance authorization.
- Distinguish access ports and their SAPs from the provider's network-facing transport ports.
- Coordinate access-port repair with the remote team and preserve service labels.
- Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.
- Diagnose the remote attachment status rather than changing the already healthy transport LSP.
Explanation
Correct Answers
C:This safeguard prevents unwanted collateral effects: Coordinate access-port repair with the remote team and preserve service labels. Its complementary corrective change is: Diagnose the remote attachment status rather than changing the already healthy transport LSP. Both are required because: A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
E:This is the required technical repair: Diagnose the remote attachment status rather than changing the already healthy transport LSP. The separately necessary deployment safeguard is: Coordinate access-port repair with the remote team and preserve service labels. Together they address: A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
Incorrect Answers
A:These other facts could justify the alternative: A customer reports an Ethernet circuit outage even though both physical interfaces are Up because the Epipe service was administratively disabled after maintenance. They differ from the stated case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Test the distinction using: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The case-specific response is: Coordinate access-port repair with the remote team and preserve service labels; and Diagnose the remote attachment status rather than changing the already healthy transport LSP.
B:The actual case evidence is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The proposed option addresses a different condition: An operator configures a customer access SAP on a port reserved as an MPLS network-facing uplink and assumes that all Ethernet interfaces can be treated interchangeably. Confirm the distinction by checking: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The response supported by the evidence is: Coordinate access-port repair with the remote team and preserve service labels; and Diagnose the remote attachment status rather than changing the already healthy transport LSP.
D:This choice does not address the stated situation: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Its competing context is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The relevant diagnostic is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The case-supported response is: Coordinate access-port repair with the remote team and preserve service labels; and Diagnose the remote attachment status rather than changing the already healthy transport LSP.
Question 650
A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Which measurable result would verify success without relying on assumptions?
- The contracted customer application passes while unapproved access remains blocked.
- All frames within the contracted size pass from source to remote customer handoff.
- The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire.
- The remote attachment comes Up and the Epipe reports end-to-end operational service.
Explanation
Correct Answer
D:The acceptance measurement for this case is: The remote attachment comes Up and the Epipe reports end-to-end operational service. It establishes that the intended remediation (“Diagnose the remote attachment status rather than changing the already healthy transport LSP”) was effective and can be corroborated by: Compare local SDP transport state with the remote SAP's physical and admin state.
Incorrect Answers
A:The actual case evidence is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The response supported by the evidence is: The remote attachment comes Up and the Epipe reports end-to-end operational service.
B:The alternative is directed at this separate case: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. The present incident is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The pertinent verification is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The action or outcome to select here is: The remote attachment comes Up and the Epipe reports end-to-end operational service.
C:This choice does not address the stated situation: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. Its competing context is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The relevant diagnostic is: Inspect pseudowire status TLVs and remote attachment-circuit alarms. The case-supported response is: The remote attachment comes Up and the Epipe reports end-to-end operational service.