cert
cert-1
cert-2

Pass Nokia 4A0-C03 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
4A0-C03 Exam - Verified By Experts
4A0-C03 Premium File

4A0-C03 Premium File

$69.99
$76.99
  • Premium File 145 Questions & Answers. Last Update: Nov 23, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Nokia 4A0-C03 Practice Test 64

Question 630

A hub-and-spoke VPLS needs a traffic flow from one remote spoke to another through the hub, but both service endpoints are incorrectly classified as mesh SDPs. Which measurable result would verify success without relying on assumptions?

  1. All three authorized sites receive required initial discovery frames without cross-tenant exposure.
  2. Observed spoke traffic follows the authorized hub path and meets documented latency expectations.
  3. Approved spoke endpoints communicate through the hub while unrelated mesh loops remain prevented.
  4. Frames reach authorized customer SAPs without inappropriate mesh-to-mesh flooding.

Explanation

Correct Answer

C:

The acceptance measurement for this case is: Approved spoke endpoints communicate through the hub while unrelated mesh loops remain prevented. It establishes that the intended remediation (“Use the supported spoke and hub service design to permit required transit without breaking loop prevention”) was effective and can be corroborated by: Compare traffic from each spoke toward the hub and onward to the destination spoke.

Incorrect Answers

A:

The actual case evidence is: A hub-and-spoke VPLS needs a traffic flow from one remote spoke to another through the hub, but both service endpoints are incorrectly classified as mesh SDPs. The proposed option addresses a different condition: A provider's VPLS service carries known unicast normally to two sites but initial broadcast and unknown-unicast traffic never reaches the third permitted SDP. Confirm the distinction by checking: Inspect remote service endpoint type and split-horizon group membership. The response supported by the evidence is: Approved spoke endpoints communicate through the hub while unrelated mesh loops remain prevented.

B:

The alternative is directed at this separate case: Two remote spokes exchange Ethernet traffic through a hub site, increasing latency, and an operator expects direct point-to-point transmission between every spoke. The present incident is: A hub-and-spoke VPLS needs a traffic flow from one remote spoke to another through the hub, but both service endpoints are incorrectly classified as mesh SDPs. The pertinent verification is: Inspect remote service endpoint type and split-horizon group membership. The action or outcome to select here is: Approved spoke endpoints communicate through the hub while unrelated mesh loops remain prevented.

D:

The alternative applies to another situation: A multipoint VPLS configuration attempts to relay a frame received from one mesh SDP toward another mesh SDP, generating duplicate copies in a provider-side ring. The reported case instead states: A hub-and-spoke VPLS needs a traffic flow from one remote spoke to another through the hub, but both service endpoints are incorrectly classified as mesh SDPs. The distinguishing check is: Inspect remote service endpoint type and split-horizon group membership. The supported action or criterion is: Approved spoke endpoints communicate through the hub while unrelated mesh loops remain prevented.

Question 631

An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Which change most directly addresses the observed problem?

  1. Diagnose the remote attachment status rather than changing the already healthy transport LSP.
  2. Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
  3. Attach the approved IES interface to the proper global routed service context.
  4. Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.

Explanation

Correct Answer

D:

The fault stated in this case is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The specific corrective action is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends. Confirm it with: Inspect service ID, far-end and signaling state at both Epipe endpoints. The expected end-to-end outcome is: The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire.

Incorrect Answers

A:

The alternative is directed at this separate case: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The present incident is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The pertinent verification is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The action or outcome to select here is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.

B:

This choice does not address the stated situation: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Its competing context is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The relevant diagnostic is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The case-supported response is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.

C:

The alternative applies to another situation: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. The reported case instead states: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The distinguishing check is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The supported action or criterion is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.

Question 632

An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Which TWO independent checks would best establish what is happening? (Select TWO.)

  1. Inspect the service SAP port identifier and incoming VLAN tags on a synthetic frame.
  2. Inspect service ID, far-end and signaling state at both Epipe endpoints.
  3. Inspect IES interface association and learned routes for the customer handoff.
  4. Inspect the service traceroute endpoint and service binding configuration at both PEs.
  5. Compare both configurations with the contracted point-to-point circuit record.

Explanation

Correct Answers

B:

This is a direct diagnostic for the reported fault: Inspect service ID, far-end and signaling state at both Epipe endpoints. A second independent check is: Compare both configurations with the contracted point-to-point circuit record. Combined evidence distinguishes the fault before implementing: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.

E:

This is a direct diagnostic for the reported fault: Compare both configurations with the contracted point-to-point circuit record. A second independent check is: Inspect service ID, far-end and signaling state at both Epipe endpoints. Combined evidence distinguishes the fault before implementing: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.

Incorrect Answers

A:

This choice does not address the stated situation: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Its competing context is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The relevant diagnostic is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The case-supported response is: Inspect service ID, far-end and signaling state at both Epipe endpoints; and Compare both configurations with the contracted point-to-point circuit record.

C:

These other facts could justify the alternative: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. They differ from the stated case: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Test the distinction using: Inspect service ID, far-end and signaling state at both Epipe endpoints. The case-specific response is: Inspect service ID, far-end and signaling state at both Epipe endpoints; and Compare both configurations with the contracted point-to-point circuit record.

D:

The actual case evidence is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The proposed option addresses a different condition: An operations engineer uses service traceroute to reach the intended remote provider edge but the Epipe still reports an invalid remote service binding. Confirm the distinction by checking: Inspect service ID, far-end and signaling state at both Epipe endpoints. The response supported by the evidence is: Inspect service ID, far-end and signaling state at both Epipe endpoints; and Compare both configurations with the contracted point-to-point circuit record.

Question 633

An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. What is the key technical or security failure this situation can produce?

  1. A transport-ready pseudowire cannot provide end-to-end service if a required CE handoff is down.
  2. Confusing IES with VPRN can cause missing reachability or unintended private-route exposure.
  3. A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.
  4. A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.

Explanation

Correct Answer

D:

The observed condition is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The principal operational or security impact is: A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable. The supported repair is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The reported case instead states: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The distinguishing check is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The supported action or criterion is: A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.

B:

These other facts could justify the alternative: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. They differ from the stated case: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Test the distinction using: Inspect service ID, far-end and signaling state at both Epipe endpoints. The case-specific response is: A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.

C:

The actual case evidence is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The proposed option addresses a different condition: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Confirm the distinction by checking: Inspect service ID, far-end and signaling state at both Epipe endpoints. The response supported by the evidence is: A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.

Question 634

An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Choose TWO complementary steps: one repair and one precaution against collateral impact. (Select TWO.)

  1. Update the approved remote PE endpoint and transport resolution for the affected service distribution point.
  2. Reconcile the exact approved pseudowire service identifier and remote attachment on both ends.
  3. Coordinate changes across both PEs with a test VLAN and documented rollback.
  4. Verify service identifier and SDP attachment consistency after confirming transport reachability.
  5. Correct the specific customer SAP port and encapsulation binding without modifying other tenants.

Explanation

Correct Answers

B:

This is the required technical repair: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends. The separately necessary deployment safeguard is: Coordinate changes across both PEs with a test VLAN and documented rollback. Together they address: A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.

C:

This safeguard prevents unwanted collateral effects: Coordinate changes across both PEs with a test VLAN and documented rollback. Its complementary corrective change is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends. Both are required because: A pseudowire signaling mismatch can make an otherwise healthy physical circuit appear unavailable.

Incorrect Answers

A:

These other facts could justify the alternative: A multipoint Nokia VPN is healthy at its local access ports but its SDP references a remote provider edge removed during a metro replacement. They differ from the stated case: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Test the distinction using: Inspect service ID, far-end and signaling state at both Epipe endpoints. The case-specific response is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends; and Coordinate changes across both PEs with a test VLAN and documented rollback.

D:

This choice does not address the stated situation: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Its competing context is: An operations engineer uses service traceroute to reach the intended remote provider edge but the Epipe still reports an invalid remote service binding. The relevant diagnostic is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The case-supported response is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends; and Coordinate changes across both PEs with a test VLAN and documented rollback.

E:

The alternative applies to another situation: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The reported case instead states: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The distinguishing check is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The supported action or criterion is: Reconcile the exact approved pseudowire service identifier and remote attachment on both ends; and Coordinate changes across both PEs with a test VLAN and documented rollback.

Question 635

An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. What evidence would demonstrate that the intended fix worked correctly?

  1. Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
  2. The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire.
  3. The remote attachment comes Up and the Epipe reports end-to-end operational service.
  4. The subscriber obtains intended shared routed connectivity with no unauthorized VPN imports.

Explanation

Correct Answer

B:

The acceptance measurement for this case is: The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire. It establishes that the intended remediation (“Reconcile the exact approved pseudowire service identifier and remote attachment on both ends”) was effective and can be corroborated by: Compare both configurations with the contracted point-to-point circuit record.

Incorrect Answers

A:

The actual case evidence is: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The proposed option addresses a different condition: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. Confirm the distinction by checking: Inspect service ID, far-end and signaling state at both Epipe endpoints. The response supported by the evidence is: The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire.

C:

This choice does not address the stated situation: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The case-supported response is: The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire.

D:

The alternative applies to another situation: An IES customer attachment is accidentally provisioned in a private routed VPN context, preventing intended access to the provider's shared internet routing environment. The reported case instead states: An Ethernet private wire is provisioned on two PE routers, but one PE expects a different pseudowire/service identifier, leaving the local access link Up and the Epipe Down. The distinguishing check is: Inspect service ID, far-end and signaling state at both Epipe endpoints. The supported action or criterion is: The intended two endpoint SAPs exchange only approved customer frames over an Up pseudowire.

Question 636

A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Which corrective action best resolves this particular network fault?

  1. Differentiate transport and service reachability from the customer edge policy and correct only the authorized filter.
  2. Correct the specific customer SAP port and encapsulation binding without modifying other tenants.
  3. Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.
  4. Troubleshoot the customer service attachment separately from the operational SDP transport test.

Explanation

Correct Answer

C:

The fault stated in this case is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The specific corrective action is: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff. Confirm it with: Capture synthetic frames at both access ports and compare VLAN tag presence. The expected end-to-end outcome is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.

Incorrect Answers

A:

The alternative is directed at this separate case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The present incident is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The pertinent verification is: Capture synthetic frames at both access ports and compare VLAN tag presence. The action or outcome to select here is: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.

B:

This choice does not address the stated situation: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Its competing context is: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The relevant diagnostic is: Capture synthetic frames at both access ports and compare VLAN tag presence. The case-supported response is: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.

D:

These other facts could justify the alternative: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. They differ from the stated case: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Test the distinction using: Capture synthetic frames at both access ports and compare VLAN tag presence. The case-specific response is: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.

Question 637

A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Before proposing a change, which TWO observations would give the most useful confirmation? (Select TWO.)

  1. Capture synthetic frames at both access ports and compare VLAN tag presence.
  2. Inspect the SAP's VLAN tag association and customer ingress discard counters.
  3. Inspect egress SAP encapsulation and any configured VLAN rewrite behavior.
  4. Inspect ingress and egress SAP size limits alongside SDP tunnel MTU.
  5. Inspect service OAM result and remote SAP policy drop counters together.

Explanation

Correct Answers

A:

This is a direct diagnostic for the reported fault: Capture synthetic frames at both access ports and compare VLAN tag presence. A second independent check is: Inspect egress SAP encapsulation and any configured VLAN rewrite behavior. Combined evidence distinguishes the fault before implementing: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.

C:

This is a direct diagnostic for the reported fault: Inspect egress SAP encapsulation and any configured VLAN rewrite behavior. A second independent check is: Capture synthetic frames at both access ports and compare VLAN tag presence. Combined evidence distinguishes the fault before implementing: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.

Incorrect Answers

B:

The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The distinguishing check is: Capture synthetic frames at both access ports and compare VLAN tag presence. The supported action or criterion is: Capture synthetic frames at both access ports and compare VLAN tag presence; and Inspect egress SAP encapsulation and any configured VLAN rewrite behavior.

D:

The actual case evidence is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The proposed option addresses a different condition: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. Confirm the distinction by checking: Capture synthetic frames at both access ports and compare VLAN tag presence. The response supported by the evidence is: Capture synthetic frames at both access ports and compare VLAN tag presence; and Inspect egress SAP encapsulation and any configured VLAN rewrite behavior.

E:

The alternative is directed at this separate case: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. The present incident is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The pertinent verification is: Capture synthetic frames at both access ports and compare VLAN tag presence. The action or outcome to select here is: Capture synthetic frames at both access ports and compare VLAN tag presence; and Inspect egress SAP encapsulation and any configured VLAN rewrite behavior.

Question 638

A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Which statement best describes the immediate risk of ignoring this problem?

  1. Transport OAM success does not guarantee correct attachment or customer encapsulation.
  2. A link may be operational while mismatched tags cause the customer endpoint to reject frames.
  3. A green transport or SDP check cannot establish application reachability through customer filters.
  4. A wrong SAP can black-hole customer Ethernet frames or accidentally cross service boundaries.

Explanation

Correct Answer

B:

The observed condition is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The principal operational or security impact is: A link may be operational while mismatched tags cause the customer endpoint to reject frames. The supported repair is: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The distinguishing check is: Capture synthetic frames at both access ports and compare VLAN tag presence. The supported action or criterion is: A link may be operational while mismatched tags cause the customer endpoint to reject frames.

C:

The actual case evidence is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Capture synthetic frames at both access ports and compare VLAN tag presence. The response supported by the evidence is: A link may be operational while mismatched tags cause the customer endpoint to reject frames.

D:

The alternative is directed at this separate case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The present incident is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The pertinent verification is: Capture synthetic frames at both access ports and compare VLAN tag presence. The action or outcome to select here is: A link may be operational while mismatched tags cause the customer endpoint to reject frames.

Question 639

A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Which TWO measures together address the fault while protecting other services? (Select TWO.)

  1. Verify MTU at both customer attachment endpoints and the transport service overhead.
  2. Pilot tagged and untagged frames without touching adjacent tenant VLANs.
  3. Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.
  4. Diagnose the remote attachment status rather than changing the already healthy transport LSP.
  5. Troubleshoot the customer service attachment separately from the operational SDP transport test.

Explanation

Correct Answers

B:

This safeguard prevents unwanted collateral effects: Pilot tagged and untagged frames without touching adjacent tenant VLANs. Its complementary corrective change is: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff. Both are required because: A link may be operational while mismatched tags cause the customer endpoint to reject frames.

C:

This is the required technical repair: Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff. The separately necessary deployment safeguard is: Pilot tagged and untagged frames without touching adjacent tenant VLANs. Together they address: A link may be operational while mismatched tags cause the customer endpoint to reject frames.

Incorrect Answers

A:

These other facts could justify the alternative: A large Ethernet packet crosses the provider tunnel but fails at a smaller remote customer-facing SAP, while the source reports a successful MPLS LSP. They differ from the stated case: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Test the distinction using: Capture synthetic frames at both access ports and compare VLAN tag presence. The case-specific response is: Pilot tagged and untagged frames without touching adjacent tenant VLANs; and Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.

D:

This choice does not address the stated situation: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. Its competing context is: A local Epipe shows an operational MPLS tunnel but remains unavailable because the remote PE reports its customer-facing attachment circuit Down. The relevant diagnostic is: Capture synthetic frames at both access ports and compare VLAN tag presence. The case-supported response is: Pilot tagged and untagged frames without touching adjacent tenant VLANs; and Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.

E:

The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The distinguishing check is: Capture synthetic frames at both access ports and compare VLAN tag presence. The supported action or criterion is: Pilot tagged and untagged frames without touching adjacent tenant VLANs; and Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff.

Question 640

A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. After the approved repair, which outcome best demonstrates that this exact fault is resolved?

  1. The contracted customer application passes while unapproved access remains blocked.
  2. Only the intended customer's VLAN frames enter the Epipe and tenant separation remains intact.
  3. The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.
  4. Both the SDP OAM and end-to-end authorized customer frame forwarding succeed.

Explanation

Correct Answer

C:

The acceptance measurement for this case is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly. It establishes that the intended remediation (“Align authorized SAP encapsulation and any required service VLAN translation with the customer handoff”) was effective and can be corroborated by: Inspect egress SAP encapsulation and any configured VLAN rewrite behavior.

Incorrect Answers

A:

The actual case evidence is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The proposed option addresses a different condition: A provider's Epipe service-level OAM reaches the far PE but the remote CE cannot access its application because a customer-facing ingress filter denies the expected frames. Confirm the distinction by checking: Capture synthetic frames at both access ports and compare VLAN tag presence. The response supported by the evidence is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.

B:

The alternative is directed at this separate case: A Nokia 7750 SR Epipe uses the correct physical customer port but its SAP binds to a different VLAN than the contracted Ethernet handoff. The present incident is: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The pertinent verification is: Capture synthetic frames at both access ports and compare VLAN tag presence. The action or outcome to select here is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.

D:

The alternative applies to another situation: A provider's SDP-level OAM confirms reachability to the remote PE, but customer frames fail because the access SAP is configured for the wrong VLAN. The reported case instead states: A customer sends untagged Ethernet frames at one Epipe handoff but the remote appliance requires VLAN 410 tags, and the current service configuration removes that tag. The distinguishing check is: Capture synthetic frames at both access ports and compare VLAN tag presence. The supported action or criterion is: The remote appliance receives its expected frame encapsulation and the private wire forwards correctly.

Nokia NRS II Composite: IS-IS version (4A0-C03) Practice Tests