cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 75

Question 740

An administrator changes a persistent alias-to-WWPN mapping and zone operations on peer switches still reference the old value. The observed failure is: inconsistent aliases complicate zoning and can direct operators toward obsolete SAN identities. What should the engineer do to recover and validate the service?

  1. The controlled remediation is to convert aliases into arbitrary IPv4 hostnames to make FC zoning work.
  2. The controlled remediation is to use duplicate aliases for unrelated WWPNs without tracing identity.
  3. The controlled remediation is to assume an uncommitted local alias edit automatically updates every switch.
  4. The controlled remediation is to commit or distribute the verified alias database and confirm active zones resolve to the intended WWPNs.

Explanation

Correct Answer

D:

Validate against device-alias database per switch, current CFS session, alias target WWPN and distribution consistency. Fabric-wide device aliases require supported database management and consistent references across switches.

Incorrect Answers

A:

Convert aliases into arbitrary IPv4 hostnames to make FC zoning work. This would not reliably restore service after the stated fault. Inconsistent aliases complicate zoning and can direct operators toward obsolete SAN identities. The controlled recovery is to commit or distribute the verified alias database and confirm active zones resolve to the intended WWPNs.

B:

Use duplicate aliases for unrelated WWPNs without tracing identity. This would not reliably restore service after the stated fault. Inconsistent aliases complicate zoning and can direct operators toward obsolete SAN identities. The controlled recovery is to commit or distribute the verified alias database and confirm active zones resolve to the intended WWPNs.

C:

Assume an uncommitted local alias edit automatically updates every switch. This would not reliably restore service after the stated fault. Inconsistent aliases complicate zoning and can direct operators toward obsolete SAN identities. The controlled recovery is to commit or distribute the verified alias database and confirm active zones resolve to the intended WWPNs.

Question 741

An MDS interface connected to a host HBA is configured as an inter-switch E-port instead of an end-device F-port. Which operator action best meets this technical requirement?

  1. Choose compatible Fibre Channel port roles and negotiate the appropriate fabric or end-device connection.
  2. Set every FC interface to an Ethernet access port.
  3. Assume any physical link light means FC port roles are compatible.
  4. Assign an L3 BGP peer instead of choosing FC port mode.

Explanation

Correct Answer

A:

This directly addresses Fibre Channel physical port roles because f-ports serve node devices while E-ports join Fibre Channel switches into a fabric. Confirm the change against interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

Incorrect Answers

B:

Mismatched port roles can prevent device logins or inter-switch fabric formation. The relevant correction is to choose compatible Fibre Channel port roles and negotiate the appropriate fabric or end-device connection.

C:

Assume any physical link light means FC port roles are compatible. The proposed change targets the wrong mechanism or lacks essential validation. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric. Relevant evidence is interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

D:

Mismatched port roles can prevent device logins or inter-switch fabric formation. The appropriate action remains to choose compatible Fibre Channel port roles and negotiate the appropriate fabric or end-device connection.

Question 742

An MDS interface connected to a host HBA is configured as an inter-switch E-port instead of an end-device F-port. Which collection of observations most directly tests the suspected cause?

  1. A storage vendor slogan without the relevant login and path counters.
  2. Interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.
  3. A green physical FC link light without fabric login, zoning or I/O evidence.
  4. A historical FC topology drawing with no current WWPN or port state.

Explanation

Correct Answer

B:

These observations test the actual Fibre Channel physical port roles mechanism rather than a superficial management status. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

Incorrect Answers

A:

A storage vendor slogan without the relevant login and path counters. This information cannot independently verify Fibre Channel physical port roles. The decisive records instead include interface operational FC port mode, neighbor type, FLOGI and E-port initialization status. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

C:

A green physical FC link light without fabric login, zoning or I/O evidence. This information cannot independently verify Fibre Channel physical port roles. The decisive records instead include interface operational FC port mode, neighbor type, FLOGI and E-port initialization status. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

D:

A historical FC topology drawing with no current WWPN or port state. This information cannot independently verify Fibre Channel physical port roles. The decisive records instead include interface operational FC port mode, neighbor type, FLOGI and E-port initialization status. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

Question 743

An MDS interface connected to a host HBA is configured as an inter-switch E-port instead of an end-device F-port. Which statement most accurately explains this scenario?

  1. A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
  2. An unused VSAN number can replace an active zoning or port security rule.
  3. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.
  4. Every storage protocol provides the same file and block semantics.

Explanation

Correct Answer

C:

Validation depends on interface operational FC port mode, neighbor type, FLOGI and E-port initialization status. This explains why the most appropriate response is to choose compatible Fibre Channel port roles and negotiate the appropriate fabric or end-device connection.

Incorrect Answers

A:

A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for Fibre Channel physical port roles. The applicable technical behavior is that f-ports serve node devices while E-ports join Fibre Channel switches into a fabric. The operator should verify interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

B:

An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for Fibre Channel physical port roles. The applicable technical behavior is that f-ports serve node devices while E-ports join Fibre Channel switches into a fabric. The operator should verify interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

D:

Every storage protocol provides the same file and block semantics. This is an incorrect generalization for Fibre Channel physical port roles. The applicable technical behavior is that f-ports serve node devices while E-ports join Fibre Channel switches into a fabric. The operator should verify interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

Question 744

An MDS interface connected to a host HBA is configured as an inter-switch E-port instead of an end-device F-port. Assume an engineer instead chooses to set every FC interface to an Ethernet access port. What is the principal technical consequence of the mistaken choice?

  1. Inspecting credit counters prevents FC frames from forwarding.
  2. A well-documented host multipath test is the source of the original fabric fault.
  3. Examining FCNS entries automatically removes the authorized zoning policy.
  4. Mismatched port roles can prevent device logins or inter-switch fabric formation.

Explanation

Correct Answer

D:

The proper corrective action is to choose compatible Fibre Channel port roles and negotiate the appropriate fabric or end-device connection. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

Incorrect Answers

A:

This does not explain the actual Fibre Channel physical port roles defect after the shortcut. The meaningful failure is that mismatched port roles can prevent device logins or inter-switch fabric formation.

B:

This does not explain the actual Fibre Channel physical port roles defect after the shortcut. The relevant evidence is interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

C:

This does not explain the actual Fibre Channel physical port roles defect after the shortcut. Examining FCNS entries automatically removes the authorized zoning policy.

Question 745

An MDS interface connected to a host HBA is configured as an inter-switch E-port instead of an end-device F-port. The observed failure is: mismatched port roles can prevent device logins or inter-switch fabric formation. What should the engineer do to recover and validate the service?

  1. Correct interface roles and verify FLOGI or inter-switch login according to the link purpose.
  2. Assume any physical link light means FC port roles are compatible.
  3. Assign an L3 BGP peer instead of choosing FC port mode.
  4. Set every FC interface to an Ethernet access port.

Explanation

Correct Answer

A:

This addresses the observable fault while preserving a check of the expected result. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

Incorrect Answers

B:

Assume any physical link light means FC port roles are compatible. This would not reliably restore service after the stated fault. Mismatched port roles can prevent device logins or inter-switch fabric formation. The controlled recovery is to correct interface roles and verify FLOGI or inter-switch login according to the link purpose.

C:

Assign an L3 BGP peer instead of choosing FC port mode. This would not reliably restore service after the stated fault. Mismatched port roles can prevent device logins or inter-switch fabric formation. The controlled recovery is to correct interface roles and verify FLOGI or inter-switch login according to the link purpose.

D:

Set every FC interface to an Ethernet access port. This would not reliably restore service after the stated fault. Mismatched port roles can prevent device logins or inter-switch fabric formation. The controlled recovery is to correct interface roles and verify FLOGI or inter-switch login according to the link purpose.

Question 746

A SAN expansion connects two fabric switches but one side remains in a server-facing F-port mode. Which next step should the data center engineer select?

  1. On this affected device, the engineer should assume any physical link light means FC port roles are compatible.
  2. On this affected device, the engineer should choose compatible Fibre Channel port roles and negotiate the appropriate fabric or end-device connection.
  3. On this affected device, the engineer should assign an L3 BGP peer instead of choosing FC port mode.
  4. On this affected device, the engineer should set every FC interface to an Ethernet access port.

Explanation

Correct Answer

B:

This directly addresses Fibre Channel physical port roles because f-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

Incorrect Answers

A:

Assume any physical link light means FC port roles are compatible. The proposed change targets the wrong mechanism or lacks essential validation. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric. Relevant evidence is interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

C:

Mismatched port roles can prevent device logins or inter-switch fabric formation. Assign an L3 BGP peer instead of choosing FC port mode.

D:

Mismatched port roles can prevent device logins or inter-switch fabric formation. In the given case, a SAN expansion connects two fabric switches but one side remains in a server-facing F-port mode.

Question 747

A SAN expansion connects two fabric switches but one side remains in a server-facing F-port mode. Which diagnostic record would most strongly confirm the result?

  1. For this deployment, examine an Ethernet ping that does not test the required SAN session or VSAN.
  2. For this deployment, examine a storage vendor slogan without the relevant login and path counters.
  3. For this deployment, examine interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.
  4. For this deployment, examine a green physical FC link light without fabric login, zoning or I/O evidence.

Explanation

Correct Answer

C:

These observations test the actual Fibre Channel physical port roles mechanism rather than a superficial management status. They should be checked after choose compatible Fibre Channel port roles and negotiate the appropriate fabric or end-device connection.

Incorrect Answers

A:

An Ethernet ping that does not test the required SAN session or VSAN. This information cannot independently verify Fibre Channel physical port roles. The decisive records instead include interface operational FC port mode, neighbor type, FLOGI and E-port initialization status. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

B:

A storage vendor slogan without the relevant login and path counters. This information cannot independently verify Fibre Channel physical port roles. The decisive records instead include interface operational FC port mode, neighbor type, FLOGI and E-port initialization status. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

D:

A green physical FC link light without fabric login, zoning or I/O evidence. This information cannot independently verify Fibre Channel physical port roles. The decisive records instead include interface operational FC port mode, neighbor type, FLOGI and E-port initialization status. F-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

Question 748

A SAN expansion connects two fabric switches but one side remains in a server-facing F-port mode. Which platform concept should guide the engineer’s assessment?

  1. For this condition, the applicable principle is that every storage protocol provides the same file and block semantics.
  2. For this condition, the applicable principle is that a lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
  3. For this condition, the applicable principle is that wWPN zoning and IP access lists are interchangeable security primitives.
  4. For this condition, the applicable principle is that f-ports serve node devices while E-ports join Fibre Channel switches into a fabric.

Explanation

Correct Answer

D:

Validation depends on interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

Incorrect Answers

A:

Every storage protocol provides the same file and block semantics. This is an incorrect generalization for Fibre Channel physical port roles. The applicable technical behavior is that f-ports serve node devices while E-ports join Fibre Channel switches into a fabric. The operator should verify interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

B:

A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for Fibre Channel physical port roles. The applicable technical behavior is that f-ports serve node devices while E-ports join Fibre Channel switches into a fabric. The operator should verify interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

C:

WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for Fibre Channel physical port roles. The applicable technical behavior is that f-ports serve node devices while E-ports join Fibre Channel switches into a fabric. The operator should verify interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

Question 749

A SAN expansion connects two fabric switches but one side remains in a server-facing F-port mode. Assume an engineer instead chooses to set every FC interface to an Ethernet access port. Which root-cause observation follows from that incorrect change?

  1. The resulting defect is that mismatched port roles can prevent device logins or inter-switch fabric formation.
  2. The resulting defect is that examining FCNS entries automatically removes the authorized zoning policy.
  3. The resulting defect is that the SAN failed because operators retained correct WWPN identity records.
  4. The resulting defect is that a well-documented host multipath test is the source of the original fabric fault.

Explanation

Correct Answer

A:

The proper corrective action is to choose compatible Fibre Channel port roles and negotiate the appropriate fabric or end-device connection. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

B:

This does not explain the actual Fibre Channel physical port roles defect after the shortcut. In the given case, a SAN expansion connects two fabric switches but one side remains in a server-facing F-port mode.

C:

This does not explain the actual Fibre Channel physical port roles defect after the shortcut. The SAN failed because operators retained correct WWPN identity records.

D:

This does not explain the actual Fibre Channel physical port roles defect after the shortcut. A well-documented host multipath test is the source of the original fabric fault.

Question 750

A SAN expansion connects two fabric switches but one side remains in a server-facing F-port mode. The observed failure is: mismatched port roles can prevent device logins or inter-switch fabric formation. Which recovery action addresses the underlying technical fault?

  1. The controlled remediation is to assign an L3 BGP peer instead of choosing FC port mode.
  2. The controlled remediation is to correct interface roles and verify FLOGI or inter-switch login according to the link purpose.
  3. The controlled remediation is to set every FC interface to an Ethernet access port.
  4. The controlled remediation is to assume any physical link light means FC port roles are compatible.

Explanation

Correct Answer

B:

This addresses the observable fault while preserving a check of the expected result. Validate against interface operational FC port mode, neighbor type, FLOGI and E-port initialization status.

Incorrect Answers

A:

Assign an L3 BGP peer instead of choosing FC port mode. This would not reliably restore service after the stated fault. Mismatched port roles can prevent device logins or inter-switch fabric formation. The controlled recovery is to correct interface roles and verify FLOGI or inter-switch login according to the link purpose.

C:

Set every FC interface to an Ethernet access port. This would not reliably restore service after the stated fault. Mismatched port roles can prevent device logins or inter-switch fabric formation. The controlled recovery is to correct interface roles and verify FLOGI or inter-switch login according to the link purpose.

D:

Assume any physical link light means FC port roles are compatible. This would not reliably restore service after the stated fault. Mismatched port roles can prevent device logins or inter-switch fabric formation. The controlled recovery is to correct interface roles and verify FLOGI or inter-switch login according to the link purpose.

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests