cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 73

Question 720

A UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support. The observed failure is: without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. What is the BEST controlled recovery once this failure is recognized?

  1. The controlled remediation is to assume NPV is an Ethernet VLAN trunking feature.
  2. The controlled remediation is to assign one shared FCID permanently to all downstream hosts.
  3. The controlled remediation is to configure the edge as a new principal domain without checking the NPV design.
  4. The controlled remediation is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.

Explanation

Correct Answer

D:

This addresses the observable fault while preserving a check of the expected result. Validate against NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.

Incorrect Answers

A:

Assume NPV is an Ethernet VLAN trunking feature. This would not reliably restore service after the stated fault. Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. The controlled recovery is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.

B:

Assign one shared FCID permanently to all downstream hosts. This would not reliably restore service after the stated fault. Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. The controlled recovery is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.

C:

Configure the edge as a new principal domain without checking the NPV design. This would not reliably restore service after the stated fault. Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. The controlled recovery is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.

Question 721

A virtualization host requires multiple virtual WWPN logins over a single physical N-port but the upstream switch refuses additional logins. What is the BEST supported implementation or corrective action?

  1. Enable supported NPIV on the upstream fabric port and validate per-virtual-port registration.
  2. Reassign all virtual HBAs to one duplicate WWPN to conserve addresses.
  3. Assume VLAN tagging replaces Fibre Channel virtual logins.
  4. Create OSPF adjacencies for each virtual initiator instead of enabling NPIV.

Explanation

Correct Answer

A:

This directly addresses NPIV multiple virtual initiators because NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. Confirm the change against NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

Incorrect Answers

B:

If NPIV is disabled, additional virtual initiators cannot register independently through the port. The relevant correction is to enable supported NPIV on the upstream fabric port and validate per-virtual-port registration.

C:

Assume VLAN tagging replaces Fibre Channel virtual logins. The proposed change targets the wrong mechanism or lacks essential validation. NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. Relevant evidence is NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

D:

If NPIV is disabled, additional virtual initiators cannot register independently through the port. The appropriate action remains to enable supported NPIV on the upstream fabric port and validate per-virtual-port registration.

Question 722

A virtualization host requires multiple virtual WWPN logins over a single physical N-port but the upstream switch refuses additional logins. Which evidence BEST verifies the intended technical behavior?

  1. A green physical FC link light without fabric login, zoning or I/O evidence.
  2. NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.
  3. An Ethernet ping that does not test the required SAN session or VSAN.
  4. A storage vendor slogan without the relevant login and path counters.

Explanation

Correct Answer

B:

These observations test the actual NPIV multiple virtual initiators mechanism rather than a superficial management status. NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric.

Incorrect Answers

A:

This information cannot independently verify NPIV multiple virtual initiators. The decisive records instead include NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

C:

This information cannot independently verify NPIV multiple virtual initiators. NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric.

D:

This information cannot independently verify NPIV multiple virtual initiators. A storage vendor slogan without the relevant login and path counters.

Question 723

A virtualization host requires multiple virtual WWPN logins over a single physical N-port but the upstream switch refuses additional logins. Which principle BEST explains why the recommended solution is appropriate?

  1. WWPN zoning and IP access lists are interchangeable security primitives.
  2. Every storage protocol provides the same file and block semantics.
  3. NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric.
  4. A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.

Explanation

Correct Answer

C:

Validation depends on NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries. This explains why the most appropriate response is to enable supported NPIV on the upstream fabric port and validate per-virtual-port registration.

Incorrect Answers

A:

WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for NPIV multiple virtual initiators. The applicable technical behavior is that NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. The operator should verify NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

B:

Every storage protocol provides the same file and block semantics. This is an incorrect generalization for NPIV multiple virtual initiators. The applicable technical behavior is that NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. The operator should verify NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

D:

A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for NPIV multiple virtual initiators. The applicable technical behavior is that NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. The operator should verify NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

Question 724

A virtualization host requires multiple virtual WWPN logins over a single physical N-port but the upstream switch refuses additional logins. Assume an engineer instead chooses to reassign all virtual HBAs to one duplicate WWPN to conserve addresses. What is the MOST significant failure introduced by that shortcut?

  1. A well-documented host multipath test is the source of the original fabric fault.
  2. Examining FCNS entries automatically removes the authorized zoning policy.
  3. The SAN failed because operators retained correct WWPN identity records.
  4. If NPIV is disabled, additional virtual initiators cannot register independently through the port.

Explanation

Correct Answer

D:

NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

A:

This does not explain the actual NPIV multiple virtual initiators defect after the shortcut. The meaningful failure is that if NPIV is disabled, additional virtual initiators cannot register independently through the port.

B:

This does not explain the actual NPIV multiple virtual initiators defect after the shortcut. The relevant evidence is NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

C:

This does not explain the actual NPIV multiple virtual initiators defect after the shortcut. The SAN failed because operators retained correct WWPN identity records.

Question 725

A virtualization host requires multiple virtual WWPN logins over a single physical N-port but the upstream switch refuses additional logins. The observed failure is: if NPIV is disabled, additional virtual initiators cannot register independently through the port. What is the BEST controlled recovery once this failure is recognized?

  1. Correct NPIV support and limits and confirm each virtual initiator has a distinct login.
  2. Assume VLAN tagging replaces Fibre Channel virtual logins.
  3. Create OSPF adjacencies for each virtual initiator instead of enabling NPIV.
  4. Reassign all virtual HBAs to one duplicate WWPN to conserve addresses.

Explanation

Correct Answer

A:

NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. This addresses the observable fault while preserving a check of the expected result.

Incorrect Answers

B:

Assume VLAN tagging replaces Fibre Channel virtual logins. This would not reliably restore service after the stated fault. If NPIV is disabled, additional virtual initiators cannot register independently through the port. The controlled recovery is to correct NPIV support and limits and confirm each virtual initiator has a distinct login.

C:

Create OSPF adjacencies for each virtual initiator instead of enabling NPIV. This would not reliably restore service after the stated fault. If NPIV is disabled, additional virtual initiators cannot register independently through the port. The controlled recovery is to correct NPIV support and limits and confirm each virtual initiator has a distinct login.

D:

Reassign all virtual HBAs to one duplicate WWPN to conserve addresses. This would not reliably restore service after the stated fault. If NPIV is disabled, additional virtual initiators cannot register independently through the port. The controlled recovery is to correct NPIV support and limits and confirm each virtual initiator has a distinct login.

Question 726

An MDS F-port learns only the first virtual HBA and rejects others when a blade hypervisor starts more VMs. Which configuration decision MOST directly resolves the issue?

  1. On this affected device, the engineer should assume VLAN tagging replaces Fibre Channel virtual logins.
  2. On this affected device, the engineer should enable supported NPIV on the upstream fabric port and validate per-virtual-port registration.
  3. On this affected device, the engineer should create OSPF adjacencies for each virtual initiator instead of enabling NPIV.
  4. On this affected device, the engineer should reassign all virtual HBAs to one duplicate WWPN to conserve addresses.

Explanation

Correct Answer

B:

This directly addresses NPIV multiple virtual initiators because NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric.

Incorrect Answers

A:

Assume VLAN tagging replaces Fibre Channel virtual logins. The proposed change targets the wrong mechanism or lacks essential validation. NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. Relevant evidence is NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

C:

If NPIV is disabled, additional virtual initiators cannot register independently through the port. Create OSPF adjacencies for each virtual initiator instead of enabling NPIV.

D:

If NPIV is disabled, additional virtual initiators cannot register independently through the port. In the given case, an MDS F-port learns only the first virtual HBA and rejects others when a blade hypervisor starts more VMs.

Question 727

An MDS F-port learns only the first virtual HBA and rejects others when a blade hypervisor starts more VMs. What should the engineer inspect to confirm the actual state?

  1. For this deployment, examine a copied zoneset name without its active effective members.
  2. For this deployment, examine a green physical FC link light without fabric login, zoning or I/O evidence.
  3. For this deployment, examine NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.
  4. For this deployment, examine an Ethernet ping that does not test the required SAN session or VSAN.

Explanation

Correct Answer

C:

These observations test the actual NPIV multiple virtual initiators mechanism rather than a superficial management status. They should be checked after enable supported NPIV on the upstream fabric port and validate per-virtual-port registration.

Incorrect Answers

A:

This information cannot independently verify NPIV multiple virtual initiators. A copied zoneset name without its active effective members.

B:

This information cannot independently verify NPIV multiple virtual initiators. A green physical FC link light without fabric login, zoning or I/O evidence.

D:

This information cannot independently verify NPIV multiple virtual initiators. An Ethernet ping that does not test the required SAN session or VSAN.

Question 728

An MDS F-port learns only the first virtual HBA and rejects others when a blade hypervisor starts more VMs. What technical behavior underlies the correct decision?

  1. For this condition, the applicable principle is that a lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
  2. For this condition, the applicable principle is that wWPN zoning and IP access lists are interchangeable security primitives.
  3. For this condition, the applicable principle is that Fibre Channel name service entries are identical to host multipath device state.
  4. For this condition, the applicable principle is that NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric.

Explanation

Correct Answer

D:

Validation depends on NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

Incorrect Answers

A:

A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for NPIV multiple virtual initiators. The applicable technical behavior is that NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. The operator should verify NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

B:

WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for NPIV multiple virtual initiators. The applicable technical behavior is that NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. The operator should verify NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

C:

Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for NPIV multiple virtual initiators. The applicable technical behavior is that NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. The operator should verify NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

Question 729

An MDS F-port learns only the first virtual HBA and rejects others when a blade hypervisor starts more VMs. Assume an engineer instead chooses to reassign all virtual HBAs to one duplicate WWPN to conserve addresses. Which resulting risk or fault should the reviewer identify?

  1. The resulting defect is that if NPIV is disabled, additional virtual initiators cannot register independently through the port.
  2. The resulting defect is that the SAN failed because operators retained correct WWPN identity records.
  3. The resulting defect is that the sole error was using a verified SAN maintenance window for a risky operation.
  4. The resulting defect is that examining FCNS entries automatically removes the authorized zoning policy.

Explanation

Correct Answer

A:

NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. The proper corrective action is to enable supported NPIV on the upstream fabric port and validate per-virtual-port registration.

Incorrect Answers

B:

The SAN failed because operators retained correct WWPN identity records. This does not explain the actual NPIV multiple virtual initiators defect after the shortcut. The meaningful failure is that if NPIV is disabled, additional virtual initiators cannot register independently through the port. The relevant evidence is NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

C:

The sole error was using a verified SAN maintenance window for a risky operation. This does not explain the actual NPIV multiple virtual initiators defect after the shortcut. The meaningful failure is that if NPIV is disabled, additional virtual initiators cannot register independently through the port. The relevant evidence is NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

D:

Examining FCNS entries automatically removes the authorized zoning policy. This does not explain the actual NPIV multiple virtual initiators defect after the shortcut. The meaningful failure is that if NPIV is disabled, additional virtual initiators cannot register independently through the port. The relevant evidence is NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

Question 730

An MDS F-port learns only the first virtual HBA and rejects others when a blade hypervisor starts more VMs. The observed failure is: if NPIV is disabled, additional virtual initiators cannot register independently through the port. Which remediation most directly restores the intended behavior?

  1. The controlled remediation is to create OSPF adjacencies for each virtual initiator instead of enabling NPIV.
  2. The controlled remediation is to correct NPIV support and limits and confirm each virtual initiator has a distinct login.
  3. The controlled remediation is to reassign all virtual HBAs to one duplicate WWPN to conserve addresses.
  4. The controlled remediation is to assume VLAN tagging replaces Fibre Channel virtual logins.

Explanation

Correct Answer

B:

NPIV allows multiple distinct N-port identities to share the same physical connection to a Fibre Channel fabric. Validate against NPIV capability and limits, upstream F-port state, individual virtual WWPN FLOGI entries.

Incorrect Answers

A:

Create OSPF adjacencies for each virtual initiator instead of enabling NPIV. This would not reliably restore service after the stated fault. If NPIV is disabled, additional virtual initiators cannot register independently through the port. The controlled recovery is to correct NPIV support and limits and confirm each virtual initiator has a distinct login.

C:

Reassign all virtual HBAs to one duplicate WWPN to conserve addresses. This would not reliably restore service after the stated fault. If NPIV is disabled, additional virtual initiators cannot register independently through the port. The controlled recovery is to correct NPIV support and limits and confirm each virtual initiator has a distinct login.

D:

Assume VLAN tagging replaces Fibre Channel virtual logins. This would not reliably restore service after the stated fault. If NPIV is disabled, additional virtual initiators cannot register independently through the port. The controlled recovery is to correct NPIV support and limits and confirm each virtual initiator has a distinct login.

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests