Cisco 350-601 Practice Test 72
Question 710
A SAN team adds a new VSAN yet forgets to permit it on the E-port trunk connecting two fabric switches. The observed failure is: a VSAN omitted from the ISL trunk remains locally isolated despite healthy physical fabric links. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to disable trunking without arranging alternate VSAN transport.
- The controlled remediation is to correct the allowed VSAN set and verify end-to-end fabric services in that VSAN.
- The controlled remediation is to enable unrelated Ethernet VLANs and expect them to pass FC E-port traffic.
- The controlled remediation is to make every inter-switch port an F-port for server initiators.
Explanation
Correct Answer
B:Validate against FC trunk allowed VSAN list, VSAN operational state, ISL E-port status and peer FCNS reachability. Fibre Channel trunking carries only configured or permitted VSAN traffic across an inter-switch connection.
Incorrect Answers
A:Disable trunking without arranging alternate VSAN transport. This would not reliably restore service after the stated fault. A VSAN omitted from the ISL trunk remains locally isolated despite healthy physical fabric links. The controlled recovery is to correct the allowed VSAN set and verify end-to-end fabric services in that VSAN.
C:Enable unrelated Ethernet VLANs and expect them to pass FC E-port traffic. This would not reliably restore service after the stated fault. A VSAN omitted from the ISL trunk remains locally isolated despite healthy physical fabric links. The controlled recovery is to correct the allowed VSAN set and verify end-to-end fabric services in that VSAN.
D:Make every inter-switch port an F-port for server initiators. This would not reliably restore service after the stated fault. A VSAN omitted from the ISL trunk remains locally isolated despite healthy physical fabric links. The controlled recovery is to correct the allowed VSAN set and verify end-to-end fabric services in that VSAN.
Question 711
An upstream MDS fabric needs to connect many blade-server HBAs without consuming a separate FC switch domain for each access device. Which next step should the data center engineer select?
- Assign one shared FCID permanently to all downstream hosts.
- Configure the edge as a new principal domain without checking the NPV design.
- Use a supported NPV edge design with upstream NPIV capability and verify initiator proxy logins.
- Assume NPV is an Ethernet VLAN trunking feature.
Explanation
Correct Answer
C:This directly addresses NPV mode host-edge design because n-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric. Confirm the change against NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
Incorrect Answers
A:Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. The relevant correction is to use a supported NPV edge design with upstream NPIV capability and verify initiator proxy logins.
B:That option concerns for each access device. This directly addresses NPV mode host-edge design because n-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
D:Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. The appropriate action remains to use a supported NPV edge design with upstream NPIV capability and verify initiator proxy logins.
Question 712
An upstream MDS fabric needs to connect many blade-server HBAs without consuming a separate FC switch domain for each access device. Which diagnostic record would most strongly confirm the result?
- A historical FC topology drawing with no current WWPN or port state.
- A storage vendor slogan without the relevant login and path counters.
- A copied zoneset name without its active effective members.
- NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
Explanation
Correct Answer
D:These observations test the actual NPV mode host-edge design mechanism rather than a superficial management status. N-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
Incorrect Answers
A:This information cannot independently verify NPV mode host-edge design. The decisive records instead include NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
B:This information cannot independently verify NPV mode host-edge design. N-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
C:This information cannot independently verify NPV mode host-edge design. A copied zoneset name without its active effective members.
Question 713
An upstream MDS fabric needs to connect many blade-server HBAs without consuming a separate FC switch domain for each access device. Which platform concept should guide the engineer’s assessment?
- N-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
- Every storage protocol provides the same file and block semantics.
- Fibre Channel name service entries are identical to host multipath device state.
- An unused VSAN number can replace an active zoning or port security rule.
Explanation
Correct Answer
A:Validation depends on NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility. This explains why the most appropriate response is to use a supported NPV edge design with upstream NPIV capability and verify initiator proxy logins.
Incorrect Answers
B:That option concerns for each access device. Validation depends on NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility. The applicable technical behavior is that n-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
C:That option concerns for each access device. Validation depends on NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility. This is an incorrect generalization for NPV mode host-edge design.
D:That option concerns for each access device. Validation depends on NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility. An unused VSAN number can replace an active zoning or port security rule.
Question 714
An upstream MDS fabric needs to connect many blade-server HBAs without consuming a separate FC switch domain for each access device. Assume an engineer instead chooses to assign one shared FCID permanently to all downstream hosts. Which root-cause observation follows from that incorrect change?
- The sole error was using a verified SAN maintenance window for a risky operation.
- Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity.
- Inspecting credit counters prevents FC frames from forwarding.
- A well-documented host multipath test is the source of the original fabric fault.
Explanation
Correct Answer
B:The proper corrective action is to use a supported NPV edge design with upstream NPIV capability and verify initiator proxy logins. N-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
Incorrect Answers
A:This does not explain the actual NPV mode host-edge design defect after the shortcut. The meaningful failure is that without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity.
C:This does not explain the actual NPV mode host-edge design defect after the shortcut. The relevant evidence is NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
D:This does not explain the actual NPV mode host-edge design defect after the shortcut. In the given case, an upstream MDS fabric needs to connect many blade-server HBAs without consuming a separate FC switch domain for each access device.
Question 715
An upstream MDS fabric needs to connect many blade-server HBAs without consuming a separate FC switch domain for each access device. The observed failure is: without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. Which recovery action addresses the underlying technical fault?
- Configure the edge as a new principal domain without checking the NPV design.
- Assume NPV is an Ethernet VLAN trunking feature.
- Enable and confirm the intended NPV or NPIV roles and validate individual host logins.
- Assign one shared FCID permanently to all downstream hosts.
Explanation
Correct Answer
C:This addresses the observable fault while preserving a check of the expected result. N-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
Incorrect Answers
A:That option concerns for each access device. This addresses the observable fault while preserving a check of the expected result. Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity.
B:That option concerns for each access device. This addresses the observable fault while preserving a check of the expected result. This would not reliably restore service after the stated fault.
D:That option concerns for each access device. This addresses the observable fault while preserving a check of the expected result. The controlled recovery is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.
Question 716
A UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support. What is the BEST supported implementation or corrective action?
- On this affected device, the engineer should configure the edge as a new principal domain without checking the NPV design.
- On this affected device, the engineer should assume NPV is an Ethernet VLAN trunking feature.
- On this affected device, the engineer should assign one shared FCID permanently to all downstream hosts.
- On this affected device, the engineer should use a supported NPV edge design with upstream NPIV capability and verify initiator proxy logins.
Explanation
Correct Answer
D:This directly addresses NPV mode host-edge design because n-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
Incorrect Answers
A:Configure the edge as a new principal domain without checking the NPV design. The proposed change targets the wrong mechanism or lacks essential validation. N-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric. Relevant evidence is NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
B:Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. In the given case, a UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support.
C:Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. Assign one shared FCID permanently to all downstream hosts.
Question 717
A UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support. Which evidence BEST verifies the intended technical behavior?
- For this deployment, examine NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
- For this deployment, examine a green physical FC link light without fabric login, zoning or I/O evidence.
- For this deployment, examine a historical FC topology drawing with no current WWPN or port state.
- For this deployment, examine a storage vendor slogan without the relevant login and path counters.
Explanation
Correct Answer
A:These observations test the actual NPV mode host-edge design mechanism rather than a superficial management status. They should be checked after use a supported NPV edge design with upstream NPIV capability and verify initiator proxy logins.
Incorrect Answers
B:This information cannot independently verify NPV mode host-edge design. A green physical FC link light without fabric login, zoning or I/O evidence.
C:This information cannot independently verify NPV mode host-edge design. In the given case, a UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support.
D:This information cannot independently verify NPV mode host-edge design. A storage vendor slogan without the relevant login and path counters.
Question 718
A UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support. Which principle BEST explains why the recommended solution is appropriate?
- For this condition, the applicable principle is that an unused VSAN number can replace an active zoning or port security rule.
- For this condition, the applicable principle is that n-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric.
- For this condition, the applicable principle is that every storage protocol provides the same file and block semantics.
- For this condition, the applicable principle is that a lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
Explanation
Correct Answer
B:Validation depends on NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
Incorrect Answers
A:An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for NPV mode host-edge design. The applicable technical behavior is that n-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric. The operator should verify NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
C:Every storage protocol provides the same file and block semantics. This is an incorrect generalization for NPV mode host-edge design. The applicable technical behavior is that n-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric. The operator should verify NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
D:A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for NPV mode host-edge design. The applicable technical behavior is that n-Port Virtualization reduces domain-management complexity by proxying end-host logins to an NPIV-enabled upstream fabric. The operator should verify NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
Question 719
A UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support. Assume an engineer instead chooses to assign one shared FCID permanently to all downstream hosts. What is the MOST significant failure introduced by that shortcut?
- The resulting defect is that a well-documented host multipath test is the source of the original fabric fault.
- The resulting defect is that examining FCNS entries automatically removes the authorized zoning policy.
- The resulting defect is that without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity.
- The resulting defect is that inspecting credit counters prevents FC frames from forwarding.
Explanation
Correct Answer
C:The proper corrective action is to use a supported NPV edge design with upstream NPIV capability and verify initiator proxy logins. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual NPV mode host-edge design defect after the shortcut. In the given case, a UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support.
B:This does not explain the actual NPV mode host-edge design defect after the shortcut. Examining FCNS entries automatically removes the authorized zoning policy.
D:The meaningful failure is that without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity.
Question 720
A UCS FI is incorrectly treated as a full fabric switch rather than an NPIV-capable edge requiring upstream support. The observed failure is: without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. What is the BEST controlled recovery once this failure is recognized?
- The controlled remediation is to assume NPV is an Ethernet VLAN trunking feature.
- The controlled remediation is to assign one shared FCID permanently to all downstream hosts.
- The controlled remediation is to configure the edge as a new principal domain without checking the NPV design.
- The controlled remediation is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.
Explanation
Correct Answer
D:This addresses the observable fault while preserving a check of the expected result. Validate against NPV state, upstream NPIV support, proxy FLOGI entries and host WWPN visibility.
Incorrect Answers
A:Assume NPV is an Ethernet VLAN trunking feature. This would not reliably restore service after the stated fault. Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. The controlled recovery is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.
B:Assign one shared FCID permanently to all downstream hosts. This would not reliably restore service after the stated fault. Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. The controlled recovery is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.
C:Configure the edge as a new principal domain without checking the NPV design. This would not reliably restore service after the stated fault. Without appropriate upstream NPIV support, downstream host logins may fail despite physical connectivity. The controlled recovery is to enable and confirm the intended NPV or NPIV roles and validate individual host logins.