Cisco 350-601 Practice Test 70
Question 690
A SAN maintenance window reveals only one ISL carrying traffic because the intended FC port-channel membership is suspended. The observed failure is: incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. Which remediation most directly restores the intended behavior?
- The controlled remediation is to disable all ISLs before checking interface compatibility.
- The controlled remediation is to correct membership and common attributes, then verify all intended ISLs join the bundle.
- The controlled remediation is to use Ethernet LACP settings alone to establish an MDS FC port channel.
- The controlled remediation is to assign unrelated VSAN membership to each member in a nontrunked bundle.
Explanation
Correct Answer
B:Validate against FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.
Incorrect Answers
A:Disable all ISLs before checking interface compatibility. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.
C:Use Ethernet LACP settings alone to establish an MDS FC port channel. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.
D:Assign unrelated VSAN membership to each member in a nontrunked bundle. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.
Question 691
A storage team places development and production initiators into one common VSAN and creates unintended shared name-service visibility. Which configuration decision MOST directly resolves the issue?
- Treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration.
- Assign all SAN ports to a default VSAN to bypass isolation controls.
- Place the relevant FC ports and zoning in the correct logically isolated VSAN.
- Edit a host DNS resolver to change VSAN fabric membership.
Explanation
Correct Answer
C:This directly addresses vSAN isolation for tenants because vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. Confirm the change against port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
Incorrect Answers
A:A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. The relevant correction is to place the relevant FC ports and zoning in the correct logically isolated VSAN.
B:Assign all SAN ports to a default VSAN to bypass isolation controls. The proposed change targets the wrong mechanism or lacks essential validation. VSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. Relevant evidence is port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
D:A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. The appropriate action remains to place the relevant FC ports and zoning in the correct logically isolated VSAN.
Question 692
A storage team places development and production initiators into one common VSAN and creates unintended shared name-service visibility. What should the engineer inspect to confirm the actual state?
- A storage vendor slogan without the relevant login and path counters.
- A green physical FC link light without fabric login, zoning or I/O evidence.
- A historical FC topology drawing with no current WWPN or port state.
- Port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
Explanation
Correct Answer
D:These observations test the actual vSAN isolation for tenants mechanism rather than a superficial management status. VSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services.
Incorrect Answers
A:This information cannot independently verify vSAN isolation for tenants. The decisive records instead include port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
B:This information cannot independently verify vSAN isolation for tenants. VSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services.
C:This information cannot independently verify vSAN isolation for tenants. In the given case, a storage team places development and production initiators into one common VSAN and creates unintended shared name-service visibility.
Question 693
A storage team places development and production initiators into one common VSAN and creates unintended shared name-service visibility. What technical behavior underlies the correct decision?
- VSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services.
- A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
- An unused VSAN number can replace an active zoning or port security rule.
- Every storage protocol provides the same file and block semantics.
Explanation
Correct Answer
A:Validation depends on port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access. This explains why the most appropriate response is to place the relevant FC ports and zoning in the correct logically isolated VSAN.
Incorrect Answers
B:A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for vSAN isolation for tenants. The applicable technical behavior is that vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. The operator should verify port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
C:An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for vSAN isolation for tenants. The applicable technical behavior is that vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. The operator should verify port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
D:Every storage protocol provides the same file and block semantics. This is an incorrect generalization for vSAN isolation for tenants. The applicable technical behavior is that vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. The operator should verify port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
Question 694
A storage team places development and production initiators into one common VSAN and creates unintended shared name-service visibility. Assume an engineer instead chooses to treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration. Which resulting risk or fault should the reviewer identify?
- Inspecting credit counters prevents FC frames from forwarding.
- A wrong VSAN can hide legitimate targets or mix unrelated administrative domains.
- A well-documented host multipath test is the source of the original fabric fault.
- Examining FCNS entries automatically removes the authorized zoning policy.
Explanation
Correct Answer
B:The proper corrective action is to place the relevant FC ports and zoning in the correct logically isolated VSAN. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual vSAN isolation for tenants defect after the shortcut. The meaningful failure is that a wrong VSAN can hide legitimate targets or mix unrelated administrative domains.
C:This does not explain the actual vSAN isolation for tenants defect after the shortcut. The relevant evidence is port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
D:This does not explain the actual vSAN isolation for tenants defect after the shortcut. Examining FCNS entries automatically removes the authorized zoning policy.
Question 695
A storage team places development and production initiators into one common VSAN and creates unintended shared name-service visibility. The observed failure is: a wrong VSAN can hide legitimate targets or mix unrelated administrative domains. Which remediation most directly restores the intended behavior?
- Assign all SAN ports to a default VSAN to bypass isolation controls.
- Edit a host DNS resolver to change VSAN fabric membership.
- Correct port and zone membership for the intended VSAN and test storage access.
- Treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration.
Explanation
Correct Answer
C:This addresses the observable fault while preserving a check of the expected result. VSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services.
Incorrect Answers
A:Assign all SAN ports to a default VSAN to bypass isolation controls. This would not reliably restore service after the stated fault. A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. The controlled recovery is to correct port and zone membership for the intended VSAN and test storage access.
B:Edit a host DNS resolver to change VSAN fabric membership. This would not reliably restore service after the stated fault. A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. The controlled recovery is to correct port and zone membership for the intended VSAN and test storage access.
D:Treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration. This would not reliably restore service after the stated fault. A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. The controlled recovery is to correct port and zone membership for the intended VSAN and test storage access.
Question 696
An MDS port move assigns a host to the wrong VSAN, so the host cannot see its intended production target. Which operator action best meets this technical requirement?
- On this affected device, the engineer should assign all SAN ports to a default VSAN to bypass isolation controls.
- On this affected device, the engineer should edit a host DNS resolver to change VSAN fabric membership.
- On this affected device, the engineer should treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration.
- On this affected device, the engineer should place the relevant FC ports and zoning in the correct logically isolated VSAN.
Explanation
Correct Answer
D:This directly addresses vSAN isolation for tenants because vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services.
Incorrect Answers
A:Assign all SAN ports to a default VSAN to bypass isolation controls. The proposed change targets the wrong mechanism or lacks essential validation. VSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. Relevant evidence is port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
B:A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. In the given case, an MDS port move assigns a host to the wrong VSAN, so the host cannot see its intended production target.
C:A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. Treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration.
Question 697
An MDS port move assigns a host to the wrong VSAN, so the host cannot see its intended production target. Which collection of observations most directly tests the suspected cause?
- For this deployment, examine port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
- For this deployment, examine an Ethernet ping that does not test the required SAN session or VSAN.
- For this deployment, examine a storage vendor slogan without the relevant login and path counters.
- For this deployment, examine a green physical FC link light without fabric login, zoning or I/O evidence.
Explanation
Correct Answer
A:These observations test the actual vSAN isolation for tenants mechanism rather than a superficial management status. They should be checked after place the relevant FC ports and zoning in the correct logically isolated VSAN.
Incorrect Answers
B:This information cannot independently verify vSAN isolation for tenants. An Ethernet ping that does not test the required SAN session or VSAN.
C:This information cannot independently verify vSAN isolation for tenants. A storage vendor slogan without the relevant login and path counters.
D:This information cannot independently verify vSAN isolation for tenants. A green physical FC link light without fabric login, zoning or I/O evidence.
Question 698
An MDS port move assigns a host to the wrong VSAN, so the host cannot see its intended production target. Which statement most accurately explains this scenario?
- For this condition, the applicable principle is that every storage protocol provides the same file and block semantics.
- For this condition, the applicable principle is that vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services.
- For this condition, the applicable principle is that a lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
- For this condition, the applicable principle is that wWPN zoning and IP access lists are interchangeable security primitives.
Explanation
Correct Answer
B:Validation depends on port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
Incorrect Answers
A:Every storage protocol provides the same file and block semantics. This is an incorrect generalization for vSAN isolation for tenants. The applicable technical behavior is that vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. The operator should verify port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
C:A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for vSAN isolation for tenants. The applicable technical behavior is that vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. The operator should verify port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
D:WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for vSAN isolation for tenants. The applicable technical behavior is that vSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services. The operator should verify port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
Question 699
An MDS port move assigns a host to the wrong VSAN, so the host cannot see its intended production target. Assume an engineer instead chooses to treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration. What is the principal technical consequence of the mistaken choice?
- The resulting defect is that examining FCNS entries automatically removes the authorized zoning policy.
- The resulting defect is that the SAN failed because operators retained correct WWPN identity records.
- The resulting defect is that a wrong VSAN can hide legitimate targets or mix unrelated administrative domains.
- The resulting defect is that a well-documented host multipath test is the source of the original fabric fault.
Explanation
Correct Answer
C:The proper corrective action is to place the relevant FC ports and zoning in the correct logically isolated VSAN. VSANs divide a physical Fibre Channel infrastructure into separate logical fabrics with independent services.
Incorrect Answers
A:This does not explain the actual vSAN isolation for tenants defect after the shortcut. In the given case, an MDS port move assigns a host to the wrong VSAN, so the host cannot see its intended production target.
B:This does not explain the actual vSAN isolation for tenants defect after the shortcut. The SAN failed because operators retained correct WWPN identity records.
D:This does not explain the actual vSAN isolation for tenants defect after the shortcut. A well-documented host multipath test is the source of the original fabric fault.
Question 700
An MDS port move assigns a host to the wrong VSAN, so the host cannot see its intended production target. The observed failure is: a wrong VSAN can hide legitimate targets or mix unrelated administrative domains. What should the engineer do to recover and validate the service?
- The controlled remediation is to edit a host DNS resolver to change VSAN fabric membership.
- The controlled remediation is to treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration.
- The controlled remediation is to assign all SAN ports to a default VSAN to bypass isolation controls.
- The controlled remediation is to correct port and zone membership for the intended VSAN and test storage access.
Explanation
Correct Answer
D:This addresses the observable fault while preserving a check of the expected result. Validate against port VSAN membership, active zoneset per VSAN, FCNS entries and host-to-target access.
Incorrect Answers
A:Edit a host DNS resolver to change VSAN fabric membership. This would not reliably restore service after the stated fault. A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. The controlled recovery is to correct port and zone membership for the intended VSAN and test storage access.
B:Treat an Ethernet VLAN ID as an automatic substitute for FC VSAN configuration. This would not reliably restore service after the stated fault. A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. The controlled recovery is to correct port and zone membership for the intended VSAN and test storage access.
C:Assign all SAN ports to a default VSAN to bypass isolation controls. This would not reliably restore service after the stated fault. A wrong VSAN can hide legitimate targets or mix unrelated administrative domains. The controlled recovery is to correct port and zone membership for the intended VSAN and test storage access.