cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 69

Question 680

A SAN change activates on one switch while peers still have an earlier enhanced zoning configuration due to pending CFS locks. The observed failure is: uncommitted or locked changes can leave switches in different effective policy states. What is the BEST controlled recovery once this failure is recognized?

  1. The controlled remediation is to assume a local text edit is already active fabric-wide.
  2. The controlled remediation is to make unrelated independent zoning changes on every switch while the CFS session is locked.
  3. The controlled remediation is to disable all VSANs to release a single pending commit.
  4. The controlled remediation is to resolve abandoned session or lock per procedure, commit intended changes, and verify consistency.

Explanation

Correct Answer

D:

Validate against cFS lock owner, pending zoning changes, commit state, and consistent distributed zone databases. Cisco Fabric Services supports coordinated distribution and commit of selected fabric-wide configuration such as enhanced zoning.

Incorrect Answers

A:

Assume a local text edit is already active fabric-wide. This would not reliably restore service after the stated fault. Uncommitted or locked changes can leave switches in different effective policy states. The controlled recovery is to resolve abandoned session or lock per procedure, commit intended changes, and verify consistency.

B:

Make unrelated independent zoning changes on every switch while the CFS session is locked. This would not reliably restore service after the stated fault. Uncommitted or locked changes can leave switches in different effective policy states. The controlled recovery is to resolve abandoned session or lock per procedure, commit intended changes, and verify consistency.

C:

Disable all VSANs to release a single pending commit. This would not reliably restore service after the stated fault. Uncommitted or locked changes can leave switches in different effective policy states. The controlled recovery is to resolve abandoned session or lock per procedure, commit intended changes, and verify consistency.

Question 681

Two MDS switches have several FC ISLs, but the physical links are configured inconsistently and do not form one port channel. What is the BEST supported implementation or corrective action?

  1. Align compatible FC ISL interface attributes and port-channel membership on both MDS peers.
  2. Use Ethernet LACP settings alone to establish an MDS FC port channel.
  3. Assign unrelated VSAN membership to each member in a nontrunked bundle.
  4. Disable all ISLs before checking interface compatibility.

Explanation

Correct Answer

A:

This directly addresses Fibre Channel ISL port channel because FC port channels aggregate compatible fabric inter-switch links into a logical connection. Confirm the change against FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

Incorrect Answers

B:

Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The relevant correction is to align compatible FC ISL interface attributes and port-channel membership on both MDS peers.

C:

Assign unrelated VSAN membership to each member in a nontrunked bundle. The proposed change targets the wrong mechanism or lacks essential validation. FC port channels aggregate compatible fabric inter-switch links into a logical connection. Relevant evidence is FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

D:

Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The appropriate action remains to align compatible FC ISL interface attributes and port-channel membership on both MDS peers.

Question 682

Two MDS switches have several FC ISLs, but the physical links are configured inconsistently and do not form one port channel. Which evidence BEST verifies the intended technical behavior?

  1. A copied zoneset name without its active effective members.
  2. FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.
  3. A historical FC topology drawing with no current WWPN or port state.
  4. An Ethernet ping that does not test the required SAN session or VSAN.

Explanation

Correct Answer

B:

These observations test the actual Fibre Channel ISL port channel mechanism rather than a superficial management status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

Incorrect Answers

A:

A copied zoneset name without its active effective members. This information cannot independently verify Fibre Channel ISL port channel. The decisive records instead include FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

C:

A historical FC topology drawing with no current WWPN or port state. This information cannot independently verify Fibre Channel ISL port channel. The decisive records instead include FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

D:

An Ethernet ping that does not test the required SAN session or VSAN. This information cannot independently verify Fibre Channel ISL port channel. The decisive records instead include FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

Question 683

Two MDS switches have several FC ISLs, but the physical links are configured inconsistently and do not form one port channel. Which principle BEST explains why the recommended solution is appropriate?

  1. An unused VSAN number can replace an active zoning or port security rule.
  2. WWPN zoning and IP access lists are interchangeable security primitives.
  3. FC port channels aggregate compatible fabric inter-switch links into a logical connection.
  4. Fibre Channel name service entries are identical to host multipath device state.

Explanation

Correct Answer

C:

Validation depends on FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. This explains why the most appropriate response is to align compatible FC ISL interface attributes and port-channel membership on both MDS peers.

Incorrect Answers

A:

An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for Fibre Channel ISL port channel. The applicable technical behavior is that FC port channels aggregate compatible fabric inter-switch links into a logical connection. The operator should verify FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

B:

WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for Fibre Channel ISL port channel. The applicable technical behavior is that FC port channels aggregate compatible fabric inter-switch links into a logical connection. The operator should verify FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

D:

Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for Fibre Channel ISL port channel. The applicable technical behavior is that FC port channels aggregate compatible fabric inter-switch links into a logical connection. The operator should verify FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

Question 684

Two MDS switches have several FC ISLs, but the physical links are configured inconsistently and do not form one port channel. Assume an engineer instead chooses to use Ethernet LACP settings alone to establish an MDS FC port channel. What is the MOST significant failure introduced by that shortcut?

  1. The SAN failed because operators retained correct WWPN identity records.
  2. The sole error was using a verified SAN maintenance window for a risky operation.
  3. Inspecting credit counters prevents FC frames from forwarding.
  4. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity.

Explanation

Correct Answer

D:

The proper corrective action is to align compatible FC ISL interface attributes and port-channel membership on both MDS peers. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

A:

This does not explain the actual Fibre Channel ISL port channel defect after the shortcut. The meaningful failure is that incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity.

B:

This does not explain the actual Fibre Channel ISL port channel defect after the shortcut. The relevant evidence is FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

C:

This does not explain the actual Fibre Channel ISL port channel defect after the shortcut. In the given case, two MDS switches have several FC ISLs, but the physical links are configured inconsistently and do not form one port channel.

Question 685

Two MDS switches have several FC ISLs, but the physical links are configured inconsistently and do not form one port channel. The observed failure is: incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. What is the BEST controlled recovery once this failure is recognized?

  1. Correct membership and common attributes, then verify all intended ISLs join the bundle.
  2. Assign unrelated VSAN membership to each member in a nontrunked bundle.
  3. Disable all ISLs before checking interface compatibility.
  4. Use Ethernet LACP settings alone to establish an MDS FC port channel.

Explanation

Correct Answer

A:

Validate against FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. This addresses the observable fault while preserving a check of the expected result.

Incorrect Answers

B:

Assign unrelated VSAN membership to each member in a nontrunked bundle. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.

C:

Disable all ISLs before checking interface compatibility. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.

D:

Use Ethernet LACP settings alone to establish an MDS FC port channel. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.

Question 686

A SAN maintenance window reveals only one ISL carrying traffic because the intended FC port-channel membership is suspended. Which configuration decision MOST directly resolves the issue?

  1. On this affected device, the engineer should assign unrelated VSAN membership to each member in a nontrunked bundle.
  2. On this affected device, the engineer should align compatible FC ISL interface attributes and port-channel membership on both MDS peers.
  3. On this affected device, the engineer should disable all ISLs before checking interface compatibility.
  4. On this affected device, the engineer should use Ethernet LACP settings alone to establish an MDS FC port channel.

Explanation

Correct Answer

B:

This directly addresses Fibre Channel ISL port channel because FC port channels aggregate compatible fabric inter-switch links into a logical connection.

Incorrect Answers

A:

Assign unrelated VSAN membership to each member in a nontrunked bundle. The proposed change targets the wrong mechanism or lacks essential validation. FC port channels aggregate compatible fabric inter-switch links into a logical connection. Relevant evidence is FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

C:

Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. In the given case, a SAN maintenance window reveals only one ISL carrying traffic because the intended FC port-channel membership is suspended.

D:

Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. Use Ethernet LACP settings alone to establish an MDS FC port channel.

Question 687

A SAN maintenance window reveals only one ISL carrying traffic because the intended FC port-channel membership is suspended. What should the engineer inspect to confirm the actual state?

  1. For this deployment, examine a storage vendor slogan without the relevant login and path counters.
  2. For this deployment, examine a copied zoneset name without its active effective members.
  3. For this deployment, examine FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.
  4. For this deployment, examine a historical FC topology drawing with no current WWPN or port state.

Explanation

Correct Answer

C:

These observations test the actual Fibre Channel ISL port channel mechanism rather than a superficial management status. They should be checked after align compatible FC ISL interface attributes and port-channel membership on both MDS peers.

Incorrect Answers

A:

A storage vendor slogan without the relevant login and path counters. This information cannot independently verify Fibre Channel ISL port channel. The decisive records instead include FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

B:

A copied zoneset name without its active effective members. This information cannot independently verify Fibre Channel ISL port channel. The decisive records instead include FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

D:

A historical FC topology drawing with no current WWPN or port state. This information cannot independently verify Fibre Channel ISL port channel. The decisive records instead include FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

Question 688

A SAN maintenance window reveals only one ISL carrying traffic because the intended FC port-channel membership is suspended. What technical behavior underlies the correct decision?

  1. For this condition, the applicable principle is that Fibre Channel name service entries are identical to host multipath device state.
  2. For this condition, the applicable principle is that an unused VSAN number can replace an active zoning or port security rule.
  3. For this condition, the applicable principle is that every storage protocol provides the same file and block semantics.
  4. For this condition, the applicable principle is that FC port channels aggregate compatible fabric inter-switch links into a logical connection.

Explanation

Correct Answer

D:

Validation depends on FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

Incorrect Answers

A:

Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for Fibre Channel ISL port channel. The applicable technical behavior is that FC port channels aggregate compatible fabric inter-switch links into a logical connection. The operator should verify FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

B:

An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for Fibre Channel ISL port channel. The applicable technical behavior is that FC port channels aggregate compatible fabric inter-switch links into a logical connection. The operator should verify FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

C:

Every storage protocol provides the same file and block semantics. This is an incorrect generalization for Fibre Channel ISL port channel. The applicable technical behavior is that FC port channels aggregate compatible fabric inter-switch links into a logical connection. The operator should verify FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status.

Question 689

A SAN maintenance window reveals only one ISL carrying traffic because the intended FC port-channel membership is suspended. Assume an engineer instead chooses to use Ethernet LACP settings alone to establish an MDS FC port channel. Which resulting risk or fault should the reviewer identify?

  1. The resulting defect is that incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity.
  2. The resulting defect is that inspecting credit counters prevents FC frames from forwarding.
  3. The resulting defect is that a well-documented host multipath test is the source of the original fabric fault.
  4. The resulting defect is that the sole error was using a verified SAN maintenance window for a risky operation.

Explanation

Correct Answer

A:

The proper corrective action is to align compatible FC ISL interface attributes and port-channel membership on both MDS peers. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

Incorrect Answers

B:

This does not explain the actual Fibre Channel ISL port channel defect after the shortcut. In the given case, a SAN maintenance window reveals only one ISL carrying traffic because the intended FC port-channel membership is suspended.

C:

This does not explain the actual Fibre Channel ISL port channel defect after the shortcut. A well-documented host multipath test is the source of the original fabric fault.

D:

This does not explain the actual Fibre Channel ISL port channel defect after the shortcut. The sole error was using a verified SAN maintenance window for a risky operation.

Question 690

A SAN maintenance window reveals only one ISL carrying traffic because the intended FC port-channel membership is suspended. The observed failure is: incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. Which remediation most directly restores the intended behavior?

  1. The controlled remediation is to disable all ISLs before checking interface compatibility.
  2. The controlled remediation is to correct membership and common attributes, then verify all intended ISLs join the bundle.
  3. The controlled remediation is to use Ethernet LACP settings alone to establish an MDS FC port channel.
  4. The controlled remediation is to assign unrelated VSAN membership to each member in a nontrunked bundle.

Explanation

Correct Answer

B:

Validate against FC port-channel members, VSAN and trunk settings, link speeds and bundle operational status. FC port channels aggregate compatible fabric inter-switch links into a logical connection.

Incorrect Answers

A:

Disable all ISLs before checking interface compatibility. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.

C:

Use Ethernet LACP settings alone to establish an MDS FC port channel. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.

D:

Assign unrelated VSAN membership to each member in a nontrunked bundle. This would not reliably restore service after the stated fault. Incompatible port settings prevent aggregation and can reduce SAN redundancy or capacity. The controlled recovery is to correct membership and common attributes, then verify all intended ISLs join the bundle.