cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 58

Question 570

A compute team wants to know which UCS hosts are affected by a failing adapter without physically inspecting every rack. The observed failure is: relying on stale manually maintained inventory may miss emerging component or firmware faults. Which remediation most directly restores the intended behavior?

  1. The controlled remediation is to disable management alerts to reduce visible inventory inconsistencies.
  2. The controlled remediation is to inspect fault details, remediate the affected component or policy, and verify fault clearance.
  3. The controlled remediation is to use only a network ping test as proof that all server hardware is healthy.
  4. The controlled remediation is to change service-profile descriptions to hide critical hardware faults.

Explanation

Correct Answer

B:

Validate against current hardware inventory, fault severity, affected chassis and server identifiers, and event timestamps. Intersight provides centralized UCS inventory and health visibility when devices are properly connected.

Incorrect Answers

A:

Disable management alerts to reduce visible inventory inconsistencies. This would not reliably restore service after the stated fault. Relying on stale manually maintained inventory may miss emerging component or firmware faults. The controlled recovery is to inspect fault details, remediate the affected component or policy, and verify fault clearance.

C:

Use only a network ping test as proof that all server hardware is healthy. This would not reliably restore service after the stated fault. Relying on stale manually maintained inventory may miss emerging component or firmware faults. The controlled recovery is to inspect fault details, remediate the affected component or policy, and verify fault clearance.

D:

Change service-profile descriptions to hide critical hardware faults. This would not reliably restore service after the stated fault. Relying on stale manually maintained inventory may miss emerging component or firmware faults. The controlled recovery is to inspect fault details, remediate the affected component or policy, and verify fault clearance.

Question 571

A dual-fabric UCS server has one virtual NIC for both fabrics but loses network connectivity when its primary FI is isolated. Which configuration decision MOST directly resolves the issue?

  1. Connect every logical NIC solely to one failed FI for simplicity.
  2. Assume a two-port adapter always means independent failure domains.
  3. Design supported vNIC fabric affinity and failover or OS teaming across independent FI paths.
  4. Disable one fabric permanently and label the server redundant.

Explanation

Correct Answer

C:

This directly addresses network adapter failover and fabric separation because UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. Confirm the change against vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

Incorrect Answers

A:

Connect every logical NIC solely to one failed FI for simplicity. This is not a valid substitute for the specified fix. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The relevant correction is to design supported vNIC fabric affinity and failover or OS teaming across independent FI paths.

B:

Assume a two-port adapter always means independent failure domains. The proposed change targets the wrong mechanism or lacks essential validation. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. Relevant evidence is vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

D:

Disable one fabric permanently and label the server redundant. This would leave the diagnosed requirement unresolved. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The appropriate action remains to design supported vNIC fabric affinity and failover or OS teaming across independent FI paths.

Question 572

A dual-fabric UCS server has one virtual NIC for both fabrics but loses network connectivity when its primary FI is isolated. What should the engineer inspect to confirm the actual state?

  1. The rack label without current UCS or Intersight policy associations.
  2. A management ping that does not verify the required server or adapter function.
  3. An operator assurance without current logs, component inventory or health faults.
  4. vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

Explanation

Correct Answer

D:

These observations test the actual network adapter failover and fabric separation mechanism rather than a superficial management status. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

Incorrect Answers

A:

The rack label without current UCS or Intersight policy associations. This information cannot independently verify network adapter failover and fabric separation. The decisive records instead include vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

B:

A management ping that does not verify the required server or adapter function. This information cannot independently verify network adapter failover and fabric separation. The decisive records instead include vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

C:

An operator assurance without current logs, component inventory or health faults. This information cannot independently verify network adapter failover and fabric separation. The decisive records instead include vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

Question 573

A dual-fabric UCS server has one virtual NIC for both fabrics but loses network connectivity when its primary FI is isolated. What technical behavior underlies the correct decision?

  1. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.
  2. Service profiles can never change effective network identity or firmware behavior.
  3. Two logical objects always provide resilience even if they share one failed hardware path.
  4. A rack server that powers on is automatically configured for every SAN and LAN service.

Explanation

Correct Answer

A:

Validation depends on vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. This explains why the most appropriate response is to design supported vNIC fabric affinity and failover or OS teaming across independent FI paths.

Incorrect Answers

B:

Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for network adapter failover and fabric separation. The applicable technical behavior is that UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. The operator should verify vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

C:

Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for network adapter failover and fabric separation. The applicable technical behavior is that UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. The operator should verify vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

D:

A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for network adapter failover and fabric separation. The applicable technical behavior is that UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. The operator should verify vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

Question 574

A dual-fabric UCS server has one virtual NIC for both fabrics but loses network connectivity when its primary FI is isolated. Assume an engineer instead chooses to connect every logical NIC solely to one failed FI for simplicity. Which resulting risk or fault should the reviewer identify?

  1. Recording chassis health events is what prevents server management.
  2. A common fabric dependency defeats the intended resilience despite having multiple NIC objects.
  3. Checking effective service-profile bindings caused the original hardware mismatch.
  4. The underlying fault was caused only by retaining accurate firmware inventory.

Explanation

Correct Answer

B:

The proper corrective action is to design supported vNIC fabric affinity and failover or OS teaming across independent FI paths. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

A:

This does not explain the actual network adapter failover and fabric separation defect after the shortcut. The meaningful failure is that a common fabric dependency defeats the intended resilience despite having multiple NIC objects.

C:

This does not explain the actual network adapter failover and fabric separation defect after the shortcut. The relevant evidence is vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

D:

This does not explain the actual network adapter failover and fabric separation defect after the shortcut. The underlying fault was caused only by retaining accurate firmware inventory.

Question 575

A dual-fabric UCS server has one virtual NIC for both fabrics but loses network connectivity when its primary FI is isolated. The observed failure is: a common fabric dependency defeats the intended resilience despite having multiple NIC objects. Which remediation most directly restores the intended behavior?

  1. Assume a two-port adapter always means independent failure domains.
  2. Disable one fabric permanently and label the server redundant.
  3. Correct redundant path policy and validate the host's traffic during a simulated fabric failure.
  4. Connect every logical NIC solely to one failed FI for simplicity.

Explanation

Correct Answer

C:

Validate against vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. This addresses the observable fault while preserving a check of the expected result.

Incorrect Answers

A:

Assume a two-port adapter always means independent failure domains. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

B:

Disable one fabric permanently and label the server redundant. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

D:

Connect every logical NIC solely to one failed FI for simplicity. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

Question 576

An operator binds both high-availability paths to a single UCS fabric and expects redundant switching to protect the host. Which operator action best meets this technical requirement?

  1. On this affected device, the engineer should assume a two-port adapter always means independent failure domains.
  2. On this affected device, the engineer should disable one fabric permanently and label the server redundant.
  3. On this affected device, the engineer should connect every logical NIC solely to one failed FI for simplicity.
  4. On this affected device, the engineer should design supported vNIC fabric affinity and failover or OS teaming across independent FI paths.

Explanation

Correct Answer

D:

This directly addresses network adapter failover and fabric separation because UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

Incorrect Answers

A:

Assume a two-port adapter always means independent failure domains. The proposed change targets the wrong mechanism or lacks essential validation. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. Relevant evidence is vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

B:

Disable one fabric permanently and label the server redundant. This would leave the diagnosed requirement unresolved. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The appropriate action remains to design supported vNIC fabric affinity and failover or OS teaming across independent FI paths.

C:

Connect every logical NIC solely to one failed FI for simplicity. This is not a valid substitute for the specified fix. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The relevant correction is to design supported vNIC fabric affinity and failover or OS teaming across independent FI paths.

Question 577

An operator binds both high-availability paths to a single UCS fabric and expects redundant switching to protect the host. Which collection of observations most directly tests the suspected cause?

  1. For this deployment, examine vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.
  2. For this deployment, examine the planned service profile template without checking effective deployed settings.
  3. For this deployment, examine the rack label without current UCS or Intersight policy associations.
  4. For this deployment, examine a management ping that does not verify the required server or adapter function.

Explanation

Correct Answer

A:

These observations test the actual network adapter failover and fabric separation mechanism rather than a superficial management status. They should be checked after design supported vNIC fabric affinity and failover or OS teaming across independent FI paths.

Incorrect Answers

B:

The planned service profile template without checking effective deployed settings. This information cannot independently verify network adapter failover and fabric separation. The decisive records instead include vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

C:

The rack label without current UCS or Intersight policy associations. This information cannot independently verify network adapter failover and fabric separation. The decisive records instead include vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

D:

A management ping that does not verify the required server or adapter function. This information cannot independently verify network adapter failover and fabric separation. The decisive records instead include vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

Question 578

An operator binds both high-availability paths to a single UCS fabric and expects redundant switching to protect the host. Which statement most accurately explains this scenario?

  1. For this condition, the applicable principle is that a rack server that powers on is automatically configured for every SAN and LAN service.
  2. For this condition, the applicable principle is that UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.
  3. For this condition, the applicable principle is that service profiles can never change effective network identity or firmware behavior.
  4. For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.

Explanation

Correct Answer

B:

Validation depends on vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

Incorrect Answers

A:

A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for network adapter failover and fabric separation. The applicable technical behavior is that UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. The operator should verify vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

C:

Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for network adapter failover and fabric separation. The applicable technical behavior is that UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. The operator should verify vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

D:

All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for network adapter failover and fabric separation. The applicable technical behavior is that UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior. The operator should verify vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test.

Question 579

An operator binds both high-availability paths to a single UCS fabric and expects redundant switching to protect the host. Assume an engineer instead chooses to connect every logical NIC solely to one failed FI for simplicity. What is the principal technical consequence of the mistaken choice?

  1. The resulting defect is that the underlying fault was caused only by retaining accurate firmware inventory.
  2. The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.
  3. The resulting defect is that a common fabric dependency defeats the intended resilience despite having multiple NIC objects.
  4. The resulting defect is that checking effective service-profile bindings caused the original hardware mismatch.

Explanation

Correct Answer

C:

The proper corrective action is to design supported vNIC fabric affinity and failover or OS teaming across independent FI paths. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

Incorrect Answers

A:

This does not explain the actual network adapter failover and fabric separation defect after the shortcut. In the given case, an operator binds both high-availability paths to a single UCS fabric and expects redundant switching to protect the host.

B:

This does not explain the actual network adapter failover and fabric separation defect after the shortcut. A controlled failover test itself proves that the previous outage had no cause.

D:

This does not explain the actual network adapter failover and fabric separation defect after the shortcut. Checking effective service-profile bindings caused the original hardware mismatch.

Question 580

An operator binds both high-availability paths to a single UCS fabric and expects redundant switching to protect the host. The observed failure is: a common fabric dependency defeats the intended resilience despite having multiple NIC objects. What should the engineer do to recover and validate the service?

  1. The controlled remediation is to disable one fabric permanently and label the server redundant.
  2. The controlled remediation is to connect every logical NIC solely to one failed FI for simplicity.
  3. The controlled remediation is to assume a two-port adapter always means independent failure domains.
  4. The controlled remediation is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

Explanation

Correct Answer

D:

Validate against vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

Incorrect Answers

A:

Disable one fabric permanently and label the server redundant. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

B:

Connect every logical NIC solely to one failed FI for simplicity. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

C:

Assume a two-port adapter always means independent failure domains. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests