cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 59

Question 580

An operator binds both high-availability paths to a single UCS fabric and expects redundant switching to protect the host. The observed failure is: a common fabric dependency defeats the intended resilience despite having multiple NIC objects. What should the engineer do to recover and validate the service?

  1. The controlled remediation is to disable one fabric permanently and label the server redundant.
  2. The controlled remediation is to connect every logical NIC solely to one failed FI for simplicity.
  3. The controlled remediation is to assume a two-port adapter always means independent failure domains.
  4. The controlled remediation is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

Explanation

Correct Answer

D:

Validate against vNIC fabric assignments, failure-domain topology, host NIC team status and controlled FI failover test. UCS redundancy relies on deliberate independent fabric connectivity and supported host failover behavior.

Incorrect Answers

A:

Disable one fabric permanently and label the server redundant. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

B:

Connect every logical NIC solely to one failed FI for simplicity. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

C:

Assume a two-port adapter always means independent failure domains. This would not reliably restore service after the stated fault. A common fabric dependency defeats the intended resilience despite having multiple NIC objects. The controlled recovery is to correct redundant path policy and validate the host's traffic during a simulated fabric failure.

Question 581

A blade vHBA is logged into the FI but does not reach its target because no eligible SAN uplink exists on that fabric. Which operator action best meets this technical requirement?

  1. Restore supported SAN uplink connectivity and vHBA fabric association for the correct VSAN.
  2. Assign an Internet VLAN as the Fibre Channel SAN uplink.
  3. Change the hypervisor hostname to produce an FC fabric path.
  4. Move both vHBAs into one broken fabric to test redundancy.

Explanation

Correct Answer

A:

This directly addresses Fibre Channel uplink SAN pinning because UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain. Confirm the change against fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

Incorrect Answers

B:

Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. The relevant correction is to restore supported SAN uplink connectivity and vHBA fabric association for the correct VSAN.

C:

That option would change the hypervisor hostname to produce an FC fabric path, but it addresses a different concern. This directly addresses Fibre Channel uplink SAN pinning because UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

D:

Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. The appropriate action remains to restore supported SAN uplink connectivity and vHBA fabric association for the correct VSAN.

Question 582

A blade vHBA is logged into the FI but does not reach its target because no eligible SAN uplink exists on that fabric. Which collection of observations most directly tests the suspected cause?

  1. The planned service profile template without checking effective deployed settings.
  2. FI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.
  3. An old inventory export that omits the current chassis and firmware state.
  4. A management ping that does not verify the required server or adapter function.

Explanation

Correct Answer

B:

These observations test the actual Fibre Channel uplink SAN pinning mechanism rather than a superficial management status. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

Incorrect Answers

A:

The planned service profile template without checking effective deployed settings. This information cannot independently verify Fibre Channel uplink SAN pinning. The decisive records instead include fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

C:

An old inventory export that omits the current chassis and firmware state. This information cannot independently verify Fibre Channel uplink SAN pinning. The decisive records instead include fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

D:

A management ping that does not verify the required server or adapter function. This information cannot independently verify Fibre Channel uplink SAN pinning. The decisive records instead include fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

Question 583

A blade vHBA is logged into the FI but does not reach its target because no eligible SAN uplink exists on that fabric. Which statement most accurately explains this scenario?

  1. Out-of-band management reachability guarantees that all host interfaces operate correctly.
  2. Service profiles can never change effective network identity or firmware behavior.
  3. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.
  4. All UCS configuration edits take effect without maintenance, validation or dependencies.

Explanation

Correct Answer

C:

Validation depends on fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. This explains why the most appropriate response is to restore supported SAN uplink connectivity and vHBA fabric association for the correct VSAN.

Incorrect Answers

A:

Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for Fibre Channel uplink SAN pinning. The applicable technical behavior is that UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain. The operator should verify fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

B:

Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for Fibre Channel uplink SAN pinning. The applicable technical behavior is that UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain. The operator should verify fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

D:

All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for Fibre Channel uplink SAN pinning. The applicable technical behavior is that UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain. The operator should verify fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

Question 584

A blade vHBA is logged into the FI but does not reach its target because no eligible SAN uplink exists on that fabric. Assume an engineer instead chooses to assign an Internet VLAN as the Fibre Channel SAN uplink. What is the principal technical consequence of the mistaken choice?

  1. The underlying fault was caused only by retaining accurate firmware inventory.
  2. A controlled failover test itself proves that the previous outage had no cause.
  3. The only failure is that the administrator preserved a known-good backup.
  4. Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path.

Explanation

Correct Answer

D:

The proper corrective action is to restore supported SAN uplink connectivity and vHBA fabric association for the correct VSAN. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

Incorrect Answers

A:

This does not explain the actual Fibre Channel uplink SAN pinning defect after the shortcut. The meaningful failure is that healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path.

B:

This does not explain the actual Fibre Channel uplink SAN pinning defect after the shortcut. The relevant evidence is fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

C:

This does not explain the actual Fibre Channel uplink SAN pinning defect after the shortcut. The only failure is that the administrator preserved a known-good backup.

Question 585

A blade vHBA is logged into the FI but does not reach its target because no eligible SAN uplink exists on that fabric. The observed failure is: healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. What should the engineer do to recover and validate the service?

  1. Repair SAN uplink and pinning state and verify HBA and target logins through the right fabric.
  2. Change the hypervisor hostname to produce an FC fabric path.
  3. Move both vHBAs into one broken fabric to test redundancy.
  4. Assign an Internet VLAN as the Fibre Channel SAN uplink.

Explanation

Correct Answer

A:

Validate against fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. This addresses the observable fault while preserving a check of the expected result.

Incorrect Answers

B:

That option would change the hypervisor hostname to produce an FC fabric path, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.

C:

Move both vHBAs into one broken fabric to test redundancy. This would not reliably restore service after the stated fault. Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. The controlled recovery is to repair SAN uplink and pinning state and verify HBA and target logins through the right fabric.

D:

That option would assign an Internet VLAN as the Fibre Channel SAN uplink, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.

Question 586

A UCS service profile can see local vHBA inventory but SAN sessions fail after the FI's pinned FC uplink goes down. Which next step should the data center engineer select?

  1. On this affected device, the engineer should change the hypervisor hostname to produce an FC fabric path.
  2. On this affected device, the engineer should restore supported SAN uplink connectivity and vHBA fabric association for the correct VSAN.
  3. On this affected device, the engineer should move both vHBAs into one broken fabric to test redundancy.
  4. On this affected device, the engineer should assign an Internet VLAN as the Fibre Channel SAN uplink.

Explanation

Correct Answer

B:

This directly addresses Fibre Channel uplink SAN pinning because UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

Incorrect Answers

A:

Change the hypervisor hostname to produce an FC fabric path. The proposed change targets the wrong mechanism or lacks essential validation. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain. Relevant evidence is fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

C:

Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path.

D:

Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. Assign an Internet VLAN as the Fibre Channel SAN uplink.

Question 587

A UCS service profile can see local vHBA inventory but SAN sessions fail after the FI's pinned FC uplink goes down. Which diagnostic record would most strongly confirm the result?

  1. For this deployment, examine an operator assurance without current logs, component inventory or health faults.
  2. For this deployment, examine the planned service profile template without checking effective deployed settings.
  3. For this deployment, examine fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.
  4. For this deployment, examine an old inventory export that omits the current chassis and firmware state.

Explanation

Correct Answer

C:

These observations test the actual Fibre Channel uplink SAN pinning mechanism rather than a superficial management status. They should be checked after restore supported SAN uplink connectivity and vHBA fabric association for the correct VSAN.

Incorrect Answers

A:

An operator assurance without current logs, component inventory or health faults. This information cannot independently verify Fibre Channel uplink SAN pinning. The decisive records instead include fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

B:

The planned service profile template without checking effective deployed settings. This information cannot independently verify Fibre Channel uplink SAN pinning. The decisive records instead include fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

D:

An old inventory export that omits the current chassis and firmware state. This information cannot independently verify Fibre Channel uplink SAN pinning. The decisive records instead include fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

Question 588

A UCS service profile can see local vHBA inventory but SAN sessions fail after the FI's pinned FC uplink goes down. Which platform concept should guide the engineer’s assessment?

  1. For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.
  2. For this condition, the applicable principle is that out-of-band management reachability guarantees that all host interfaces operate correctly.
  3. For this condition, the applicable principle is that two logical objects always provide resilience even if they share one failed hardware path.
  4. For this condition, the applicable principle is that UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

Explanation

Correct Answer

D:

Validation depends on fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

Incorrect Answers

A:

All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for Fibre Channel uplink SAN pinning. The applicable technical behavior is that UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain. The operator should verify fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

B:

Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for Fibre Channel uplink SAN pinning. The applicable technical behavior is that UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain. The operator should verify fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

C:

Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for Fibre Channel uplink SAN pinning. The applicable technical behavior is that UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain. The operator should verify fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records.

Question 589

A UCS service profile can see local vHBA inventory but SAN sessions fail after the FI's pinned FC uplink goes down. Assume an engineer instead chooses to assign an Internet VLAN as the Fibre Channel SAN uplink. Which root-cause observation follows from that incorrect change?

  1. The resulting defect is that healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path.
  2. The resulting defect is that the only failure is that the administrator preserved a known-good backup.
  3. The resulting defect is that recording chassis health events is what prevents server management.
  4. The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.

Explanation

Correct Answer

A:

The proper corrective action is to restore supported SAN uplink connectivity and vHBA fabric association for the correct VSAN. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

B:

This does not explain the actual Fibre Channel uplink SAN pinning defect after the shortcut. In the given case, a UCS service profile can see local vHBA inventory but SAN sessions fail after the FI's pinned FC uplink goes down.

C:

This does not explain the actual Fibre Channel uplink SAN pinning defect after the shortcut. Recording chassis health events is what prevents server management.

D:

This does not explain the actual Fibre Channel uplink SAN pinning defect after the shortcut. A controlled failover test itself proves that the previous outage had no cause.

Question 590

A UCS service profile can see local vHBA inventory but SAN sessions fail after the FI's pinned FC uplink goes down. The observed failure is: healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. Which recovery action addresses the underlying technical fault?

  1. The controlled remediation is to move both vHBAs into one broken fabric to test redundancy.
  2. The controlled remediation is to repair SAN uplink and pinning state and verify HBA and target logins through the right fabric.
  3. The controlled remediation is to assign an Internet VLAN as the Fibre Channel SAN uplink.
  4. The controlled remediation is to change the hypervisor hostname to produce an FC fabric path.

Explanation

Correct Answer

B:

Validate against fI FC uplink status, vHBA pinning, NPV login state, VSAN membership and fabric name-server records. UCS vHBA SAN traffic requires an operational FI-to-fabric path in the correct SAN domain.

Incorrect Answers

A:

Move both vHBAs into one broken fabric to test redundancy. This would not reliably restore service after the stated fault. Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. The controlled recovery is to repair SAN uplink and pinning state and verify HBA and target logins through the right fabric.

C:

Assign an Internet VLAN as the Fibre Channel SAN uplink. This would not reliably restore service after the stated fault. Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. The controlled recovery is to repair SAN uplink and pinning state and verify HBA and target logins through the right fabric.

D:

Change the hypervisor hostname to produce an FC fabric path. This would not reliably restore service after the stated fault. Healthy virtual HBA configuration cannot replace a missing physical fabric or uplink forwarding path. The controlled recovery is to repair SAN uplink and pinning state and verify HBA and target logins through the right fabric.

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests