Cisco 350-601 Practice Test 56
Question 550
A restoration procedure fails because the backed-up version and target UCS firmware are incompatible. The observed failure is: a stale or incompatible backup can fail at the moment it is needed despite existing on disk. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to import a backup onto any unrelated domain without validating target compatibility.
- The controlled remediation is to use an appropriate compatible backup and rehearse or safely test the restore path.
- The controlled remediation is to assume that the presence of a filename proves a successful restore.
- The controlled remediation is to discard change history to make restore testing faster.
Explanation
Correct Answer
B:This addresses the observable fault while preserving a check of the expected result. Validate against backup checksums, firmware release compatibility, recovery runbook and staged restore results.
Incorrect Answers
A:Import a backup onto any unrelated domain without validating target compatibility. This would not reliably restore service after the stated fault. A stale or incompatible backup can fail at the moment it is needed despite existing on disk. The controlled recovery is to use an appropriate compatible backup and rehearse or safely test the restore path.
C:Assume that the presence of a filename proves a successful restore. This would not reliably restore service after the stated fault. A stale or incompatible backup can fail at the moment it is needed despite existing on disk. The controlled recovery is to use an appropriate compatible backup and rehearse or safely test the restore path.
D:Discard change history to make restore testing faster. This would not reliably restore service after the stated fault. A stale or incompatible backup can fail at the moment it is needed despite existing on disk. The controlled recovery is to use an appropriate compatible backup and rehearse or safely test the restore path.
Question 551
An investigator needs packet copies from a specific UCS virtual NIC, but configures SPAN on an unrelated uplink. Which next step should the data center engineer select?
- Assume an SNMP interface-up signal contains full packet payloads.
- Mirror only CIMC login traffic to diagnose workload TCP loss.
- Map the intended UCS vNIC or Ethernet traffic source to an appropriate SPAN destination and capture scope.
- Disable the target vNIC to force packets into the SPAN destination.
Explanation
Correct Answer
C:This directly addresses UCS traffic SPAN source because sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. Confirm the change against sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
Incorrect Answers
A:Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. The relevant correction is to map the intended UCS vNIC or Ethernet traffic source to an appropriate SPAN destination and capture scope.
B:Mirror only CIMC login traffic to diagnose workload TCP loss. The proposed change targets the wrong mechanism or lacks essential validation. SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. Relevant evidence is sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
D:Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. The appropriate action remains to map the intended UCS vNIC or Ethernet traffic source to an appropriate SPAN destination and capture scope.
Question 552
An investigator needs packet copies from a specific UCS virtual NIC, but configures SPAN on an unrelated uplink. Which diagnostic record would most strongly confirm the result?
- A management ping that does not verify the required server or adapter function.
- The planned service profile template without checking effective deployed settings.
- The rack label without current UCS or Intersight policy associations.
- SPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
Explanation
Correct Answer
D:These observations test the actual UCS traffic SPAN source mechanism rather than a superficial management status. SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible.
Incorrect Answers
A:This information cannot independently verify UCS traffic SPAN source. The decisive records instead include sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
B:This information cannot independently verify UCS traffic SPAN source. SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible.
C:This information cannot independently verify UCS traffic SPAN source. The rack label without current UCS or Intersight policy associations.
Question 553
An investigator needs packet copies from a specific UCS virtual NIC, but configures SPAN on an unrelated uplink. Which platform concept should guide the engineer’s assessment?
- SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible.
- All UCS configuration edits take effect without maintenance, validation or dependencies.
- A rack server that powers on is automatically configured for every SAN and LAN service.
- Service profiles can never change effective network identity or firmware behavior.
Explanation
Correct Answer
A:Validation depends on sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps. This explains why the most appropriate response is to map the intended UCS vNIC or Ethernet traffic source to an appropriate SPAN destination and capture scope.
Incorrect Answers
B:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for UCS traffic SPAN source. The applicable technical behavior is that sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. The operator should verify sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
C:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for UCS traffic SPAN source. The applicable technical behavior is that sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. The operator should verify sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
D:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for UCS traffic SPAN source. The applicable technical behavior is that sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. The operator should verify sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
Question 554
An investigator needs packet copies from a specific UCS virtual NIC, but configures SPAN on an unrelated uplink. Assume an engineer instead chooses to assume an SNMP interface-up signal contains full packet payloads. Which root-cause observation follows from that incorrect change?
- Checking effective service-profile bindings caused the original hardware mismatch.
- Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved.
- The underlying fault was caused only by retaining accurate firmware inventory.
- A controlled failover test itself proves that the previous outage had no cause.
Explanation
Correct Answer
B:SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual UCS traffic SPAN source defect after the shortcut. The meaningful failure is that mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved.
C:This does not explain the actual UCS traffic SPAN source defect after the shortcut. The relevant evidence is sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
D:This does not explain the actual UCS traffic SPAN source defect after the shortcut. In the given case, an investigator needs packet copies from a specific UCS virtual NIC, but configures SPAN on an unrelated uplink.
Question 555
An investigator needs packet copies from a specific UCS virtual NIC, but configures SPAN on an unrelated uplink. The observed failure is: mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. Which recovery action addresses the underlying technical fault?
- Mirror only CIMC login traffic to diagnose workload TCP loss.
- Disable the target vNIC to force packets into the SPAN destination.
- Correct the mirrored source and validate packet visibility while avoiding capture saturation.
- Assume an SNMP interface-up signal contains full packet payloads.
Explanation
Correct Answer
C:SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
A:Mirror only CIMC login traffic to diagnose workload TCP loss. This would not reliably restore service after the stated fault. Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. The controlled recovery is to correct the mirrored source and validate packet visibility while avoiding capture saturation.
B:Disable the target vNIC to force packets into the SPAN destination. This would not reliably restore service after the stated fault. Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. The controlled recovery is to correct the mirrored source and validate packet visibility while avoiding capture saturation.
D:Assume an SNMP interface-up signal contains full packet payloads. This would not reliably restore service after the stated fault. Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. The controlled recovery is to correct the mirrored source and validate packet visibility while avoiding capture saturation.
Question 556
A hypervisor team reports east-west packet loss and the UCS capture destination receives traffic from the wrong vNIC. What is the BEST supported implementation or corrective action?
- On this affected device, the engineer should mirror only CIMC login traffic to diagnose workload TCP loss.
- On this affected device, the engineer should disable the target vNIC to force packets into the SPAN destination.
- On this affected device, the engineer should assume an SNMP interface-up signal contains full packet payloads.
- On this affected device, the engineer should map the intended UCS vNIC or Ethernet traffic source to an appropriate SPAN destination and capture scope.
Explanation
Correct Answer
D:This directly addresses UCS traffic SPAN source because sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible.
Incorrect Answers
A:Mirror only CIMC login traffic to diagnose workload TCP loss. The proposed change targets the wrong mechanism or lacks essential validation. SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. Relevant evidence is sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
B:Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. Disable the target vNIC to force packets into the SPAN destination.
C:Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. Assume an SNMP interface-up signal contains full packet payloads.
Question 557
A hypervisor team reports east-west packet loss and the UCS capture destination receives traffic from the wrong vNIC. Which evidence BEST verifies the intended technical behavior?
- For this deployment, examine sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
- For this deployment, examine an old inventory export that omits the current chassis and firmware state.
- For this deployment, examine a management ping that does not verify the required server or adapter function.
- For this deployment, examine the planned service profile template without checking effective deployed settings.
Explanation
Correct Answer
A:These observations test the actual UCS traffic SPAN source mechanism rather than a superficial management status. They should be checked after map the intended UCS vNIC or Ethernet traffic source to an appropriate SPAN destination and capture scope.
Incorrect Answers
B:This information cannot independently verify UCS traffic SPAN source. An old inventory export that omits the current chassis and firmware state.
C:This information cannot independently verify UCS traffic SPAN source. A management ping that does not verify the required server or adapter function.
D:This information cannot independently verify UCS traffic SPAN source. The planned service profile template without checking effective deployed settings.
Question 558
A hypervisor team reports east-west packet loss and the UCS capture destination receives traffic from the wrong vNIC. Which principle BEST explains why the recommended solution is appropriate?
- For this condition, the applicable principle is that service profiles can never change effective network identity or firmware behavior.
- For this condition, the applicable principle is that sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible.
- For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.
- For this condition, the applicable principle is that out-of-band management reachability guarantees that all host interfaces operate correctly.
Explanation
Correct Answer
B:Validation depends on sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps. SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible.
Incorrect Answers
A:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for UCS traffic SPAN source. The applicable technical behavior is that sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. The operator should verify sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
C:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for UCS traffic SPAN source. The applicable technical behavior is that sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. The operator should verify sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
D:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for UCS traffic SPAN source. The applicable technical behavior is that sPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. The operator should verify sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
Question 559
A hypervisor team reports east-west packet loss and the UCS capture destination receives traffic from the wrong vNIC. Assume an engineer instead chooses to assume an SNMP interface-up signal contains full packet payloads. What is the MOST significant failure introduced by that shortcut?
- The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.
- The resulting defect is that the only failure is that the administrator preserved a known-good backup.
- The resulting defect is that mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved.
- The resulting defect is that the underlying fault was caused only by retaining accurate firmware inventory.
Explanation
Correct Answer
C:SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. The proper corrective action is to map the intended UCS vNIC or Ethernet traffic source to an appropriate SPAN destination and capture scope.
Incorrect Answers
A:This does not explain the actual UCS traffic SPAN source defect after the shortcut. A controlled failover test itself proves that the previous outage had no cause.
B:This does not explain the actual UCS traffic SPAN source defect after the shortcut. The only failure is that the administrator preserved a known-good backup.
D:This does not explain the actual UCS traffic SPAN source defect after the shortcut. The underlying fault was caused only by retaining accurate firmware inventory.
Question 560
A hypervisor team reports east-west packet loss and the UCS capture destination receives traffic from the wrong vNIC. The observed failure is: mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. What is the BEST controlled recovery once this failure is recognized?
- The controlled remediation is to disable the target vNIC to force packets into the SPAN destination.
- The controlled remediation is to assume an SNMP interface-up signal contains full packet payloads.
- The controlled remediation is to mirror only CIMC login traffic to diagnose workload TCP loss.
- The controlled remediation is to correct the mirrored source and validate packet visibility while avoiding capture saturation.
Explanation
Correct Answer
D:SPAN effectiveness depends on choosing the traffic point where the frames of interest are visible. Validate against sPAN source and destination assignment, actual mirrored packets, observed host path and capture timestamps.
Incorrect Answers
A:Disable the target vNIC to force packets into the SPAN destination. This would not reliably restore service after the stated fault. Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. The controlled recovery is to correct the mirrored source and validate packet visibility while avoiding capture saturation.
B:Assume an SNMP interface-up signal contains full packet payloads. This would not reliably restore service after the stated fault. Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. The controlled recovery is to correct the mirrored source and validate packet visibility while avoiding capture saturation.
C:Mirror only CIMC login traffic to diagnose workload TCP loss. This would not reliably restore service after the stated fault. Mirroring the wrong fabric path can produce a clean capture while the affected flows remain unobserved. The controlled recovery is to correct the mirrored source and validate packet visibility while avoiding capture saturation.