Cisco 350-601 Practice Test 44
Question 430
A service profile was moved to replacement hardware and the SAN boot policy still references an obsolete target WWPN. The observed failure is: working FC links do not guarantee a bootable target if the configured target or LUN is wrong. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to remove both boot targets and rely on automatic discovery.
- The controlled remediation is to repair boot policy and storage presentation, then test the primary and backup fabric boot paths.
- The controlled remediation is to set the FI management gateway to the LUN identifier.
- The controlled remediation is to use only a VMware guest setting to replace host firmware SAN targets.
Explanation
Correct Answer
B:Validate against UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
Incorrect Answers
A:Remove both boot targets and rely on automatic discovery. This would not reliably restore service after the stated fault. Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. The controlled recovery is to repair boot policy and storage presentation, then test the primary and backup fabric boot paths.
C:Set the FI management gateway to the LUN identifier. This would not reliably restore service after the stated fault. Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. The controlled recovery is to repair boot policy and storage presentation, then test the primary and backup fabric boot paths.
D:Use only a VMware guest setting to replace host firmware SAN targets. This would not reliably restore service after the stated fault. Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. The controlled recovery is to repair boot policy and storage presentation, then test the primary and backup fabric boot paths.
Question 431
A UCS blade hardware replacement should preserve its server identity and connectivity policies but the team manually rebuilds configuration on the chassis. Which next step should the data center engineer select?
- Copy raw chassis serial numbers as the exclusive server networking policy.
- Use a switchport description to substitute for all UCS service profile settings.
- Apply a reusable UCS service profile or template with centrally governed identity and connectivity policies.
- Create new random WWPNs for every failover event without revising zoning.
Explanation
Correct Answer
C:This directly addresses service profile abstraction because UCS service profiles abstract server identity and policy from a particular physical compute device. Confirm the change against associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
Incorrect Answers
A:Configuring each replacement server independently increases drift and can break storage and network identities. The relevant correction is to apply a reusable UCS service profile or template with centrally governed identity and connectivity policies.
B:That option would use a switchport description to substitute for all UCS service profile settings, but it addresses a different concern. This directly addresses service profile abstraction because UCS service profiles abstract server identity and policy from a particular physical compute device.
D:Configuring each replacement server independently increases drift and can break storage and network identities. The appropriate action remains to apply a reusable UCS service profile or template with centrally governed identity and connectivity policies.
Question 432
A UCS blade hardware replacement should preserve its server identity and connectivity policies but the team manually rebuilds configuration on the chassis. Which diagnostic record would most strongly confirm the result?
- The planned service profile template without checking effective deployed settings.
- An old inventory export that omits the current chassis and firmware state.
- A management ping that does not verify the required server or adapter function.
- Associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
Explanation
Correct Answer
D:These observations test the actual service profile abstraction mechanism rather than a superficial management status. UCS service profiles abstract server identity and policy from a particular physical compute device.
Incorrect Answers
A:The planned service profile template without checking effective deployed settings. This information cannot independently verify service profile abstraction. The decisive records instead include associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. UCS service profiles abstract server identity and policy from a particular physical compute device.
B:An old inventory export that omits the current chassis and firmware state. This information cannot independently verify service profile abstraction. The decisive records instead include associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. UCS service profiles abstract server identity and policy from a particular physical compute device.
C:A management ping that does not verify the required server or adapter function. This information cannot independently verify service profile abstraction. The decisive records instead include associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. UCS service profiles abstract server identity and policy from a particular physical compute device.
Question 433
A UCS blade hardware replacement should preserve its server identity and connectivity policies but the team manually rebuilds configuration on the chassis. Which platform concept should guide the engineer’s assessment?
- UCS service profiles abstract server identity and policy from a particular physical compute device.
- Out-of-band management reachability guarantees that all host interfaces operate correctly.
- Service profiles can never change effective network identity or firmware behavior.
- All UCS configuration edits take effect without maintenance, validation or dependencies.
Explanation
Correct Answer
A:Validation depends on associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. This explains why the most appropriate response is to apply a reusable UCS service profile or template with centrally governed identity and connectivity policies.
Incorrect Answers
B:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for service profile abstraction. The applicable technical behavior is that UCS service profiles abstract server identity and policy from a particular physical compute device. The operator should verify associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
C:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for service profile abstraction. The applicable technical behavior is that UCS service profiles abstract server identity and policy from a particular physical compute device. The operator should verify associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
D:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for service profile abstraction. The applicable technical behavior is that UCS service profiles abstract server identity and policy from a particular physical compute device. The operator should verify associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
Question 434
A UCS blade hardware replacement should preserve its server identity and connectivity policies but the team manually rebuilds configuration on the chassis. Assume an engineer instead chooses to copy raw chassis serial numbers as the exclusive server networking policy. Which root-cause observation follows from that incorrect change?
- The underlying fault was caused only by retaining accurate firmware inventory.
- Configuring each replacement server independently increases drift and can break storage and network identities.
- A controlled failover test itself proves that the previous outage had no cause.
- The only failure is that the administrator preserved a known-good backup.
Explanation
Correct Answer
B:The proper corrective action is to apply a reusable UCS service profile or template with centrally governed identity and connectivity policies. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual service profile abstraction defect after the shortcut. The meaningful failure is that configuring each replacement server independently increases drift and can break storage and network identities.
C:This does not explain the actual service profile abstraction defect after the shortcut. The relevant evidence is associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
D:This does not explain the actual service profile abstraction defect after the shortcut. The only failure is that the administrator preserved a known-good backup.
Question 435
A UCS blade hardware replacement should preserve its server identity and connectivity policies but the team manually rebuilds configuration on the chassis. The observed failure is: configuring each replacement server independently increases drift and can break storage and network identities. Which recovery action addresses the underlying technical fault?
- Use a switchport description to substitute for all UCS service profile settings.
- Create new random WWPNs for every failover event without revising zoning.
- Associate the approved profile to eligible hardware and verify identities, boot and connectivity.
- Copy raw chassis serial numbers as the exclusive server networking policy.
Explanation
Correct Answer
C:Validate against associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
A:That option would use a switchport description to substitute for all UCS service profile settings, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
B:That option would create new random WWPNs for every failover event without revising zoning, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
D:Copy raw chassis serial numbers as the exclusive server networking policy. This would not reliably restore service after the stated fault. Configuring each replacement server independently increases drift and can break storage and network identities. The controlled recovery is to associate the approved profile to eligible hardware and verify identities, boot and connectivity.
Question 436
A compute team needs repeatable server instantiation with consistent MAC pools, vHBAs, firmware, boot and network policies. What is the BEST supported implementation or corrective action?
- On this affected device, the engineer should use a switchport description to substitute for all UCS service profile settings.
- On this affected device, the engineer should create new random WWPNs for every failover event without revising zoning.
- On this affected device, the engineer should copy raw chassis serial numbers as the exclusive server networking policy.
- On this affected device, the engineer should apply a reusable UCS service profile or template with centrally governed identity and connectivity policies.
Explanation
Correct Answer
D:This directly addresses service profile abstraction because UCS service profiles abstract server identity and policy from a particular physical compute device.
Incorrect Answers
A:Use a switchport description to substitute for all UCS service profile settings. The proposed change targets the wrong mechanism or lacks essential validation. UCS service profiles abstract server identity and policy from a particular physical compute device. Relevant evidence is associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
B:Configuring each replacement server independently increases drift and can break storage and network identities. Create new random WWPNs for every failover event without revising zoning.
C:Configuring each replacement server independently increases drift and can break storage and network identities.
Question 437
A compute team needs repeatable server instantiation with consistent MAC pools, vHBAs, firmware, boot and network policies. Which evidence BEST verifies the intended technical behavior?
- For this deployment, examine associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
- For this deployment, examine an operator assurance without current logs, component inventory or health faults.
- For this deployment, examine the planned service profile template without checking effective deployed settings.
- For this deployment, examine an old inventory export that omits the current chassis and firmware state.
Explanation
Correct Answer
A:These observations test the actual service profile abstraction mechanism rather than a superficial management status. They should be checked after apply a reusable UCS service profile or template with centrally governed identity and connectivity policies.
Incorrect Answers
B:An operator assurance without current logs, component inventory or health faults. This information cannot independently verify service profile abstraction. The decisive records instead include associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. UCS service profiles abstract server identity and policy from a particular physical compute device.
C:The planned service profile template without checking effective deployed settings. This information cannot independently verify service profile abstraction. The decisive records instead include associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. UCS service profiles abstract server identity and policy from a particular physical compute device.
D:An old inventory export that omits the current chassis and firmware state. This information cannot independently verify service profile abstraction. The decisive records instead include associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. UCS service profiles abstract server identity and policy from a particular physical compute device.
Question 438
A compute team needs repeatable server instantiation with consistent MAC pools, vHBAs, firmware, boot and network policies. Which principle BEST explains why the recommended solution is appropriate?
- For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.
- For this condition, the applicable principle is that UCS service profiles abstract server identity and policy from a particular physical compute device.
- For this condition, the applicable principle is that out-of-band management reachability guarantees that all host interfaces operate correctly.
- For this condition, the applicable principle is that two logical objects always provide resilience even if they share one failed hardware path.
Explanation
Correct Answer
B:Validation depends on associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
Incorrect Answers
A:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for service profile abstraction. The applicable technical behavior is that UCS service profiles abstract server identity and policy from a particular physical compute device. The operator should verify associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
C:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for service profile abstraction. The applicable technical behavior is that UCS service profiles abstract server identity and policy from a particular physical compute device. The operator should verify associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
D:Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for service profile abstraction. The applicable technical behavior is that UCS service profiles abstract server identity and policy from a particular physical compute device. The operator should verify associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association.
Question 439
A compute team needs repeatable server instantiation with consistent MAC pools, vHBAs, firmware, boot and network policies. Assume an engineer instead chooses to copy raw chassis serial numbers as the exclusive server networking policy. What is the MOST significant failure introduced by that shortcut?
- The resulting defect is that the only failure is that the administrator preserved a known-good backup.
- The resulting defect is that recording chassis health events is what prevents server management.
- The resulting defect is that configuring each replacement server independently increases drift and can break storage and network identities.
- The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.
Explanation
Correct Answer
C:The proper corrective action is to apply a reusable UCS service profile or template with centrally governed identity and connectivity policies. UCS service profiles abstract server identity and policy from a particular physical compute device.
Incorrect Answers
A:This does not explain the actual service profile abstraction defect after the shortcut. In the given case, a compute team needs repeatable server instantiation with consistent MAC pools, vHBAs, firmware, boot and network policies.
B:This does not explain the actual service profile abstraction defect after the shortcut. Recording chassis health events is what prevents server management.
D:This does not explain the actual service profile abstraction defect after the shortcut. A controlled failover test itself proves that the previous outage had no cause.
Question 440
A compute team needs repeatable server instantiation with consistent MAC pools, vHBAs, firmware, boot and network policies. The observed failure is: configuring each replacement server independently increases drift and can break storage and network identities. What is the BEST controlled recovery once this failure is recognized?
- The controlled remediation is to create new random WWPNs for every failover event without revising zoning.
- The controlled remediation is to copy raw chassis serial numbers as the exclusive server networking policy.
- The controlled remediation is to use a switchport description to substitute for all UCS service profile settings.
- The controlled remediation is to associate the approved profile to eligible hardware and verify identities, boot and connectivity.
Explanation
Correct Answer
D:Validate against associated service profile, assigned identity pools, vNIC and vHBA policy references and successful hardware association. UCS service profiles abstract server identity and policy from a particular physical compute device.
Incorrect Answers
A:Create new random WWPNs for every failover event without revising zoning. This would not reliably restore service after the stated fault. Configuring each replacement server independently increases drift and can break storage and network identities. The controlled recovery is to associate the approved profile to eligible hardware and verify identities, boot and connectivity.
B:Copy raw chassis serial numbers as the exclusive server networking policy. This would not reliably restore service after the stated fault. Configuring each replacement server independently increases drift and can break storage and network identities. The controlled recovery is to associate the approved profile to eligible hardware and verify identities, boot and connectivity.
C:Use a switchport description to substitute for all UCS service profile settings. This would not reliably restore service after the stated fault. Configuring each replacement server independently increases drift and can break storage and network identities. The controlled recovery is to associate the approved profile to eligible hardware and verify identities, boot and connectivity.