Cisco 350-601 Practice Test 43
Question 420
Two cloned compute profiles accidentally reference identical WWPNs and the Fibre Channel fabric reports duplicate identities. The observed failure is: wWPN duplication or exhaustion prevents reliable FC fabric login and storage authorization. What should the engineer do to recover and validate the service?
- The controlled remediation is to disable SAN name-service lookups instead of resolving duplicated WWPNs.
- The controlled remediation is to assign the same WWPN to every blade to enable shared access.
- The controlled remediation is to use a server's IPv4 address as its FC worldwide name.
- The controlled remediation is to repair pool allocation and zone entries for the correct WWPNs, then validate each initiator login.
Explanation
Correct Answer
D:Validate against wWN pool allocations, service-profile vHBA identities, FC fabric login database and uniqueness checks. Fibre Channel SAN zoning and logins rely on stable unique WWN identities for each initiator endpoint.
Incorrect Answers
A:Disable SAN name-service lookups instead of resolving duplicated WWPNs. This would not reliably restore service after the stated fault. WWPN duplication or exhaustion prevents reliable FC fabric login and storage authorization. The controlled recovery is to repair pool allocation and zone entries for the correct WWPNs, then validate each initiator login.
B:Assign the same WWPN to every blade to enable shared access. This would not reliably restore service after the stated fault. WWPN duplication or exhaustion prevents reliable FC fabric login and storage authorization. The controlled recovery is to repair pool allocation and zone entries for the correct WWPNs, then validate each initiator login.
C:Use a server's IPv4 address as its FC worldwide name. This would not reliably restore service after the stated fault. WWPN duplication or exhaustion prevents reliable FC fabric login and storage authorization. The controlled recovery is to repair pool allocation and zone entries for the correct WWPNs, then validate each initiator login.
Question 421
A blade sees both SAN fabrics but cannot boot because its UCS boot policy points to the wrong target LUN. Which operator action best meets this technical requirement?
- Fix the service profile SAN boot device and target/LUN selection according to the approved storage path.
- Set the FI management gateway to the LUN identifier.
- Use only a VMware guest setting to replace host firmware SAN targets.
- Remove both boot targets and rely on automatic discovery.
Explanation
Correct Answer
A:This directly addresses sAN boot policy target order because UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. Confirm the change against UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
Incorrect Answers
B:Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. The relevant correction is to fix the service profile SAN boot device and target/LUN selection according to the approved storage path.
C:Use only a VMware guest setting to replace host firmware SAN targets. The proposed change targets the wrong mechanism or lacks essential validation. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. Relevant evidence is UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
D:Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. The appropriate action remains to fix the service profile SAN boot device and target/LUN selection according to the approved storage path.
Question 422
A blade sees both SAN fabrics but cannot boot because its UCS boot policy points to the wrong target LUN. Which collection of observations most directly tests the suspected cause?
- The rack label without current UCS or Intersight policy associations.
- UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
- A management ping that does not verify the required server or adapter function.
- An operator assurance without current logs, component inventory or health faults.
Explanation
Correct Answer
B:These observations test the actual sAN boot policy target order mechanism rather than a superficial management status. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
Incorrect Answers
A:The rack label without current UCS or Intersight policy associations. This information cannot independently verify sAN boot policy target order. The decisive records instead include UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
C:A management ping that does not verify the required server or adapter function. This information cannot independently verify sAN boot policy target order. The decisive records instead include UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
D:An operator assurance without current logs, component inventory or health faults. This information cannot independently verify sAN boot policy target order. The decisive records instead include UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
Question 423
A blade sees both SAN fabrics but cannot boot because its UCS boot policy points to the wrong target LUN. Which statement most accurately explains this scenario?
- Service profiles can never change effective network identity or firmware behavior.
- Two logical objects always provide resilience even if they share one failed hardware path.
- UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
- A rack server that powers on is automatically configured for every SAN and LAN service.
Explanation
Correct Answer
C:Validation depends on UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot. This explains why the most appropriate response is to fix the service profile SAN boot device and target/LUN selection according to the approved storage path.
Incorrect Answers
A:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for sAN boot policy target order. The applicable technical behavior is that UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. The operator should verify UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
B:Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for sAN boot policy target order. The applicable technical behavior is that UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. The operator should verify UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
D:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for sAN boot policy target order. The applicable technical behavior is that UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. The operator should verify UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
Question 424
A blade sees both SAN fabrics but cannot boot because its UCS boot policy points to the wrong target LUN. Assume an engineer instead chooses to set the FI management gateway to the LUN identifier. What is the principal technical consequence of the mistaken choice?
- Recording chassis health events is what prevents server management.
- Checking effective service-profile bindings caused the original hardware mismatch.
- The underlying fault was caused only by retaining accurate firmware inventory.
- Working FC links do not guarantee a bootable target if the configured target or LUN is wrong.
Explanation
Correct Answer
D:The proper corrective action is to fix the service profile SAN boot device and target/LUN selection according to the approved storage path. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
Incorrect Answers
A:This does not explain the actual sAN boot policy target order defect after the shortcut. The meaningful failure is that working FC links do not guarantee a bootable target if the configured target or LUN is wrong.
B:This does not explain the actual sAN boot policy target order defect after the shortcut. The relevant evidence is UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
C:This does not explain the actual sAN boot policy target order defect after the shortcut. The underlying fault was caused only by retaining accurate firmware inventory.
Question 425
A blade sees both SAN fabrics but cannot boot because its UCS boot policy points to the wrong target LUN. The observed failure is: working FC links do not guarantee a bootable target if the configured target or LUN is wrong. What should the engineer do to recover and validate the service?
- Repair boot policy and storage presentation, then test the primary and backup fabric boot paths.
- Use only a VMware guest setting to replace host firmware SAN targets.
- Remove both boot targets and rely on automatic discovery.
- Set the FI management gateway to the LUN identifier.
Explanation
Correct Answer
A:This addresses the observable fault while preserving a check of the expected result. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
Incorrect Answers
B:That option would use only a VMware guest setting to replace host firmware SAN targets, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
C:That option would remove both boot targets and rely on automatic discovery, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
D:That option would set the FI management gateway to the LUN identifier, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
Question 426
A service profile was moved to replacement hardware and the SAN boot policy still references an obsolete target WWPN. Which next step should the data center engineer select?
- On this affected device, the engineer should use only a VMware guest setting to replace host firmware SAN targets.
- On this affected device, the engineer should fix the service profile SAN boot device and target/LUN selection according to the approved storage path.
- On this affected device, the engineer should remove both boot targets and rely on automatic discovery.
- On this affected device, the engineer should set the FI management gateway to the LUN identifier.
Explanation
Correct Answer
B:This directly addresses sAN boot policy target order because UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
Incorrect Answers
A:Use only a VMware guest setting to replace host firmware SAN targets. The proposed change targets the wrong mechanism or lacks essential validation. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. Relevant evidence is UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
C:Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. Remove both boot targets and rely on automatic discovery.
D:Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. Set the FI management gateway to the LUN identifier.
Question 427
A service profile was moved to replacement hardware and the SAN boot policy still references an obsolete target WWPN. Which diagnostic record would most strongly confirm the result?
- For this deployment, examine the planned service profile template without checking effective deployed settings.
- For this deployment, examine the rack label without current UCS or Intersight policy associations.
- For this deployment, examine UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
- For this deployment, examine a management ping that does not verify the required server or adapter function.
Explanation
Correct Answer
C:These observations test the actual sAN boot policy target order mechanism rather than a superficial management status. They should be checked after fix the service profile SAN boot device and target/LUN selection according to the approved storage path.
Incorrect Answers
A:The planned service profile template without checking effective deployed settings. This information cannot independently verify sAN boot policy target order. The decisive records instead include UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
B:The rack label without current UCS or Intersight policy associations. This information cannot independently verify sAN boot policy target order. The decisive records instead include UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
D:A management ping that does not verify the required server or adapter function. This information cannot independently verify sAN boot policy target order. The decisive records instead include UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
Question 428
A service profile was moved to replacement hardware and the SAN boot policy still references an obsolete target WWPN. Which platform concept should guide the engineer’s assessment?
- For this condition, the applicable principle is that a rack server that powers on is automatically configured for every SAN and LAN service.
- For this condition, the applicable principle is that service profiles can never change effective network identity or firmware behavior.
- For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.
- For this condition, the applicable principle is that UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
Explanation
Correct Answer
D:Validation depends on UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot. UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access.
Incorrect Answers
A:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for sAN boot policy target order. The applicable technical behavior is that UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. The operator should verify UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
B:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for sAN boot policy target order. The applicable technical behavior is that UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. The operator should verify UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
C:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for sAN boot policy target order. The applicable technical behavior is that UCS boot-from-SAN needs consistent firmware boot targets and end-to-end initiator-to-LUN access. The operator should verify UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
Question 429
A service profile was moved to replacement hardware and the SAN boot policy still references an obsolete target WWPN. Assume an engineer instead chooses to set the FI management gateway to the LUN identifier. Which root-cause observation follows from that incorrect change?
- The resulting defect is that working FC links do not guarantee a bootable target if the configured target or LUN is wrong.
- The resulting defect is that the underlying fault was caused only by retaining accurate firmware inventory.
- The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.
- The resulting defect is that checking effective service-profile bindings caused the original hardware mismatch.
Explanation
Correct Answer
A:The proper corrective action is to fix the service profile SAN boot device and target/LUN selection according to the approved storage path. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
B:This does not explain the actual sAN boot policy target order defect after the shortcut. In the given case, a service profile was moved to replacement hardware and the SAN boot policy still references an obsolete target WWPN.
C:This does not explain the actual sAN boot policy target order defect after the shortcut. A controlled failover test itself proves that the previous outage had no cause.
D:This does not explain the actual sAN boot policy target order defect after the shortcut. Checking effective service-profile bindings caused the original hardware mismatch.
Question 430
A service profile was moved to replacement hardware and the SAN boot policy still references an obsolete target WWPN. The observed failure is: working FC links do not guarantee a bootable target if the configured target or LUN is wrong. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to remove both boot targets and rely on automatic discovery.
- The controlled remediation is to repair boot policy and storage presentation, then test the primary and backup fabric boot paths.
- The controlled remediation is to set the FI management gateway to the LUN identifier.
- The controlled remediation is to use only a VMware guest setting to replace host firmware SAN targets.
Explanation
Correct Answer
B:Validate against UCS boot policy entries, target WWPN and LUN, SAN zoning, multipath availability and successful firmware boot.
Incorrect Answers
A:Remove both boot targets and rely on automatic discovery. This would not reliably restore service after the stated fault. Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. The controlled recovery is to repair boot policy and storage presentation, then test the primary and backup fabric boot paths.
C:Set the FI management gateway to the LUN identifier. This would not reliably restore service after the stated fault. Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. The controlled recovery is to repair boot policy and storage presentation, then test the primary and backup fabric boot paths.
D:Use only a VMware guest setting to replace host firmware SAN targets. This would not reliably restore service after the stated fault. Working FC links do not guarantee a bootable target if the configured target or LUN is wrong. The controlled recovery is to repair boot policy and storage presentation, then test the primary and backup fabric boot paths.