Cisco 350-601 Practice Test 41
Question 400
A blade migration creates duplicate MAC warnings because profiles were given overlapping static hardware identities. The observed failure is: exhausted or overlapping pools disrupt provisioning and may cause duplicate Layer 2 endpoints. What is the BEST controlled recovery once this failure is recognized?
- The controlled remediation is to disable address allocation tracking across the UCS domain.
- The controlled remediation is to give every blade the same MAC address to simplify the inventory.
- The controlled remediation is to copy an old VM's FC WWPN as an Ethernet MAC address.
- The controlled remediation is to expand or repair the approved pool, reassign conflicts safely, and verify unique identities.
Explanation
Correct Answer
D:This addresses the observable fault while preserving a check of the expected result. Validate against mAC pool ranges, allocation inventory, service profile failures and duplicate address alerts.
Incorrect Answers
A:Disable address allocation tracking across the UCS domain. This would not reliably restore service after the stated fault. Exhausted or overlapping pools disrupt provisioning and may cause duplicate Layer 2 endpoints. The controlled recovery is to expand or repair the approved pool, reassign conflicts safely, and verify unique identities.
B:Give every blade the same MAC address to simplify the inventory. This would not reliably restore service after the stated fault. Exhausted or overlapping pools disrupt provisioning and may cause duplicate Layer 2 endpoints. The controlled recovery is to expand or repair the approved pool, reassign conflicts safely, and verify unique identities.
C:Copy an old VM's FC WWPN as an Ethernet MAC address. This would not reliably restore service after the stated fault. Exhausted or overlapping pools disrupt provisioning and may cause duplicate Layer 2 endpoints. The controlled recovery is to expand or repair the approved pool, reassign conflicts safely, and verify unique identities.
Question 401
A UCS blade sees no SAN boot target because its vHBA uses a VSAN not present on the connected SAN fabric. What is the BEST supported implementation or corrective action?
- Align the service profile's vHBA, fabric path and VSAN mapping with the intended storage fabric.
- Add the SAN VSAN number as a VLAN on an unrelated Internet-facing switch.
- Disable every HBA on the service profile to force target discovery.
- Modify the compute hostname instead of checking SAN membership.
Explanation
Correct Answer
A:This directly addresses vHBA SAN policy and VSAN because UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. Confirm the change against vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
Incorrect Answers
B:A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. The relevant correction is to align the service profile's vHBA, fabric path and VSAN mapping with the intended storage fabric.
C:That option would disable every HBA on the service profile to force target discovery, but it addresses a different concern. This directly addresses vHBA SAN policy and VSAN because UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN.
D:A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. The appropriate action remains to align the service profile's vHBA, fabric path and VSAN mapping with the intended storage fabric.
Question 402
A UCS blade sees no SAN boot target because its vHBA uses a VSAN not present on the connected SAN fabric. Which evidence BEST verifies the intended technical behavior?
- A management ping that does not verify the required server or adapter function.
- vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
- The planned service profile template without checking effective deployed settings.
- The rack label without current UCS or Intersight policy associations.
Explanation
Correct Answer
B:These observations test the actual vHBA SAN policy and VSAN mechanism rather than a superficial management status. UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN.
Incorrect Answers
A:This information cannot independently verify vHBA SAN policy and VSAN. The decisive records instead include vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
C:This information cannot independently verify vHBA SAN policy and VSAN. UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN.
D:This information cannot independently verify vHBA SAN policy and VSAN. The rack label without current UCS or Intersight policy associations.
Question 403
A UCS blade sees no SAN boot target because its vHBA uses a VSAN not present on the connected SAN fabric. Which principle BEST explains why the recommended solution is appropriate?
- All UCS configuration edits take effect without maintenance, validation or dependencies.
- A rack server that powers on is automatically configured for every SAN and LAN service.
- UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN.
- Service profiles can never change effective network identity or firmware behavior.
Explanation
Correct Answer
C:Validation depends on vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric. This explains why the most appropriate response is to align the service profile's vHBA, fabric path and VSAN mapping with the intended storage fabric.
Incorrect Answers
A:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for vHBA SAN policy and VSAN. The applicable technical behavior is that UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. The operator should verify vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
B:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for vHBA SAN policy and VSAN. The applicable technical behavior is that UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. The operator should verify vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
D:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for vHBA SAN policy and VSAN. The applicable technical behavior is that UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. The operator should verify vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
Question 404
A UCS blade sees no SAN boot target because its vHBA uses a VSAN not present on the connected SAN fabric. Assume an engineer instead chooses to add the SAN VSAN number as a VLAN on an unrelated Internet-facing switch. What is the MOST significant failure introduced by that shortcut?
- Checking effective service-profile bindings caused the original hardware mismatch.
- The underlying fault was caused only by retaining accurate firmware inventory.
- A controlled failover test itself proves that the previous outage had no cause.
- A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation.
Explanation
Correct Answer
D:UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual vHBA SAN policy and VSAN defect after the shortcut. The meaningful failure is that a mismatched VSAN blocks the expected initiator-to-target login despite physical link operation.
B:This does not explain the actual vHBA SAN policy and VSAN defect after the shortcut. The relevant evidence is vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
C:This does not explain the actual vHBA SAN policy and VSAN defect after the shortcut. In the given case, a UCS blade sees no SAN boot target because its vHBA uses a VSAN not present on the connected SAN fabric.
Question 405
A UCS blade sees no SAN boot target because its vHBA uses a VSAN not present on the connected SAN fabric. The observed failure is: a mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. What is the BEST controlled recovery once this failure is recognized?
- Correct SAN policy and VSAN association, then validate initiator login and boot target visibility.
- Disable every HBA on the service profile to force target discovery.
- Modify the compute hostname instead of checking SAN membership.
- Add the SAN VSAN number as a VLAN on an unrelated Internet-facing switch.
Explanation
Correct Answer
A:UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
B:Disable every HBA on the service profile to force target discovery. This would not reliably restore service after the stated fault. A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. The controlled recovery is to correct SAN policy and VSAN association, then validate initiator login and boot target visibility.
C:Modify the compute hostname instead of checking SAN membership. This would not reliably restore service after the stated fault. A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. The controlled recovery is to correct SAN policy and VSAN association, then validate initiator login and boot target visibility.
D:That option would add the SAN VSAN number as a VLAN on an unrelated Internet-facing switch, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
Question 406
An FI uplink is configured for Fibre Channel traffic, but a new service profile's vHBA is associated with the wrong SAN policy. Which configuration decision MOST directly resolves the issue?
- On this affected device, the engineer should disable every HBA on the service profile to force target discovery.
- On this affected device, the engineer should align the service profile's vHBA, fabric path and VSAN mapping with the intended storage fabric.
- On this affected device, the engineer should modify the compute hostname instead of checking SAN membership.
- On this affected device, the engineer should add the SAN VSAN number as a VLAN on an unrelated Internet-facing switch.
Explanation
Correct Answer
B:This directly addresses vHBA SAN policy and VSAN because UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN.
Incorrect Answers
A:Disable every HBA on the service profile to force target discovery. The proposed change targets the wrong mechanism or lacks essential validation. UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. Relevant evidence is vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
C:A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. Modify the compute hostname instead of checking SAN membership.
D:A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. In the given case, an FI uplink is configured for Fibre Channel traffic, but a new service profile's vHBA is associated with the wrong SAN policy.
Question 407
An FI uplink is configured for Fibre Channel traffic, but a new service profile's vHBA is associated with the wrong SAN policy. What should the engineer inspect to confirm the actual state?
- For this deployment, examine an old inventory export that omits the current chassis and firmware state.
- For this deployment, examine a management ping that does not verify the required server or adapter function.
- For this deployment, examine vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
- For this deployment, examine the planned service profile template without checking effective deployed settings.
Explanation
Correct Answer
C:These observations test the actual vHBA SAN policy and VSAN mechanism rather than a superficial management status. They should be checked after align the service profile's vHBA, fabric path and VSAN mapping with the intended storage fabric.
Incorrect Answers
A:This information cannot independently verify vHBA SAN policy and VSAN. An old inventory export that omits the current chassis and firmware state.
B:This information cannot independently verify vHBA SAN policy and VSAN. A management ping that does not verify the required server or adapter function.
D:This information cannot independently verify vHBA SAN policy and VSAN. The planned service profile template without checking effective deployed settings.
Question 408
An FI uplink is configured for Fibre Channel traffic, but a new service profile's vHBA is associated with the wrong SAN policy. What technical behavior underlies the correct decision?
- For this condition, the applicable principle is that service profiles can never change effective network identity or firmware behavior.
- For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.
- For this condition, the applicable principle is that out-of-band management reachability guarantees that all host interfaces operate correctly.
- For this condition, the applicable principle is that UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN.
Explanation
Correct Answer
D:Validation depends on vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
Incorrect Answers
A:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for vHBA SAN policy and VSAN. The applicable technical behavior is that UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. The operator should verify vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
B:All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for vHBA SAN policy and VSAN. The applicable technical behavior is that UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. The operator should verify vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
C:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for vHBA SAN policy and VSAN. The applicable technical behavior is that UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. The operator should verify vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
Question 409
An FI uplink is configured for Fibre Channel traffic, but a new service profile's vHBA is associated with the wrong SAN policy. Assume an engineer instead chooses to add the SAN VSAN number as a VLAN on an unrelated Internet-facing switch. Which resulting risk or fault should the reviewer identify?
- The resulting defect is that a mismatched VSAN blocks the expected initiator-to-target login despite physical link operation.
- The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.
- The resulting defect is that the only failure is that the administrator preserved a known-good backup.
- The resulting defect is that the underlying fault was caused only by retaining accurate firmware inventory.
Explanation
Correct Answer
A:UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. The proper corrective action is to align the service profile's vHBA, fabric path and VSAN mapping with the intended storage fabric.
Incorrect Answers
B:This does not explain the actual vHBA SAN policy and VSAN defect after the shortcut. In the given case, an FI uplink is configured for Fibre Channel traffic, but a new service profile's vHBA is associated with the wrong SAN policy.
C:This does not explain the actual vHBA SAN policy and VSAN defect after the shortcut. The only failure is that the administrator preserved a known-good backup.
D:This does not explain the actual vHBA SAN policy and VSAN defect after the shortcut. The underlying fault was caused only by retaining accurate firmware inventory.
Question 410
An FI uplink is configured for Fibre Channel traffic, but a new service profile's vHBA is associated with the wrong SAN policy. The observed failure is: a mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. Which remediation most directly restores the intended behavior?
- The controlled remediation is to modify the compute hostname instead of checking SAN membership.
- The controlled remediation is to correct SAN policy and VSAN association, then validate initiator login and boot target visibility.
- The controlled remediation is to add the SAN VSAN number as a VLAN on an unrelated Internet-facing switch.
- The controlled remediation is to disable every HBA on the service profile to force target discovery.
Explanation
Correct Answer
B:UCS vHBA connectivity requires a coherent virtual HBA identity and associated Fibre Channel fabric or VSAN. Validate against vHBA VSAN membership, SAN pin group, FI FC uplink state and target login on the fabric.
Incorrect Answers
A:Modify the compute hostname instead of checking SAN membership. This would not reliably restore service after the stated fault. A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. The controlled recovery is to correct SAN policy and VSAN association, then validate initiator login and boot target visibility.
C:Add the SAN VSAN number as a VLAN on an unrelated Internet-facing switch. This would not reliably restore service after the stated fault. A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. The controlled recovery is to correct SAN policy and VSAN association, then validate initiator login and boot target visibility.
D:Disable every HBA on the service profile to force target discovery. This would not reliably restore service after the stated fault. A mismatched VSAN blocks the expected initiator-to-target login despite physical link operation. The controlled recovery is to correct SAN policy and VSAN association, then validate initiator login and boot target visibility.