cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 37

Question 360

An FI network uplink moves to a new port channel but server vNIC traffic remains mapped to a failed or unsupported uplink. The observed failure is: if the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. What is the BEST controlled recovery once this failure is recognized?

  1. The controlled remediation is to disable all alternate uplinks to reduce control-plane choices.
  2. The controlled remediation is to assign a random storage VSAN as the Ethernet pinning group.
  3. The controlled remediation is to move the FI management default gateway into the host OS to repair uplink traffic.
  4. The controlled remediation is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

Explanation

Correct Answer

D:

This addresses the observable fault while preserving a check of the expected result. Validate against uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

Incorrect Answers

A:

Disable all alternate uplinks to reduce control-plane choices. This would not reliably restore service after the stated fault. If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The controlled recovery is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

B:

Assign a random storage VSAN as the Ethernet pinning group. This would not reliably restore service after the stated fault. If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The controlled recovery is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

C:

Move the FI management default gateway into the host OS to repair uplink traffic. This would not reliably restore service after the stated fault. If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The controlled recovery is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

Question 361

A virtualized server sends tagged traffic for a workload VLAN but the UCS vNIC template omits that VLAN. What is the BEST supported implementation or corrective action?

  1. Add the authorized VLAN to the correct UCS LAN and vNIC policy or template and verify upstream allowance.
  2. Delete the VM's IP gateway as a permanent VLAN repair.
  3. Change the server chassis serial number to influence Ethernet tagging.
  4. Assign a Fibre Channel FCID to the Ethernet workload VLAN.

Explanation

Correct Answer

A:

This directly addresses UCS VLAN membership to vNIC because a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. Confirm the change against UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

Incorrect Answers

B:

A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. The relevant correction is to add the authorized VLAN to the correct UCS LAN and vNIC policy or template and verify upstream allowance.

C:

Change the server chassis serial number to influence Ethernet tagging. The proposed change targets the wrong mechanism or lacks essential validation. A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. Relevant evidence is UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

D:

A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. The appropriate action remains to add the authorized VLAN to the correct UCS LAN and vNIC policy or template and verify upstream allowance.

Question 362

A virtualized server sends tagged traffic for a workload VLAN but the UCS vNIC template omits that VLAN. Which evidence BEST verifies the intended technical behavior?

  1. An old inventory export that omits the current chassis and firmware state.
  2. UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.
  3. An operator assurance without current logs, component inventory or health faults.
  4. The planned service profile template without checking effective deployed settings.

Explanation

Correct Answer

B:

These observations test the actual UCS VLAN membership to vNIC mechanism rather than a superficial management status. A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path.

Incorrect Answers

A:

This information cannot independently verify UCS VLAN membership to vNIC. The decisive records instead include UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

C:

This information cannot independently verify UCS VLAN membership to vNIC. A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path.

D:

This information cannot independently verify UCS VLAN membership to vNIC. The planned service profile template without checking effective deployed settings.

Question 363

A virtualized server sends tagged traffic for a workload VLAN but the UCS vNIC template omits that VLAN. Which principle BEST explains why the recommended solution is appropriate?

  1. Two logical objects always provide resilience even if they share one failed hardware path.
  2. All UCS configuration edits take effect without maintenance, validation or dependencies.
  3. A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path.
  4. Out-of-band management reachability guarantees that all host interfaces operate correctly.

Explanation

Correct Answer

C:

Validation depends on UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity. This explains why the most appropriate response is to add the authorized VLAN to the correct UCS LAN and vNIC policy or template and verify upstream allowance.

Incorrect Answers

A:

Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for UCS VLAN membership to vNIC. The applicable technical behavior is that a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. The operator should verify UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

B:

All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for UCS VLAN membership to vNIC. The applicable technical behavior is that a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. The operator should verify UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

D:

Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for UCS VLAN membership to vNIC. The applicable technical behavior is that a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. The operator should verify UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

Question 364

A virtualized server sends tagged traffic for a workload VLAN but the UCS vNIC template omits that VLAN. Assume an engineer instead chooses to delete the VM's IP gateway as a permanent VLAN repair. What is the MOST significant failure introduced by that shortcut?

  1. A controlled failover test itself proves that the previous outage had no cause.
  2. The only failure is that the administrator preserved a known-good backup.
  3. Recording chassis health events is what prevents server management.
  4. A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy.

Explanation

Correct Answer

D:

A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

A:

This does not explain the actual UCS VLAN membership to vNIC defect after the shortcut. The meaningful failure is that a switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy.

B:

This does not explain the actual UCS VLAN membership to vNIC defect after the shortcut. The relevant evidence is UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

C:

This does not explain the actual UCS VLAN membership to vNIC defect after the shortcut. Recording chassis health events is what prevents server management.

Question 365

A virtualized server sends tagged traffic for a workload VLAN but the UCS vNIC template omits that VLAN. The observed failure is: a switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. What is the BEST controlled recovery once this failure is recognized?

  1. Correct VLAN-to-vNIC binding and verify both FI and upstream switch membership.
  2. Change the server chassis serial number to influence Ethernet tagging.
  3. Assign a Fibre Channel FCID to the Ethernet workload VLAN.
  4. Delete the VM's IP gateway as a permanent VLAN repair.

Explanation

Correct Answer

A:

A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. This addresses the observable fault while preserving a check of the expected result.

Incorrect Answers

B:

Change the server chassis serial number to influence Ethernet tagging. This would not reliably restore service after the stated fault. A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. The controlled recovery is to correct VLAN-to-vNIC binding and verify both FI and upstream switch membership.

C:

Assign a Fibre Channel FCID to the Ethernet workload VLAN. This would not reliably restore service after the stated fault. A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. The controlled recovery is to correct VLAN-to-vNIC binding and verify both FI and upstream switch membership.

D:

Delete the VM's IP gateway as a permanent VLAN repair. This would not reliably restore service after the stated fault. A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. The controlled recovery is to correct VLAN-to-vNIC binding and verify both FI and upstream switch membership.

Question 366

An application VM moves to a host whose UCS network policy excludes the required tenant VLAN from vNIC connectivity. Which configuration decision MOST directly resolves the issue?

  1. On this affected device, the engineer should change the server chassis serial number to influence Ethernet tagging.
  2. On this affected device, the engineer should add the authorized VLAN to the correct UCS LAN and vNIC policy or template and verify upstream allowance.
  3. On this affected device, the engineer should assign a Fibre Channel FCID to the Ethernet workload VLAN.
  4. On this affected device, the engineer should delete the VM's IP gateway as a permanent VLAN repair.

Explanation

Correct Answer

B:

This directly addresses UCS VLAN membership to vNIC because a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path.

Incorrect Answers

A:

Change the server chassis serial number to influence Ethernet tagging. The proposed change targets the wrong mechanism or lacks essential validation. A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. Relevant evidence is UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

C:

A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. Assign a Fibre Channel FCID to the Ethernet workload VLAN.

D:

A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. Delete the VM's IP gateway as a permanent VLAN repair.

Question 367

An application VM moves to a host whose UCS network policy excludes the required tenant VLAN from vNIC connectivity. What should the engineer inspect to confirm the actual state?

  1. For this deployment, examine the rack label without current UCS or Intersight policy associations.
  2. For this deployment, examine an old inventory export that omits the current chassis and firmware state.
  3. For this deployment, examine UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.
  4. For this deployment, examine an operator assurance without current logs, component inventory or health faults.

Explanation

Correct Answer

C:

These observations test the actual UCS VLAN membership to vNIC mechanism rather than a superficial management status. They should be checked after add the authorized VLAN to the correct UCS LAN and vNIC policy or template and verify upstream allowance.

Incorrect Answers

A:

This information cannot independently verify UCS VLAN membership to vNIC. The rack label without current UCS or Intersight policy associations.

B:

This information cannot independently verify UCS VLAN membership to vNIC. An old inventory export that omits the current chassis and firmware state.

D:

This information cannot independently verify UCS VLAN membership to vNIC. An operator assurance without current logs, component inventory or health faults.

Question 368

An application VM moves to a host whose UCS network policy excludes the required tenant VLAN from vNIC connectivity. What technical behavior underlies the correct decision?

  1. For this condition, the applicable principle is that out-of-band management reachability guarantees that all host interfaces operate correctly.
  2. For this condition, the applicable principle is that two logical objects always provide resilience even if they share one failed hardware path.
  3. For this condition, the applicable principle is that a rack server that powers on is automatically configured for every SAN and LAN service.
  4. For this condition, the applicable principle is that a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path.

Explanation

Correct Answer

D:

Validation depends on UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity. A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path.

Incorrect Answers

A:

Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for UCS VLAN membership to vNIC. The applicable technical behavior is that a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. The operator should verify UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

B:

Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for UCS VLAN membership to vNIC. The applicable technical behavior is that a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. The operator should verify UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

C:

A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for UCS VLAN membership to vNIC. The applicable technical behavior is that a server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. The operator should verify UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

Question 369

An application VM moves to a host whose UCS network policy excludes the required tenant VLAN from vNIC connectivity. Assume an engineer instead chooses to delete the VM's IP gateway as a permanent VLAN repair. Which resulting risk or fault should the reviewer identify?

  1. The resulting defect is that a switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy.
  2. The resulting defect is that recording chassis health events is what prevents server management.
  3. The resulting defect is that checking effective service-profile bindings caused the original hardware mismatch.
  4. The resulting defect is that the only failure is that the administrator preserved a known-good backup.

Explanation

Correct Answer

A:

A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. The proper corrective action is to add the authorized VLAN to the correct UCS LAN and vNIC policy or template and verify upstream allowance.

Incorrect Answers

B:

This does not explain the actual UCS VLAN membership to vNIC defect after the shortcut. In the given case, an application VM moves to a host whose UCS network policy excludes the required tenant VLAN from vNIC connectivity.

C:

This does not explain the actual UCS VLAN membership to vNIC defect after the shortcut. Checking effective service-profile bindings caused the original hardware mismatch.

D:

This does not explain the actual UCS VLAN membership to vNIC defect after the shortcut. The only failure is that the administrator preserved a known-good backup.

Question 370

An application VM moves to a host whose UCS network policy excludes the required tenant VLAN from vNIC connectivity. The observed failure is: a switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. Which remediation most directly restores the intended behavior?

  1. The controlled remediation is to assign a Fibre Channel FCID to the Ethernet workload VLAN.
  2. The controlled remediation is to correct VLAN-to-vNIC binding and verify both FI and upstream switch membership.
  3. The controlled remediation is to delete the VM's IP gateway as a permanent VLAN repair.
  4. The controlled remediation is to change the server chassis serial number to influence Ethernet tagging.

Explanation

Correct Answer

B:

A server vNIC can carry only VLANs allowed by its UCS policy and actual upstream Ethernet path. Validate against UCS VLAN definitions, vNIC assigned VLANs, upstream trunk allow list and tested endpoint connectivity.

Incorrect Answers

A:

Assign a Fibre Channel FCID to the Ethernet workload VLAN. This would not reliably restore service after the stated fault. A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. The controlled recovery is to correct VLAN-to-vNIC binding and verify both FI and upstream switch membership.

C:

Delete the VM's IP gateway as a permanent VLAN repair. This would not reliably restore service after the stated fault. A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. The controlled recovery is to correct VLAN-to-vNIC binding and verify both FI and upstream switch membership.

D:

Change the server chassis serial number to influence Ethernet tagging. This would not reliably restore service after the stated fault. A switch trunk configuration alone cannot deliver a VLAN excluded from the server's vNIC policy. The controlled recovery is to correct VLAN-to-vNIC binding and verify both FI and upstream switch membership.

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests