Cisco 350-601 Practice Test 35
Question 340
A new UCS domain cannot complete fabric interconnect clustering because management and peer connection prerequisites were skipped. The observed failure is: independent FI initialization prevents the intended managed-domain redundancy and service-profile control. What should the engineer do to recover and validate the service?
- The controlled remediation is to enable FCoE on an unused server port to form a management cluster.
- The controlled remediation is to configure two unrelated UCS domains and assume they form one cluster automatically.
- The controlled remediation is to use a host's DNS alias as a substitute for FI peer connectivity.
- The controlled remediation is to correct cluster cabling and initialization parameters and verify one coordinated UCS domain.
Explanation
Correct Answer
D:Validate against cluster role state, FI peer connectivity, management IPs, domain identity and UCS Manager reachability. UCS Fabric Interconnect clustering depends on correctly paired hardware and consistent domain configuration.
Incorrect Answers
A:Enable FCoE on an unused server port to form a management cluster. This would not reliably restore service after the stated fault. Independent FI initialization prevents the intended managed-domain redundancy and service-profile control. The controlled recovery is to correct cluster cabling and initialization parameters and verify one coordinated UCS domain.
B:Configure two unrelated UCS domains and assume they form one cluster automatically. This would not reliably restore service after the stated fault. Independent FI initialization prevents the intended managed-domain redundancy and service-profile control. The controlled recovery is to correct cluster cabling and initialization parameters and verify one coordinated UCS domain.
C:Use a host's DNS alias as a substitute for FI peer connectivity. This would not reliably restore service after the stated fault. Independent FI initialization prevents the intended managed-domain redundancy and service-profile control. The controlled recovery is to correct cluster cabling and initialization parameters and verify one coordinated UCS domain.
Question 341
A UCS administrator attempts to turn FI Ethernet uplinks into a transit switch and sees unsupported forwarding assumptions. Which operator action best meets this technical requirement?
- Design FI connections using the supported Ethernet end-host forwarding and upstream switching topology.
- Use the FI as the core campus spanning-tree root by default.
- Bridge two unrelated uplinks through FI as a general-purpose switch.
- Disable upstream port channels to force all traffic through server-facing adapters.
Explanation
Correct Answer
A:This directly addresses fabric Interconnect end-host mode because UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. Confirm the change against fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
Incorrect Answers
B:Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The relevant correction is to design FI connections using the supported Ethernet end-host forwarding and upstream switching topology.
C:Bridge two unrelated uplinks through FI as a general-purpose switch. The proposed change targets the wrong mechanism or lacks essential validation. UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. Relevant evidence is fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
D:Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The appropriate action remains to design FI connections using the supported Ethernet end-host forwarding and upstream switching topology.
Question 342
A UCS administrator attempts to turn FI Ethernet uplinks into a transit switch and sees unsupported forwarding assumptions. Which collection of observations most directly tests the suspected cause?
- An operator assurance without current logs, component inventory or health faults.
- FI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
- The rack label without current UCS or Intersight policy associations.
- An old inventory export that omits the current chassis and firmware state.
Explanation
Correct Answer
B:These observations test the actual fabric Interconnect end-host mode mechanism rather than a superficial management status. UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges.
Incorrect Answers
A:This information cannot independently verify fabric Interconnect end-host mode. The decisive records instead include fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
C:This information cannot independently verify fabric Interconnect end-host mode. UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges.
D:This information cannot independently verify fabric Interconnect end-host mode. An old inventory export that omits the current chassis and firmware state.
Question 343
A UCS administrator attempts to turn FI Ethernet uplinks into a transit switch and sees unsupported forwarding assumptions. Which statement most accurately explains this scenario?
- A rack server that powers on is automatically configured for every SAN and LAN service.
- Out-of-band management reachability guarantees that all host interfaces operate correctly.
- UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges.
- Two logical objects always provide resilience even if they share one failed hardware path.
Explanation
Correct Answer
C:Validation depends on fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path. This explains why the most appropriate response is to design FI connections using the supported Ethernet end-host forwarding and upstream switching topology.
Incorrect Answers
A:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for fabric Interconnect end-host mode. The applicable technical behavior is that UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. The operator should verify fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
B:Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for fabric Interconnect end-host mode. The applicable technical behavior is that UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. The operator should verify fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
D:Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for fabric Interconnect end-host mode. The applicable technical behavior is that UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. The operator should verify fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
Question 344
A UCS administrator attempts to turn FI Ethernet uplinks into a transit switch and sees unsupported forwarding assumptions. Assume an engineer instead chooses to use the FI as the core campus spanning-tree root by default. What is the principal technical consequence of the mistaken choice?
- The only failure is that the administrator preserved a known-good backup.
- Recording chassis health events is what prevents server management.
- Checking effective service-profile bindings caused the original hardware mismatch.
- Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths.
Explanation
Correct Answer
D:UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual fabric Interconnect end-host mode defect after the shortcut. The meaningful failure is that treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths.
B:This does not explain the actual fabric Interconnect end-host mode defect after the shortcut. The relevant evidence is fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
C:This does not explain the actual fabric Interconnect end-host mode defect after the shortcut. Checking effective service-profile bindings caused the original hardware mismatch.
Question 345
A UCS administrator attempts to turn FI Ethernet uplinks into a transit switch and sees unsupported forwarding assumptions. The observed failure is: treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. What should the engineer do to recover and validate the service?
- Correct upstream connectivity and pinning design, then validate server-to-network paths.
- Bridge two unrelated uplinks through FI as a general-purpose switch.
- Disable upstream port channels to force all traffic through server-facing adapters.
- Use the FI as the core campus spanning-tree root by default.
Explanation
Correct Answer
A:UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
B:Bridge two unrelated uplinks through FI as a general-purpose switch. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.
C:Disable upstream port channels to force all traffic through server-facing adapters. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.
D:Use the FI as the core campus spanning-tree root by default. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.
Question 346
A rack-to-fabric design relies on UCS fabric interconnects to bridge traffic between unrelated external switches. Which next step should the data center engineer select?
- On this affected device, the engineer should bridge two unrelated uplinks through FI as a general-purpose switch.
- On this affected device, the engineer should design FI connections using the supported Ethernet end-host forwarding and upstream switching topology.
- On this affected device, the engineer should disable upstream port channels to force all traffic through server-facing adapters.
- On this affected device, the engineer should use the FI as the core campus spanning-tree root by default.
Explanation
Correct Answer
B:This directly addresses fabric Interconnect end-host mode because UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges.
Incorrect Answers
A:Bridge two unrelated uplinks through FI as a general-purpose switch. The proposed change targets the wrong mechanism or lacks essential validation. UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. Relevant evidence is fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
C:Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. Disable upstream port channels to force all traffic through server-facing adapters.
D:Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. Use the FI as the core campus spanning-tree root by default.
Question 347
A rack-to-fabric design relies on UCS fabric interconnects to bridge traffic between unrelated external switches. Which diagnostic record would most strongly confirm the result?
- For this deployment, examine a management ping that does not verify the required server or adapter function.
- For this deployment, examine an operator assurance without current logs, component inventory or health faults.
- For this deployment, examine fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
- For this deployment, examine the rack label without current UCS or Intersight policy associations.
Explanation
Correct Answer
C:These observations test the actual fabric Interconnect end-host mode mechanism rather than a superficial management status. They should be checked after design FI connections using the supported Ethernet end-host forwarding and upstream switching topology.
Incorrect Answers
A:This information cannot independently verify fabric Interconnect end-host mode. A management ping that does not verify the required server or adapter function.
B:This information cannot independently verify fabric Interconnect end-host mode. An operator assurance without current logs, component inventory or health faults.
D:This information cannot independently verify fabric Interconnect end-host mode. The rack label without current UCS or Intersight policy associations.
Question 348
A rack-to-fabric design relies on UCS fabric interconnects to bridge traffic between unrelated external switches. Which platform concept should guide the engineer’s assessment?
- For this condition, the applicable principle is that two logical objects always provide resilience even if they share one failed hardware path.
- For this condition, the applicable principle is that a rack server that powers on is automatically configured for every SAN and LAN service.
- For this condition, the applicable principle is that service profiles can never change effective network identity or firmware behavior.
- For this condition, the applicable principle is that UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges.
Explanation
Correct Answer
D:Validation depends on fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path. UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges.
Incorrect Answers
A:Two logical objects always provide resilience even if they share one failed hardware path. This is an incorrect generalization for fabric Interconnect end-host mode. The applicable technical behavior is that UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. The operator should verify fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
B:A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for fabric Interconnect end-host mode. The applicable technical behavior is that UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. The operator should verify fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
C:Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for fabric Interconnect end-host mode. The applicable technical behavior is that UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. The operator should verify fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
Question 349
A rack-to-fabric design relies on UCS fabric interconnects to bridge traffic between unrelated external switches. Assume an engineer instead chooses to use the FI as the core campus spanning-tree root by default. Which root-cause observation follows from that incorrect change?
- The resulting defect is that treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths.
- The resulting defect is that checking effective service-profile bindings caused the original hardware mismatch.
- The resulting defect is that the underlying fault was caused only by retaining accurate firmware inventory.
- The resulting defect is that recording chassis health events is what prevents server management.
Explanation
Correct Answer
A:UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. The proper corrective action is to design FI connections using the supported Ethernet end-host forwarding and upstream switching topology.
Incorrect Answers
B:This does not explain the actual fabric Interconnect end-host mode defect after the shortcut. In the given case, a rack-to-fabric design relies on UCS fabric interconnects to bridge traffic between unrelated external switches.
C:This does not explain the actual fabric Interconnect end-host mode defect after the shortcut. The underlying fault was caused only by retaining accurate firmware inventory.
D:This does not explain the actual fabric Interconnect end-host mode defect after the shortcut. Recording chassis health events is what prevents server management.
Question 350
A rack-to-fabric design relies on UCS fabric interconnects to bridge traffic between unrelated external switches. The observed failure is: treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to disable upstream port channels to force all traffic through server-facing adapters.
- The controlled remediation is to correct upstream connectivity and pinning design, then validate server-to-network paths.
- The controlled remediation is to use the FI as the core campus spanning-tree root by default.
- The controlled remediation is to bridge two unrelated uplinks through FI as a general-purpose switch.
Explanation
Correct Answer
B:UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. Validate against fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.
Incorrect Answers
A:Disable upstream port channels to force all traffic through server-facing adapters. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.
C:Use the FI as the core campus spanning-tree root by default. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.
D:Bridge two unrelated uplinks through FI as a general-purpose switch. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.