cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 36

Question 350

A rack-to-fabric design relies on UCS fabric interconnects to bridge traffic between unrelated external switches. The observed failure is: treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. Which recovery action addresses the underlying technical fault?

  1. The controlled remediation is to disable upstream port channels to force all traffic through server-facing adapters.
  2. The controlled remediation is to correct upstream connectivity and pinning design, then validate server-to-network paths.
  3. The controlled remediation is to use the FI as the core campus spanning-tree root by default.
  4. The controlled remediation is to bridge two unrelated uplinks through FI as a general-purpose switch.

Explanation

Correct Answer

B:

UCS fabric interconnects in end-host mode provide server connectivity rather than acting as arbitrary transit bridges. Validate against fI Ethernet switching mode, pinning status, uplink sets and observed forwarding path.

Incorrect Answers

A:

Disable upstream port channels to force all traffic through server-facing adapters. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.

C:

Use the FI as the core campus spanning-tree root by default. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.

D:

Bridge two unrelated uplinks through FI as a general-purpose switch. This would not reliably restore service after the stated fault. Treating FI end-host mode as an aggregation switch can cause loops or blackholes from invalid traffic paths. The controlled recovery is to correct upstream connectivity and pinning design, then validate server-to-network paths.

Question 351

Servers in one UCS domain lose northbound connectivity when a pinned uplink fails and no eligible alternate uplink exists. Which next step should the data center engineer select?

  1. Assign a random storage VSAN as the Ethernet pinning group.
  2. Move the FI management default gateway into the host OS to repair uplink traffic.
  3. Check FI uplink pinning and available eligible uplink groups, then restore supported alternate connectivity.
  4. Disable all alternate uplinks to reduce control-plane choices.

Explanation

Correct Answer

C:

This directly addresses UCS fabric uplink pinning because UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. Confirm the change against uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

Incorrect Answers

A:

If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The relevant correction is to check FI uplink pinning and available eligible uplink groups, then restore supported alternate connectivity.

B:

Move the FI management default gateway into the host OS to repair uplink traffic. The proposed change targets the wrong mechanism or lacks essential validation. UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. Relevant evidence is uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

D:

If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The appropriate action remains to check FI uplink pinning and available eligible uplink groups, then restore supported alternate connectivity.

Question 352

Servers in one UCS domain lose northbound connectivity when a pinned uplink fails and no eligible alternate uplink exists. Which diagnostic record would most strongly confirm the result?

  1. A management ping that does not verify the required server or adapter function.
  2. The planned service profile template without checking effective deployed settings.
  3. The rack label without current UCS or Intersight policy associations.
  4. Uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

Explanation

Correct Answer

D:

These observations test the actual UCS fabric uplink pinning mechanism rather than a superficial management status. UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior.

Incorrect Answers

A:

This information cannot independently verify UCS fabric uplink pinning. The decisive records instead include uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

B:

This information cannot independently verify UCS fabric uplink pinning. UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior.

C:

This information cannot independently verify UCS fabric uplink pinning. The rack label without current UCS or Intersight policy associations.

Question 353

Servers in one UCS domain lose northbound connectivity when a pinned uplink fails and no eligible alternate uplink exists. Which platform concept should guide the engineer’s assessment?

  1. UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior.
  2. All UCS configuration edits take effect without maintenance, validation or dependencies.
  3. A rack server that powers on is automatically configured for every SAN and LAN service.
  4. Service profiles can never change effective network identity or firmware behavior.

Explanation

Correct Answer

A:

Validation depends on uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership. This explains why the most appropriate response is to check FI uplink pinning and available eligible uplink groups, then restore supported alternate connectivity.

Incorrect Answers

B:

All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for UCS fabric uplink pinning. The applicable technical behavior is that UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. The operator should verify uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

C:

A rack server that powers on is automatically configured for every SAN and LAN service. This is an incorrect generalization for UCS fabric uplink pinning. The applicable technical behavior is that UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. The operator should verify uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

D:

Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for UCS fabric uplink pinning. The applicable technical behavior is that UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. The operator should verify uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

Question 354

Servers in one UCS domain lose northbound connectivity when a pinned uplink fails and no eligible alternate uplink exists. Assume an engineer instead chooses to assign a random storage VSAN as the Ethernet pinning group. Which root-cause observation follows from that incorrect change?

  1. Checking effective service-profile bindings caused the original hardware mismatch.
  2. If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links.
  3. The underlying fault was caused only by retaining accurate firmware inventory.
  4. A controlled failover test itself proves that the previous outage had no cause.

Explanation

Correct Answer

B:

The proper corrective action is to check FI uplink pinning and available eligible uplink groups, then restore supported alternate connectivity. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

A:

This does not explain the actual UCS fabric uplink pinning defect after the shortcut. The meaningful failure is that if the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links.

C:

This does not explain the actual UCS fabric uplink pinning defect after the shortcut. The relevant evidence is uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

D:

This does not explain the actual UCS fabric uplink pinning defect after the shortcut. In the given case, servers in one UCS domain lose northbound connectivity when a pinned uplink fails and no eligible alternate uplink exists.

Question 355

Servers in one UCS domain lose northbound connectivity when a pinned uplink fails and no eligible alternate uplink exists. The observed failure is: if the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. Which recovery action addresses the underlying technical fault?

  1. Move the FI management default gateway into the host OS to repair uplink traffic.
  2. Disable all alternate uplinks to reduce control-plane choices.
  3. Repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.
  4. Assign a random storage VSAN as the Ethernet pinning group.

Explanation

Correct Answer

C:

This addresses the observable fault while preserving a check of the expected result. UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior.

Incorrect Answers

A:

Move the FI management default gateway into the host OS to repair uplink traffic. This would not reliably restore service after the stated fault. If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The controlled recovery is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

B:

That option would disable all alternate uplinks to reduce control-plane choices, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.

D:

That option would assign a random storage VSAN as the Ethernet pinning group, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.

Question 356

An FI network uplink moves to a new port channel but server vNIC traffic remains mapped to a failed or unsupported uplink. What is the BEST supported implementation or corrective action?

  1. On this affected device, the engineer should move the FI management default gateway into the host OS to repair uplink traffic.
  2. On this affected device, the engineer should disable all alternate uplinks to reduce control-plane choices.
  3. On this affected device, the engineer should assign a random storage VSAN as the Ethernet pinning group.
  4. On this affected device, the engineer should check FI uplink pinning and available eligible uplink groups, then restore supported alternate connectivity.

Explanation

Correct Answer

D:

This directly addresses UCS fabric uplink pinning because UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior.

Incorrect Answers

A:

Move the FI management default gateway into the host OS to repair uplink traffic. The proposed change targets the wrong mechanism or lacks essential validation. UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. Relevant evidence is uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

B:

If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links.

C:

If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. Assign a random storage VSAN as the Ethernet pinning group.

Question 357

An FI network uplink moves to a new port channel but server vNIC traffic remains mapped to a failed or unsupported uplink. Which evidence BEST verifies the intended technical behavior?

  1. For this deployment, examine uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.
  2. For this deployment, examine an old inventory export that omits the current chassis and firmware state.
  3. For this deployment, examine a management ping that does not verify the required server or adapter function.
  4. For this deployment, examine the planned service profile template without checking effective deployed settings.

Explanation

Correct Answer

A:

These observations test the actual UCS fabric uplink pinning mechanism rather than a superficial management status. They should be checked after check FI uplink pinning and available eligible uplink groups, then restore supported alternate connectivity.

Incorrect Answers

B:

This information cannot independently verify UCS fabric uplink pinning. An old inventory export that omits the current chassis and firmware state.

C:

This information cannot independently verify UCS fabric uplink pinning. A management ping that does not verify the required server or adapter function.

D:

This information cannot independently verify UCS fabric uplink pinning. The planned service profile template without checking effective deployed settings.

Question 358

An FI network uplink moves to a new port channel but server vNIC traffic remains mapped to a failed or unsupported uplink. Which principle BEST explains why the recommended solution is appropriate?

  1. For this condition, the applicable principle is that service profiles can never change effective network identity or firmware behavior.
  2. For this condition, the applicable principle is that UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior.
  3. For this condition, the applicable principle is that all UCS configuration edits take effect without maintenance, validation or dependencies.
  4. For this condition, the applicable principle is that out-of-band management reachability guarantees that all host interfaces operate correctly.

Explanation

Correct Answer

B:

Validation depends on uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

Incorrect Answers

A:

Service profiles can never change effective network identity or firmware behavior. This is an incorrect generalization for UCS fabric uplink pinning. The applicable technical behavior is that UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. The operator should verify uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

C:

All UCS configuration edits take effect without maintenance, validation or dependencies. This is an incorrect generalization for UCS fabric uplink pinning. The applicable technical behavior is that UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. The operator should verify uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

D:

Out-of-band management reachability guarantees that all host interfaces operate correctly. This is an incorrect generalization for UCS fabric uplink pinning. The applicable technical behavior is that UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior. The operator should verify uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

Question 359

An FI network uplink moves to a new port channel but server vNIC traffic remains mapped to a failed or unsupported uplink. Assume an engineer instead chooses to assign a random storage VSAN as the Ethernet pinning group. What is the MOST significant failure introduced by that shortcut?

  1. The resulting defect is that a controlled failover test itself proves that the previous outage had no cause.
  2. The resulting defect is that the only failure is that the administrator preserved a known-good backup.
  3. The resulting defect is that if the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links.
  4. The resulting defect is that the underlying fault was caused only by retaining accurate firmware inventory.

Explanation

Correct Answer

C:

The proper corrective action is to check FI uplink pinning and available eligible uplink groups, then restore supported alternate connectivity. UCS Ethernet forwarding associates server-facing traffic with usable upstream uplinks through configured pinning behavior.

Incorrect Answers

A:

This does not explain the actual UCS fabric uplink pinning defect after the shortcut. In the given case, an FI network uplink moves to a new port channel but server vNIC traffic remains mapped to a failed or unsupported uplink.

B:

This does not explain the actual UCS fabric uplink pinning defect after the shortcut. The only failure is that the administrator preserved a known-good backup.

D:

This does not explain the actual UCS fabric uplink pinning defect after the shortcut. The underlying fault was caused only by retaining accurate firmware inventory.

Question 360

An FI network uplink moves to a new port channel but server vNIC traffic remains mapped to a failed or unsupported uplink. The observed failure is: if the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. What is the BEST controlled recovery once this failure is recognized?

  1. The controlled remediation is to disable all alternate uplinks to reduce control-plane choices.
  2. The controlled remediation is to assign a random storage VSAN as the Ethernet pinning group.
  3. The controlled remediation is to move the FI management default gateway into the host OS to repair uplink traffic.
  4. The controlled remediation is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

Explanation

Correct Answer

D:

This addresses the observable fault while preserving a check of the expected result. Validate against uplink operational state, server vNIC pinning, failover behavior, and upstream port-channel membership.

Incorrect Answers

A:

Disable all alternate uplinks to reduce control-plane choices. This would not reliably restore service after the stated fault. If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The controlled recovery is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

B:

Assign a random storage VSAN as the Ethernet pinning group. This would not reliably restore service after the stated fault. If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The controlled recovery is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

C:

Move the FI management default gateway into the host OS to repair uplink traffic. This would not reliably restore service after the stated fault. If the only usable pinned path is down, server traffic can be isolated despite healthy physical vNIC links. The controlled recovery is to repair eligible FI uplinks and verify supported pinning and vNIC failover after a controlled link test.

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests