Cisco 350-601 Practice Test 115
Question 1140
A UCS service desk account unexpectedly can modify compute boot and firmware policy through excess role permissions. The observed failure is: overprivileged accounts increase the chance of accidental or malicious workload disruption. What should the engineer do to recover and validate the service?
- The controlled remediation is to disable UCS user accounting to simplify least-privilege testing.
- The controlled remediation is to share one UCS administrator account across all audit and operation teams.
- The controlled remediation is to treat hardware serial numbers as substitutes for user authorization policy.
- The controlled remediation is to constrain the role and organization rights and verify practical permissions after login.
Explanation
Correct Answer
D:Validate against UCS user roles, role privileges, organization assignment and permitted or denied command actions. UCS RBAC can separate server operations from monitoring and administrative functions.
Incorrect Answers
A:Disable UCS user accounting to simplify least-privilege testing. This would not reliably restore service after the stated fault. Overprivileged accounts increase the chance of accidental or malicious workload disruption. The controlled recovery is to constrain the role and organization rights and verify practical permissions after login.
B:Share one UCS administrator account across all audit and operation teams. This would not reliably restore service after the stated fault. Overprivileged accounts increase the chance of accidental or malicious workload disruption. The controlled recovery is to constrain the role and organization rights and verify practical permissions after login.
C:Treat hardware serial numbers as substitutes for user authorization policy. This would not reliably restore service after the stated fault. Overprivileged accounts increase the chance of accidental or malicious workload disruption. The controlled recovery is to constrain the role and organization rights and verify practical permissions after login.
Question 1141
An MDS operator can authenticate against RADIUS but lacks authorization to apply approved zoning changes. Which operator action best meets this technical requirement?
- Correct MDS AAA and role mapping according to documented SAN administrative responsibilities.
- Assume UCS fabric interconnect roles are identical to all MDS roles.
- Give every SAN operator unfettered administrative rights without review.
- Disable remote AAA permanently because a single zoning command failed.
Explanation
Correct Answer
A:This directly addresses mDS AAA administrative access because mDS SAN devices independently enforce administrative authentication and role-based permissions. Confirm the change against mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
Incorrect Answers
B:Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. The relevant correction is to correct MDS AAA and role mapping according to documented SAN administrative responsibilities.
C:Give every SAN operator unfettered administrative rights without review. The proposed change targets the wrong mechanism or lacks essential validation. MDS SAN devices independently enforce administrative authentication and role-based permissions. Relevant evidence is mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
D:Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. The appropriate action remains to correct MDS AAA and role mapping according to documented SAN administrative responsibilities.
Question 1142
An MDS operator can authenticate against RADIUS but lacks authorization to apply approved zoning changes. Which collection of observations most directly tests the suspected cause?
- A green link LED without confirming authentication, inspection or encryption state.
- MDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
- A user account name without the effective role or security enforcement record.
- An old role mapping that ignores the observed denial or unwanted permission.
Explanation
Correct Answer
B:These observations test the actual mDS AAA administrative access mechanism rather than a superficial management status. MDS SAN devices independently enforce administrative authentication and role-based permissions.
Incorrect Answers
A:This information cannot independently verify mDS AAA administrative access. The decisive records instead include mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
C:This information cannot independently verify mDS AAA administrative access. MDS SAN devices independently enforce administrative authentication and role-based permissions.
D:This information cannot independently verify mDS AAA administrative access. In the given case, an MDS operator can authenticate against RADIUS but lacks authorization to apply approved zoning changes.
Question 1143
An MDS operator can authenticate against RADIUS but lacks authorization to apply approved zoning changes. Which statement most accurately explains this scenario?
- Successful login automatically grants every management privilege.
- A recognized device name establishes authentication and trust without checking keys.
- MDS SAN devices independently enforce administrative authentication and role-based permissions.
- One security mechanism always replaces all other layer-specific access controls.
Explanation
Correct Answer
C:Validation depends on mDS login realm, returned privilege role, AAA server logs and attempted zoning command results. This explains why the most appropriate response is to correct MDS AAA and role mapping according to documented SAN administrative responsibilities.
Incorrect Answers
A:Successful login automatically grants every management privilege. This is an incorrect generalization for mDS AAA administrative access. The applicable technical behavior is that mDS SAN devices independently enforce administrative authentication and role-based permissions. The operator should verify mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
B:A recognized device name establishes authentication and trust without checking keys. This is an incorrect generalization for mDS AAA administrative access. The applicable technical behavior is that mDS SAN devices independently enforce administrative authentication and role-based permissions. The operator should verify mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
D:One security mechanism always replaces all other layer-specific access controls. This is an incorrect generalization for mDS AAA administrative access. The applicable technical behavior is that mDS SAN devices independently enforce administrative authentication and role-based permissions. The operator should verify mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
Question 1144
An MDS operator can authenticate against RADIUS but lacks authorization to apply approved zoning changes. Assume an engineer instead chooses to assume UCS fabric interconnect roles are identical to all MDS roles. What is the principal technical consequence of the mistaken choice?
- Testing one denied unauthorized connection proves the policy was absent.
- A correctly scoped role assignment is the source of the earlier over-privilege.
- Auditing administrative actions is the cause of the initial unauthorized access.
- Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy.
Explanation
Correct Answer
D:The proper corrective action is to correct MDS AAA and role mapping according to documented SAN administrative responsibilities. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual mDS AAA administrative access defect after the shortcut. The meaningful failure is that using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy.
B:This does not explain the actual mDS AAA administrative access defect after the shortcut. The relevant evidence is mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
C:This does not explain the actual mDS AAA administrative access defect after the shortcut. In the given case, an MDS operator can authenticate against RADIUS but lacks authorization to apply approved zoning changes.
Question 1145
An MDS operator can authenticate against RADIUS but lacks authorization to apply approved zoning changes. The observed failure is: using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. What should the engineer do to recover and validate the service?
- Repair the mapped authorization and test intended zoning commands with audit records.
- Give every SAN operator unfettered administrative rights without review.
- Disable remote AAA permanently because a single zoning command failed.
- Assume UCS fabric interconnect roles are identical to all MDS roles.
Explanation
Correct Answer
A:Validate against mDS login realm, returned privilege role, AAA server logs and attempted zoning command results. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
B:Give every SAN operator unfettered administrative rights without review. This would not reliably restore service after the stated fault. Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. The controlled recovery is to repair the mapped authorization and test intended zoning commands with audit records.
C:Disable remote AAA permanently because a single zoning command failed. This would not reliably restore service after the stated fault. Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. The controlled recovery is to repair the mapped authorization and test intended zoning commands with audit records.
D:Assume UCS fabric interconnect roles are identical to all MDS roles. This would not reliably restore service after the stated fault. Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. The controlled recovery is to repair the mapped authorization and test intended zoning commands with audit records.
Question 1146
A SAN administrator has full administrative access on one FC switch but a restricted role on another despite the same identity. Which next step should the data center engineer select?
- On this affected device, the engineer should give every SAN operator unfettered administrative rights without review.
- On this affected device, the engineer should correct MDS AAA and role mapping according to documented SAN administrative responsibilities.
- On this affected device, the engineer should disable remote AAA permanently because a single zoning command failed.
- On this affected device, the engineer should assume UCS fabric interconnect roles are identical to all MDS roles.
Explanation
Correct Answer
B:This directly addresses mDS AAA administrative access because mDS SAN devices independently enforce administrative authentication and role-based permissions.
Incorrect Answers
A:Give every SAN operator unfettered administrative rights without review. The proposed change targets the wrong mechanism or lacks essential validation. MDS SAN devices independently enforce administrative authentication and role-based permissions. Relevant evidence is mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
C:Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. Disable remote AAA permanently because a single zoning command failed.
D:Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy.
Question 1147
A SAN administrator has full administrative access on one FC switch but a restricted role on another despite the same identity. Which diagnostic record would most strongly confirm the result?
- For this deployment, examine one successful management ping without validating the applicable policy.
- For this deployment, examine a green link LED without confirming authentication, inspection or encryption state.
- For this deployment, examine mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
- For this deployment, examine a user account name without the effective role or security enforcement record.
Explanation
Correct Answer
C:These observations test the actual mDS AAA administrative access mechanism rather than a superficial management status. They should be checked after correct MDS AAA and role mapping according to documented SAN administrative responsibilities.
Incorrect Answers
A:This information cannot independently verify mDS AAA administrative access. One successful management ping without validating the applicable policy.
B:This information cannot independently verify mDS AAA administrative access. A green link LED without confirming authentication, inspection or encryption state.
D:This information cannot independently verify mDS AAA administrative access. A user account name without the effective role or security enforcement record.
Question 1148
A SAN administrator has full administrative access on one FC switch but a restricted role on another despite the same identity. Which platform concept should guide the engineer’s assessment?
- For this condition, the applicable principle is that one security mechanism always replaces all other layer-specific access controls.
- For this condition, the applicable principle is that successful login automatically grants every management privilege.
- For this condition, the applicable principle is that physical connectivity makes all ACI contract and security policies optional.
- For this condition, the applicable principle is that mDS SAN devices independently enforce administrative authentication and role-based permissions.
Explanation
Correct Answer
D:Validation depends on mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
Incorrect Answers
A:One security mechanism always replaces all other layer-specific access controls. This is an incorrect generalization for mDS AAA administrative access. The applicable technical behavior is that mDS SAN devices independently enforce administrative authentication and role-based permissions. The operator should verify mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
B:Successful login automatically grants every management privilege. This is an incorrect generalization for mDS AAA administrative access. The applicable technical behavior is that mDS SAN devices independently enforce administrative authentication and role-based permissions. The operator should verify mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
C:Physical connectivity makes all ACI contract and security policies optional. This is an incorrect generalization for mDS AAA administrative access. The applicable technical behavior is that mDS SAN devices independently enforce administrative authentication and role-based permissions. The operator should verify mDS login realm, returned privilege role, AAA server logs and attempted zoning command results.
Question 1149
A SAN administrator has full administrative access on one FC switch but a restricted role on another despite the same identity. Assume an engineer instead chooses to assume UCS fabric interconnect roles are identical to all MDS roles. Which root-cause observation follows from that incorrect change?
- The resulting defect is that using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy.
- The resulting defect is that auditing administrative actions is the cause of the initial unauthorized access.
- The resulting defect is that keeping valid key rotation records automatically disables the correct peer trust.
- The resulting defect is that a correctly scoped role assignment is the source of the earlier over-privilege.
Explanation
Correct Answer
A:The proper corrective action is to correct MDS AAA and role mapping according to documented SAN administrative responsibilities. MDS SAN devices independently enforce administrative authentication and role-based permissions.
Incorrect Answers
B:This does not explain the actual mDS AAA administrative access defect after the shortcut. In the given case, a SAN administrator has full administrative access on one FC switch but a restricted role on another despite the same identity.
C:This does not explain the actual mDS AAA administrative access defect after the shortcut. Keeping valid key rotation records automatically disables the correct peer trust.
D:This does not explain the actual mDS AAA administrative access defect after the shortcut. A correctly scoped role assignment is the source of the earlier over-privilege.
Question 1150
A SAN administrator has full administrative access on one FC switch but a restricted role on another despite the same identity. The observed failure is: using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to disable remote AAA permanently because a single zoning command failed.
- The controlled remediation is to repair the mapped authorization and test intended zoning commands with audit records.
- The controlled remediation is to assume UCS fabric interconnect roles are identical to all MDS roles.
- The controlled remediation is to give every SAN operator unfettered administrative rights without review.
Explanation
Correct Answer
B:Validate against mDS login realm, returned privilege role, AAA server logs and attempted zoning command results. MDS SAN devices independently enforce administrative authentication and role-based permissions.
Incorrect Answers
A:Disable remote AAA permanently because a single zoning command failed. This would not reliably restore service after the stated fault. Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. The controlled recovery is to repair the mapped authorization and test intended zoning commands with audit records.
C:Assume UCS fabric interconnect roles are identical to all MDS roles. This would not reliably restore service after the stated fault. Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. The controlled recovery is to repair the mapped authorization and test intended zoning commands with audit records.
D:Give every SAN operator unfettered administrative rights without review. This would not reliably restore service after the stated fault. Using incorrect roles on a fabric switch can either block required maintenance or expose critical zoning policy. The controlled recovery is to repair the mapped authorization and test intended zoning commands with audit records.