cert
cert-1
cert-2

Pass CompTIA SK0-005 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
SK0-005 Exam - Verified By Experts
SK0-005 Premium Bundle
$29.98

SK0-005 Premium Bundle

$79.99
$109.97
  • Premium File 617 Questions & Answers. Last update: Nov 13, 2026
  • Training Course 139 Video Lectures
  • Study Guide 533 Pages
 
$109.97
$79.99
accept 21 downloads in last 7 days
block-screenshots
Purchase CompTIA SK0-005 Exam Training Products Individually
CompTIA SK0-005 Premium File
Premium File 617 Q&A
$76.99$69.99
CompTIA SK0-005 Video Training Course
Training Course 139 Lectures
$21.99 $19.99
CompTIA SK0-005 PDF Study Guide
Study Guide 533 Pages
$21.99 $19.99
CompTIA SK0-005 Practice Test 7

Question 60

A change board is planning a verified response to this server event: A file server with small random writes is being migrated from mirrored disks to a parity-only stripe solely to maximize reported usable capacity. For the RAID fault tolerance versus performance issue, which response elements belong in the approved plan? Select TWO answers.

  1. Both planned storage paths are available and storage latency remains within limits during controlled network failover.
  2. Choose a RAID level that meets measured capacity, write profile and disk-failure tolerance requirements, and retain independent backups.
  3. Assume that any RAID level, including striping without parity, guarantees single-disk survival.
  4. Select enterprise SSD endurance for the expected write volume and monitor NVMe health, utilization and replacement thresholds.
  5. Review workload I/O pattern, required fault tolerance, array health, usable capacity and rebuild time estimates.

Explanation

Correct Answer

B:

RAID 0 offers no disk fault tolerance; parity and mirrors have different write and rebuild characteristics, and none replaces backup. Before rollout, confirm the problem with: Review workload I/O pattern, required fault tolerance, array health, usable capacity and rebuild time estimates.

E:

These observations investigate the exact RAID fault tolerance versus performance failure rather than unrelated components. The expected technical relationship is: RAID 0 offers no disk fault tolerance; parity and mirrors have different write and rebuild characteristics, and none replaces backup.

Incorrect Answers

A:

This statement concerns iSCSI network isolation and MPIO, a different Server+ technical control. It does not directly address the reported RAID fault tolerance versus performance fault or prove its repair.

C:

This is the unsafe shortcut in the RAID fault tolerance versus performance scenario, not a justified remediation or diagnostic. RAID 0 offers no disk fault tolerance; parity and mirrors have different write and rebuild characteristics, and none replaces backup.

D:

That option would select enterprise SSD endurance for the expected write volume and monitor NVMe health, utilization and replacement thresholds, but it addresses a different concern. RAID 0 offers no disk fault tolerance; parity and mirrors have different write and rebuild characteristics, and none replaces backup.

Question 61

A server administrator is investigating a server issue involving hot spare eligibility and rebuild supervision: A disk array enters a degraded state after one member fails, but its designated hot spare is smaller than the failed drive and never joins the rebuild. The change must address the documented fault without creating unrelated risk. Which corrective action is most appropriate? Select ONE best answer.

  1. Provide compatible spare capacity and interface, replace the failed member, monitor the rebuild and verify array redundancy after completion.
  2. Choose a RAID level that meets measured capacity, write profile and disk-failure tolerance requirements, and retain independent backups.
  3. Declare an array healthy as soon as a replacement disk's activity light turns on.
  4. Rescan the device, extend the correct partition or volume manager layer and grow the supported filesystem using a backed-up change plan.

Explanation

Correct Answer

A:

An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

Incorrect Answers

B:

That option would choose a RAID level that meets measured capacity, write profile and disk-failure tolerance requirements, and retain independent backups, but it addresses a different concern. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

C:

This is the unsafe shortcut in the Hot spare eligibility and rebuild supervision scenario, not a justified remediation or diagnostic. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

D:

This statement concerns Filesystem growth after LUN expansion, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

Question 62

While reviewing the CompTIA Server+ administration incident, a technician learns: A disk array enters a degraded state after one member fails, but its designated hot spare is smaller than the failed drive and never joins the rebuild. Which principle most directly explains how to address the described issue safely? Select ONE best answer.

  1. SAN high availability requires correctly presented LUNs over multiple independent usable fabric paths, not redundant cables alone.
  2. Flash storage performance and life depend on workload write intensity, remaining spare blocks and device health telemetry.
  3. Stable iSCSI performance and resilience depend on end-to-end network path design and host multipathing, not simply the number of NICs.
  4. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

Explanation

Correct Answer

D:

The acceptance test is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

Incorrect Answers

A:

This statement concerns Fibre Channel SAN zoning and multipath, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

B:

This statement concerns NVMe endurance and capacity monitoring, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

C:

This statement concerns iSCSI network isolation and MPIO, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

Question 63

Before a server change is approved, the on-call engineer receives this incident report: A disk array enters a degraded state after one member fails, but its designated hot spare is smaller than the failed drive and never joins the rebuild. Which evidence would most directly establish the stated root-cause hypothesis? Select ONE best answer.

  1. Review workload I/O pattern, required fault tolerance, array health, usable capacity and rebuild time estimates.
  2. Declare an array healthy as soon as a replacement disk's activity light turns on.
  3. Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters.
  4. Inspect initiator sessions, target portals, VLAN paths, MTU agreement, switch queue drops and MPIO status.

Explanation

Correct Answer

C:

These observations investigate the exact Hot spare eligibility and rebuild supervision failure rather than unrelated components. Incident: A disk array enters a degraded state after one member fails, but its designated hot spare is smaller than the failed drive and never joins the rebuild.

Incorrect Answers

A:

For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. This statement concerns RAID fault tolerance versus performance, a different Server+ technical control.

B:

An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. This is the unsafe shortcut in the Hot spare eligibility and rebuild supervision scenario, not a justified remediation or diagnostic.

D:

For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters.

Question 64

After the team implements a targeted remediation for Hot spare eligibility and rebuild supervision, the original incident was: A disk array enters a degraded state after one member fails, but its designated hot spare is smaller than the failed drive and never joins the rebuild. Which acceptance criterion would best demonstrate a durable and safe resolution? Select ONE best answer.

  1. Critical spare parts and tested replacement procedures are available, with sensor warnings resolved before failure.
  2. Devices remain within endurance, temperature and spare-capacity guidance and replacements occur before service-impacting failures.
  3. The correct mounted filesystem reflects the new usable capacity without data loss and application writes succeed.
  4. The rebuild completes without new errors and the controller reports all expected redundancy restored.

Explanation

Correct Answer

D:

An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

Incorrect Answers

A:

This statement concerns Preventive hardware maintenance and spares, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

B:

This statement concerns NVMe endurance and capacity monitoring, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair.

C:

This statement concerns Filesystem growth after LUN expansion, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair.

Question 65

A change board is planning a verified response to this server event: A disk array enters a degraded state after one member fails, but its designated hot spare is smaller than the failed drive and never joins the rebuild. For the Hot spare eligibility and rebuild supervision issue, which response elements belong in the approved plan? Select ONE best answer.

  1. Consult the service manual, maintenance ticket, component status and grounding/ESD work area before removal.
  2. Use dedicated or appropriately isolated iSCSI paths with supported MPIO, correct initiator/target configuration and measured QoS.
  3. Declare an array healthy as soon as a replacement disk's activity light turns on.
  4. Provide compatible spare capacity and interface, replace the failed member, monitor the rebuild and verify array redundancy after completion. Then validate the change by confirming: The rebuild completes without new errors and the controller reports all expected redundancy restored.

Explanation

Correct Answer

D:

An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. The proposed change and outcome assessment work together for Hot spare eligibility and rebuild supervision.

Incorrect Answers

A:

This statement concerns ESD and hot-swap replacement procedure, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

B:

That option would use dedicated or appropriately isolated iSCSI paths with supported MPIO, correct initiator/target configuration and measured QoS, but it addresses a different concern. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

C:

This is the unsafe shortcut in the Hot spare eligibility and rebuild supervision scenario, not a justified remediation or diagnostic. Incident: A disk array enters a degraded state after one member fails, but its designated hot spare is smaller than the failed drive and never joins the rebuild.

Question 66

A server administrator is investigating a server issue involving hot spare eligibility and rebuild supervision: An operations team swaps a failed RAID member and assumes protection is restored before the controller completes rebuild and consistency checks. The change must address the documented fault without creating unrelated risk. Which corrective action is most appropriate? Select ONE best answer.

  1. Match the NIC, switch port, transceiver, cable medium and speed/duplex capability to the supported link standard.
  2. Declare an array healthy as soon as a replacement disk's activity light turns on.
  3. Provide compatible spare capacity and interface, replace the failed member, monitor the rebuild and verify array redundancy after completion.
  4. Check component hot-swap support, follow power isolation requirements and use approved ESD handling procedures.

Explanation

Correct Answer

C:

An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

Incorrect Answers

A:

That option would match the NIC, switch port, transceiver, cable medium and speed/duplex capability to the supported link standard, but it addresses a different concern. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

B:

This is the unsafe shortcut in the Hot spare eligibility and rebuild supervision scenario, not a justified remediation or diagnostic. Incident: An operations team swaps a failed RAID member and assumes protection is restored before the controller completes rebuild and consistency checks.

D:

That option would check component hot-swap support, follow power isolation requirements and use approved ESD handling procedures, but it addresses a different concern. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

Question 67

While reviewing the CompTIA Server+ administration incident, a technician learns: An operations team swaps a failed RAID member and assumes protection is restored before the controller completes rebuild and consistency checks. Which principle most directly explains how to address the described issue safely? Select ONE best answer.

  1. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.
  2. Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.
  3. SAN high availability requires correctly presented LUNs over multiple independent usable fabric paths, not redundant cables alone.
  4. Serviceable components differ in whether live replacement is safe, while electrostatic discharge can damage electronics even when mains power is removed.

Explanation

Correct Answer

A:

The acceptance test is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

Incorrect Answers

B:

This statement concerns NIC media and transceiver compatibility, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

C:

This statement concerns Fibre Channel SAN zoning and multipath, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

D:

This statement concerns ESD and hot-swap replacement procedure, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

Question 68

Before a server change is approved, the on-call engineer receives this incident report: An operations team swaps a failed RAID member and assumes protection is restored before the controller completes rebuild and consistency checks. Which evidence would most directly establish the stated root-cause hypothesis? Select ONE best answer.

  1. Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters.
  2. Inspect initiator sessions, target portals, VLAN paths, MTU agreement, switch queue drops and MPIO status.
  3. Declare an array healthy as soon as a replacement disk's activity light turns on.
  4. Check HBA WWPNs, zone membership, array masking, fabric logins and host multipath path states.

Explanation

Correct Answer

A:

These observations investigate the exact Hot spare eligibility and rebuild supervision failure rather than unrelated components. Incident: An operations team swaps a failed RAID member and assumes protection is restored before the controller completes rebuild and consistency checks.

Incorrect Answers

B:

For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

C:

An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

D:

For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. This statement concerns Fibre Channel SAN zoning and multipath, a different Server+ technical control.

Question 69

After the team implements a targeted remediation for Hot spare eligibility and rebuild supervision, the original incident was: An operations team swaps a failed RAID member and assumes protection is restored before the controller completes rebuild and consistency checks. Which acceptance criterion would best demonstrate a durable and safe resolution? Select ONE best answer.

  1. The selected array meets latency and capacity targets and remains accessible during the specified supported drive failure.
  2. The correct mounted filesystem reflects the new usable capacity without data loss and application writes succeed.
  3. The rebuild completes without new errors and the controller reports all expected redundancy restored.
  4. The component is replaced per approved procedure and POST or hardware diagnostics show normal health.

Explanation

Correct Answer

C:

An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. This evidence tests whether the original Hot spare eligibility and rebuild supervision weakness has been corrected under realistic conditions.

Incorrect Answers

A:

This statement concerns RAID fault tolerance versus performance, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

B:

This statement concerns Filesystem growth after LUN expansion, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A targeted investigation checks: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters. The desired recovery condition is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

D:

This statement concerns ESD and hot-swap replacement procedure, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair.

Question 70

A change board is planning a verified response to this server event: An operations team swaps a failed RAID member and assumes protection is restored before the controller completes rebuild and consistency checks. For the Hot spare eligibility and rebuild supervision issue, which response elements belong in the approved plan? Select TWO answers.

  1. Configure consistent WWPN zoning and LUN masking on independent fabrics, then enable supported host multipath policies.
  2. The correct mounted filesystem reflects the new usable capacity without data loss and application writes succeed.
  3. Provide compatible spare capacity and interface, replace the failed member, monitor the rebuild and verify array redundancy after completion.
  4. Declare an array healthy as soon as a replacement disk's activity light turns on.
  5. Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters.

Explanation

Correct Answer

C:

An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it. A successful outcome is: The rebuild completes without new errors and the controller reports all expected redundancy restored.

E:

These observations investigate the exact Hot spare eligibility and rebuild supervision failure rather than unrelated components. The expected technical relationship is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

Incorrect Answers

A:

That option would configure consistent WWPN zoning and LUN masking on independent fabrics, then enable supported host multipath policies, but it addresses a different concern. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

B:

This statement concerns Filesystem growth after LUN expansion, a different Server+ technical control. It does not directly address the reported Hot spare eligibility and rebuild supervision fault or prove its repair. For this incident, the relevant principle is: An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

D:

This is the unsafe shortcut in the Hot spare eligibility and rebuild supervision scenario, not a justified remediation or diagnostic. Discriminate using: Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters.

CompTIA Server+ Certification Exam (SK0-005) Practice Tests