cert
cert-1
cert-2

Pass CompTIA SK0-005 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
SK0-005 Exam - Verified By Experts
SK0-005 Premium Bundle
$29.98

SK0-005 Premium Bundle

$79.99
$109.97
  • Premium File 617 Questions & Answers. Last update: Nov 13, 2026
  • Training Course 139 Video Lectures
  • Study Guide 533 Pages
 
$109.97
$79.99
accept 21 downloads in last 7 days
block-screenshots
Purchase CompTIA SK0-005 Exam Training Products Individually
CompTIA SK0-005 Premium File
Premium File 617 Q&A
$76.99$69.99
CompTIA SK0-005 Video Training Course
Training Course 139 Lectures
$21.99 $19.99
CompTIA SK0-005 PDF Study Guide
Study Guide 533 Pages
$21.99 $19.99
CompTIA SK0-005 Practice Test 5

Question 40

A change board is planning a verified response to this server event: A server shipment arrives with BMC firmware and IPMI enabled, but technicians plan to leave remote management on the production subnet during deployment. For the Out-of-band management network issue, which response elements belong in the approved plan? Select TWO answers.

  1. The chassis is secured on compatible rails below rack capacity and sustained inlet and exhaust temperatures meet vendor limits.
  2. Place BMC access on an isolated management network, change default credentials, restrict administrator access and maintain supported firmware.
  3. Select enterprise SSD endurance for the expected write volume and monitor NVMe health, utilization and replacement thresholds.
  4. Expose the factory-configured BMC to general users because the operating system firewall is enabled.
  5. Inventory BMC firmware and accounts, scan exposed management interfaces and review management VLAN ACLs.

Explanation

Correct Answer

B:

A successful outcome is: Only authorized administrators can reach and authenticate to the updated BMC over the isolated path. This is the appropriate targeted correction for Out-of-band management network.

E:

Confirm remediation through: Only authorized administrators can reach and authenticate to the updated BMC over the isolated path. The expected technical relationship is: Out-of-band controllers are privileged hardware management interfaces and need independent network and identity protections.

Incorrect Answers

A:

For this incident, the relevant principle is: Out-of-band controllers are privileged hardware management interfaces and need independent network and identity protections. This statement concerns Rack weight, rail compatibility and airflow, a different Server+ technical control.

C:

A targeted investigation checks: Inventory BMC firmware and accounts, scan exposed management interfaces and review management VLAN ACLs.

D:

Out-of-band controllers are privileged hardware management interfaces and need independent network and identity protections.

Question 41

A server administrator is investigating a server issue involving nic media and transceiver compatibility: A new 25-GbE adapter shows no link after an engineer inserts an unsupported optical module and uses the wrong fiber standard. The change must address the documented fault without creating unrelated risk. Which corrective action is most appropriate? Select ONE best answer.

  1. Match the NIC, switch port, transceiver, cable medium and speed/duplex capability to the supported link standard.
  2. Check the rack's weight rating, supported rails, front-to-back clearance and cold/hot aisle arrangement; mount heavier equipment low and preserve unobstructed cooling.
  3. Connect redundant PSUs to independently protected PDU and UPS paths where available; size each path to carry the required load.
  4. Force higher interface speed in software without checking optics, cable and switch capability.

Explanation

Correct Answer

A:

Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A successful outcome is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Incorrect Answers

B:

That option would check the rack's weight rating, supported rails, front-to-back clearance and cold/hot aisle arrangement; mount heavier equipment low and preserve unobstructed cooling, but it addresses a different concern. Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.

C:

This statement concerns Dual power supply fault domains, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

D:

This is the unsafe shortcut in the NIC media and transceiver compatibility scenario, not a justified remediation or diagnostic. Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.

Question 42

While reviewing the CompTIA Server+ administration incident, a technician learns: A new 25-GbE adapter shows no link after an engineer inserts an unsupported optical module and uses the wrong fiber standard. Which principle most directly explains how to address the described issue safely? Select ONE best answer.

  1. Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.
  2. Block-device capacity, partition or logical-volume capacity and filesystem capacity are separate layers that must be reconciled.
  3. Out-of-band controllers are privileged hardware management interfaces and need independent network and identity protections.
  4. Memory configuration depends on CPU/socket population and validated channel topology, not only DIMM physical fit or total gigabytes.

Explanation

Correct Answer

A:

The acceptance test is: The port establishes the planned supported link speed with stable counters and no rising physical errors. This is the controlling principle for the reported NIC media and transceiver compatibility incident.

Incorrect Answers

B:

This statement concerns Filesystem growth after LUN expansion, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

C:

This statement concerns Out-of-band management network, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

D:

This statement concerns CPU memory compatibility and population, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Question 43

Before a server change is approved, the on-call engineer receives this incident report: A new 25-GbE adapter shows no link after an engineer inserts an unsupported optical module and uses the wrong fiber standard. Which evidence would most directly establish the stated root-cause hypothesis? Select ONE best answer.

  1. Inventory BMC firmware and accounts, scan exposed management interfaces and review management VLAN ACLs.
  2. Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed.
  3. Review chassis and rack load documents, weight distribution, rail part numbers, inlet temperature and actual front/rear clearances.
  4. Force higher interface speed in software without checking optics, cable and switch capability.

Explanation

Correct Answer

B:

These observations investigate the exact NIC media and transceiver compatibility failure rather than unrelated components. The expected technical relationship is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.

Incorrect Answers

A:

For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed.

C:

For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. This statement concerns Rack weight, rail compatibility and airflow, a different Server+ technical control.

D:

This is the unsafe shortcut in the NIC media and transceiver compatibility scenario, not a justified remediation or diagnostic. Discriminate using: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed.

Question 44

After the team implements a targeted remediation for NIC media and transceiver compatibility, the original incident was: A new 25-GbE adapter shows no link after an engineer inserts an unsupported optical module and uses the wrong fiber standard. Which acceptance criterion would best demonstrate a durable and safe resolution? Select ONE best answer.

  1. A planned single-path outage leaves the server powered without overloading the remaining path.
  2. The port establishes the planned supported link speed with stable counters and no rising physical errors.
  3. Firmware reports the expected usable capacity and approved speed, with balanced populated channels and no training errors.
  4. Both planned storage paths are available and storage latency remains within limits during controlled network failover.

Explanation

Correct Answer

B:

Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. Incident: A new 25-GbE adapter shows no link after an engineer inserts an unsupported optical module and uses the wrong fiber standard.

Incorrect Answers

A:

This statement concerns Dual power supply fault domains, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair.

C:

This statement concerns CPU memory compatibility and population, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair.

D:

This statement concerns iSCSI network isolation and MPIO, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Question 45

A change board is planning a verified response to this server event: A new 25-GbE adapter shows no link after an engineer inserts an unsupported optical module and uses the wrong fiber standard. For the NIC media and transceiver compatibility issue, which response elements belong in the approved plan? Select ONE best answer.

  1. Place BMC access on an isolated management network, change default credentials, restrict administrator access and maintain supported firmware.
  2. Force higher interface speed in software without checking optics, cable and switch capability.
  3. Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters.
  4. Match the NIC, switch port, transceiver, cable medium and speed/duplex capability to the supported link standard. Then validate the change by confirming: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Explanation

Correct Answer

D:

Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. This avoids the unsafe shortcut: Force higher interface speed in software without checking optics, cable and switch capability.

Incorrect Answers

A:

This statement concerns Out-of-band management network, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair.

B:

This is the unsafe shortcut in the NIC media and transceiver compatibility scenario, not a justified remediation or diagnostic. Incident: A new 25-GbE adapter shows no link after an engineer inserts an unsupported optical module and uses the wrong fiber standard.

C:

This statement concerns Hot spare eligibility and rebuild supervision, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Question 46

A server administrator is investigating a server issue involving nic media and transceiver compatibility: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode. The change must address the documented fault without creating unrelated risk. Which corrective action is most appropriate? Select ONE best answer.

  1. Select enterprise SSD endurance for the expected write volume and monitor NVMe health, utilization and replacement thresholds.
  2. Force higher interface speed in software without checking optics, cable and switch capability.
  3. Use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks.
  4. Match the NIC, switch port, transceiver, cable medium and speed/duplex capability to the supported link standard.

Explanation

Correct Answer

D:

Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. For this case, A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode.

Incorrect Answers

A:

That option would select enterprise SSD endurance for the expected write volume and monitor NVMe health, utilization and replacement thresholds, but it addresses a different concern. Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.

B:

This is the unsafe shortcut in the NIC media and transceiver compatibility scenario, not a justified remediation or diagnostic. Incident: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode.

C:

That option would use lifecycle and alert data to schedule preventive maintenance, stock qualified critical spares and document replacement runbooks, but it addresses a different concern. Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.

Question 47

While reviewing the CompTIA Server+ administration incident, a technician learns: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode. Which principle most directly explains how to address the described issue safely? Select ONE best answer.

  1. Flash storage performance and life depend on workload write intensity, remaining spare blocks and device health telemetry.
  2. Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.
  3. Preventive maintenance reduces recoverable downtime by detecting degrading components and planning compatible replacements.
  4. An array may remain vulnerable while degraded or rebuilding; a spare is useful only if the controller can use it.

Explanation

Correct Answer

B:

The acceptance test is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Incorrect Answers

A:

This statement concerns NVMe endurance and capacity monitoring, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

C:

This statement concerns Preventive hardware maintenance and spares, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

D:

This statement concerns Hot spare eligibility and rebuild supervision, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Question 48

Before a server change is approved, the on-call engineer receives this incident report: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode. Which evidence would most directly establish the stated root-cause hypothesis? Select ONE best answer.

  1. Force higher interface speed in software without checking optics, cable and switch capability.
  2. Examine controller event logs, physical drive size/type, spare assignment, rebuild progress and media-error counters.
  3. Inventory BMC firmware and accounts, scan exposed management interfaces and review management VLAN ACLs.
  4. Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed.

Explanation

Correct Answer

D:

These observations investigate the exact NIC media and transceiver compatibility failure rather than unrelated components. Incident: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode.

Incorrect Answers

A:

Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.

B:

For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. Incident: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode.

C:

For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. This statement concerns Out-of-band management network, a different Server+ technical control.

Question 49

After the team implements a targeted remediation for NIC media and transceiver compatibility, the original incident was: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode. Which acceptance criterion would best demonstrate a durable and safe resolution? Select ONE best answer.

  1. Firmware reports the expected usable capacity and approved speed, with balanced populated channels and no training errors.
  2. Devices remain within endurance, temperature and spare-capacity guidance and replacements occur before service-impacting failures.
  3. A planned single-path outage leaves the server powered without overloading the remaining path.
  4. The port establishes the planned supported link speed with stable counters and no rising physical errors.

Explanation

Correct Answer

D:

Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. Incident: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode.

Incorrect Answers

A:

This statement concerns CPU memory compatibility and population, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

B:

This statement concerns NVMe endurance and capacity monitoring, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair.

C:

This statement concerns Dual power supply fault domains, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. A targeted investigation checks: Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed. The desired recovery condition is: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Question 50

A change board is planning a verified response to this server event: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode. For the NIC media and transceiver compatibility issue, which response elements belong in the approved plan? Select TWO answers.

  1. Force higher interface speed in software without checking optics, cable and switch capability.
  2. Match the NIC, switch port, transceiver, cable medium and speed/duplex capability to the supported link standard.
  3. Check NIC and switch support lists, module part IDs, cable labels, optical power, port errors and negotiated speed.
  4. Firmware reports the expected usable capacity and approved speed, with balanced populated channels and no training errors.
  5. Provide compatible spare capacity and interface, replace the failed member, monitor the rebuild and verify array redundancy after completion.

Explanation

Correct Answer

B:

Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics. This is the appropriate targeted correction for NIC media and transceiver compatibility.

C:

These observations investigate the exact NIC media and transceiver compatibility failure rather than unrelated components. Confirm remediation through: The port establishes the planned supported link speed with stable counters and no rising physical errors.

Incorrect Answers

A:

Incident: A storage server's copper NIC negotiates only 1 Gb/s because the cable category and switch port do not support the requested 10 Gb/s mode.

D:

This statement concerns CPU memory compatibility and population, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair. For this incident, the relevant principle is: Physical Ethernet links require interoperable media and interfaces; configuring an IP address cannot fix incompatible layer-one optics.

E:

This statement concerns Hot spare eligibility and rebuild supervision, a different Server+ technical control. It does not directly address the reported NIC media and transceiver compatibility fault or prove its repair.