CompTIA N10-009 Practice Test 68
Question 670
A network port is error-disabled after a user attached a small unmanaged switch with several devices. A colleague instead suggests: Disable all port security across the campus to avoid this incident. Which finding MOST specifically explains why that suggestion is unsuitable?
- Legitimate fan-out needs a scoped policy exception instead of globally disabling controls.
- Security violations can intentionally disable ports to contain unexpected endpoint fan-out.
- Firewall policy cannot correct optical signal attenuation.
- Broadly removing safeguards creates avoidable admission risk.
Explanation
Correct Answer
D:Broadly removing safeguards creates avoidable admission risk. This flaw directly concerns the proposed action: Disable all port security across the campus to avoid this incident.
Incorrect Answers
A:This rationale belongs to a later changed condition: The company officially authorizes a multi-device phone and PC arrangement.
B:This explains why the recommended control works: Identify the port-security trigger, remove unauthorized devices and restore under policy.
C:This flaw concerns a different case in objective 5.2: A new optic shows low receive light power and a rising bit error rate despite matching nominal speed. The current rejected proposal is: Disable all port security across the campus to avoid this incident.
Question 671
A network port is error-disabled after a user attached a small unmanaged switch with several devices. After applying the solution 'Identify the port-security trigger, remove unauthorized devices and restore under policy.', which observation MOST directly proves that the requirement was met?
- Approval is recorded for 'Identify the port-security trigger, remove unauthorized devices and restore under policy.' but no operational validation is performed.
- The approved device reconnects and no new port-security events appear.
- Cleaning or replacing the bad segment restores receive power and stable frames.
- After correcting interface settings, runt and collision counters stabilize.
Explanation
Correct Answer
B:The approved device reconnects and no new port-security events appear. It tests the intended outcome because security violations can intentionally disable ports to contain unexpected endpoint fan-out.
Incorrect Answers
A:Approval alone does not demonstrate operating effectiveness. The missing direct test is: The approved device reconnects and no new port-security events appear.
C:This observation is for a different condition: A new optic shows low receive light power and a rising bit error rate despite matching nominal speed. It does not directly test the target outcome: A network port is error-disabled after a user attached a small unmanaged switch with several devices.
D:This test addresses a separate problem: An old cable run displays frequent runts and duplex-related collision counters on a legacy shared segment.
Question 672
The original case was: A network port is error-disabled after a user attached a small unmanaged switch with several devices. The requirement then changes: The company officially authorizes a multi-device phone and PC arrangement. Which revised action BEST meets this new condition?
- Configure supported voice/data policy and approved MAC limits.
- Disable all port security across the campus to avoid this incident.
- The approved device reconnects and no new port-security events appear.
- Identify the port-security trigger, remove unauthorized devices and restore under policy.
Explanation
Correct Answer
A:Legitimate fan-out needs a scoped policy exception instead of globally disabling controls. The revised requirement is: The company officially authorizes a multi-device phone and PC arrangement. The appropriate action is: Configure supported voice/data policy and approved MAC limits.
Incorrect Answers
B:Broadly removing safeguards creates avoidable admission risk. It remains inappropriate in the revised context.
C:The approved device reconnects and no new port-security events appear. The current requirement is: The company officially authorizes a multi-device phone and PC arrangement.
D:This is the original control. Security violations can intentionally disable ports to contain unexpected endpoint fan-out. It does not directly satisfy the revised requirement: The company officially authorizes a multi-device phone and PC arrangement.
Question 673
Packets drop under high load because an uplink is saturated but interface CRC counters stay clean. Which action MOST directly meets the stated networking requirement?
- Investigate physical signal, connectors and media quality.
- Verify duplex negotiation and investigate malformed or undersized Ethernet frames.
- Replace every fiber transceiver solely because packet loss is observed.
- Measure utilization, discards and queue depth to confirm congestion rather than cable corruption.
Explanation
Correct Answer
D:Drops with clean physical errors can indicate buffer or queue pressure. This specifically resolves: Packets drop under high load because an uplink is saturated but interface CRC counters stay clean.
Incorrect Answers
A:This action responds to a later condition: A different port shows rising CRC errors even at low utilization. CRC errors point more directly to corrupted physical frames.
B:This addresses another problem in objective 5.2: An old cable run displays frequent runts and duplex-related collision counters on a legacy shared segment.
C:Packet loss is not automatically evidence of optical failure. The suggested approach is: Replace every fiber transceiver solely because packet loss is observed.
Question 674
Packets drop under high load because an uplink is saturated but interface CRC counters stay clean. A colleague instead suggests: Replace every fiber transceiver solely because packet loss is observed. Which finding MOST specifically explains why that suggestion is unsuitable?
- Route preference does not correct Layer 2 frame formation.
- Packet loss is not automatically evidence of optical failure.
- Drops with clean physical errors can indicate buffer or queue pressure.
- CRC errors point more directly to corrupted physical frames.
Explanation
Correct Answer
B:Packet loss is not automatically evidence of optical failure. This flaw directly concerns the proposed action: Replace every fiber transceiver solely because packet loss is observed.
Incorrect Answers
A:This flaw concerns a different case in objective 5.2: An old cable run displays frequent runts and duplex-related collision counters on a legacy shared segment. The current rejected proposal is: Replace every fiber transceiver solely because packet loss is observed.
C:This explains why the recommended control works: Measure utilization, discards and queue depth to confirm congestion rather than cable corruption.
D:This rationale belongs to a later changed condition: A different port shows rising CRC errors even at low utilization.
Question 675
Packets drop under high load because an uplink is saturated but interface CRC counters stay clean. Which TWO entries together specify the appropriate corrective measure AND the strongest direct evidence that it works? (Select TWO.)
- Replace every fiber transceiver solely because packet loss is observed.
- Traffic shaping or capacity tests reduce queue drops under equivalent demand.
- Investigate physical signal, connectors and media quality.
- Verify duplex negotiation and investigate malformed or undersized Ethernet frames.
- Measure utilization, discards and queue depth to confirm congestion rather than cable corruption.
Explanation
Correct Answers
B:Correct verification. Traffic shaping or capacity tests reduce queue drops under equivalent demand. This demonstrates the outcome expected from: Measure utilization, discards and queue depth to confirm congestion rather than cable corruption.
E:Correct control. Drops with clean physical errors can indicate buffer or queue pressure. It addresses the present requirement: Packets drop under high load because an uplink is saturated but interface CRC counters stay clean.
Incorrect Answers
A:Incorrect control. Packet loss is not automatically evidence of optical failure. The inappropriate proposal is: Replace every fiber transceiver solely because packet loss is observed.
C:This is a response to a different later requirement: A different port shows rising CRC errors even at low utilization. CRC errors point more directly to corrupted physical frames. It is not the original control-and-evidence pair.
D:This control fits another scenario in objective 5.2: An old cable run displays frequent runts and duplex-related collision counters on a legacy shared segment. It does not directly verify or implement the present issue.
Question 676
The original case was: Packets drop under high load because an uplink is saturated but interface CRC counters stay clean. The requirement then changes: A different port shows rising CRC errors even at low utilization. Which revised action BEST meets this new condition?
- Investigate physical signal, connectors and media quality.
- Measure utilization, discards and queue depth to confirm congestion rather than cable corruption.
- Traffic shaping or capacity tests reduce queue drops under equivalent demand.
- Replace every fiber transceiver solely because packet loss is observed.
Explanation
Correct Answer
A:CRC errors point more directly to corrupted physical frames. The revised requirement is: A different port shows rising CRC errors even at low utilization. The appropriate action is: Investigate physical signal, connectors and media quality.
Incorrect Answers
B:This is the original control. Drops with clean physical errors can indicate buffer or queue pressure. It does not directly satisfy the revised requirement: A different port shows rising CRC errors even at low utilization.
C:Traffic shaping or capacity tests reduce queue drops under equivalent demand. The current requirement is: A different port shows rising CRC errors even at low utilization.
D:Packet loss is not automatically evidence of optical failure. It remains inappropriate in the revised context.
Question 677
A new optic shows low receive light power and a rising bit error rate despite matching nominal speed. Which action MOST directly meets the stated networking requirement?
- Test the cable pinout and pair continuity and replace defective termination.
- Measure optical power and inspect connector cleanliness, bends and link distance.
- Check supported receiver power range and use appropriate optics or attenuation.
- Modify an application firewall rule to increase incoming photons.
Explanation
Correct Answer
B:Optical loss and low power can cause errors without total link failure. This specifically resolves: A new optic shows low receive light power and a rising bit error rate despite matching nominal speed.
Incorrect Answers
A:This addresses another problem in objective 5.2: A new copper patch cable links at 100 Mbps even though both endpoints support gigabit and another cable works.
C:This action responds to a later condition: A replacement optic is overdriving a very short fiber segment. Excess optical power can also exceed transceiver operating limits.
D:Firewall policy cannot correct optical signal attenuation. The suggested approach is: Modify an application firewall rule to increase incoming photons.
Question 678
A new optic shows low receive light power and a rising bit error rate despite matching nominal speed. A colleague instead suggests: Modify an application firewall rule to increase incoming photons. Which finding MOST specifically explains why that suggestion is unsuitable?
- Firewall policy cannot correct optical signal attenuation.
- Optical loss and low power can cause errors without total link failure.
- Excess optical power can also exceed transceiver operating limits.
- DNS cache settings do not alter twisted-pair signal integrity.
Explanation
Correct Answer
A:Firewall policy cannot correct optical signal attenuation. This flaw directly concerns the proposed action: Modify an application firewall rule to increase incoming photons.
Incorrect Answers
B:This explains why the recommended control works: Measure optical power and inspect connector cleanliness, bends and link distance.
C:This rationale belongs to a later changed condition: A replacement optic is overdriving a very short fiber segment.
D:This flaw concerns a different case in objective 5.2: A new copper patch cable links at 100 Mbps even though both endpoints support gigabit and another cable works. The current rejected proposal is: Modify an application firewall rule to increase incoming photons.
Question 679
A new optic shows low receive light power and a rising bit error rate despite matching nominal speed. After applying the solution 'Measure optical power and inspect connector cleanliness, bends and link distance.', which observation MOST directly proves that the requirement was met?
- Approval is recorded for 'Measure optical power and inspect connector cleanliness, bends and link distance.' but no operational validation is performed.
- Cleaning or replacing the bad segment restores receive power and stable frames.
- A certified replacement supports gigabit with clean error counters.
- Compatible modules establish the intended rate with acceptable receive power.
Explanation
Correct Answer
B:Cleaning or replacing the bad segment restores receive power and stable frames. It tests the intended outcome because optical loss and low power can cause errors without total link failure.
Incorrect Answers
A:The missing direct test is: Cleaning or replacing the bad segment restores receive power and stable frames.
C:This observation is for a different condition: A new copper patch cable links at 100 Mbps even though both endpoints support gigabit and another cable works. It does not directly test the target outcome: A new optic shows low receive light power and a rising bit error rate despite matching nominal speed.
D:This test addresses a separate problem: A fiber uplink stays down after technicians install a transceiver rated for the wrong fiber type.
Question 680
The original case was: A new optic shows low receive light power and a rising bit error rate despite matching nominal speed. The requirement then changes: A replacement optic is overdriving a very short fiber segment. Which revised action BEST meets this new condition?
- Modify an application firewall rule to increase incoming photons.
- Check supported receiver power range and use appropriate optics or attenuation.
- Measure optical power and inspect connector cleanliness, bends and link distance.
- Cleaning or replacing the bad segment restores receive power and stable frames.
Explanation
Correct Answer
B:Excess optical power can also exceed transceiver operating limits. The revised requirement is: A replacement optic is overdriving a very short fiber segment. The appropriate action is: Check supported receiver power range and use appropriate optics or attenuation.
Incorrect Answers
A:Firewall policy cannot correct optical signal attenuation. It remains inappropriate in the revised context.
C:This is the original control. Optical loss and low power can cause errors without total link failure. It does not directly satisfy the revised requirement: A replacement optic is overdriving a very short fiber segment.
D:Cleaning or replacing the bad segment restores receive power and stable frames. The current requirement is: A replacement optic is overdriving a very short fiber segment.