CompTIA N10-009 Practice Test 66
Question 650
A fiber uplink stays down after technicians install a transceiver rated for the wrong fiber type. Which TWO entries together specify the appropriate corrective measure AND the strongest direct evidence that it works? (Select TWO.)
- Inspect and clean connector ferrules and retest optical loss.
- Match optical module specification, wavelength and fiber class at both ends.
- Investigate electromagnetic interference and replace or reroute affected cable with suitable shielding.
- Reset DHCP leases to repair an incompatible optical wavelength.
- Compatible modules establish the intended rate with acceptable receive power.
Explanation
Correct Answers
B:Correct control. Optic and fiber mismatch can exceed loss budgets or use incompatible standards. It addresses the present requirement: A fiber uplink stays down after technicians install a transceiver rated for the wrong fiber type.
E:Correct verification. Compatible modules establish the intended rate with acceptable receive power. This demonstrates the outcome expected from: Match optical module specification, wavelength and fiber class at both ends.
Incorrect Answers
A:This is a response to a different later requirement: Link comes up but optical errors remain high from dirty connectors. Contamination can degrade an otherwise compatible optical link. It is not the original control-and-evidence pair.
C:This control fits another scenario in objective 5.2: An Ethernet link shows rising CRC errors only when nearby industrial motors run. It does not directly verify or implement the present issue.
D:Incorrect control. Address leases cannot fix an absent optical link. The inappropriate proposal is: Reset DHCP leases to repair an incompatible optical wavelength.
Question 651
A fiber uplink stays down after technicians install a transceiver rated for the wrong fiber type. After applying the solution 'Match optical module specification, wavelength and fiber class at both ends.', which observation MOST directly proves that the requirement was met?
- Error rates fall when the cable is rerouted or protected from the noise source.
- Power diagnostics show stable watts and AP startup under the approved budget.
- Approval is recorded for 'Match optical module specification, wavelength and fiber class at both ends.' but no operational validation is performed.
- Compatible modules establish the intended rate with acceptable receive power.
Explanation
Correct Answer
D:Compatible modules establish the intended rate with acceptable receive power. It tests the intended outcome because optic and fiber mismatch can exceed loss budgets or use incompatible standards.
Incorrect Answers
A:This observation is for a different condition: An Ethernet link shows rising CRC errors only when nearby industrial motors run. It does not directly test the target outcome: A fiber uplink stays down after technicians install a transceiver rated for the wrong fiber type.
B:This test addresses a separate problem: PoE access points fail to power when a switch powers all attached devices simultaneously.
C:The missing direct test is: Compatible modules establish the intended rate with acceptable receive power.
Question 652
The original case was: A fiber uplink stays down after technicians install a transceiver rated for the wrong fiber type. The requirement then changes: Link comes up but optical errors remain high from dirty connectors. Which revised action BEST meets this new condition?
- Inspect and clean connector ferrules and retest optical loss.
- Match optical module specification, wavelength and fiber class at both ends.
- Compatible modules establish the intended rate with acceptable receive power.
- Reset DHCP leases to repair an incompatible optical wavelength.
Explanation
Correct Answer
A:Contamination can degrade an otherwise compatible optical link. The revised requirement is: Link comes up but optical errors remain high from dirty connectors. The appropriate action is: Inspect and clean connector ferrules and retest optical loss.
Incorrect Answers
B:This is the original control. Optic and fiber mismatch can exceed loss budgets or use incompatible standards. It does not directly satisfy the revised requirement: Link comes up but optical errors remain high from dirty connectors.
C:Compatible modules establish the intended rate with acceptable receive power. The current requirement is: Link comes up but optical errors remain high from dirty connectors.
D:This action was already unsuitable. Address leases cannot fix an absent optical link. It remains inappropriate in the revised context.
Question 653
A newly installed fiber pair has no link because transmit and receive strands are reversed at one patch panel. Which action MOST directly meets the stated networking requirement?
- Increase the VLAN database size to reverse optical light direction.
- Measure end-to-end optical loss and inspect bends or damaged connectors.
- Verify polarity and cross-connect the transmit and receive paths correctly.
- Review switch PoE budget and the power class or standard required by the devices.
Explanation
Correct Answer
C:Fiber duplex connections require proper TX-to-RX pairing. This specifically resolves: A newly installed fiber pair has no link because transmit and receive strands are reversed at one patch panel.
Incorrect Answers
A:Layer-2 VLAN configuration does not correct physical fiber polarity. The suggested approach is: Increase the VLAN database size to reverse optical light direction.
B:This action responds to a later condition: A subsequent fiber link has excessive attenuation with proper polarity. High insertion loss is a separate optical physical fault.
D:This addresses another problem in objective 5.2: PoE access points fail to power when a switch powers all attached devices simultaneously.
Question 654
A newly installed fiber pair has no link because transmit and receive strands are reversed at one patch panel. A colleague instead suggests: Increase the VLAN database size to reverse optical light direction. Which finding MOST specifically explains why that suggestion is unsuitable?
- Radio RF power settings do not increase PSE power budget.
- High insertion loss is a separate optical physical fault.
- Fiber duplex connections require proper TX-to-RX pairing.
- Layer-2 VLAN configuration does not correct physical fiber polarity.
Explanation
Correct Answer
D:Layer-2 VLAN configuration does not correct physical fiber polarity. This flaw directly concerns the proposed action: Increase the VLAN database size to reverse optical light direction.
Incorrect Answers
A:This flaw concerns a different case in objective 5.2: PoE access points fail to power when a switch powers all attached devices simultaneously. The current rejected proposal is: Increase the VLAN database size to reverse optical light direction.
B:This rationale belongs to a later changed condition: A subsequent fiber link has excessive attenuation with proper polarity.
C:This explains why the recommended control works: Verify polarity and cross-connect the transmit and receive paths correctly.
Question 655
A newly installed fiber pair has no link because transmit and receive strands are reversed at one patch panel. After applying the solution 'Verify polarity and cross-connect the transmit and receive paths correctly.', which observation MOST directly proves that the requirement was met?
- Optical light measurements and link status become healthy after polarity correction.
- Power diagnostics show stable watts and AP startup under the approved budget.
- Interface status transitions to up and the server exchanges expected frames.
- Approval is recorded for 'Verify polarity and cross-connect the transmit and receive paths correctly.' but no operational validation is performed.
Explanation
Correct Answer
A:Optical light measurements and link status become healthy after polarity correction. It tests the intended outcome because fiber duplex connections require proper tx-to-rx pairing.
Incorrect Answers
B:This observation is for a different condition: PoE access points fail to power when a switch powers all attached devices simultaneously. It does not directly test the target outcome: A newly installed fiber pair has no link because transmit and receive strands are reversed at one patch panel.
C:This test addresses a separate problem: A switchport is administratively disabled and the attached server cannot establish link.
D:The missing direct test is: Optical light measurements and link status become healthy after polarity correction.
Question 656
The original case was: A newly installed fiber pair has no link because transmit and receive strands are reversed at one patch panel. The requirement then changes: A subsequent fiber link has excessive attenuation with proper polarity. Which revised action BEST meets this new condition?
- Optical light measurements and link status become healthy after polarity correction.
- Verify polarity and cross-connect the transmit and receive paths correctly.
- Increase the VLAN database size to reverse optical light direction.
- Measure end-to-end optical loss and inspect bends or damaged connectors.
Explanation
Correct Answer
D:High insertion loss is a separate optical physical fault. The revised requirement is: A subsequent fiber link has excessive attenuation with proper polarity. The appropriate action is: Measure end-to-end optical loss and inspect bends or damaged connectors.
Incorrect Answers
A:Optical light measurements and link status become healthy after polarity correction. The current requirement is: A subsequent fiber link has excessive attenuation with proper polarity.
B:This is the original control. Fiber duplex connections require proper TX-to-RX pairing. It does not directly satisfy the revised requirement: A subsequent fiber link has excessive attenuation with proper polarity.
C:Layer-2 VLAN configuration does not correct physical fiber polarity. It remains inappropriate in the revised context.
Question 657
An Ethernet link shows rising CRC errors only when nearby industrial motors run. Which action MOST directly meets the stated networking requirement?
- Increase DNS TTL to compensate for physical frame corruption.
- Enable the port under approved change control after validating intended connection.
- Choose appropriate fiber media and optics for electrical isolation.
- Investigate electromagnetic interference and replace or reroute affected cable with suitable shielding.
Explanation
Correct Answer
D:Electrical noise can corrupt copper transmission, causing CRC errors. This specifically resolves: An Ethernet link shows rising CRC errors only when nearby industrial motors run.
Incorrect Answers
A:Name caching does not eliminate copper interference. The suggested approach is: Increase DNS TTL to compensate for physical frame corruption.
B:This addresses another problem in objective 5.2: A switchport is administratively disabled and the attached server cannot establish link.
C:This action responds to a later condition: The company replaces the noisy copper uplink with long-distance fiber. Fiber transmission avoids the same copper EMI exposure.
Question 658
An Ethernet link shows rising CRC errors only when nearby industrial motors run. A colleague instead suggests: Increase DNS TTL to compensate for physical frame corruption. Which finding MOST specifically explains why that suggestion is unsuitable?
- Fiber transmission avoids the same copper EMI exposure.
- Name caching does not eliminate copper interference.
- Electrical noise can corrupt copper transmission, causing CRC errors.
- IP settings cannot enable an administratively disabled PHY.
Explanation
Correct Answer
B:Name caching does not eliminate copper interference. This flaw directly concerns the proposed action: Increase DNS TTL to compensate for physical frame corruption.
Incorrect Answers
A:This rationale belongs to a later changed condition: The company replaces the noisy copper uplink with long-distance fiber.
C:This explains why the recommended control works: Investigate electromagnetic interference and replace or reroute affected cable with suitable shielding.
D:This flaw concerns a different case in objective 5.2: A switchport is administratively disabled and the attached server cannot establish link. The current rejected proposal is: Increase DNS TTL to compensate for physical frame corruption.
Question 659
An Ethernet link shows rising CRC errors only when nearby industrial motors run. After applying the solution 'Investigate electromagnetic interference and replace or reroute affected cable with suitable shielding.', which observation MOST directly proves that the requirement was met?
- The approved device reconnects and no new port-security events appear.
- Approval is recorded for 'Investigate electromagnetic interference and replace or reroute affected cable with suitable shielding.' but no operational validation is performed.
- Error rates fall when the cable is rerouted or protected from the noise source.
- Interface status transitions to up and the server exchanges expected frames.
Explanation
Correct Answer
C:Error rates fall when the cable is rerouted or protected from the noise source. It tests the intended outcome because electrical noise can corrupt copper transmission, causing crc errors.
Incorrect Answers
A:This test addresses a separate problem: A network port is error-disabled after a user attached a small unmanaged switch with several devices.
B:The missing direct test is: Error rates fall when the cable is rerouted or protected from the noise source.
D:This observation is for a different condition: A switchport is administratively disabled and the attached server cannot establish link. It does not directly test the target outcome: An Ethernet link shows rising CRC errors only when nearby industrial motors run.
Question 660
The original case was: An Ethernet link shows rising CRC errors only when nearby industrial motors run. The requirement then changes: The company replaces the noisy copper uplink with long-distance fiber. Which revised action BEST meets this new condition?
- Investigate electromagnetic interference and replace or reroute affected cable with suitable shielding.
- Error rates fall when the cable is rerouted or protected from the noise source.
- Choose appropriate fiber media and optics for electrical isolation.
- Increase DNS TTL to compensate for physical frame corruption.
Explanation
Correct Answer
C:Fiber transmission avoids the same copper EMI exposure. The revised requirement is: The company replaces the noisy copper uplink with long-distance fiber. The appropriate action is: Choose appropriate fiber media and optics for electrical isolation.
Incorrect Answers
A:This is the original control. Electrical noise can corrupt copper transmission, causing CRC errors. It does not directly satisfy the revised requirement: The company replaces the noisy copper uplink with long-distance fiber.
B:Error rates fall when the cable is rerouted or protected from the noise source. The current requirement is: The company replaces the noisy copper uplink with long-distance fiber.
D:Name caching does not eliminate copper interference. It remains inappropriate in the revised context.