CompTIA 220-1201 Practice Test 71
Question 700
At Stonebridge Research, a technician working in small-office network service desk identifies this issue: A customer receives a fiber-to-the-premises service but attempts to connect the optical fiber directly to a DOCSIS cable modem. The supporting record states that the provider hands off optical PON through an optical network terminal. The desired outcome is to choose access equipment that terminates the actual carrier medium. The goal is to restore required function without creating a new security or safety problem. How should the solution first be tested on an approved spare or pilot system?
- Connect representative powered devices to a lab switch and monitor total power budget
- Test a lab Ethernet connection after a provisioned ONT, without altering optical connectors
- Test ping between subnets through an approved router after confirming local switching
- Query a known internal name on a test client with corrected DNS settings
Explanation
Correct Answer
B:
Test a lab Ethernet connection after a provisioned ONT, without altering optical connectors. It tests the proposed solution safely on an approved representative system. The relevant observation is that the provider hands off optical PON through an optical network terminal. The support goal is to choose access equipment that terminates the actual carrier medium; this pilot action specifically addresses ont versus cable modem access equipment without confusing a different subsystem.
Incorrect Answers
A:
Connect representative powered devices to a lab switch and monitor total power budget. This action is appropriate for poe switch power budget, normally when new IP cameras power off when all connected access points and phones start at once. Here the observed facts require ont versus cable modem access equipment instead.
C:
Test ping between subnets through an approved router after confirming local switching. This action is appropriate for router versus layer 2 switch forwarding, normally when two PCs on separate IPv4 subnets can communicate within their own LANs but not across subnets. Here the observed facts require ont versus cable modem access equipment instead.
D:
Query a known internal name on a test client with corrected DNS settings. This action is appropriate for dns resolution versus dhcp address assignment, normally when a workstation has a valid IPv4 address, gateway and lease but cannot reach services by hostname. Here the observed facts require ont versus cable modem access equipment instead.
Question 701
A support request at Monarch Pharmacy presents this problem: A gaming PC has fans and lights but fails POST after a second RAM stick was installed. The desired outcome is to diagnose a probable memory seating or module fault before swapping unrelated parts. User data and business service continuity must be preserved. What should support monitor to catch a recurrence of the same failure?
- Monitor outlet failures and repeated power interruptions
- Monitor new memory errors and recurrence after the chassis is moved
- Monitor new POST codes or display initialization failures after component changes
- Monitor fan RPM alerts, dust buildup and thermal throttling trends
Explanation
Correct Answer
B:
Monitor new memory errors and recurrence after the chassis is moved. It tracks recurrence of the specific failure mechanism over time. The relevant observation is that a gaming PC has fans and lights but fails POST after a second RAM stick was installed. The support goal is to diagnose a probable memory seating or module fault before swapping unrelated parts; this monitor action specifically addresses desktop memory fault preventing post without confusing a different subsystem.
Incorrect Answers
A:
Monitor outlet failures and repeated power interruptions. This action is appropriate for completely dead desktop power path, normally when a tower PC has no LEDs, fans, or POST activity after the user changed power outlets. Here the observed facts require desktop memory fault preventing post instead.
C:
Monitor new POST codes or display initialization failures after component changes. This action is appropriate for post beep code interpretation and expansion-card isolation, normally when a newly upgraded desktop beeps at startup and shows no BIOS screen. Here the observed facts require desktop memory fault preventing post instead.
D:
Monitor fan RPM alerts, dust buildup and thermal throttling trends. This action is appropriate for cpu overheat from failed fan, normally when a desktop shuts off only after several minutes of high CPU utilization. Here the observed facts require desktop memory fault preventing post instead.
Question 702
On a service ticket for Cedar Education, the team observes: A developer proposes a full Windows guest for each Linux microservice despite a supported container runtime. The desired outcome is to identify containers versus full operating-system VMs for application packaging. Any configuration change must be reversible and validated on a controlled test device. Which configuration or repair action best addresses the stated requirement?
- Use a Type 2 hosted hypervisor for a nonproduction guest on the existing OS
- Configure supported autoscaling rules with limits for traffic-driven elasticity
- Use a container image for the application and a VM where a separate guest OS is necessary
- Deploy a supported VDI solution with centrally hosted desktop sessions
Explanation
Correct Answer
C:
Use a container image for the application and a VM where a separate guest OS is necessary. It corrects the documented cause using the compatible technology and support constraints. The relevant observation is that a developer proposes a full Windows guest for each Linux microservice despite a supported container runtime. The support goal is to identify containers versus full operating-system VMs for application packaging; this design action specifically addresses container isolation versus full virtual machine without confusing a different subsystem.
Incorrect Answers
A:
Use a Type 2 hosted hypervisor for a nonproduction guest on the existing OS. That action is appropriate for hosted type 2 virtualization for testing, normally when a help desk engineer needs an isolated test operating system on an existing laptop. Here the observed facts require container isolation versus full virtual machine instead.
B:
Configure supported autoscaling rules with limits for traffic-driven elasticity. This action is appropriate for cloud elasticity versus fixed provisioning, normally when an online storefront sees traffic triple for two hours and then fall back to normal. Here the observed facts require container isolation versus full virtual machine instead.
D:
Deploy a supported VDI solution with centrally hosted desktop sessions. That action is appropriate for vdi versus local desktop processing, normally when a company wants centrally managed user desktops accessed from inexpensive endpoints. Here the observed facts require container isolation versus full virtual machine instead.
Question 703
During Seabright Supplies's end-user troubleshooting, the technician encounters this condition: A workstation appears dead after a cleaning crew switches off the power strip feeding it. The desired outcome is to isolate basic external power before replacing the motherboard. The technician must document observations separately from assumptions. What should the technician recommend as the corrective approach?
- Restore valid AC input or replace the confirmed faulty PSU only after external checks
- Reseat RAM with power disconnected and isolate modules using supported test slots
- Restore the intended voice and data VLAN configuration with appropriate scope
- Reseat or replace the confirmed graphics card rather than assuming every beep means bad RAM
Explanation
Correct Answer
A:
Restore valid AC input or replace the confirmed faulty PSU only after external checks. It corrects the documented cause using the compatible technology and support constraints. The relevant observation is that a workstation appears dead after a cleaning crew switches off the power strip feeding it. The support goal is to isolate basic external power before replacing the motherboard; this design action specifically addresses completely dead desktop power path without confusing a different subsystem.
Incorrect Answers
B:
Reseat RAM with power disconnected and isolate modules using supported test slots. That action is appropriate for desktop memory fault preventing post, normally when a desktop powers on but gives a repeating memory-related beep pattern and no display. Here the observed facts require completely dead desktop power path instead.
C:
Restore the intended voice and data VLAN configuration with appropriate scope. This action is appropriate for vlan mismatch causing one desk to lose access, normally when a desk phone and PC stop reaching their correct services after a switch port change. Here the observed facts require completely dead desktop power path instead.
D:
Reseat or replace the confirmed graphics card rather than assuming every beep means bad RAM. That action is appropriate for post beep code interpretation and expansion-card isolation, normally when a newly upgraded desktop beeps at startup and shows no BIOS screen. Here the observed facts require completely dead desktop power path instead.
Question 704
A support request at Bluefin Logistics presents this problem: A gaming PC has a motherboard with an AMD processor socket but an Intel CPU was ordered. The supporting record states that the processors require different sockets and platform firmware support. The desired outcome is to verify socket and chipset compatibility before installing a processor. The technician must document observations separately from assumptions. Which acceptance result best demonstrates the issue is resolved?
- Verify stable output and no PSU overload when rendering
- Verify CPU identity, temperature and stability under a controlled load
- Verify sustained workload temperatures stay within processor limits and throttling ceases
- Verify signed media boot and unsigned test boot is rejected by policy
Explanation
Correct Answer
B:
Verify CPU identity, temperature and stability under a controlled load. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that the processors require different sockets and platform firmware support. The support goal is to verify socket and chipset compatibility before installing a processor; this validate action specifically addresses cpu socket matching motherboard without confusing a different subsystem.
Incorrect Answers
A:
Verify stable output and no PSU overload when rendering. This action is appropriate for pcie slot and gpu power constraints, normally when a designer's PC has an available physical PCIe x16 slot but an upgraded graphics card fails under load. Here the observed facts require cpu socket matching motherboard instead.
C:
Verify sustained workload temperatures stay within processor limits and throttling ceases. That action is appropriate for cpu heatsink thermal interface, normally when a workstation reaches a thermal limit seconds after a cooler was replaced. Here the observed facts require cpu socket matching motherboard instead.
D:
Verify signed media boot and unsigned test boot is rejected by policy. That action is appropriate for uefi secure boot versus boot order, normally when a laptop can start a trusted OS but prompts when an unsigned bootloader is inserted. Here the observed facts require cpu socket matching motherboard instead.
Question 705
At Bluefin Logistics, a technician working in end-user troubleshooting identifies this issue: Multiple desktops get 169.254.x.x addresses after a new VLAN is added but its DHCP relay is missing. The desired outcome is to identify absent DHCP replies rather than blaming remote DNS first. The goal is to restore required function without creating a new security or safety problem. Which safe pilot action gives the most relevant evidence?
- Renew a test client's lease after repairing the permitted DHCP relay
- Use a certified spare patch cable and run a non-destructive cable wiremap test
- Resolve an approved internal hostname from a test client using the corrected DNS server
- Test a compatible known-good panel with safe power isolation
Explanation
Correct Answer
A:
Renew a test client's lease after repairing the permitted DHCP relay. It tests the proposed solution safely on an approved representative system. The relevant observation is that multiple desktops get 169.254.x.x addresses after a new VLAN is added but its DHCP relay is missing. The support goal is to identify absent DHCP replies rather than blaming remote DNS first; this pilot action specifically addresses dhcp failure and 169.254 apipa symptom without confusing a different subsystem.
Incorrect Answers
B:
Use a certified spare patch cable and run a non-destructive cable wiremap test. This action is appropriate for copper ethernet link flapping, normally when a workstation loses Ethernet connection whenever its patch lead is bent. Here the observed facts require dhcp failure and 169.254 apipa symptom instead.
C:
Resolve an approved internal hostname from a test client using the corrected DNS server. This action is appropriate for dns failure with working ip connectivity, normally when a workstation opens a service directly by numeric IP but says its hostname cannot be resolved. Here the observed facts require dhcp failure and 169.254 apipa symptom instead.
D:
Test a compatible known-good panel with safe power isolation. This action is appropriate for backlight failure on laptop lcd, normally when a laptop screen looks black but a flashlight reveals a faint intact desktop image. Here the observed facts require dhcp failure and 169.254 apipa symptom instead.
Question 706
At Pioneer Markets, a technician working in end-user troubleshooting identifies this issue: A new monitor's text appears soft because the operating system outputs 1366x768 to a 1920x1080 panel. The desired outcome is to correct resolution and scaling without treating blur as pixel hardware failure. The customer requires a verified fix rather than a guess based on one symptom. Which inspection most directly confirms the likely cause before changing components?
- Inspect port access and voice VLAN settings, LLDP, assigned IP subnets and switch change log
- Review native panel resolution, current OS scaling and cable mode limits
- Check cable damage, connector strain, monitor input selection and GPU outputs
- Inspect brightness controls, display cable, backlight power and serviceable panel components
Explanation
Correct Answer
B:
Review native panel resolution, current OS scaling and cable mode limits. It checks the likely failure boundary before altering working parts or settings. The relevant observation is that a new monitor's text appears soft because the operating system outputs 1366x768 to a 1920x1080 panel. The support goal is to correct resolution and scaling without treating blur as pixel hardware failure; this diagnose action specifically addresses wrong screen resolution and scaling without confusing a different subsystem.
Incorrect Answers
A:
Inspect port access and voice VLAN settings, LLDP, assigned IP subnets and switch change log. This action is appropriate for vlan mismatch causing one desk to lose access, normally when a desk phone and PC stop reaching their correct services after a switch port change. Here the observed facts require wrong screen resolution and scaling instead.
C:
Check cable damage, connector strain, monitor input selection and GPU outputs. This action is appropriate for intermittent monitor image due to video cable, normally when a monitor intermittently goes black when its display cable is moved. Here the observed facts require wrong screen resolution and scaling instead.
D:
Inspect brightness controls, display cable, backlight power and serviceable panel components. This action is appropriate for backlight failure on laptop lcd, normally when a laptop screen looks black but a flashlight reveals a faint intact desktop image. Here the observed facts require wrong screen resolution and scaling instead.
Question 707
During Seabright Supplies's computer equipment refresh, the technician encounters this condition: A design lab orders ECC RAM for a desktop that cannot activate memory error correction. The desired outcome is to select ECC hardware only where CPU and board support its error reporting. The goal is to restore required function without creating a new security or safety problem. Which acceptance result best demonstrates the issue is resolved?
- Verify secure latching, firmware recognition and memory diagnostics
- Verify memory training succeeds at an approved speed with no diagnostic errors
- Verify both resolution and refresh rate match the intended values in display settings
- Verify firmware exposes ECC mode and error reporting rather than merely booting
Explanation
Correct Answer
D:
Verify firmware exposes ECC mode and error reporting rather than merely booting. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that a design lab orders ECC RAM for a desktop that cannot activate memory error correction. The support goal is to select ECC hardware only where CPU and board support its error reporting; this validate action specifically addresses ecc memory error correction compatibility without confusing a different subsystem.
Incorrect Answers
A:
Verify secure latching, firmware recognition and memory diagnostics. That action is appropriate for sodimm versus dimm form factor, normally when a desktop repair requires replacement memory but the spare part comes from a notebook. Here the observed facts require ecc memory error correction compatibility instead.
B:
Verify memory training succeeds at an approved speed with no diagnostic errors. That action is appropriate for ddr generation electrical compatibility, normally when a replacement RAM order has the correct capacity but the wrong DDR generation. Here the observed facts require ecc memory error correction compatibility instead.
C:
Verify both resolution and refresh rate match the intended values in display settings. This action is appropriate for refresh rate versus screen resolution, normally when a support buyer mistakes 144 Hz for a count of display pixels when comparing two monitors. Here the observed facts require ecc memory error correction compatibility instead.
Question 708
On a service ticket for Clearwater Telecom, the team observes: A desktop color inkjet skips alternating bands after sitting unused for months. The desired outcome is to correct an ink delivery issue rather than changing duplex settings. The technician must document observations separately from assumptions. Which safe pilot action gives the most relevant evidence?
- Run one controlled cleaning cycle and print a nozzle verification pattern
- Print a known test pattern after substituting a known-good imaging unit
- Boot from a known-good test cable while leaving drive content unchanged
- Feed a short set of labeled test media in the proper orientation
Explanation
Correct Answer
A:
Run one controlled cleaning cycle and print a nozzle verification pattern. It tests the proposed solution safely on an approved representative system. The relevant observation is that a desktop color inkjet skips alternating bands after sitting unused for months. The support goal is to correct an ink delivery issue rather than changing duplex settings; this pilot action specifically addresses inkjet horizontal banding and nozzle obstruction without confusing a different subsystem.
Incorrect Answers
B:
Print a known test pattern after substituting a known-good imaging unit. That action is appropriate for laser repeated streaks from drum defect, normally when printed laser pages have a dark stripe repeated at the same distance down each sheet. Here the observed facts require inkjet horizontal banding and nozzle obstruction instead.
C:
Boot from a known-good test cable while leaving drive content unchanged. This action is appropriate for intermittent sata cable data fault, normally when a SATA HDD disappears occasionally despite healthy spin-up and no clear media errors. Here the observed facts require inkjet horizontal banding and nozzle obstruction instead.
D:
Feed a short set of labeled test media in the proper orientation. That action is appropriate for thermal printer paper orientation, normally when a shipping label printer feeds paper but produces completely blank labels. Here the observed facts require inkjet horizontal banding and nozzle obstruction instead.
Question 709
A support request at Keystone Health presents this problem: A technician orders an M.2 SSD for a motherboard slot that supports only SATA signaling. The supporting record states that the purchased M.2 drive uses NVMe over PCIe even though the cards look physically similar. The desired outcome is to match storage interface protocol to motherboard slot capabilities. The technician must document observations separately from assumptions. What observation would verify successful service restoration?
- Verify improved access latency and acceptable write endurance for the workload
- Verify drive detection and intended interface performance without forcing a mismatched module
- Confirm the optical receive power and link speed meet both transceiver specifications
- Verify all conductors and pairs map correctly end-to-end
Explanation
Correct Answer
B:
Verify drive detection and intended interface performance without forcing a mismatched module. It proves the required function with an observable result instead of assuming the change worked. The relevant observation is that the purchased M.2 drive uses NVMe over PCIe even though the cards look physically similar. The support goal is to match storage interface protocol to motherboard slot capabilities; this validate action specifically addresses nvme pcie versus sata storage interface without confusing a different subsystem.
Incorrect Answers
A:
Verify improved access latency and acceptable write endurance for the workload. This action is appropriate for ssd versus hdd latency and interface, normally when a mobile user needs low-latency storage and shock resistance but a procurement request specifies a 5400 RPM hard disk. Here the observed facts require nvme pcie versus sata storage interface instead.
C:
Confirm the optical receive power and link speed meet both transceiver specifications. That action is appropriate for single-mode versus multimode fiber, normally when a campus backbone spans several kilometers between buildings and requires high throughput. Here the observed facts require nvme pcie versus sata storage interface instead.
D:
Verify all conductors and pairs map correctly end-to-end. That action is appropriate for t568a versus t568b rj45 terminations, normally when a newly crimped eight-wire Ethernet cable fails a wiremap test because one end follows T568A and the other T568B. Here the observed facts require nvme pcie versus sata storage interface instead.
Question 710
On a service ticket for Granite Capital, the team observes: A two-drive NAS needs continued access after one drive fails rather than the combined capacity of RAID 0. The desired outcome is to choose RAID 1 when simple mirroring is the requirement. A safe non-destructive test must be used before replacing additional parts. What should the technician recommend as the corrective approach?
- Configure a supported two-disk RAID 1 mirror giving approximately one disk of usable capacity
- Set the intended paper tray, form size and two-sided mode in driver or print server
- Configure a four-disk RAID 10 set for balanced performance and redundancy
- Use RAID 6 when the stated requirement is two-drive fault tolerance
Explanation
Correct Answer
A:
Configure a supported two-disk RAID 1 mirror giving approximately one disk of usable capacity. It corrects the documented cause using the compatible technology and support constraints. The relevant observation is that a two-drive NAS needs continued access after one drive fails rather than the combined capacity of RAID 0. The support goal is to choose RAID 1 when simple mirroring is the requirement; this design action specifically addresses raid 1 mirror capacity and resilience without confusing a different subsystem.
Incorrect Answers
B:
Set the intended paper tray, form size and two-sided mode in driver or print server. This action is appropriate for printer duplex and tray settings, normally when a network printer puts letter-size forms on the wrong paper and uses one-sided output. Here the observed facts require raid 1 mirror capacity and resilience instead.
C:
Configure a four-disk RAID 10 set for balanced performance and redundancy. That action is appropriate for raid 10 mirrored striped array, normally when a database server needs fast disk I/O and redundancy with four equal drives. Here the observed facts require raid 1 mirror capacity and resilience instead.
D:
Use RAID 6 when the stated requirement is two-drive fault tolerance. That action is appropriate for raid 5 versus raid 6 dual parity, normally when a four-disk production array must remain available during any two simultaneous drive failures. Here the observed facts require raid 1 mirror capacity and resilience instead.