cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 83

Question 820

A Fibre Channel-connected server sees two target paths yet only one is in the host's multipath policy. The observed failure is: two physical connections without a working multipath stack do not guarantee storage continuity. What should the engineer do to recover and validate the service?

  1. The controlled remediation is to use a switch management VRF as the only host storage failover mechanism.
  2. The controlled remediation is to expose the same storage LUN as unrelated writable devices with no multipath correlation.
  3. The controlled remediation is to remove one path permanently and call it redundant.
  4. The controlled remediation is to correct path discovery and failover settings and test a controlled single-path outage.

Explanation

Correct Answer

D:

Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. Validate against host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.

Incorrect Answers

A:

Use a switch management VRF as the only host storage failover mechanism. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.

B:

Expose the same storage LUN as unrelated writable devices with no multipath correlation. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.

C:

Remove one path permanently and call it redundant. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.

Question 821

An MDS SAN upgrade is scheduled as nondisruptive without checking release and supervisor compatibility. Which operator action best meets this technical requirement?

  1. Review the supported MDS upgrade path, supervisor or module prerequisites, and disruption analysis before execution.
  2. Apply arbitrary firmware and rely on FC zoning to prevent reboots.
  3. Skip interoperability checks because FC link lights are stable.
  4. Delete all backup configuration before invoking the upgrade.

Explanation

Correct Answer

A:

This directly addresses mDS nondisruptive upgrade prerequisites because storage fabric upgrade service impact depends on platform capability, release path and redundant topology. Confirm the change against mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

Incorrect Answers

B:

An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. The relevant correction is to review the supported MDS upgrade path, supervisor or module prerequisites, and disruption analysis before execution.

C:

Skip interoperability checks because FC link lights are stable. The proposed change targets the wrong mechanism or lacks essential validation. Storage fabric upgrade service impact depends on platform capability, release path and redundant topology. Relevant evidence is mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

D:

An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. The appropriate action remains to review the supported MDS upgrade path, supervisor or module prerequisites, and disruption analysis before execution.

Question 822

An MDS SAN upgrade is scheduled as nondisruptive without checking release and supervisor compatibility. Which collection of observations most directly tests the suspected cause?

  1. A green physical FC link light without fabric login, zoning or I/O evidence.
  2. MDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.
  3. An Ethernet ping that does not test the required SAN session or VSAN.
  4. A storage vendor slogan without the relevant login and path counters.

Explanation

Correct Answer

B:

These observations test the actual mDS nondisruptive upgrade prerequisites mechanism rather than a superficial management status. Storage fabric upgrade service impact depends on platform capability, release path and redundant topology.

Incorrect Answers

A:

This information cannot independently verify mDS nondisruptive upgrade prerequisites. The decisive records instead include mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

C:

This information cannot independently verify mDS nondisruptive upgrade prerequisites. Storage fabric upgrade service impact depends on platform capability, release path and redundant topology.

D:

This information cannot independently verify mDS nondisruptive upgrade prerequisites. A storage vendor slogan without the relevant login and path counters.

Question 823

An MDS SAN upgrade is scheduled as nondisruptive without checking release and supervisor compatibility. Which statement most accurately explains this scenario?

  1. WWPN zoning and IP access lists are interchangeable security primitives.
  2. Every storage protocol provides the same file and block semantics.
  3. Storage fabric upgrade service impact depends on platform capability, release path and redundant topology.
  4. A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.

Explanation

Correct Answer

C:

Validation depends on mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact. This explains why the most appropriate response is to review the supported MDS upgrade path, supervisor or module prerequisites, and disruption analysis before execution.

Incorrect Answers

A:

WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for mDS nondisruptive upgrade prerequisites. The applicable technical behavior is that storage fabric upgrade service impact depends on platform capability, release path and redundant topology. The operator should verify mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

B:

Every storage protocol provides the same file and block semantics. This is an incorrect generalization for mDS nondisruptive upgrade prerequisites. The applicable technical behavior is that storage fabric upgrade service impact depends on platform capability, release path and redundant topology. The operator should verify mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

D:

A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for mDS nondisruptive upgrade prerequisites. The applicable technical behavior is that storage fabric upgrade service impact depends on platform capability, release path and redundant topology. The operator should verify mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

Question 824

An MDS SAN upgrade is scheduled as nondisruptive without checking release and supervisor compatibility. Assume an engineer instead chooses to apply arbitrary firmware and rely on FC zoning to prevent reboots. What is the principal technical consequence of the mistaken choice?

  1. A well-documented host multipath test is the source of the original fabric fault.
  2. Examining FCNS entries automatically removes the authorized zoning policy.
  3. The SAN failed because operators retained correct WWPN identity records.
  4. An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan.

Explanation

Correct Answer

D:

The proper corrective action is to review the supported MDS upgrade path, supervisor or module prerequisites, and disruption analysis before execution. Storage fabric upgrade service impact depends on platform capability, release path and redundant topology.

Incorrect Answers

A:

This does not explain the actual mDS nondisruptive upgrade prerequisites defect after the shortcut. The meaningful failure is that an unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan.

B:

This does not explain the actual mDS nondisruptive upgrade prerequisites defect after the shortcut. The relevant evidence is mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

C:

This does not explain the actual mDS nondisruptive upgrade prerequisites defect after the shortcut. The SAN failed because operators retained correct WWPN identity records.

Question 825

An MDS SAN upgrade is scheduled as nondisruptive without checking release and supervisor compatibility. The observed failure is: an unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. What should the engineer do to recover and validate the service?

  1. Select a supported path, schedule disruption if needed, and validate fabric and host multipath afterward.
  2. Skip interoperability checks because FC link lights are stable.
  3. Delete all backup configuration before invoking the upgrade.
  4. Apply arbitrary firmware and rely on FC zoning to prevent reboots.

Explanation

Correct Answer

A:

This addresses the observable fault while preserving a check of the expected result. Storage fabric upgrade service impact depends on platform capability, release path and redundant topology.

Incorrect Answers

B:

Skip interoperability checks because FC link lights are stable. This would not reliably restore service after the stated fault. An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. The controlled recovery is to select a supported path, schedule disruption if needed, and validate fabric and host multipath afterward.

C:

Delete all backup configuration before invoking the upgrade. This would not reliably restore service after the stated fault. An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. The controlled recovery is to select a supported path, schedule disruption if needed, and validate fabric and host multipath afterward.

D:

Apply arbitrary firmware and rely on FC zoning to prevent reboots. This would not reliably restore service after the stated fault. An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. The controlled recovery is to select a supported path, schedule disruption if needed, and validate fabric and host multipath afterward.

Question 826

A Fibre Channel switch has an incompatible feature set for the chosen firmware path and the maintenance team assumes zero impact. Which next step should the data center engineer select?

  1. On this affected device, the engineer should skip interoperability checks because FC link lights are stable.
  2. On this affected device, the engineer should review the supported MDS upgrade path, supervisor or module prerequisites, and disruption analysis before execution.
  3. On this affected device, the engineer should delete all backup configuration before invoking the upgrade.
  4. On this affected device, the engineer should apply arbitrary firmware and rely on FC zoning to prevent reboots.

Explanation

Correct Answer

B:

This directly addresses mDS nondisruptive upgrade prerequisites because storage fabric upgrade service impact depends on platform capability, release path and redundant topology.

Incorrect Answers

A:

Skip interoperability checks because FC link lights are stable. The proposed change targets the wrong mechanism or lacks essential validation. Storage fabric upgrade service impact depends on platform capability, release path and redundant topology. Relevant evidence is mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

C:

An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan.

D:

An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. Apply arbitrary firmware and rely on FC zoning to prevent reboots.

Question 827

A Fibre Channel switch has an incompatible feature set for the chosen firmware path and the maintenance team assumes zero impact. Which diagnostic record would most strongly confirm the result?

  1. For this deployment, examine a copied zoneset name without its active effective members.
  2. For this deployment, examine a green physical FC link light without fabric login, zoning or I/O evidence.
  3. For this deployment, examine mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.
  4. For this deployment, examine an Ethernet ping that does not test the required SAN session or VSAN.

Explanation

Correct Answer

C:

These observations test the actual mDS nondisruptive upgrade prerequisites mechanism rather than a superficial management status. They should be checked after review the supported MDS upgrade path, supervisor or module prerequisites, and disruption analysis before execution.

Incorrect Answers

A:

This information cannot independently verify mDS nondisruptive upgrade prerequisites. A copied zoneset name without its active effective members.

B:

This information cannot independently verify mDS nondisruptive upgrade prerequisites. A green physical FC link light without fabric login, zoning or I/O evidence.

D:

This information cannot independently verify mDS nondisruptive upgrade prerequisites. An Ethernet ping that does not test the required SAN session or VSAN.

Question 828

A Fibre Channel switch has an incompatible feature set for the chosen firmware path and the maintenance team assumes zero impact. Which platform concept should guide the engineer’s assessment?

  1. For this condition, the applicable principle is that a lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
  2. For this condition, the applicable principle is that wWPN zoning and IP access lists are interchangeable security primitives.
  3. For this condition, the applicable principle is that Fibre Channel name service entries are identical to host multipath device state.
  4. For this condition, the applicable principle is that storage fabric upgrade service impact depends on platform capability, release path and redundant topology.

Explanation

Correct Answer

D:

Validation depends on mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact. Storage fabric upgrade service impact depends on platform capability, release path and redundant topology.

Incorrect Answers

A:

A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for mDS nondisruptive upgrade prerequisites. The applicable technical behavior is that storage fabric upgrade service impact depends on platform capability, release path and redundant topology. The operator should verify mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

B:

WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for mDS nondisruptive upgrade prerequisites. The applicable technical behavior is that storage fabric upgrade service impact depends on platform capability, release path and redundant topology. The operator should verify mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

C:

Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for mDS nondisruptive upgrade prerequisites. The applicable technical behavior is that storage fabric upgrade service impact depends on platform capability, release path and redundant topology. The operator should verify mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

Question 829

A Fibre Channel switch has an incompatible feature set for the chosen firmware path and the maintenance team assumes zero impact. Assume an engineer instead chooses to apply arbitrary firmware and rely on FC zoning to prevent reboots. Which root-cause observation follows from that incorrect change?

  1. The resulting defect is that an unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan.
  2. The resulting defect is that the SAN failed because operators retained correct WWPN identity records.
  3. The resulting defect is that the sole error was using a verified SAN maintenance window for a risky operation.
  4. The resulting defect is that examining FCNS entries automatically removes the authorized zoning policy.

Explanation

Correct Answer

A:

The proper corrective action is to review the supported MDS upgrade path, supervisor or module prerequisites, and disruption analysis before execution. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

B:

This does not explain the actual mDS nondisruptive upgrade prerequisites defect after the shortcut. In the given case, a Fibre Channel switch has an incompatible feature set for the chosen firmware path and the maintenance team assumes zero impact.

C:

This does not explain the actual mDS nondisruptive upgrade prerequisites defect after the shortcut. The sole error was using a verified SAN maintenance window for a risky operation.

D:

This does not explain the actual mDS nondisruptive upgrade prerequisites defect after the shortcut. Examining FCNS entries automatically removes the authorized zoning policy.

Question 830

A Fibre Channel switch has an incompatible feature set for the chosen firmware path and the maintenance team assumes zero impact. The observed failure is: an unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. Which recovery action addresses the underlying technical fault?

  1. The controlled remediation is to delete all backup configuration before invoking the upgrade.
  2. The controlled remediation is to select a supported path, schedule disruption if needed, and validate fabric and host multipath afterward.
  3. The controlled remediation is to apply arbitrary firmware and rely on FC zoning to prevent reboots.
  4. The controlled remediation is to skip interoperability checks because FC link lights are stable.

Explanation

Correct Answer

B:

Validate against mDS release upgrade matrix, module versions, supported ISSU path and expected SAN path impact.

Incorrect Answers

A:

Delete all backup configuration before invoking the upgrade. This would not reliably restore service after the stated fault. An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. The controlled recovery is to select a supported path, schedule disruption if needed, and validate fabric and host multipath afterward.

C:

Apply arbitrary firmware and rely on FC zoning to prevent reboots. This would not reliably restore service after the stated fault. An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. The controlled recovery is to select a supported path, schedule disruption if needed, and validate fabric and host multipath afterward.

D:

Skip interoperability checks because FC link lights are stable. This would not reliably restore service after the stated fault. An unsupported upgrade path may reset SAN control or data connectivity despite a nondisruptive plan. The controlled recovery is to select a supported path, schedule disruption if needed, and validate fabric and host multipath afterward.

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests