Cisco 350-601 Practice Test 82
Question 810
A storage array reports repeated failed iSCSI authentication even though initiator and target communicate over TCP. The observed failure is: discovery and IP reachability are insufficient to establish an authenticated iSCSI session. Which remediation most directly restores the intended behavior?
- The controlled remediation is to use a Fibre Channel zoning alias as the CHAP user password.
- The controlled remediation is to correct secret and authentication mode, then verify session establishment without exposing credentials.
- The controlled remediation is to disable every target access restriction rather than fixing CHAP.
- The controlled remediation is to set an unrelated Ethernet MTU to be the CHAP shared secret.
Explanation
Correct Answer
B:Validate against iSCSI login status, CHAP failure log, initiator IQN, target authentication policy and secret configuration. CHAP authentication protects iSCSI login by requiring matching configured credentials.
Incorrect Answers
A:Use a Fibre Channel zoning alias as the CHAP user password. This would not reliably restore service after the stated fault. Discovery and IP reachability are insufficient to establish an authenticated iSCSI session. The controlled recovery is to correct secret and authentication mode, then verify session establishment without exposing credentials.
C:Disable every target access restriction rather than fixing CHAP. This would not reliably restore service after the stated fault. Discovery and IP reachability are insufficient to establish an authenticated iSCSI session. The controlled recovery is to correct secret and authentication mode, then verify session establishment without exposing credentials.
D:Set an unrelated Ethernet MTU to be the CHAP shared secret. This would not reliably restore service after the stated fault. Discovery and IP reachability are insufficient to establish an authenticated iSCSI session. The controlled recovery is to correct secret and authentication mode, then verify session establishment without exposing credentials.
Question 811
A hypervisor has two iSCSI network paths but still loses access when its active uplink fails because multipathing is not configured. Which configuration decision MOST directly resolves the issue?
- Expose the same storage LUN as unrelated writable devices with no multipath correlation.
- Remove one path permanently and call it redundant.
- Configure and test supported host multipath policy with independent storage fabric or network paths.
- Use a switch management VRF as the only host storage failover mechanism.
Explanation
Correct Answer
C:This directly addresses multipath storage failover because multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. Confirm the change against host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
Incorrect Answers
A:Two physical connections without a working multipath stack do not guarantee storage continuity. The relevant correction is to configure and test supported host multipath policy with independent storage fabric or network paths.
B:That option would remove one path permanently and call it redundant, but it addresses a different concern. This directly addresses multipath storage failover because multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
D:Two physical connections without a working multipath stack do not guarantee storage continuity. The appropriate action remains to configure and test supported host multipath policy with independent storage fabric or network paths.
Question 812
A hypervisor has two iSCSI network paths but still loses access when its active uplink fails because multipathing is not configured. What should the engineer inspect to confirm the actual state?
- A historical FC topology drawing with no current WWPN or port state.
- A storage vendor slogan without the relevant login and path counters.
- A copied zoneset name without its active effective members.
- Host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
Explanation
Correct Answer
D:These observations test the actual multipath storage failover mechanism rather than a superficial management status. Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
Incorrect Answers
A:A historical FC topology drawing with no current WWPN or port state. This information cannot independently verify multipath storage failover. The decisive records instead include host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results. Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
B:A storage vendor slogan without the relevant login and path counters. This information cannot independently verify multipath storage failover. The decisive records instead include host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results. Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
C:A copied zoneset name without its active effective members. This information cannot independently verify multipath storage failover. The decisive records instead include host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results. Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
Question 813
A hypervisor has two iSCSI network paths but still loses access when its active uplink fails because multipathing is not configured. What technical behavior underlies the correct decision?
- Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
- Every storage protocol provides the same file and block semantics.
- Fibre Channel name service entries are identical to host multipath device state.
- An unused VSAN number can replace an active zoning or port security rule.
Explanation
Correct Answer
A:Validation depends on host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results. This explains why the most appropriate response is to configure and test supported host multipath policy with independent storage fabric or network paths.
Incorrect Answers
B:Every storage protocol provides the same file and block semantics. This is an incorrect generalization for multipath storage failover. The applicable technical behavior is that multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. The operator should verify host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
C:Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for multipath storage failover. The applicable technical behavior is that multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. The operator should verify host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
D:An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for multipath storage failover. The applicable technical behavior is that multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. The operator should verify host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
Question 814
A hypervisor has two iSCSI network paths but still loses access when its active uplink fails because multipathing is not configured. Assume an engineer instead chooses to expose the same storage LUN as unrelated writable devices with no multipath correlation. Which resulting risk or fault should the reviewer identify?
- The sole error was using a verified SAN maintenance window for a risky operation.
- Two physical connections without a working multipath stack do not guarantee storage continuity.
- Inspecting credit counters prevents FC frames from forwarding.
- A well-documented host multipath test is the source of the original fabric fault.
Explanation
Correct Answer
B:Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual multipath storage failover defect after the shortcut. The meaningful failure is that two physical connections without a working multipath stack do not guarantee storage continuity.
C:This does not explain the actual multipath storage failover defect after the shortcut. The relevant evidence is host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
D:This does not explain the actual multipath storage failover defect after the shortcut. In the given case, a hypervisor has two iSCSI network paths but still loses access when its active uplink fails because multipathing is not configured.
Question 815
A hypervisor has two iSCSI network paths but still loses access when its active uplink fails because multipathing is not configured. The observed failure is: two physical connections without a working multipath stack do not guarantee storage continuity. Which remediation most directly restores the intended behavior?
- Remove one path permanently and call it redundant.
- Use a switch management VRF as the only host storage failover mechanism.
- Correct path discovery and failover settings and test a controlled single-path outage.
- Expose the same storage LUN as unrelated writable devices with no multipath correlation.
Explanation
Correct Answer
C:Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
A:Remove one path permanently and call it redundant. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.
B:Use a switch management VRF as the only host storage failover mechanism. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.
D:Expose the same storage LUN as unrelated writable devices with no multipath correlation. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.
Question 816
A Fibre Channel-connected server sees two target paths yet only one is in the host's multipath policy. Which operator action best meets this technical requirement?
- On this affected device, the engineer should remove one path permanently and call it redundant.
- On this affected device, the engineer should use a switch management VRF as the only host storage failover mechanism.
- On this affected device, the engineer should expose the same storage LUN as unrelated writable devices with no multipath correlation.
- On this affected device, the engineer should configure and test supported host multipath policy with independent storage fabric or network paths.
Explanation
Correct Answer
D:This directly addresses multipath storage failover because multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
Incorrect Answers
A:Remove one path permanently and call it redundant. The proposed change targets the wrong mechanism or lacks essential validation. Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. Relevant evidence is host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
B:Two physical connections without a working multipath stack do not guarantee storage continuity. Use a switch management VRF as the only host storage failover mechanism.
C:Two physical connections without a working multipath stack do not guarantee storage continuity. In the given case, a Fibre Channel-connected server sees two target paths yet only one is in the host's multipath policy.
Question 817
A Fibre Channel-connected server sees two target paths yet only one is in the host's multipath policy. Which collection of observations most directly tests the suspected cause?
- For this deployment, examine host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
- For this deployment, examine a green physical FC link light without fabric login, zoning or I/O evidence.
- For this deployment, examine a historical FC topology drawing with no current WWPN or port state.
- For this deployment, examine a storage vendor slogan without the relevant login and path counters.
Explanation
Correct Answer
A:These observations test the actual multipath storage failover mechanism rather than a superficial management status. They should be checked after configure and test supported host multipath policy with independent storage fabric or network paths.
Incorrect Answers
B:A green physical FC link light without fabric login, zoning or I/O evidence. This information cannot independently verify multipath storage failover. The decisive records instead include host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results. Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
C:A historical FC topology drawing with no current WWPN or port state. This information cannot independently verify multipath storage failover. The decisive records instead include host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results. Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
D:A storage vendor slogan without the relevant login and path counters. This information cannot independently verify multipath storage failover. The decisive records instead include host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results. Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
Question 818
A Fibre Channel-connected server sees two target paths yet only one is in the host's multipath policy. Which statement most accurately explains this scenario?
- For this condition, the applicable principle is that an unused VSAN number can replace an active zoning or port security rule.
- For this condition, the applicable principle is that multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails.
- For this condition, the applicable principle is that every storage protocol provides the same file and block semantics.
- For this condition, the applicable principle is that a lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
Explanation
Correct Answer
B:Validation depends on host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
Incorrect Answers
A:An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for multipath storage failover. The applicable technical behavior is that multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. The operator should verify host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
C:Every storage protocol provides the same file and block semantics. This is an incorrect generalization for multipath storage failover. The applicable technical behavior is that multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. The operator should verify host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
D:A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for multipath storage failover. The applicable technical behavior is that multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. The operator should verify host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
Question 819
A Fibre Channel-connected server sees two target paths yet only one is in the host's multipath policy. Assume an engineer instead chooses to expose the same storage LUN as unrelated writable devices with no multipath correlation. What is the principal technical consequence of the mistaken choice?
- The resulting defect is that a well-documented host multipath test is the source of the original fabric fault.
- The resulting defect is that examining FCNS entries automatically removes the authorized zoning policy.
- The resulting defect is that two physical connections without a working multipath stack do not guarantee storage continuity.
- The resulting defect is that inspecting credit counters prevents FC frames from forwarding.
Explanation
Correct Answer
C:Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. The proper corrective action is to configure and test supported host multipath policy with independent storage fabric or network paths.
Incorrect Answers
A:This does not explain the actual multipath storage failover defect after the shortcut. In the given case, a Fibre Channel-connected server sees two target paths yet only one is in the host's multipath policy.
B:This does not explain the actual multipath storage failover defect after the shortcut. Examining FCNS entries automatically removes the authorized zoning policy.
D:The meaningful failure is that two physical connections without a working multipath stack do not guarantee storage continuity.
Question 820
A Fibre Channel-connected server sees two target paths yet only one is in the host's multipath policy. The observed failure is: two physical connections without a working multipath stack do not guarantee storage continuity. What should the engineer do to recover and validate the service?
- The controlled remediation is to use a switch management VRF as the only host storage failover mechanism.
- The controlled remediation is to expose the same storage LUN as unrelated writable devices with no multipath correlation.
- The controlled remediation is to remove one path permanently and call it redundant.
- The controlled remediation is to correct path discovery and failover settings and test a controlled single-path outage.
Explanation
Correct Answer
D:Multipathing coordinates redundant logical routes to the same storage device and preserves I/O when a path fails. Validate against host multipath devices, path health, storage target presentation, path-selection policy and failover I/O results.
Incorrect Answers
A:Use a switch management VRF as the only host storage failover mechanism. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.
B:Expose the same storage LUN as unrelated writable devices with no multipath correlation. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.
C:Remove one path permanently and call it redundant. This would not reliably restore service after the stated fault. Two physical connections without a working multipath stack do not guarantee storage continuity. The controlled recovery is to correct path discovery and failover settings and test a controlled single-path outage.