cert
cert-1
cert-2

Pass Cisco 350-601 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
350-601 Exam - Verified By Experts
350-601 Premium Bundle
$29.98

350-601 Premium Bundle

$79.99
$109.97
  • Premium File 613 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 143 Video Lectures
  • Study Guide 1923 Pages
 
$109.97
$79.99
accept 46 downloads in last 7 days
block-screenshots
Purchase Cisco 350-601 Exam Training Products Individually
Cisco 350-601 Premium File
Premium File 613 Q&A
$76.99$69.99
Cisco 350-601 Video Training Course
Training Course 143 Lectures
$21.99 $19.99
Cisco 350-601 PDF Study Guide
Study Guide 1923 Pages
$21.99 $19.99
Cisco 350-601 Practice Test 66

Question 650

Storage engineers want to allow a new host to reach a target without exposing every initiator to each other's fabric endpoints. The observed failure is: broad zones increase unwanted initiator visibility and make change impact harder to isolate. Which remediation most directly restores the intended behavior?

  1. The controlled remediation is to remove all zoning while assuming storage array masking alone meets every fabric policy.
  2. The controlled remediation is to create specific zones, activate the approved zoneset and validate host-to-target access.
  3. The controlled remediation is to put every WWPN in one giant zone for all fabrics.
  4. The controlled remediation is to rely on IP subnets to enforce Fibre Channel WWPN isolation.

Explanation

Correct Answer

B:

Validate against zone and zoneset contents, active activation status, initiator and target WWPNs, and LUN presentation. Fibre Channel zoning limits which devices can discover and communicate across a fabric.

Incorrect Answers

A:

Remove all zoning while assuming storage array masking alone meets every fabric policy. This would not reliably restore service after the stated fault. Broad zones increase unwanted initiator visibility and make change impact harder to isolate. The controlled recovery is to create specific zones, activate the approved zoneset and validate host-to-target access.

C:

Put every WWPN in one giant zone for all fabrics. This would not reliably restore service after the stated fault. Broad zones increase unwanted initiator visibility and make change impact harder to isolate. The controlled recovery is to create specific zones, activate the approved zoneset and validate host-to-target access.

D:

Rely on IP subnets to enforce Fibre Channel WWPN isolation. This would not reliably restore service after the stated fault. Broad zones increase unwanted initiator visibility and make change impact harder to isolate. The controlled recovery is to create specific zones, activate the approved zoneset and validate host-to-target access.

Question 651

An administrator adds a new FC zone to a configuration but hosts still cannot reach the added target because the zoneset was not activated. Which configuration decision MOST directly resolves the issue?

  1. Edit interface descriptions and assume they activate zoning automatically.
  2. Delete all existing zones before enabling one new target.
  3. Activate the intended zoneset in the correct VSAN after validating the zone changes.
  4. Move the target to an arbitrary unrelated VSAN to avoid activation.

Explanation

Correct Answer

C:

This directly addresses zoneset activation scope because defining a zone is not the same as activating a zoneset that enforces the connectivity policy. Confirm the change against full zoning database, currently active zoneset, VSAN ID and host login visibility.

Incorrect Answers

A:

Inactive zone edits cannot authorize new host-target communication in the running fabric. The relevant correction is to activate the intended zoneset in the correct VSAN after validating the zone changes.

B:

Delete all existing zones before enabling one new target. The proposed change targets the wrong mechanism or lacks essential validation. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy. Relevant evidence is full zoning database, currently active zoneset, VSAN ID and host login visibility.

D:

Inactive zone edits cannot authorize new host-target communication in the running fabric. The appropriate action remains to activate the intended zoneset in the correct VSAN after validating the zone changes.

Question 652

An administrator adds a new FC zone to a configuration but hosts still cannot reach the added target because the zoneset was not activated. What should the engineer inspect to confirm the actual state?

  1. An Ethernet ping that does not test the required SAN session or VSAN.
  2. A copied zoneset name without its active effective members.
  3. A green physical FC link light without fabric login, zoning or I/O evidence.
  4. Full zoning database, currently active zoneset, VSAN ID and host login visibility.

Explanation

Correct Answer

D:

These observations test the actual zoneset activation scope mechanism rather than a superficial management status. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy.

Incorrect Answers

A:

An Ethernet ping that does not test the required SAN session or VSAN. This information cannot independently verify zoneset activation scope. The decisive records instead include full zoning database, currently active zoneset, VSAN ID and host login visibility. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy.

B:

A copied zoneset name without its active effective members. This information cannot independently verify zoneset activation scope. The decisive records instead include full zoning database, currently active zoneset, VSAN ID and host login visibility. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy.

C:

A green physical FC link light without fabric login, zoning or I/O evidence. This information cannot independently verify zoneset activation scope. The decisive records instead include full zoning database, currently active zoneset, VSAN ID and host login visibility. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy.

Question 653

An administrator adds a new FC zone to a configuration but hosts still cannot reach the added target because the zoneset was not activated. What technical behavior underlies the correct decision?

  1. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy.
  2. Fibre Channel name service entries are identical to host multipath device state.
  3. A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
  4. WWPN zoning and IP access lists are interchangeable security primitives.

Explanation

Correct Answer

A:

This explains why the most appropriate response is to activate the intended zoneset in the correct VSAN after validating the zone changes. Validation depends on full zoning database, currently active zoneset, VSAN ID and host login visibility.

Incorrect Answers

B:

Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for zoneset activation scope. The applicable technical behavior is that defining a zone is not the same as activating a zoneset that enforces the connectivity policy. The operator should verify full zoning database, currently active zoneset, VSAN ID and host login visibility.

C:

A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for zoneset activation scope. The applicable technical behavior is that defining a zone is not the same as activating a zoneset that enforces the connectivity policy. The operator should verify full zoning database, currently active zoneset, VSAN ID and host login visibility.

D:

WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for zoneset activation scope. The applicable technical behavior is that defining a zone is not the same as activating a zoneset that enforces the connectivity policy. The operator should verify full zoning database, currently active zoneset, VSAN ID and host login visibility.

Question 654

An administrator adds a new FC zone to a configuration but hosts still cannot reach the added target because the zoneset was not activated. Assume an engineer instead chooses to edit interface descriptions and assume they activate zoning automatically. Which resulting risk or fault should the reviewer identify?

  1. Examining FCNS entries automatically removes the authorized zoning policy.
  2. Inactive zone edits cannot authorize new host-target communication in the running fabric.
  3. The SAN failed because operators retained correct WWPN identity records.
  4. The sole error was using a verified SAN maintenance window for a risky operation.

Explanation

Correct Answer

B:

Defining a zone is not the same as activating a zoneset that enforces the connectivity policy. The proper corrective action is to activate the intended zoneset in the correct VSAN after validating the zone changes.

Incorrect Answers

A:

This does not explain the actual zoneset activation scope defect after the shortcut. The meaningful failure is that inactive zone edits cannot authorize new host-target communication in the running fabric.

C:

This does not explain the actual zoneset activation scope defect after the shortcut. The relevant evidence is full zoning database, currently active zoneset, VSAN ID and host login visibility.

D:

This does not explain the actual zoneset activation scope defect after the shortcut. In the given case, an administrator adds a new FC zone to a configuration but hosts still cannot reach the added target because the zoneset was not activated.

Question 655

An administrator adds a new FC zone to a configuration but hosts still cannot reach the added target because the zoneset was not activated. The observed failure is: inactive zone edits cannot authorize new host-target communication in the running fabric. Which remediation most directly restores the intended behavior?

  1. Delete all existing zones before enabling one new target.
  2. Move the target to an arbitrary unrelated VSAN to avoid activation.
  3. Commit and activate the approved zoneset and verify FCNS discovery and initiator access.
  4. Edit interface descriptions and assume they activate zoning automatically.

Explanation

Correct Answer

C:

Defining a zone is not the same as activating a zoneset that enforces the connectivity policy. This addresses the observable fault while preserving a check of the expected result.

Incorrect Answers

A:

Delete all existing zones before enabling one new target. This would not reliably restore service after the stated fault. Inactive zone edits cannot authorize new host-target communication in the running fabric. The controlled recovery is to commit and activate the approved zoneset and verify FCNS discovery and initiator access.

B:

Move the target to an arbitrary unrelated VSAN to avoid activation. This would not reliably restore service after the stated fault. Inactive zone edits cannot authorize new host-target communication in the running fabric. The controlled recovery is to commit and activate the approved zoneset and verify FCNS discovery and initiator access.

D:

Edit interface descriptions and assume they activate zoning automatically. This would not reliably restore service after the stated fault. Inactive zone edits cannot authorize new host-target communication in the running fabric. The controlled recovery is to commit and activate the approved zoneset and verify FCNS discovery and initiator access.

Question 656

An MDS SAN has the expected zone database edits but the active zone set remains the old version in the target VSAN. Which operator action best meets this technical requirement?

  1. On this affected device, the engineer should delete all existing zones before enabling one new target.
  2. On this affected device, the engineer should move the target to an arbitrary unrelated VSAN to avoid activation.
  3. On this affected device, the engineer should edit interface descriptions and assume they activate zoning automatically.
  4. On this affected device, the engineer should activate the intended zoneset in the correct VSAN after validating the zone changes.

Explanation

Correct Answer

D:

This directly addresses zoneset activation scope because defining a zone is not the same as activating a zoneset that enforces the connectivity policy.

Incorrect Answers

A:

Delete all existing zones before enabling one new target. The proposed change targets the wrong mechanism or lacks essential validation. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy. Relevant evidence is full zoning database, currently active zoneset, VSAN ID and host login visibility.

B:

Inactive zone edits cannot authorize new host-target communication in the running fabric. In the given case, an MDS SAN has the expected zone database edits but the active zone set remains the old version in the target VSAN.

C:

Inactive zone edits cannot authorize new host-target communication in the running fabric. Edit interface descriptions and assume they activate zoning automatically.

Question 657

An MDS SAN has the expected zone database edits but the active zone set remains the old version in the target VSAN. Which collection of observations most directly tests the suspected cause?

  1. For this deployment, examine full zoning database, currently active zoneset, VSAN ID and host login visibility.
  2. For this deployment, examine a historical FC topology drawing with no current WWPN or port state.
  3. For this deployment, examine an Ethernet ping that does not test the required SAN session or VSAN.
  4. For this deployment, examine a copied zoneset name without its active effective members.

Explanation

Correct Answer

A:

These observations test the actual zoneset activation scope mechanism rather than a superficial management status. They should be checked after activate the intended zoneset in the correct VSAN after validating the zone changes.

Incorrect Answers

B:

A historical FC topology drawing with no current WWPN or port state. This information cannot independently verify zoneset activation scope. The decisive records instead include full zoning database, currently active zoneset, VSAN ID and host login visibility. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy.

C:

An Ethernet ping that does not test the required SAN session or VSAN. This information cannot independently verify zoneset activation scope. The decisive records instead include full zoning database, currently active zoneset, VSAN ID and host login visibility. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy.

D:

A copied zoneset name without its active effective members. This information cannot independently verify zoneset activation scope. The decisive records instead include full zoning database, currently active zoneset, VSAN ID and host login visibility. Defining a zone is not the same as activating a zoneset that enforces the connectivity policy.

Question 658

An MDS SAN has the expected zone database edits but the active zone set remains the old version in the target VSAN. Which statement most accurately explains this scenario?

  1. For this condition, the applicable principle is that wWPN zoning and IP access lists are interchangeable security primitives.
  2. For this condition, the applicable principle is that defining a zone is not the same as activating a zoneset that enforces the connectivity policy.
  3. For this condition, the applicable principle is that Fibre Channel name service entries are identical to host multipath device state.
  4. For this condition, the applicable principle is that an unused VSAN number can replace an active zoning or port security rule.

Explanation

Correct Answer

B:

This explains why the most appropriate response is to activate the intended zoneset in the correct VSAN after validating the zone changes. In the given case, an MDS SAN has the expected zone database edits but the active zone set remains the old version in the target VSAN.

Incorrect Answers

A:

WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for zoneset activation scope. The applicable technical behavior is that defining a zone is not the same as activating a zoneset that enforces the connectivity policy. The operator should verify full zoning database, currently active zoneset, VSAN ID and host login visibility.

C:

Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for zoneset activation scope. The applicable technical behavior is that defining a zone is not the same as activating a zoneset that enforces the connectivity policy. The operator should verify full zoning database, currently active zoneset, VSAN ID and host login visibility.

D:

An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for zoneset activation scope. The applicable technical behavior is that defining a zone is not the same as activating a zoneset that enforces the connectivity policy. The operator should verify full zoning database, currently active zoneset, VSAN ID and host login visibility.

Question 659

An MDS SAN has the expected zone database edits but the active zone set remains the old version in the target VSAN. Assume an engineer instead chooses to edit interface descriptions and assume they activate zoning automatically. What is the principal technical consequence of the mistaken choice?

  1. The resulting defect is that the sole error was using a verified SAN maintenance window for a risky operation.
  2. The resulting defect is that inspecting credit counters prevents FC frames from forwarding.
  3. The resulting defect is that inactive zone edits cannot authorize new host-target communication in the running fabric.
  4. The resulting defect is that the SAN failed because operators retained correct WWPN identity records.

Explanation

Correct Answer

C:

Defining a zone is not the same as activating a zoneset that enforces the connectivity policy. That is the direct consequence of choosing the misleading shortcut.

Incorrect Answers

A:

This does not explain the actual zoneset activation scope defect after the shortcut. In the given case, an MDS SAN has the expected zone database edits but the active zone set remains the old version in the target VSAN.

B:

The meaningful failure is that inactive zone edits cannot authorize new host-target communication in the running fabric.

D:

This does not explain the actual zoneset activation scope defect after the shortcut. The SAN failed because operators retained correct WWPN identity records.

Question 660

An MDS SAN has the expected zone database edits but the active zone set remains the old version in the target VSAN. The observed failure is: inactive zone edits cannot authorize new host-target communication in the running fabric. What should the engineer do to recover and validate the service?

  1. The controlled remediation is to move the target to an arbitrary unrelated VSAN to avoid activation.
  2. The controlled remediation is to edit interface descriptions and assume they activate zoning automatically.
  3. The controlled remediation is to delete all existing zones before enabling one new target.
  4. The controlled remediation is to commit and activate the approved zoneset and verify FCNS discovery and initiator access.

Explanation

Correct Answer

D:

Defining a zone is not the same as activating a zoneset that enforces the connectivity policy. Validate against full zoning database, currently active zoneset, VSAN ID and host login visibility.

Incorrect Answers

A:

Move the target to an arbitrary unrelated VSAN to avoid activation. This would not reliably restore service after the stated fault. Inactive zone edits cannot authorize new host-target communication in the running fabric. The controlled recovery is to commit and activate the approved zoneset and verify FCNS discovery and initiator access.

B:

Edit interface descriptions and assume they activate zoning automatically. This would not reliably restore service after the stated fault. Inactive zone edits cannot authorize new host-target communication in the running fabric. The controlled recovery is to commit and activate the approved zoneset and verify FCNS discovery and initiator access.

C:

Delete all existing zones before enabling one new target. This would not reliably restore service after the stated fault. Inactive zone edits cannot authorize new host-target communication in the running fabric. The controlled recovery is to commit and activate the approved zoneset and verify FCNS discovery and initiator access.

Implementing and Operating Cisco Data Center Core Technologies (DCCOR) (350-601) Practice Tests