Cisco 350-601 Practice Test 63
Question 620
An MDS switch port is up but the connected initiator never receives the expected FCID through fabric login. The observed failure is: a device without successful fabric login cannot reliably participate in normal FC name service or target discovery. What should the engineer do to recover and validate the service?
- The controlled remediation is to ignore FLOGI errors because the optical link LED is lit.
- The controlled remediation is to create an NFS export to assign an FCID to a Fibre Channel HBA.
- The controlled remediation is to use a host's IPv4 DHCP lease as the FCID.
- The controlled remediation is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
Explanation
Correct Answer
D:FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. Validate against fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
Incorrect Answers
A:Ignore FLOGI errors because the optical link LED is lit. This would not reliably restore service after the stated fault. A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The controlled recovery is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
B:Create an NFS export to assign an FCID to a Fibre Channel HBA. This would not reliably restore service after the stated fault. A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The controlled recovery is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
C:Use a host's IPv4 DHCP lease as the FCID. This would not reliably restore service after the stated fault. A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The controlled recovery is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
Question 621
An initiator completes FLOGI and appears in the FC name server but cannot establish a usable session with the storage target. Which operator action best meets this technical requirement?
- Trace PLOGI and PRLI exchange, zoning and target access to isolate the missing FC session phase.
- Change only the local interface description to establish PRLI.
- Assume a successful ARP reply proves Fibre Channel SCSI login.
- Disable every target ACL before identifying whether the login itself failed.
Explanation
Correct Answer
A:This directly addresses pLOGI and PRLI storage session because fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. Confirm the change against fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
Incorrect Answers
B:Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. The relevant correction is to trace PLOGI and PRLI exchange, zoning and target access to isolate the missing FC session phase.
C:That option would assume a successful ARP reply proves Fibre Channel SCSI login, but it addresses a different concern. This directly addresses pLOGI and PRLI storage session because fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets.
D:Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. The appropriate action remains to trace PLOGI and PRLI exchange, zoning and target access to isolate the missing FC session phase.
Question 622
An initiator completes FLOGI and appears in the FC name server but cannot establish a usable session with the storage target. Which collection of observations most directly tests the suspected cause?
- A green physical FC link light without fabric login, zoning or I/O evidence.
- FLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
- An Ethernet ping that does not test the required SAN session or VSAN.
- A storage vendor slogan without the relevant login and path counters.
Explanation
Correct Answer
B:These observations test the actual pLOGI and PRLI storage session mechanism rather than a superficial management status. Fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets.
Incorrect Answers
A:This information cannot independently verify pLOGI and PRLI storage session. The decisive records instead include fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
C:This information cannot independently verify pLOGI and PRLI storage session. Fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets.
D:This information cannot independently verify pLOGI and PRLI storage session. A storage vendor slogan without the relevant login and path counters.
Question 623
An initiator completes FLOGI and appears in the FC name server but cannot establish a usable session with the storage target. Which statement most accurately explains this scenario?
- WWPN zoning and IP access lists are interchangeable security primitives.
- Every storage protocol provides the same file and block semantics.
- Fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets.
- A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
Explanation
Correct Answer
C:This explains why the most appropriate response is to trace PLOGI and PRLI exchange, zoning and target access to isolate the missing FC session phase. Validation depends on fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
Incorrect Answers
A:WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for pLOGI and PRLI storage session. The applicable technical behavior is that fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. The operator should verify fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
B:Every storage protocol provides the same file and block semantics. This is an incorrect generalization for pLOGI and PRLI storage session. The applicable technical behavior is that fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. The operator should verify fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
D:A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for pLOGI and PRLI storage session. The applicable technical behavior is that fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. The operator should verify fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
Question 624
An initiator completes FLOGI and appears in the FC name server but cannot establish a usable session with the storage target. Assume an engineer instead chooses to change only the local interface description to establish PRLI. What is the principal technical consequence of the mistaken choice?
- A well-documented host multipath test is the source of the original fabric fault.
- Examining FCNS entries automatically removes the authorized zoning policy.
- The SAN failed because operators retained correct WWPN identity records.
- Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps.
Explanation
Correct Answer
D:Fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. The proper corrective action is to trace PLOGI and PRLI exchange, zoning and target access to isolate the missing FC session phase.
Incorrect Answers
A:This does not explain the actual pLOGI and PRLI storage session defect after the shortcut. The meaningful failure is that treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps.
B:This does not explain the actual pLOGI and PRLI storage session defect after the shortcut. The relevant evidence is fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
C:This does not explain the actual pLOGI and PRLI storage session defect after the shortcut. The SAN failed because operators retained correct WWPN identity records.
Question 625
An initiator completes FLOGI and appears in the FC name server but cannot establish a usable session with the storage target. The observed failure is: treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. What should the engineer do to recover and validate the service?
- Resolve port or process login blockage and validate host LUN visibility and I/O.
- Assume a successful ARP reply proves Fibre Channel SCSI login.
- Disable every target ACL before identifying whether the login itself failed.
- Change only the local interface description to establish PRLI.
Explanation
Correct Answer
A:Fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
B:That option would assume a successful ARP reply proves Fibre Channel SCSI login, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
C:That option would disable every target ACL before identifying whether the login itself failed, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
D:Change only the local interface description to establish PRLI. This would not reliably restore service after the stated fault. Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. The controlled recovery is to resolve port or process login blockage and validate host LUN visibility and I/O.
Question 626
A SAN host can discover a target WWPN but SCSI traffic does not start because the upper-level port login or process login fails. Which next step should the data center engineer select?
- On this affected device, the engineer should assume a successful ARP reply proves Fibre Channel SCSI login.
- On this affected device, the engineer should trace PLOGI and PRLI exchange, zoning and target access to isolate the missing FC session phase.
- On this affected device, the engineer should disable every target ACL before identifying whether the login itself failed.
- On this affected device, the engineer should change only the local interface description to establish PRLI.
Explanation
Correct Answer
B:This directly addresses pLOGI and PRLI storage session because fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets.
Incorrect Answers
A:Assume a successful ARP reply proves Fibre Channel SCSI login. The proposed change targets the wrong mechanism or lacks essential validation. Fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. Relevant evidence is fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
C:Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps.
D:Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. Change only the local interface description to establish PRLI.
Question 627
A SAN host can discover a target WWPN but SCSI traffic does not start because the upper-level port login or process login fails. Which diagnostic record would most strongly confirm the result?
- For this deployment, examine a copied zoneset name without its active effective members.
- For this deployment, examine a green physical FC link light without fabric login, zoning or I/O evidence.
- For this deployment, examine fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
- For this deployment, examine an Ethernet ping that does not test the required SAN session or VSAN.
Explanation
Correct Answer
C:These observations test the actual pLOGI and PRLI storage session mechanism rather than a superficial management status. They should be checked after trace PLOGI and PRLI exchange, zoning and target access to isolate the missing FC session phase.
Incorrect Answers
A:This information cannot independently verify pLOGI and PRLI storage session. A copied zoneset name without its active effective members.
B:This information cannot independently verify pLOGI and PRLI storage session. A green physical FC link light without fabric login, zoning or I/O evidence.
D:This information cannot independently verify pLOGI and PRLI storage session. An Ethernet ping that does not test the required SAN session or VSAN.
Question 628
A SAN host can discover a target WWPN but SCSI traffic does not start because the upper-level port login or process login fails. Which platform concept should guide the engineer’s assessment?
- For this condition, the applicable principle is that a lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
- For this condition, the applicable principle is that wWPN zoning and IP access lists are interchangeable security primitives.
- For this condition, the applicable principle is that Fibre Channel name service entries are identical to host multipath device state.
- For this condition, the applicable principle is that fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets.
Explanation
Correct Answer
D:This explains why the most appropriate response is to trace PLOGI and PRLI exchange, zoning and target access to isolate the missing FC session phase.
Incorrect Answers
A:A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for pLOGI and PRLI storage session. The applicable technical behavior is that fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. The operator should verify fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
B:WWPN zoning and IP access lists are interchangeable security primitives. This is an incorrect generalization for pLOGI and PRLI storage session. The applicable technical behavior is that fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. The operator should verify fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
C:Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for pLOGI and PRLI storage session. The applicable technical behavior is that fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. The operator should verify fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
Question 629
A SAN host can discover a target WWPN but SCSI traffic does not start because the upper-level port login or process login fails. Assume an engineer instead chooses to change only the local interface description to establish PRLI. Which root-cause observation follows from that incorrect change?
- The resulting defect is that treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps.
- The resulting defect is that the SAN failed because operators retained correct WWPN identity records.
- The resulting defect is that the sole error was using a verified SAN maintenance window for a risky operation.
- The resulting defect is that examining FCNS entries automatically removes the authorized zoning policy.
Explanation
Correct Answer
A:Fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
B:This does not explain the actual pLOGI and PRLI storage session defect after the shortcut. In the given case, a SAN host can discover a target WWPN but SCSI traffic does not start because the upper-level port login or process login fails.
C:This does not explain the actual pLOGI and PRLI storage session defect after the shortcut. The sole error was using a verified SAN maintenance window for a risky operation.
D:This does not explain the actual pLOGI and PRLI storage session defect after the shortcut. Examining FCNS entries automatically removes the authorized zoning policy.
Question 630
A SAN host can discover a target WWPN but SCSI traffic does not start because the upper-level port login or process login fails. The observed failure is: treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to disable every target ACL before identifying whether the login itself failed.
- The controlled remediation is to resolve port or process login blockage and validate host LUN visibility and I/O.
- The controlled remediation is to change only the local interface description to establish PRLI.
- The controlled remediation is to assume a successful ARP reply proves Fibre Channel SCSI login.
Explanation
Correct Answer
B:Fabric login grants FC access to the fabric; subsequent port and process login establish communication with specific targets. Validate against fLOGI, PLOGI and PRLI status, target WWPN, fabric zoning and storage port login logs.
Incorrect Answers
A:Disable every target ACL before identifying whether the login itself failed. This would not reliably restore service after the stated fault. Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. The controlled recovery is to resolve port or process login blockage and validate host LUN visibility and I/O.
C:Change only the local interface description to establish PRLI. This would not reliably restore service after the stated fault. Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. The controlled recovery is to resolve port or process login blockage and validate host LUN visibility and I/O.
D:Assume a successful ARP reply proves Fibre Channel SCSI login. This would not reliably restore service after the stated fault. Treating FLOGI as proof of an operational host-to-storage exchange overlooks later login and authorization steps. The controlled recovery is to resolve port or process login blockage and validate host LUN visibility and I/O.