Cisco 350-601 Practice Test 62
Question 610
An expanded Fibre Channel fabric requires stable domain allocation but added switches have conflicting domain ID preferences. The observed failure is: conflicting domain settings can prevent stable fabric merges and Fibre Channel address assignment. Which remediation most directly restores the intended behavior?
- The controlled remediation is to disable every ISL to suppress visible duplicate domain alerts.
- The controlled remediation is to resolve domain configuration under change control and verify stable fabric initialization and device login.
- The controlled remediation is to assign the same fixed domain ID to every MDS switch in a joined fabric.
- The controlled remediation is to set a switch DNS name to override Fibre Channel principal elections.
Explanation
Correct Answer
B:Validate against fabric domain IDs, principal switch status, VSAN state and stable switch-to-switch link initialization. Fibre Channel fabric initialization requires coherent domain management so FC addresses remain unique.
Incorrect Answers
A:Disable every ISL to suppress visible duplicate domain alerts. This would not reliably restore service after the stated fault. Conflicting domain settings can prevent stable fabric merges and Fibre Channel address assignment. The controlled recovery is to resolve domain configuration under change control and verify stable fabric initialization and device login.
C:Assign the same fixed domain ID to every MDS switch in a joined fabric. This would not reliably restore service after the stated fault. Conflicting domain settings can prevent stable fabric merges and Fibre Channel address assignment. The controlled recovery is to resolve domain configuration under change control and verify stable fabric initialization and device login.
D:Set a switch DNS name to override Fibre Channel principal elections. This would not reliably restore service after the stated fault. Conflicting domain settings can prevent stable fabric merges and Fibre Channel address assignment. The controlled recovery is to resolve domain configuration under change control and verify stable fabric initialization and device login.
Question 611
A server HBA has a physical FC link but no Fibre Channel address after fabric login fails. Which configuration decision MOST directly resolves the issue?
- Create an NFS export to assign an FCID to a Fibre Channel HBA.
- Use a host's IPv4 DHCP lease as the FCID.
- Investigate FLOGI exchange and fabric-domain address allocation before troubleshooting storage LUN masking.
- Ignore FLOGI errors because the optical link LED is lit.
Explanation
Correct Answer
C:This directly addresses FCID allocation after FLOGI because FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. Confirm the change against fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
Incorrect Answers
A:A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The relevant correction is to investigate FLOGI exchange and fabric-domain address allocation before troubleshooting storage LUN masking.
B:Use a host's IPv4 DHCP lease as the FCID. The proposed change targets the wrong mechanism or lacks essential validation. FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. Relevant evidence is fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
D:A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The appropriate action remains to investigate FLOGI exchange and fabric-domain address allocation before troubleshooting storage LUN masking.
Question 612
A server HBA has a physical FC link but no Fibre Channel address after fabric login fails. What should the engineer inspect to confirm the actual state?
- A historical FC topology drawing with no current WWPN or port state.
- A storage vendor slogan without the relevant login and path counters.
- A copied zoneset name without its active effective members.
- FLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
Explanation
Correct Answer
D:These observations test the actual FCID allocation after FLOGI mechanism rather than a superficial management status. FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login.
Incorrect Answers
A:This information cannot independently verify FCID allocation after FLOGI. The decisive records instead include fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
B:This information cannot independently verify FCID allocation after FLOGI. FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login.
C:This information cannot independently verify FCID allocation after FLOGI. A copied zoneset name without its active effective members.
Question 613
A server HBA has a physical FC link but no Fibre Channel address after fabric login fails. What technical behavior underlies the correct decision?
- FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login.
- Every storage protocol provides the same file and block semantics.
- Fibre Channel name service entries are identical to host multipath device state.
- An unused VSAN number can replace an active zoning or port security rule.
Explanation
Correct Answer
A:This explains why the most appropriate response is to investigate FLOGI exchange and fabric-domain address allocation before troubleshooting storage LUN masking. Validation depends on fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
Incorrect Answers
B:Every storage protocol provides the same file and block semantics. This is an incorrect generalization for FCID allocation after FLOGI. The applicable technical behavior is that FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. The operator should verify fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
C:Fibre Channel name service entries are identical to host multipath device state. This is an incorrect generalization for FCID allocation after FLOGI. The applicable technical behavior is that FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. The operator should verify fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
D:An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for FCID allocation after FLOGI. The applicable technical behavior is that FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. The operator should verify fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
Question 614
A server HBA has a physical FC link but no Fibre Channel address after fabric login fails. Assume an engineer instead chooses to create an NFS export to assign an FCID to a Fibre Channel HBA. Which resulting risk or fault should the reviewer identify?
- The sole error was using a verified SAN maintenance window for a risky operation.
- A device without successful fabric login cannot reliably participate in normal FC name service or target discovery.
- Inspecting credit counters prevents FC frames from forwarding.
- A well-documented host multipath test is the source of the original fabric fault.
Explanation
Correct Answer
B:FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual FCID allocation after FLOGI defect after the shortcut. The meaningful failure is that a device without successful fabric login cannot reliably participate in normal FC name service or target discovery.
C:This does not explain the actual FCID allocation after FLOGI defect after the shortcut. The relevant evidence is fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
D:This does not explain the actual FCID allocation after FLOGI defect after the shortcut. In the given case, a server HBA has a physical FC link but no Fibre Channel address after fabric login fails.
Question 615
A server HBA has a physical FC link but no Fibre Channel address after fabric login fails. The observed failure is: a device without successful fabric login cannot reliably participate in normal FC name service or target discovery. Which remediation most directly restores the intended behavior?
- Use a host's IPv4 DHCP lease as the FCID.
- Ignore FLOGI errors because the optical link LED is lit.
- Repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
- Create an NFS export to assign an FCID to a Fibre Channel HBA.
Explanation
Correct Answer
C:FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
A:Use a host's IPv4 DHCP lease as the FCID. This would not reliably restore service after the stated fault. A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The controlled recovery is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
B:Ignore FLOGI errors because the optical link LED is lit. This would not reliably restore service after the stated fault. A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The controlled recovery is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
D:That option would create an NFS export to assign an FCID to a Fibre Channel HBA, but it addresses a different concern. This addresses the observable fault while preserving a check of the expected result.
Question 616
An MDS switch port is up but the connected initiator never receives the expected FCID through fabric login. Which operator action best meets this technical requirement?
- On this affected device, the engineer should use a host's IPv4 DHCP lease as the FCID.
- On this affected device, the engineer should ignore FLOGI errors because the optical link LED is lit.
- On this affected device, the engineer should create an NFS export to assign an FCID to a Fibre Channel HBA.
- On this affected device, the engineer should investigate FLOGI exchange and fabric-domain address allocation before troubleshooting storage LUN masking.
Explanation
Correct Answer
D:This directly addresses FCID allocation after FLOGI because FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login.
Incorrect Answers
A:Use a host's IPv4 DHCP lease as the FCID. The proposed change targets the wrong mechanism or lacks essential validation. FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. Relevant evidence is fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
B:A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. Ignore FLOGI errors because the optical link LED is lit.
C:A device without successful fabric login cannot reliably participate in normal FC name service or target discovery.
Question 617
An MDS switch port is up but the connected initiator never receives the expected FCID through fabric login. Which collection of observations most directly tests the suspected cause?
- For this deployment, examine fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
- For this deployment, examine a green physical FC link light without fabric login, zoning or I/O evidence.
- For this deployment, examine a historical FC topology drawing with no current WWPN or port state.
- For this deployment, examine a storage vendor slogan without the relevant login and path counters.
Explanation
Correct Answer
A:These observations test the actual FCID allocation after FLOGI mechanism rather than a superficial management status. They should be checked after investigate FLOGI exchange and fabric-domain address allocation before troubleshooting storage LUN masking.
Incorrect Answers
B:This information cannot independently verify FCID allocation after FLOGI. A green physical FC link light without fabric login, zoning or I/O evidence.
C:This information cannot independently verify FCID allocation after FLOGI. In the given case, an MDS switch port is up but the connected initiator never receives the expected FCID through fabric login.
D:This information cannot independently verify FCID allocation after FLOGI. A storage vendor slogan without the relevant login and path counters.
Question 618
An MDS switch port is up but the connected initiator never receives the expected FCID through fabric login. Which statement most accurately explains this scenario?
- For this condition, the applicable principle is that an unused VSAN number can replace an active zoning or port security rule.
- For this condition, the applicable principle is that FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login.
- For this condition, the applicable principle is that every storage protocol provides the same file and block semantics.
- For this condition, the applicable principle is that a lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O.
Explanation
Correct Answer
B:This explains why the most appropriate response is to investigate FLOGI exchange and fabric-domain address allocation before troubleshooting storage LUN masking.
Incorrect Answers
A:An unused VSAN number can replace an active zoning or port security rule. This is an incorrect generalization for FCID allocation after FLOGI. The applicable technical behavior is that FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. The operator should verify fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
C:Every storage protocol provides the same file and block semantics. This is an incorrect generalization for FCID allocation after FLOGI. The applicable technical behavior is that FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. The operator should verify fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
D:A lit Fibre Channel link proves end-to-end LUN visibility and authorized I/O. This is an incorrect generalization for FCID allocation after FLOGI. The applicable technical behavior is that FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. The operator should verify fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
Question 619
An MDS switch port is up but the connected initiator never receives the expected FCID through fabric login. Assume an engineer instead chooses to create an NFS export to assign an FCID to a Fibre Channel HBA. What is the principal technical consequence of the mistaken choice?
- The resulting defect is that a well-documented host multipath test is the source of the original fabric fault.
- The resulting defect is that examining FCNS entries automatically removes the authorized zoning policy.
- The resulting defect is that a device without successful fabric login cannot reliably participate in normal FC name service or target discovery.
- The resulting defect is that inspecting credit counters prevents FC frames from forwarding.
Explanation
Correct Answer
C:FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. The proper corrective action is to investigate FLOGI exchange and fabric-domain address allocation before troubleshooting storage LUN masking.
Incorrect Answers
A:This does not explain the actual FCID allocation after FLOGI defect after the shortcut. In the given case, an MDS switch port is up but the connected initiator never receives the expected FCID through fabric login.
B:This does not explain the actual FCID allocation after FLOGI defect after the shortcut. Examining FCNS entries automatically removes the authorized zoning policy.
D:The meaningful failure is that a device without successful fabric login cannot reliably participate in normal FC name service or target discovery.
Question 620
An MDS switch port is up but the connected initiator never receives the expected FCID through fabric login. The observed failure is: a device without successful fabric login cannot reliably participate in normal FC name service or target discovery. What should the engineer do to recover and validate the service?
- The controlled remediation is to ignore FLOGI errors because the optical link LED is lit.
- The controlled remediation is to create an NFS export to assign an FCID to a Fibre Channel HBA.
- The controlled remediation is to use a host's IPv4 DHCP lease as the FCID.
- The controlled remediation is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
Explanation
Correct Answer
D:FCIDs are assigned through Fibre Channel fabric services; link state alone does not complete login. Validate against fLOGI database entries, FCID assignment, port role and initiator WWPN visibility.
Incorrect Answers
A:Ignore FLOGI errors because the optical link LED is lit. This would not reliably restore service after the stated fault. A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The controlled recovery is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
B:Create an NFS export to assign an FCID to a Fibre Channel HBA. This would not reliably restore service after the stated fault. A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The controlled recovery is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.
C:Use a host's IPv4 DHCP lease as the FCID. This would not reliably restore service after the stated fault. A device without successful fabric login cannot reliably participate in normal FC name service or target discovery. The controlled recovery is to repair port and fabric login prerequisites and confirm assigned FCID and FCNS registration.