Cisco 350-601 Practice Test 27
Question 260
A change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot. The observed failure is: treating any version jump as nondisruptive can cause unexpected traffic loss in production. What should the engineer do to recover and validate the service?
- The controlled remediation is to ignore release caveats and disable rollback images before installation.
- The controlled remediation is to promise zero downtime solely because the file is called an NX-OS image.
- The controlled remediation is to change a VRF name to make every upgrade nondisruptive.
- The controlled remediation is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
Explanation
Correct Answer
D:ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee. Validate against supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
Incorrect Answers
A:Ignore release caveats and disable rollback images before installation. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
B:Promise zero downtime solely because the file is called an NX-OS image. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
C:Change a VRF name to make every upgrade nondisruptive. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
Question 261
An engineer upgrades EPLD components on a Nexus line card without accounting for potential module resets. Which operator action best meets this technical requirement?
- Read the exact EPLD impact notes and plan affected-module service interruption and recovery.
- Install EPLD files as if they were ordinary text configuration templates.
- Ignore module redundancy because firmware updates cannot affect traffic.
- Erase a switch checkpoint before evaluating the firmware procedure.
Explanation
Correct Answer
A:This directly addresses ePLD firmware risk because ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software. Confirm the change against platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
Incorrect Answers
B:Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. The relevant correction is to read the exact EPLD impact notes and plan affected-module service interruption and recovery.
C:Ignore module redundancy because firmware updates cannot affect traffic. The proposed change targets the wrong mechanism or lacks essential validation. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software. Relevant evidence is platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
D:Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. The appropriate action remains to read the exact EPLD impact notes and plan affected-module service interruption and recovery.
Question 262
An engineer upgrades EPLD components on a Nexus line card without accounting for potential module resets. Which collection of observations most directly tests the suspected cause?
- One successful ping to an unrelated management address.
- Platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
- An interface description without the effective peer or VXLAN policy.
- A healthy optical light without checking protocol neighbors or forwarding entries.
Explanation
Correct Answer
B:These observations test the actual ePLD firmware risk mechanism rather than a superficial management status. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
Incorrect Answers
A:One successful ping to an unrelated management address. This information cannot independently verify ePLD firmware risk. The decisive records instead include platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
C:An interface description without the effective peer or VXLAN policy. This information cannot independently verify ePLD firmware risk. The decisive records instead include platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
D:A healthy optical light without checking protocol neighbors or forwarding entries. This information cannot independently verify ePLD firmware risk. The decisive records instead include platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
Question 263
An engineer upgrades EPLD components on a Nexus line card without accounting for potential module resets. Which statement most accurately explains this scenario?
- A device description always determines actual forwarding policy regardless of running configuration.
- All control-plane protocols exchange state automatically after a cable is inserted.
- EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
- Configuration differences between peer switches cannot affect network traffic.
Explanation
Correct Answer
C:Validation depends on platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. This explains why the most appropriate response is to read the exact EPLD impact notes and plan affected-module service interruption and recovery.
Incorrect Answers
A:A device description always determines actual forwarding policy regardless of running configuration. This is an incorrect generalization for ePLD firmware risk. The applicable technical behavior is that ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software. The operator should verify platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
B:All control-plane protocols exchange state automatically after a cable is inserted. This is an incorrect generalization for ePLD firmware risk. The applicable technical behavior is that ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software. The operator should verify platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
D:Configuration differences between peer switches cannot affect network traffic. This is an incorrect generalization for ePLD firmware risk. The applicable technical behavior is that ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software. The operator should verify platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
Question 264
An engineer upgrades EPLD components on a Nexus line card without accounting for potential module resets. Assume an engineer instead chooses to install EPLD files as if they were ordinary text configuration templates. What is the principal technical consequence of the mistaken choice?
- The only consequence of the wrong change is a different device description.
- Verifying topology after maintenance automatically creates a switching loop.
- The defect exists solely because the engineer documented the change.
- Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption.
Explanation
Correct Answer
D:EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual ePLD firmware risk defect after the shortcut. The meaningful failure is that assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption.
B:This does not explain the actual ePLD firmware risk defect after the shortcut. The relevant evidence is platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
C:This does not explain the actual ePLD firmware risk defect after the shortcut. The defect exists solely because the engineer documented the change.
Question 265
An engineer upgrades EPLD components on a Nexus line card without accounting for potential module resets. The observed failure is: assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. What should the engineer do to recover and validate the service?
- Schedule supported EPLD procedure, protect redundant paths, and test impacted interfaces afterward.
- Ignore module redundancy because firmware updates cannot affect traffic.
- Erase a switch checkpoint before evaluating the firmware procedure.
- Install EPLD files as if they were ordinary text configuration templates.
Explanation
Correct Answer
A:Validate against platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
B:Ignore module redundancy because firmware updates cannot affect traffic. This would not reliably restore service after the stated fault. Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. The controlled recovery is to schedule supported EPLD procedure, protect redundant paths, and test impacted interfaces afterward.
C:Erase a switch checkpoint before evaluating the firmware procedure. This would not reliably restore service after the stated fault. Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. The controlled recovery is to schedule supported EPLD procedure, protect redundant paths, and test impacted interfaces afterward.
D:Install EPLD files as if they were ordinary text configuration templates. This would not reliably restore service after the stated fault. Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. The controlled recovery is to schedule supported EPLD procedure, protect redundant paths, and test impacted interfaces afterward.
Question 266
A maintenance review discovers that a hardware-programmable logic update may interrupt forwarding despite a stable NX-OS release. Which next step should the data center engineer select?
- On this affected device, the engineer should ignore module redundancy because firmware updates cannot affect traffic.
- On this affected device, the engineer should read the exact EPLD impact notes and plan affected-module service interruption and recovery.
- On this affected device, the engineer should erase a switch checkpoint before evaluating the firmware procedure.
- On this affected device, the engineer should install EPLD files as if they were ordinary text configuration templates.
Explanation
Correct Answer
B:This directly addresses ePLD firmware risk because ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
Incorrect Answers
A:Ignore module redundancy because firmware updates cannot affect traffic. The proposed change targets the wrong mechanism or lacks essential validation. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software. Relevant evidence is platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
C:Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. Erase a switch checkpoint before evaluating the firmware procedure.
D:Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. Install EPLD files as if they were ordinary text configuration templates.
Question 267
A maintenance review discovers that a hardware-programmable logic update may interrupt forwarding despite a stable NX-OS release. Which diagnostic record would most strongly confirm the result?
- For this deployment, examine an up management interface without the relevant routing or forwarding table.
- For this deployment, examine one successful ping to an unrelated management address.
- For this deployment, examine platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
- For this deployment, examine an interface description without the effective peer or VXLAN policy.
Explanation
Correct Answer
C:These observations test the actual ePLD firmware risk mechanism rather than a superficial management status. They should be checked after read the exact EPLD impact notes and plan affected-module service interruption and recovery.
Incorrect Answers
A:An up management interface without the relevant routing or forwarding table. This information cannot independently verify ePLD firmware risk. The decisive records instead include platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
B:One successful ping to an unrelated management address. This information cannot independently verify ePLD firmware risk. The decisive records instead include platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
D:An interface description without the effective peer or VXLAN policy. This information cannot independently verify ePLD firmware risk. The decisive records instead include platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
Question 268
A maintenance review discovers that a hardware-programmable logic update may interrupt forwarding despite a stable NX-OS release. Which platform concept should guide the engineer’s assessment?
- For this condition, the applicable principle is that configuration differences between peer switches cannot affect network traffic.
- For this condition, the applicable principle is that a device description always determines actual forwarding policy regardless of running configuration.
- For this condition, the applicable principle is that physical link carrier guarantees all overlay and routing states are correct.
- For this condition, the applicable principle is that ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
Explanation
Correct Answer
D:Validation depends on platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
Incorrect Answers
A:Configuration differences between peer switches cannot affect network traffic. This is an incorrect generalization for ePLD firmware risk. The applicable technical behavior is that ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software. The operator should verify platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
B:A device description always determines actual forwarding policy regardless of running configuration. This is an incorrect generalization for ePLD firmware risk. The applicable technical behavior is that ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software. The operator should verify platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
C:Physical link carrier guarantees all overlay and routing states are correct. This is an incorrect generalization for ePLD firmware risk. The applicable technical behavior is that ePLD updates modify hardware logic components and may have disruption characteristics distinct from system software. The operator should verify platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks.
Question 269
A maintenance review discovers that a hardware-programmable logic update may interrupt forwarding despite a stable NX-OS release. Assume an engineer instead chooses to install EPLD files as if they were ordinary text configuration templates. Which root-cause observation follows from that incorrect change?
- The resulting defect is that assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption.
- The resulting defect is that the defect exists solely because the engineer documented the change.
- The resulting defect is that preserving neighbor-state evidence is itself the source of the observed outage.
- The resulting defect is that verifying topology after maintenance automatically creates a switching loop.
Explanation
Correct Answer
A:EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software. The proper corrective action is to read the exact EPLD impact notes and plan affected-module service interruption and recovery.
Incorrect Answers
B:This does not explain the actual ePLD firmware risk defect after the shortcut. In the given case, a maintenance review discovers that a hardware-programmable logic update may interrupt forwarding despite a stable NX-OS release.
C:This does not explain the actual ePLD firmware risk defect after the shortcut. Preserving neighbor-state evidence is itself the source of the observed outage.
D:This does not explain the actual ePLD firmware risk defect after the shortcut. Verifying topology after maintenance automatically creates a switching loop.
Question 270
A maintenance review discovers that a hardware-programmable logic update may interrupt forwarding despite a stable NX-OS release. The observed failure is: assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. Which recovery action addresses the underlying technical fault?
- The controlled remediation is to erase a switch checkpoint before evaluating the firmware procedure.
- The controlled remediation is to schedule supported EPLD procedure, protect redundant paths, and test impacted interfaces afterward.
- The controlled remediation is to install EPLD files as if they were ordinary text configuration templates.
- The controlled remediation is to ignore module redundancy because firmware updates cannot affect traffic.
Explanation
Correct Answer
B:Validate against platform EPLD package version, release notes, affected components, and redundancy and traffic impact checks. EPLD updates modify hardware logic components and may have disruption characteristics distinct from system software.
Incorrect Answers
A:Erase a switch checkpoint before evaluating the firmware procedure. This would not reliably restore service after the stated fault. Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. The controlled recovery is to schedule supported EPLD procedure, protect redundant paths, and test impacted interfaces afterward.
C:Install EPLD files as if they were ordinary text configuration templates. This would not reliably restore service after the stated fault. Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. The controlled recovery is to schedule supported EPLD procedure, protect redundant paths, and test impacted interfaces afterward.
D:Ignore module redundancy because firmware updates cannot affect traffic. This would not reliably restore service after the stated fault. Assuming EPLD updates are merely configuration changes can cause unplanned module or port interruption. The controlled recovery is to schedule supported EPLD procedure, protect redundant paths, and test impacted interfaces afterward.