Cisco 350-601 Practice Test 26
Question 250
A private data center team labels a community-cloud environment as public simply because multiple organizations share infrastructure. The observed failure is: conflating service and deployment models produces mistaken design and operational responsibility assumptions. Which remediation most directly restores the intended behavior?
- The controlled remediation is to define every hosted application as public cloud regardless of access and ownership.
- The controlled remediation is to document both model dimensions and confirm the shared-responsibility boundaries for the design.
- The controlled remediation is to assume any virtual machine always implies a SaaS offering.
- The controlled remediation is to declare that hybrid cloud means only two VLANs on one switch.
Explanation
Correct Answer
B:IaaS, PaaS and SaaS describe service abstractions, while public, private, community and hybrid describe deployment arrangements. Validate against which layer the consumer manages, deployment ownership and access model, and NIST SP 800-145 terminology.
Incorrect Answers
A:Define every hosted application as public cloud regardless of access and ownership. This would not reliably restore service after the stated fault. Conflating service and deployment models produces mistaken design and operational responsibility assumptions. The controlled recovery is to document both model dimensions and confirm the shared-responsibility boundaries for the design.
C:Assume any virtual machine always implies a SaaS offering. This would not reliably restore service after the stated fault. Conflating service and deployment models produces mistaken design and operational responsibility assumptions. The controlled recovery is to document both model dimensions and confirm the shared-responsibility boundaries for the design.
D:Declare that hybrid cloud means only two VLANs on one switch. This would not reliably restore service after the stated fault. Conflating service and deployment models produces mistaken design and operational responsibility assumptions. The controlled recovery is to document both model dimensions and confirm the shared-responsibility boundaries for the design.
Question 251
A Nexus maintenance plan assumes an ISSU will be nondisruptive without checking the target-image compatibility matrix. Which configuration decision MOST directly resolves the issue?
- Promise zero downtime solely because the file is called an NX-OS image.
- Change a VRF name to make every upgrade nondisruptive.
- Check the platform-specific NX-OS upgrade and ISSU support matrix plus active feature prerequisites before approving the method.
- Ignore release caveats and disable rollback images before installation.
Explanation
Correct Answer
C:This directly addresses NX-OS in-service upgrade eligibility because iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee. Confirm the change against supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
Incorrect Answers
A:Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The relevant correction is to check the platform-specific NX-OS upgrade and ISSU support matrix plus active feature prerequisites before approving the method.
B:Change a VRF name to make every upgrade nondisruptive. The proposed change targets the wrong mechanism or lacks essential validation. ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee. Relevant evidence is supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
D:Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The appropriate action remains to check the platform-specific NX-OS upgrade and ISSU support matrix plus active feature prerequisites before approving the method.
Question 252
A Nexus maintenance plan assumes an ISSU will be nondisruptive without checking the target-image compatibility matrix. What should the engineer inspect to confirm the actual state?
- A pre-change network diagram with no live control-plane state.
- A healthy optical light without checking protocol neighbors or forwarding entries.
- An up management interface without the relevant routing or forwarding table.
- Supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
Explanation
Correct Answer
D:These observations test the actual NX-OS in-service upgrade eligibility mechanism rather than a superficial management status. ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee.
Incorrect Answers
A:This information cannot independently verify NX-OS in-service upgrade eligibility. The decisive records instead include supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
B:This information cannot independently verify NX-OS in-service upgrade eligibility. ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee.
C:This information cannot independently verify NX-OS in-service upgrade eligibility. An up management interface without the relevant routing or forwarding table.
Question 253
A Nexus maintenance plan assumes an ISSU will be nondisruptive without checking the target-image compatibility matrix. What technical behavior underlies the correct decision?
- ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee.
- All control-plane protocols exchange state automatically after a cable is inserted.
- Physical link carrier guarantees all overlay and routing states are correct.
- A working management-plane ping proves every tenant and application path is healthy.
Explanation
Correct Answer
A:Validation depends on supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan. This explains why the most appropriate response is to check the platform-specific NX-OS upgrade and ISSU support matrix plus active feature prerequisites before approving the method.
Incorrect Answers
B:All control-plane protocols exchange state automatically after a cable is inserted. This is an incorrect generalization for NX-OS in-service upgrade eligibility. The applicable technical behavior is that iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee. The operator should verify supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
C:Physical link carrier guarantees all overlay and routing states are correct. This is an incorrect generalization for NX-OS in-service upgrade eligibility. The applicable technical behavior is that iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee. The operator should verify supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
D:A working management-plane ping proves every tenant and application path is healthy. This is an incorrect generalization for NX-OS in-service upgrade eligibility. The applicable technical behavior is that iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee. The operator should verify supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
Question 254
A Nexus maintenance plan assumes an ISSU will be nondisruptive without checking the target-image compatibility matrix. Assume an engineer instead chooses to promise zero downtime solely because the file is called an NX-OS image. Which resulting risk or fault should the reviewer identify?
- Preserving neighbor-state evidence is itself the source of the observed outage.
- Treating any version jump as nondisruptive can cause unexpected traffic loss in production.
- Investigating the forwarding table is the reason a broken route cannot converge.
- The only consequence of the wrong change is a different device description.
Explanation
Correct Answer
B:ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee. That is the direct consequence of choosing the misleading shortcut.
Incorrect Answers
A:This does not explain the actual NX-OS in-service upgrade eligibility defect after the shortcut. The meaningful failure is that treating any version jump as nondisruptive can cause unexpected traffic loss in production.
C:This does not explain the actual NX-OS in-service upgrade eligibility defect after the shortcut. The relevant evidence is supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
D:This does not explain the actual NX-OS in-service upgrade eligibility defect after the shortcut. The only consequence of the wrong change is a different device description.
Question 255
A Nexus maintenance plan assumes an ISSU will be nondisruptive without checking the target-image compatibility matrix. The observed failure is: treating any version jump as nondisruptive can cause unexpected traffic loss in production. Which remediation most directly restores the intended behavior?
- Change a VRF name to make every upgrade nondisruptive.
- Ignore release caveats and disable rollback images before installation.
- Choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
- Promise zero downtime solely because the file is called an NX-OS image.
Explanation
Correct Answer
C:ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee. This addresses the observable fault while preserving a check of the expected result.
Incorrect Answers
A:Change a VRF name to make every upgrade nondisruptive. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
B:Ignore release caveats and disable rollback images before installation. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
D:Promise zero downtime solely because the file is called an NX-OS image. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
Question 256
A change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot. Which operator action best meets this technical requirement?
- On this affected device, the engineer should change a VRF name to make every upgrade nondisruptive.
- On this affected device, the engineer should ignore release caveats and disable rollback images before installation.
- On this affected device, the engineer should promise zero downtime solely because the file is called an NX-OS image.
- On this affected device, the engineer should check the platform-specific NX-OS upgrade and ISSU support matrix plus active feature prerequisites before approving the method.
Explanation
Correct Answer
D:This directly addresses NX-OS in-service upgrade eligibility because iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee.
Incorrect Answers
A:Change a VRF name to make every upgrade nondisruptive. The proposed change targets the wrong mechanism or lacks essential validation. ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee. Relevant evidence is supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
B:Treating any version jump as nondisruptive can cause unexpected traffic loss in production. In the given case, a change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot.
C:Treating any version jump as nondisruptive can cause unexpected traffic loss in production. Promise zero downtime solely because the file is called an NX-OS image.
Question 257
A change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot. Which collection of observations most directly tests the suspected cause?
- For this deployment, examine supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
- For this deployment, examine one successful ping to an unrelated management address.
- For this deployment, examine a pre-change network diagram with no live control-plane state.
- For this deployment, examine a healthy optical light without checking protocol neighbors or forwarding entries.
Explanation
Correct Answer
A:These observations test the actual NX-OS in-service upgrade eligibility mechanism rather than a superficial management status. They should be checked after check the platform-specific NX-OS upgrade and ISSU support matrix plus active feature prerequisites before approving the method.
Incorrect Answers
B:This information cannot independently verify NX-OS in-service upgrade eligibility. In the given case, a change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot.
C:This information cannot independently verify NX-OS in-service upgrade eligibility. A pre-change network diagram with no live control-plane state.
D:This information cannot independently verify NX-OS in-service upgrade eligibility. A healthy optical light without checking protocol neighbors or forwarding entries.
Question 258
A change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot. Which statement most accurately explains this scenario?
- For this condition, the applicable principle is that a working management-plane ping proves every tenant and application path is healthy.
- For this condition, the applicable principle is that iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee.
- For this condition, the applicable principle is that all control-plane protocols exchange state automatically after a cable is inserted.
- For this condition, the applicable principle is that configuration differences between peer switches cannot affect network traffic.
Explanation
Correct Answer
B:Validation depends on supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
Incorrect Answers
A:A working management-plane ping proves every tenant and application path is healthy. This is an incorrect generalization for NX-OS in-service upgrade eligibility. The applicable technical behavior is that iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee. The operator should verify supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
C:All control-plane protocols exchange state automatically after a cable is inserted. This is an incorrect generalization for NX-OS in-service upgrade eligibility. The applicable technical behavior is that iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee. The operator should verify supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
D:Configuration differences between peer switches cannot affect network traffic. This is an incorrect generalization for NX-OS in-service upgrade eligibility. The applicable technical behavior is that iSSU availability depends on release path, hardware and enabled services rather than a universal guarantee. The operator should verify supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
Question 259
A change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot. Assume an engineer instead chooses to promise zero downtime solely because the file is called an NX-OS image. What is the principal technical consequence of the mistaken choice?
- The resulting defect is that the only consequence of the wrong change is a different device description.
- The resulting defect is that verifying topology after maintenance automatically creates a switching loop.
- The resulting defect is that treating any version jump as nondisruptive can cause unexpected traffic loss in production.
- The resulting defect is that investigating the forwarding table is the reason a broken route cannot converge.
Explanation
Correct Answer
C:ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee. The proper corrective action is to check the platform-specific NX-OS upgrade and ISSU support matrix plus active feature prerequisites before approving the method.
Incorrect Answers
A:This does not explain the actual NX-OS in-service upgrade eligibility defect after the shortcut. In the given case, a change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot.
B:This does not explain the actual NX-OS in-service upgrade eligibility defect after the shortcut. Verifying topology after maintenance automatically creates a switching loop.
D:This does not explain the actual NX-OS in-service upgrade eligibility defect after the shortcut. Investigating the forwarding table is the reason a broken route cannot converge.
Question 260
A change board schedules an upgrade while hardware and active feature combinations may require a disruptive reboot. The observed failure is: treating any version jump as nondisruptive can cause unexpected traffic loss in production. What should the engineer do to recover and validate the service?
- The controlled remediation is to ignore release caveats and disable rollback images before installation.
- The controlled remediation is to promise zero downtime solely because the file is called an NX-OS image.
- The controlled remediation is to change a VRF name to make every upgrade nondisruptive.
- The controlled remediation is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
Explanation
Correct Answer
D:ISSU availability depends on release path, hardware and enabled services rather than a universal guarantee. Validate against supported source and destination releases, platform model, feature state, ISSU impact report, and maintenance plan.
Incorrect Answers
A:Ignore release caveats and disable rollback images before installation. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
B:Promise zero downtime solely because the file is called an NX-OS image. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.
C:Change a VRF name to make every upgrade nondisruptive. This would not reliably restore service after the stated fault. Treating any version jump as nondisruptive can cause unexpected traffic loss in production. The controlled recovery is to choose the supported upgrade path, schedule a maintenance window if needed, and validate post-upgrade neighbors.