cert
cert-1
cert-2

Pass Cisco 300-420 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
300-420 Exam - Verified By Experts
300-420 Premium Bundle
$29.98

300-420 Premium Bundle

$79.99
$109.97
  • Premium File 416 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 75 Video Lectures
  • Study Guide 751 Pages
 
$109.97
$79.99
accept 33 downloads in last 7 days
block-screenshots
Purchase Cisco 300-420 Exam Training Products Individually
Cisco 300-420 Premium File
Premium File 416 Q&A
$76.99$69.99
Cisco 300-420 Video Training Course
Training Course 75 Lectures
$21.99 $19.99
Cisco 300-420 PDF Study Guide
Study Guide 751 Pages
$21.99 $19.99
Cisco 300-420 Practice Test 33

Question 320

A campus wants to restrict east-west traffic within a sensitive VLAN while keeping selected local endpoints reachable. The observed fault is: Relying solely on an SVI ACL can leave same-VLAN lateral traffic uncontrolled. Which controlled remediation should be used?

  1. The controlled recovery is to assume port security MAC limits provide all application-layer VLAN filtering.
  2. The controlled recovery is to apply only an SVI outbound ACL and assume all same-VLAN frames traverse it.
  3. The controlled recovery is to attach the correct VLAN filter or segmentation policy and validate both intra- and inter-VLAN flows.
  4. The controlled recovery is to change a default route to filter packets switching within a VLAN.

Explanation

Correct Answer

C:

VACLs can filter traffic within a VLAN where a router interface ACL may not inspect same-subnet forwarding. Relevant evidence includes VLAN traffic path, VACL attachment, allowed and denied host-to-host packet tests.

Incorrect Answers

A:

Assume port security MAC limits provide all application-layer VLAN filtering. Relying solely on an SVI ACL can leave same-VLAN lateral traffic uncontrolled. Use the controlled remediation: attach the correct VLAN filter or segmentation policy and validate both intra- and inter-VLAN flows.

B:

Apply only an SVI outbound ACL and assume all same-VLAN frames traverse it. Relying solely on an SVI ACL can leave same-VLAN lateral traffic uncontrolled. Use the controlled remediation: attach the correct VLAN filter or segmentation policy and validate both intra- and inter-VLAN flows.

D:

Change a default route to filter packets switching within a VLAN. Relying solely on an SVI ACL can leave same-VLAN lateral traffic uncontrolled. Use the controlled remediation: attach the correct VLAN filter or segmentation policy and validate both intra- and inter-VLAN flows.

Question 321

Two campus sites share a single aggregation router and both lose intersite access when it fails. What is the BEST supported implementation or corrective action?

  1. Design redundant routed intercampus paths with routing adjacency diversity and tested convergence.
  2. Terminate every intersite backup link on the same sole core router.
  3. Assume two cable labels prove paths have separate physical conduits.
  4. Depend on manually edited routes after a core chassis loss while claiming automatic convergence.

Explanation

Correct Answer

A:

Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. This is the specific corrective action for Multicampus routed core convergence path diversity.

Incorrect Answers

B:

Two uplinks into one aggregation box still leave that box as a common point of failure. This change targets the wrong mechanism for Multicampus routed core convergence path diversity.

C:

Assume two cable labels prove paths have separate physical conduits. Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Instead inspect physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

D:

Two uplinks into one aggregation box still leave that box as a common point of failure. Depend on manually edited routes after a core chassis loss while claiming automatic convergence.

Question 322

Two campus sites share a single aggregation router and both lose intersite access when it fails. What should the operator inspect to verify the result?

  1. A marketing claim without measured routing, capacity or failure-domain evidence.
  2. An old network diagram with no current route, policy, or redundancy state.
  3. Physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.
  4. A feature-license screenshot without the required design or acceptance tests.

Explanation

Correct Answer

C:

Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. This evidence observes the actual multicampus routed core convergence path diversity mechanism and its result.

Incorrect Answers

A:

This observation alone cannot establish multicampus routed core convergence path diversity. Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis.

B:

This observation alone cannot establish multicampus routed core convergence path diversity. The decisive evidence instead includes physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

D:

This observation alone cannot establish multicampus routed core convergence path diversity. A feature-license screenshot without the required design or acceptance tests.

Question 323

Two campus sites share a single aggregation router and both lose intersite access when it fails. Which technical statement is MOST accurate for this situation?

  1. A longer IP prefix is always less specific than the default route.
  2. Cloud connectivity automatically removes any requirement for routing or policy.
  3. Any single device automatically guarantees high availability for every site.
  4. Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis.

Explanation

Correct Answer

D:

This is why the appropriate action is design redundant routed intercampus paths with routing adjacency diversity and tested convergence. Confirm it with physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

Incorrect Answers

A:

A longer IP prefix is always less specific than the default route. This is an incorrect generalization for multicampus routed core convergence path diversity. The relevant rule is route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Verify using physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

B:

Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for multicampus routed core convergence path diversity. The relevant rule is route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Verify using physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

C:

Any single device automatically guarantees high availability for every site. This is an incorrect generalization for multicampus routed core convergence path diversity. The relevant rule is route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Verify using physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

Question 324

Two campus sites share a single aggregation router and both lose intersite access when it fails. Suppose the operator instead makes this incorrect change: Terminate every intersite backup link on the same sole core router. What weakness does the mistaken approach introduce?

  1. Two uplinks into one aggregation box still leave that box as a common point of failure.
  2. A healthy unrelated system proves the intended failure domain is protected.
  3. The failure is entirely cosmetic because all control-plane changes are harmless.
  4. Collecting telemetry originally caused the missing route or service outage.

Explanation

Correct Answer

A:

This explains why the proposed shortcut does not solve multicampus routed core convergence path diversity. Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis.

Incorrect Answers

B:

A healthy unrelated system proves the intended failure domain is protected. The actual failure is two uplinks into one aggregation box still leave that box as a common point of failure. Check physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

C:

The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is two uplinks into one aggregation box still leave that box as a common point of failure. Check physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

D:

Collecting telemetry originally caused the missing route or service outage. The actual failure is two uplinks into one aggregation box still leave that box as a common point of failure. Check physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

Question 325

Two campus sites share a single aggregation router and both lose intersite access when it fails. The observed fault is: Two uplinks into one aggregation box still leave that box as a common point of failure. Which recovery is BEST once this fault is identified?

  1. Assume two cable labels prove paths have separate physical conduits.
  2. Depend on manually edited routes after a core chassis loss while claiming automatic convergence.
  3. Diversify the routing topology and verify a site remains reachable during any single designated failure.
  4. Terminate every intersite backup link on the same sole core router.

Explanation

Correct Answer

C:

Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. This corrects the described failure and provides a verifiable outcome.

Incorrect Answers

A:

Assume two cable labels prove paths have separate physical conduits. Two uplinks into one aggregation box still leave that box as a common point of failure. Use the controlled remediation: diversify the routing topology and verify a site remains reachable during any single designated failure.

B:

Depend on manually edited routes after a core chassis loss while claiming automatic convergence. Two uplinks into one aggregation box still leave that box as a common point of failure. Use the controlled remediation: diversify the routing topology and verify a site remains reachable during any single designated failure.

D:

Terminate every intersite backup link on the same sole core router. Two uplinks into one aggregation box still leave that box as a common point of failure. Use the controlled remediation: diversify the routing topology and verify a site remains reachable during any single designated failure.

Question 326

A geographically separated enterprise needs alternate Layer 3 core paths with bounded convergence times. Which operator action most directly resolves this condition?

  1. For this enterprise design, the architect should assume two cable labels prove paths have separate physical conduits.
  2. For this enterprise design, the architect should design redundant routed intercampus paths with routing adjacency diversity and tested convergence.
  3. For this enterprise design, the architect should depend on manually edited routes after a core chassis loss while claiming automatic convergence.
  4. For this enterprise design, the architect should terminate every intersite backup link on the same sole core router.

Explanation

Correct Answer

B:

Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Confirm the result using physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

Incorrect Answers

A:

Assume two cable labels prove paths have separate physical conduits. Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Instead inspect physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

C:

Two uplinks into one aggregation box still leave that box as a common point of failure. In this case, a geographically separated enterprise needs alternate Layer 3 core paths with bounded convergence times.

D:

Two uplinks into one aggregation box still leave that box as a common point of failure. The relevant action is design redundant routed intercampus paths with routing adjacency diversity and tested convergence.

Question 327

A geographically separated enterprise needs alternate Layer 3 core paths with bounded convergence times. Which collection of observations most directly tests the suspected cause?

  1. Inspect the following evidence: one successful ping to an unrelated test host without a path or failover test.
  2. Inspect the following evidence: physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.
  3. Inspect the following evidence: a marketing claim without measured routing, capacity or failure-domain evidence.
  4. Inspect the following evidence: an old network diagram with no current route, policy, or redundancy state.

Explanation

Correct Answer

B:

Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. The intended procedure is design redundant routed intercampus paths with routing adjacency diversity and tested convergence.

Incorrect Answers

A:

This observation alone cannot establish multicampus routed core convergence path diversity. One successful ping to an unrelated test host without a path or failover test.

C:

This observation alone cannot establish multicampus routed core convergence path diversity. A marketing claim without measured routing, capacity or failure-domain evidence.

D:

This observation alone cannot establish multicampus routed core convergence path diversity. In this case, a geographically separated enterprise needs alternate Layer 3 core paths with bounded convergence times.

Question 328

A geographically separated enterprise needs alternate Layer 3 core paths with bounded convergence times. Which system behavior underlies the appropriate response?

  1. The relevant principle is that any single device automatically guarantees high availability for every site.
  2. The relevant principle is that a longer IP prefix is always less specific than the default route.
  3. The relevant principle is that an operational up state alone proves every security and design objective is met.
  4. The relevant principle is that route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis.

Explanation

Correct Answer

D:

This is why the appropriate action is design redundant routed intercampus paths with routing adjacency diversity and tested convergence.

Incorrect Answers

A:

Any single device automatically guarantees high availability for every site. This is an incorrect generalization for multicampus routed core convergence path diversity. The relevant rule is route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Verify using physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

B:

A longer IP prefix is always less specific than the default route. This is an incorrect generalization for multicampus routed core convergence path diversity. The relevant rule is route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Verify using physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

C:

An operational up state alone proves every security and design objective is met. This is an incorrect generalization for multicampus routed core convergence path diversity. The relevant rule is route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Verify using physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

Question 329

A geographically separated enterprise needs alternate Layer 3 core paths with bounded convergence times. Suppose the operator instead makes this incorrect change: Terminate every intersite backup link on the same sole core router. Which failure or risk follows from this shortcut?

  1. The resulting technical fault is that collecting telemetry originally caused the missing route or service outage.
  2. The resulting technical fault is that a correct change-control review makes all WAN carriers fail simultaneously.
  3. The resulting technical fault is that two uplinks into one aggregation box still leave that box as a common point of failure.
  4. The resulting technical fault is that the failure is entirely cosmetic because all control-plane changes are harmless.

Explanation

Correct Answer

C:

This explains why the proposed shortcut does not solve multicampus routed core convergence path diversity. The right response is design redundant routed intercampus paths with routing adjacency diversity and tested convergence.

Incorrect Answers

A:

Collecting telemetry originally caused the missing route or service outage. The actual failure is two uplinks into one aggregation box still leave that box as a common point of failure. Check physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

B:

A correct change-control review makes all WAN carriers fail simultaneously. The actual failure is two uplinks into one aggregation box still leave that box as a common point of failure. Check physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

D:

The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is two uplinks into one aggregation box still leave that box as a common point of failure. Check physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

Question 330

A geographically separated enterprise needs alternate Layer 3 core paths with bounded convergence times. The observed fault is: Two uplinks into one aggregation box still leave that box as a common point of failure. What action most directly restores and validates the intended state?

  1. The controlled recovery is to depend on manually edited routes after a core chassis loss while claiming automatic convergence.
  2. The controlled recovery is to diversify the routing topology and verify a site remains reachable during any single designated failure.
  3. The controlled recovery is to terminate every intersite backup link on the same sole core router.
  4. The controlled recovery is to assume two cable labels prove paths have separate physical conduits.

Explanation

Correct Answer

B:

Route and device redundancy require independent paths and actual protocol recovery rather than duplicate links on one failed chassis. Relevant evidence includes physical and logical topology, IGP neighbors, failure domains, active next hops and reconvergence measurements.

Incorrect Answers

A:

Depend on manually edited routes after a core chassis loss while claiming automatic convergence. Two uplinks into one aggregation box still leave that box as a common point of failure. Use the controlled remediation: diversify the routing topology and verify a site remains reachable during any single designated failure.

C:

Terminate every intersite backup link on the same sole core router. Two uplinks into one aggregation box still leave that box as a common point of failure. Use the controlled remediation: diversify the routing topology and verify a site remains reachable during any single designated failure.

D:

Assume two cable labels prove paths have separate physical conduits. Two uplinks into one aggregation box still leave that box as a common point of failure. Use the controlled remediation: diversify the routing topology and verify a site remains reachable during any single designated failure.

Designing Cisco Enterprise Networks (ENSLD) (300-420) Practice Tests