cert
cert-1
cert-2

Pass Cisco 300-420 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
300-420 Exam - Verified By Experts
300-420 Premium Bundle
$29.98

300-420 Premium Bundle

$79.99
$109.97
  • Premium File 416 Questions & Answers. Last update: Nov 10, 2026
  • Training Course 75 Video Lectures
  • Study Guide 751 Pages
 
$109.97
$79.99
accept 33 downloads in last 7 days
block-screenshots
Purchase Cisco 300-420 Exam Training Products Individually
Cisco 300-420 Premium File
Premium File 416 Q&A
$76.99$69.99
Cisco 300-420 Video Training Course
Training Course 75 Lectures
$21.99 $19.99
Cisco 300-420 PDF Study Guide
Study Guide 751 Pages
$21.99 $19.99
Cisco 300-420 Practice Test 30

Question 290

A campus experiences a unidirectional optic failure and needs to prevent a Layer 2 loop when STP information disappears. The observed fault is: Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. What action most directly restores and validates the intended state?

  1. The controlled recovery is to disable spanning tree so the formerly blocked alternate link always forwards.
  2. The controlled recovery is to treat a one-way fiber fault as if STP BPDUs can never be affected.
  3. The controlled recovery is to use only endpoint port security to replace all inter-switch loop detection.
  4. The controlled recovery is to apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.

Explanation

Correct Answer

D:

Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Relevant evidence includes bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.

Incorrect Answers

A:

Disable spanning tree so the formerly blocked alternate link always forwards. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.

B:

Treat a one-way fiber fault as if STP BPDUs can never be affected. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.

C:

Use only endpoint port security to replace all inter-switch loop detection. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.

Question 291

An access switch has two uplinks to separate distribution switches but standard EtherChannel cannot form across two unrelated control planes. What is the most defensible configuration decision?

  1. Use an appropriate supported multichassis EtherChannel virtualization or routed access model matched to the campus platform.
  2. Configure ordinary LACP across unrelated distribution switches with no shared logical system.
  3. Assume two physical uplinks automatically create one valid LACP aggregate.
  4. Disable spanning tree to hide aggregation incompatibility.

Explanation

Correct Answer

A:

EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. This is the specific corrective action for Multichassis EtherChannel access resiliency.

Incorrect Answers

B:

Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. This change targets the wrong mechanism for Multichassis EtherChannel access resiliency.

C:

Assume two physical uplinks automatically create one valid LACP aggregate. EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Instead inspect port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

D:

Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages.

Question 292

An access switch has two uplinks to separate distribution switches but standard EtherChannel cannot form across two unrelated control planes. Which evidence BEST confirms the actual technical behavior?

  1. A feature-license screenshot without the required design or acceptance tests.
  2. A marketing claim without measured routing, capacity or failure-domain evidence.
  3. Port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.
  4. A hostname inventory without effective configuration or operational measurements.

Explanation

Correct Answer

C:

EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. This evidence observes the actual multichassis EtherChannel access resiliency mechanism and its result.

Incorrect Answers

A:

This observation alone cannot establish multichassis EtherChannel access resiliency. EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design.

B:

This observation alone cannot establish multichassis EtherChannel access resiliency. The decisive evidence instead includes port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

D:

This observation alone cannot establish multichassis EtherChannel access resiliency. A hostname inventory without effective configuration or operational measurements.

Question 293

An access switch has two uplinks to separate distribution switches but standard EtherChannel cannot form across two unrelated control planes. What networking or enterprise network design concept best explains this scenario?

  1. Any single device automatically guarantees high availability for every site.
  2. EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design.
  3. Encryption and segmentation are identical mechanisms and can replace each other.
  4. Cloud connectivity automatically removes any requirement for routing or policy.

Explanation

Correct Answer

B:

This is why the appropriate action is use an appropriate supported multichassis EtherChannel virtualization or routed access model matched to the campus platform. Confirm it with port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

Incorrect Answers

A:

Any single device automatically guarantees high availability for every site. This is an incorrect generalization for multichassis EtherChannel access resiliency. The relevant rule is etherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Verify using port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

C:

Encryption and segmentation are identical mechanisms and can replace each other. This is an incorrect generalization for multichassis EtherChannel access resiliency. The relevant rule is etherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Verify using port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

D:

Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for multichassis EtherChannel access resiliency. The relevant rule is etherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Verify using port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

Question 294

An access switch has two uplinks to separate distribution switches but standard EtherChannel cannot form across two unrelated control planes. Suppose the operator instead makes this incorrect change: Configure ordinary LACP across unrelated distribution switches with no shared logical system. Which resulting fault should the reviewer identify?

  1. The only issue is an inaccurate hostname while traffic paths are unaffected.
  2. A healthy unrelated system proves the intended failure domain is protected.
  3. The failure is entirely cosmetic because all control-plane changes are harmless.
  4. Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages.

Explanation

Correct Answer

D:

EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. This explains why the proposed shortcut does not solve multichassis EtherChannel access resiliency.

Incorrect Answers

A:

The only issue is an inaccurate hostname while traffic paths are unaffected. The actual failure is aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Check port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

B:

A healthy unrelated system proves the intended failure domain is protected. The actual failure is aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Check port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

C:

The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Check port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

Question 295

An access switch has two uplinks to separate distribution switches but standard EtherChannel cannot form across two unrelated control planes. The observed fault is: Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. How should the issue be corrected and verified?

  1. Assume two physical uplinks automatically create one valid LACP aggregate.
  2. Select the matching MEC or Layer 3 model and test chassis and uplink failures.
  3. Disable spanning tree to hide aggregation incompatibility.
  4. Configure ordinary LACP across unrelated distribution switches with no shared logical system.

Explanation

Correct Answer

B:

EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. This corrects the described failure and provides a verifiable outcome.

Incorrect Answers

A:

Assume two physical uplinks automatically create one valid LACP aggregate. Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Use the controlled remediation: select the matching MEC or Layer 3 model and test chassis and uplink failures.

C:

Disable spanning tree to hide aggregation incompatibility. Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Use the controlled remediation: select the matching MEC or Layer 3 model and test chassis and uplink failures.

D:

Configure ordinary LACP across unrelated distribution switches with no shared logical system. Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Use the controlled remediation: select the matching MEC or Layer 3 model and test chassis and uplink failures.

Question 296

An access layer needs redundant uplink capacity without an L2 loop and with simple logical links. What is the BEST supported implementation or corrective action?

  1. For this enterprise design, the architect should assume two physical uplinks automatically create one valid LACP aggregate.
  2. For this enterprise design, the architect should disable spanning tree to hide aggregation incompatibility.
  3. For this enterprise design, the architect should use an appropriate supported multichassis EtherChannel virtualization or routed access model matched to the campus platform.
  4. For this enterprise design, the architect should configure ordinary LACP across unrelated distribution switches with no shared logical system.

Explanation

Correct Answer

C:

EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Confirm the result using port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

Incorrect Answers

A:

Assume two physical uplinks automatically create one valid LACP aggregate. EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Instead inspect port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

B:

Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages.

D:

Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. The relevant action is use an appropriate supported multichassis EtherChannel virtualization or routed access model matched to the campus platform.

Question 297

An access layer needs redundant uplink capacity without an L2 loop and with simple logical links. What should the operator inspect to verify the result?

  1. Inspect the following evidence: an old network diagram with no current route, policy, or redundancy state.
  2. Inspect the following evidence: port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.
  3. Inspect the following evidence: a feature-license screenshot without the required design or acceptance tests.
  4. Inspect the following evidence: a marketing claim without measured routing, capacity or failure-domain evidence.

Explanation

Correct Answer

B:

EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. The intended procedure is use an appropriate supported multichassis EtherChannel virtualization or routed access model matched to the campus platform.

Incorrect Answers

A:

This observation alone cannot establish multichassis EtherChannel access resiliency. In this case, an access layer needs redundant uplink capacity without an L2 loop and with simple logical links.

C:

This observation alone cannot establish multichassis EtherChannel access resiliency. A feature-license screenshot without the required design or acceptance tests.

D:

This observation alone cannot establish multichassis EtherChannel access resiliency. A marketing claim without measured routing, capacity or failure-domain evidence.

Question 298

An access layer needs redundant uplink capacity without an L2 loop and with simple logical links. Which technical statement is MOST accurate for this situation?

  1. The relevant principle is that cloud connectivity automatically removes any requirement for routing or policy.
  2. The relevant principle is that any single device automatically guarantees high availability for every site.
  3. The relevant principle is that etherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design.
  4. The relevant principle is that a longer IP prefix is always less specific than the default route.

Explanation

Correct Answer

C:

This is why the appropriate action is use an appropriate supported multichassis EtherChannel virtualization or routed access model matched to the campus platform.

Incorrect Answers

A:

Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for multichassis EtherChannel access resiliency. The relevant rule is etherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Verify using port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

B:

Any single device automatically guarantees high availability for every site. This is an incorrect generalization for multichassis EtherChannel access resiliency. The relevant rule is etherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Verify using port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

D:

A longer IP prefix is always less specific than the default route. This is an incorrect generalization for multichassis EtherChannel access resiliency. The relevant rule is etherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Verify using port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

Question 299

An access layer needs redundant uplink capacity without an L2 loop and with simple logical links. Suppose the operator instead makes this incorrect change: Configure ordinary LACP across unrelated distribution switches with no shared logical system. What weakness does the mistaken approach introduce?

  1. The resulting technical fault is that aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages.
  2. The resulting technical fault is that the failure is entirely cosmetic because all control-plane changes are harmless.
  3. The resulting technical fault is that collecting telemetry originally caused the missing route or service outage.
  4. The resulting technical fault is that a healthy unrelated system proves the intended failure domain is protected.

Explanation

Correct Answer

A:

EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. The right response is use an appropriate supported multichassis EtherChannel virtualization or routed access model matched to the campus platform.

Incorrect Answers

B:

The failure is entirely cosmetic because all control-plane changes are harmless. The actual failure is aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Check port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

C:

Collecting telemetry originally caused the missing route or service outage. The actual failure is aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Check port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

D:

A healthy unrelated system proves the intended failure domain is protected. The actual failure is aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Check port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

Question 300

An access layer needs redundant uplink capacity without an L2 loop and with simple logical links. The observed fault is: Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Which recovery is BEST once this fault is identified?

  1. The controlled recovery is to disable spanning tree to hide aggregation incompatibility.
  2. The controlled recovery is to configure ordinary LACP across unrelated distribution switches with no shared logical system.
  3. The controlled recovery is to select the matching MEC or Layer 3 model and test chassis and uplink failures.
  4. The controlled recovery is to assume two physical uplinks automatically create one valid LACP aggregate.

Explanation

Correct Answer

C:

EtherChannel requires compatible aggregation peers and multichassis aggregation needs a common supported logical endpoint or alternative routed design. Relevant evidence includes port-channel membership, control-plane domain, link diversity, hash distribution and failure simulation.

Incorrect Answers

A:

Disable spanning tree to hide aggregation incompatibility. Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Use the controlled remediation: select the matching MEC or Layer 3 model and test chassis and uplink failures.

B:

Configure ordinary LACP across unrelated distribution switches with no shared logical system. Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Use the controlled remediation: select the matching MEC or Layer 3 model and test chassis and uplink failures.

D:

Assume two physical uplinks automatically create one valid LACP aggregate. Aggregating links across unrelated switches without a supported multichassis feature can create miswiring and outages. Use the controlled remediation: select the matching MEC or Layer 3 model and test chassis and uplink failures.

Designing Cisco Enterprise Networks (ENSLD) (300-420) Practice Tests