Cisco 300-420 Practice Test 29
Question 280
A campus wants edge ports to become forwarding promptly without risking accidental switch loops. The observed fault is: Using PortFast indiscriminately on switch-to-switch links without protection can allow temporary or persistent loops. Which controlled remediation should be used?
- The controlled recovery is to assume a host-facing access VLAN cannot ever be connected to another switch.
- The controlled recovery is to correct port roles and BPDU Guard and test an unauthorized switch attachment.
- The controlled recovery is to enable PortFast without BPDU Guard on any uplink used for arbitrary switching peers.
- The controlled recovery is to globally disable BPDUs to avoid discovering an accidental loop.
Explanation
Correct Answer
B:BPDU Guard can shut down an edge port that unexpectedly receives spanning-tree BPDUs. Relevant evidence includes portFast mode, BPDU reception, errdisable event and access port recovery procedure.
Incorrect Answers
A:Assume a host-facing access VLAN cannot ever be connected to another switch. Using PortFast indiscriminately on switch-to-switch links without protection can allow temporary or persistent loops. Use the controlled remediation: correct port roles and BPDU Guard and test an unauthorized switch attachment.
C:Enable PortFast without BPDU Guard on any uplink used for arbitrary switching peers. Using PortFast indiscriminately on switch-to-switch links without protection can allow temporary or persistent loops. Use the controlled remediation: correct port roles and BPDU Guard and test an unauthorized switch attachment.
D:Globally disable BPDUs to avoid discovering an accidental loop. Using PortFast indiscriminately on switch-to-switch links without protection can allow temporary or persistent loops. Use the controlled remediation: correct port roles and BPDU Guard and test an unauthorized switch attachment.
Question 281
A fiber trunk stops receiving BPDUs on a blocked alternate path and could incorrectly transition to forwarding. What is the BEST supported implementation or corrective action?
- Treat a one-way fiber fault as if STP BPDUs can never be affected.
- Use only endpoint port security to replace all inter-switch loop detection.
- Disable spanning tree so the formerly blocked alternate link always forwards.
- Use appropriate Loop Guard or UDLD mechanisms on eligible nonedge inter-switch links.
Explanation
Correct Answer
D:Confirm the result using bPDU reception history, loop-inconsistent state, UDLD status and link failure tests. Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop.
Incorrect Answers
A:Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. This change targets the wrong mechanism for STP Loop Guard and unidirectional fiber safeguards.
B:Use only endpoint port security to replace all inter-switch loop detection. Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Instead inspect bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
C:Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Disable spanning tree so the formerly blocked alternate link always forwards.
Question 282
A fiber trunk stops receiving BPDUs on a blocked alternate path and could incorrectly transition to forwarding. What should the operator inspect to verify the result?
- One successful ping to an unrelated test host without a path or failover test.
- A hostname inventory without effective configuration or operational measurements.
- An old network diagram with no current route, policy, or redundancy state.
- BPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
Explanation
Correct Answer
D:The intended procedure is use appropriate Loop Guard or UDLD mechanisms on eligible nonedge inter-switch links. Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop.
Incorrect Answers
A:This observation alone cannot establish sTP Loop Guard and unidirectional fiber safeguards. Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop.
B:This observation alone cannot establish sTP Loop Guard and unidirectional fiber safeguards. The decisive evidence instead includes bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
C:This observation alone cannot establish sTP Loop Guard and unidirectional fiber safeguards. An old network diagram with no current route, policy, or redundancy state.
Question 283
A fiber trunk stops receiving BPDUs on a blocked alternate path and could incorrectly transition to forwarding. Which technical statement is MOST accurate for this situation?
- Encryption and segmentation are identical mechanisms and can replace each other.
- A longer IP prefix is always less specific than the default route.
- Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop.
- An operational up state alone proves every security and design objective is met.
Explanation
Correct Answer
C:This is why the appropriate action is use appropriate Loop Guard or UDLD mechanisms on eligible nonedge inter-switch links. Confirm it with bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
Incorrect Answers
A:Encryption and segmentation are identical mechanisms and can replace each other. This is an incorrect generalization for sTP Loop Guard and unidirectional fiber safeguards. The relevant rule is loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Verify using bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
B:A longer IP prefix is always less specific than the default route. This is an incorrect generalization for sTP Loop Guard and unidirectional fiber safeguards. The relevant rule is loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Verify using bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
D:An operational up state alone proves every security and design objective is met. This is an incorrect generalization for sTP Loop Guard and unidirectional fiber safeguards. The relevant rule is loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Verify using bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
Question 284
A fiber trunk stops receiving BPDUs on a blocked alternate path and could incorrectly transition to forwarding. Suppose the operator instead makes this incorrect change: Treat a one-way fiber fault as if STP BPDUs can never be affected. What weakness does the mistaken approach introduce?
- Collecting telemetry originally caused the missing route or service outage.
- A correct change-control review makes all WAN carriers fail simultaneously.
- The only issue is an inaccurate hostname while traffic paths are unaffected.
- Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links.
Explanation
Correct Answer
D:This explains why the proposed shortcut does not solve sTP Loop Guard and unidirectional fiber safeguards.
Incorrect Answers
A:Collecting telemetry originally caused the missing route or service outage. The actual failure is missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Check bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
B:A correct change-control review makes all WAN carriers fail simultaneously. The actual failure is missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Check bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
C:The only issue is an inaccurate hostname while traffic paths are unaffected. The actual failure is missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Check bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
Question 285
A fiber trunk stops receiving BPDUs on a blocked alternate path and could incorrectly transition to forwarding. The observed fault is: Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Which recovery is BEST once this fault is identified?
- Use only endpoint port security to replace all inter-switch loop detection.
- Disable spanning tree so the formerly blocked alternate link always forwards.
- Treat a one-way fiber fault as if STP BPDUs can never be affected.
- Apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.
Explanation
Correct Answer
D:Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. This corrects the described failure and provides a verifiable outcome.
Incorrect Answers
A:Use only endpoint port security to replace all inter-switch loop detection. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.
B:Disable spanning tree so the formerly blocked alternate link always forwards. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.
C:Treat a one-way fiber fault as if STP BPDUs can never be affected. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.
Question 286
A campus experiences a unidirectional optic failure and needs to prevent a Layer 2 loop when STP information disappears. Which operator action most directly resolves this condition?
- For this enterprise design, the architect should use appropriate Loop Guard or UDLD mechanisms on eligible nonedge inter-switch links.
- For this enterprise design, the architect should use only endpoint port security to replace all inter-switch loop detection.
- For this enterprise design, the architect should disable spanning tree so the formerly blocked alternate link always forwards.
- For this enterprise design, the architect should treat a one-way fiber fault as if STP BPDUs can never be affected.
Explanation
Correct Answer
A:Confirm the result using bPDU reception history, loop-inconsistent state, UDLD status and link failure tests. This is the specific corrective action for STP Loop Guard and unidirectional fiber safeguards.
Incorrect Answers
B:Use only endpoint port security to replace all inter-switch loop detection. Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Instead inspect bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
C:Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links.
D:Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. The relevant action is use appropriate Loop Guard or UDLD mechanisms on eligible nonedge inter-switch links.
Question 287
A campus experiences a unidirectional optic failure and needs to prevent a Layer 2 loop when STP information disappears. Which collection of observations most directly tests the suspected cause?
- Inspect the following evidence: bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
- Inspect the following evidence: a feature-license screenshot without the required design or acceptance tests.
- Inspect the following evidence: one successful ping to an unrelated test host without a path or failover test.
- Inspect the following evidence: a hostname inventory without effective configuration or operational measurements.
Explanation
Correct Answer
A:The intended procedure is use appropriate Loop Guard or UDLD mechanisms on eligible nonedge inter-switch links. This evidence observes the actual sTP Loop Guard and unidirectional fiber safeguards mechanism and its result.
Incorrect Answers
B:This observation alone cannot establish sTP Loop Guard and unidirectional fiber safeguards. A feature-license screenshot without the required design or acceptance tests.
C:This observation alone cannot establish sTP Loop Guard and unidirectional fiber safeguards. One successful ping to an unrelated test host without a path or failover test.
D:This observation alone cannot establish sTP Loop Guard and unidirectional fiber safeguards. A hostname inventory without effective configuration or operational measurements.
Question 288
A campus experiences a unidirectional optic failure and needs to prevent a Layer 2 loop when STP information disappears. Which system behavior underlies the appropriate response?
- The relevant principle is that loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop.
- The relevant principle is that an operational up state alone proves every security and design objective is met.
- The relevant principle is that encryption and segmentation are identical mechanisms and can replace each other.
- The relevant principle is that cloud connectivity automatically removes any requirement for routing or policy.
Explanation
Correct Answer
A:This is why the appropriate action is use appropriate Loop Guard or UDLD mechanisms on eligible nonedge inter-switch links.
Incorrect Answers
B:An operational up state alone proves every security and design objective is met. This is an incorrect generalization for sTP Loop Guard and unidirectional fiber safeguards. The relevant rule is loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Verify using bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
C:Encryption and segmentation are identical mechanisms and can replace each other. This is an incorrect generalization for sTP Loop Guard and unidirectional fiber safeguards. The relevant rule is loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Verify using bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
D:Cloud connectivity automatically removes any requirement for routing or policy. This is an incorrect generalization for sTP Loop Guard and unidirectional fiber safeguards. The relevant rule is loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Verify using bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
Question 289
A campus experiences a unidirectional optic failure and needs to prevent a Layer 2 loop when STP information disappears. Suppose the operator instead makes this incorrect change: Treat a one-way fiber fault as if STP BPDUs can never be affected. Which failure or risk follows from this shortcut?
- The resulting technical fault is that the only issue is an inaccurate hostname while traffic paths are unaffected.
- The resulting technical fault is that a healthy unrelated system proves the intended failure domain is protected.
- The resulting technical fault is that missing protection on a unidirectional failure may create a loop despite apparently functioning physical links.
- The resulting technical fault is that a correct change-control review makes all WAN carriers fail simultaneously.
Explanation
Correct Answer
C:The right response is use appropriate Loop Guard or UDLD mechanisms on eligible nonedge inter-switch links.
Incorrect Answers
A:The only issue is an inaccurate hostname while traffic paths are unaffected. The actual failure is missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Check bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
B:A healthy unrelated system proves the intended failure domain is protected. The actual failure is missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Check bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
D:A correct change-control review makes all WAN carriers fail simultaneously. The actual failure is missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Check bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
Question 290
A campus experiences a unidirectional optic failure and needs to prevent a Layer 2 loop when STP information disappears. The observed fault is: Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. What action most directly restores and validates the intended state?
- The controlled recovery is to disable spanning tree so the formerly blocked alternate link always forwards.
- The controlled recovery is to treat a one-way fiber fault as if STP BPDUs can never be affected.
- The controlled recovery is to use only endpoint port security to replace all inter-switch loop detection.
- The controlled recovery is to apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.
Explanation
Correct Answer
D:Loop Guard prevents non-designated STP ports from becoming designated simply because expected BPDUs stop. Relevant evidence includes bPDU reception history, loop-inconsistent state, UDLD status and link failure tests.
Incorrect Answers
A:Disable spanning tree so the formerly blocked alternate link always forwards. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.
B:Treat a one-way fiber fault as if STP BPDUs can never be affected. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.
C:Use only endpoint port security to replace all inter-switch loop detection. Missing protection on a unidirectional failure may create a loop despite apparently functioning physical links. Use the controlled remediation: apply correct per-port protection and validate blocked-link handling under simulated BPDU loss.