Nokia 4A0-C03 Practice Test 2
Question 10
Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Which measurable result would verify success without relying on assumptions?
- Both routers advertise distinct system IDs and all intended peer databases converge consistently.
- The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
- The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
- Level-1 routers choose an intended border exit and preserve local area reachability.
Explanation
Correct Answer
B:The acceptance measurement for this case is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information. It establishes that the intended remediation (“Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs”) was effective and can be corroborated by: Compare the decoded Level-1 Hello area-address information with the documented regional topology.
Incorrect Answers
A:The actual case evidence is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The proposed option addresses a different condition: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Confirm the distinction by checking: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The response supported by the evidence is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
C:This choice does not address the stated situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-supported response is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
D:The alternative applies to another situation: Two Level-1-only sites have different routes to a Level-1/Level-2 gateway, and a trainee calls the area-exit signal a normal user subnet prefix. The reported case instead states: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The distinguishing check is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The supported action or criterion is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
Question 11
A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Which change most directly addresses the observed problem?
- Reconcile the NET area plan and preserve a deliberate Level-2 backbone relationship across areas.
- Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
- Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
- Assign a stable unique system ID to each routing system and retain the approved area addressing structure.
Explanation
Correct Answer
B:The fault stated in this case is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The specific corrective action is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented. Confirm it with: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The expected end-to-end outcome is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
Incorrect Answers
A:The alternative is directed at this separate case: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
C:The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The distinguishing check is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The supported action or criterion is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
D:These other facts could justify the alternative: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. They differ from the stated case: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Test the distinction using: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-specific response is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
Question 12
A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Which TWO independent checks would best establish what is happening? (Select TWO.)
- Compare both routers' NET values and the system-ID portion of the configured network entity titles.
- Inspect both Level-1 and Level-2 adjacency counts before and after renumbering.
- Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts.
- Compare each router's level capability and database exchange with the approved cross-area design.
- Inspect PDU-size related drops and link MTU configuration for each peer.
Explanation
Correct Answers
C:This is a direct diagnostic for the reported fault: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. A second independent check is: Compare each router's level capability and database exchange with the approved cross-area design. Combined evidence distinguishes the fault before implementing: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
D:This is a direct diagnostic for the reported fault: Compare each router's level capability and database exchange with the approved cross-area design. A second independent check is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. Combined evidence distinguishes the fault before implementing: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
Incorrect Answers
A:This choice does not address the stated situation: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Its competing context is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The relevant diagnostic is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-supported response is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts; and Compare each router's level capability and database exchange with the approved cross-area design.
B:The alternative applies to another situation: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. The reported case instead states: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The distinguishing check is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The supported action or criterion is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts; and Compare each router's level capability and database exchange with the approved cross-area design.
E:The alternative is directed at this separate case: Two edge devices pass small traffic but larger IS-IS link-state PDUs are discarded after an MPLS-over-Ethernet migration changed effective link MTU. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts; and Compare each router's level capability and database exchange with the approved cross-area design.
Question 13
A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. What is the key technical or security failure this situation can produce?
- Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
- Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.
- A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.
- An uncoordinated area change can break local reachability while leaving backbone traffic partially operational.
Explanation
Correct Answer
A:The observed condition is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The principal operational or security impact is: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability. The supported repair is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
B:These other facts could justify the alternative: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. They differ from the stated case: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Test the distinction using: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-specific response is: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
C:The actual case evidence is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The proposed option addresses a different condition: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Confirm the distinction by checking: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The response supported by the evidence is: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
D:The alternative is directed at this separate case: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
Question 14
A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Choose TWO complementary steps: one repair and one precaution against collateral impact. (Select TWO.)
- Replace the blanket deny with a specific approved prefix filter that preserves required Level-2 reachability.
- Reconcile the NET area plan and preserve a deliberate Level-2 backbone relationship across areas.
- Align supported IS-IS PDU size and underlying port MTU on both sides of the affected link.
- Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
- Stage changes at both ends while protecting existing Level-1 routes and management access.
Explanation
Correct Answers
D:This is the required technical repair: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented. The separately necessary deployment safeguard is: Stage changes at both ends while protecting existing Level-1 routes and management access. Together they address: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
E:This safeguard prevents unwanted collateral effects: Stage changes at both ends while protecting existing Level-1 routes and management access. Its complementary corrective change is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented. Both are required because: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
Incorrect Answers
A:These other facts could justify the alternative: A provider core policy update filters every Level-2 prefix from one neighboring area to stop one unwanted aggregate, unexpectedly removing healthy routes. They differ from the stated case: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Test the distinction using: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-specific response is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented; and Stage changes at both ends while protecting existing Level-1 routes and management access.
B:The actual case evidence is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The proposed option addresses a different condition: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. Confirm the distinction by checking: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The response supported by the evidence is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented; and Stage changes at both ends while protecting existing Level-1 routes and management access.
C:The alternative is directed at this separate case: Two edge devices pass small traffic but larger IS-IS link-state PDUs are discarded after an MPLS-over-Ethernet migration changed effective link MTU. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented; and Stage changes at both ends while protecting existing Level-1 routes and management access.
Question 15
A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. What evidence would demonstrate that the intended fix worked correctly?
- Both routers advertise distinct system IDs and all intended peer databases converge consistently.
- The intended new area peers form Level-1 relationships and Level-2 backbone transit remains stable.
- The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
- The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
Explanation
Correct Answer
D:The acceptance measurement for this case is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone. It establishes that the intended remediation (“Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented”) was effective and can be corroborated by: Compare each router's level capability and database exchange with the approved cross-area design.
Incorrect Answers
A:The actual case evidence is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The proposed option addresses a different condition: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Confirm the distinction by checking: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The response supported by the evidence is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
B:The alternative is directed at this separate case: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
C:This choice does not address the stated situation: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Its competing context is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The relevant diagnostic is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-supported response is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
Question 16
An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Which corrective action best resolves this particular network fault?
- Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
- Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
- Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
- Diagnose the point-to-point adjacency handshake and correct mismatched peer state before resetting the entire area.
Explanation
Correct Answer
C:The fault stated in this case is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The specific corrective action is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan. Confirm it with: Compare level capability advertisements and current adjacency state on both point-to-point ends. The expected end-to-end outcome is: The two routers negotiate the intended common level and install the expected routes.
Incorrect Answers
A:The alternative is directed at this separate case: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The present incident is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The pertinent verification is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The action or outcome to select here is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
B:This choice does not address the stated situation: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-supported response is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
D:These other facts could justify the alternative: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. They differ from the stated case: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Test the distinction using: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-specific response is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
Question 17
An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Before proposing a change, which TWO observations would give the most useful confirmation? (Select TWO.)
- Compare level capability advertisements and current adjacency state on both point-to-point ends.
- Inspect transmitted and received point-to-point Hello TLVs and their neighbor state indications.
- Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts.
- Inspect rejected Level-2 advertisements and policy match statistics for several sample prefixes.
- Inspect router-wide IS-IS level support and interface overrides before making any edit.
Explanation
Correct Answers
A:This is a direct diagnostic for the reported fault: Compare level capability advertisements and current adjacency state on both point-to-point ends. A second independent check is: Inspect router-wide IS-IS level support and interface overrides before making any edit. Combined evidence distinguishes the fault before implementing: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
E:This is a direct diagnostic for the reported fault: Inspect router-wide IS-IS level support and interface overrides before making any edit. A second independent check is: Compare level capability advertisements and current adjacency state on both point-to-point ends. Combined evidence distinguishes the fault before implementing: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
Incorrect Answers
B:The alternative applies to another situation: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. The reported case instead states: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The distinguishing check is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The supported action or criterion is: Compare level capability advertisements and current adjacency state on both point-to-point ends; and Inspect router-wide IS-IS level support and interface overrides before making any edit.
C:These other facts could justify the alternative: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. They differ from the stated case: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Test the distinction using: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-specific response is: Compare level capability advertisements and current adjacency state on both point-to-point ends; and Inspect router-wide IS-IS level support and interface overrides before making any edit.
D:The actual case evidence is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The proposed option addresses a different condition: A provider core policy update filters every Level-2 prefix from one neighboring area to stop one unwanted aggregate, unexpectedly removing healthy routes. Confirm the distinction by checking: Compare level capability advertisements and current adjacency state on both point-to-point ends. The response supported by the evidence is: Compare level capability advertisements and current adjacency state on both point-to-point ends; and Inspect router-wide IS-IS level support and interface overrides before making any edit.
Question 18
An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Which statement best describes the immediate risk of ignoring this problem?
- Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
- A broken neighbor handshake can prevent safe two-way topology advertisement despite bidirectional packet reception.
- A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.
- A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.
Explanation
Correct Answer
D:The observed condition is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The principal operational or security impact is: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit. The supported repair is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan. Risk describes a possible effect, not proof of every downstream failure.
Incorrect Answers
A:The alternative applies to another situation: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The reported case instead states: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The distinguishing check is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The supported action or criterion is: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.
B:These other facts could justify the alternative: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. They differ from the stated case: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Test the distinction using: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-specific response is: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.
C:The actual case evidence is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The proposed option addresses a different condition: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Confirm the distinction by checking: Compare level capability advertisements and current adjacency state on both point-to-point ends. The response supported by the evidence is: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.
Question 19
An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Which TWO measures together address the fault while protecting other services? (Select TWO.)
- Replace the blanket deny with a specific approved prefix filter that preserves required Level-2 reachability.
- Configure a compatible wide-metric IS-IS strategy across the intended area before applying large link costs.
- Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
- Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
- Coordinate both-side changes and maintain an out-of-band access path for rollback.
Explanation
Correct Answers
C:This is the required technical repair: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan. The separately necessary deployment safeguard is: Coordinate both-side changes and maintain an out-of-band access path for rollback. Together they address: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.
E:This safeguard prevents unwanted collateral effects: Coordinate both-side changes and maintain an out-of-band access path for rollback. Its complementary corrective change is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan. Both are required because: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.
Incorrect Answers
A:These other facts could justify the alternative: A provider core policy update filters every Level-2 prefix from one neighboring area to stop one unwanted aggregate, unexpectedly removing healthy routes. They differ from the stated case: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Test the distinction using: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-specific response is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan; and Coordinate both-side changes and maintain an out-of-band access path for rollback.
B:The actual case evidence is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The proposed option addresses a different condition: A routing design assigns a link cost above the legacy narrow-metric range, but a peer only understands narrow cost advertisements. Confirm the distinction by checking: Compare level capability advertisements and current adjacency state on both point-to-point ends. The response supported by the evidence is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan; and Coordinate both-side changes and maintain an out-of-band access path for rollback.
D:This choice does not address the stated situation: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-supported response is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan; and Coordinate both-side changes and maintain an out-of-band access path for rollback.
Question 20
An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. After the approved repair, which outcome best demonstrates that this exact fault is resolved?
- The peer state becomes Up on both sides and link-state advertisements converge without flapping.
- The two routers negotiate the intended common level and install the expected routes.
- The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
- The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
Explanation
Correct Answer
B:The acceptance measurement for this case is: The two routers negotiate the intended common level and install the expected routes. It establishes that the intended remediation (“Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan”) was effective and can be corroborated by: Inspect router-wide IS-IS level support and interface overrides before making any edit.
Incorrect Answers
A:The actual case evidence is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The proposed option addresses a different condition: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. Confirm the distinction by checking: Compare level capability advertisements and current adjacency state on both point-to-point ends. The response supported by the evidence is: The two routers negotiate the intended common level and install the expected routes.
C:This choice does not address the stated situation: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-supported response is: The two routers negotiate the intended common level and install the expected routes.
D:The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The distinguishing check is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The supported action or criterion is: The two routers negotiate the intended common level and install the expected routes.