cert
cert-1
cert-2

Pass Nokia 4A0-C03 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
4A0-C03 Exam - Verified By Experts
4A0-C03 Premium File

4A0-C03 Premium File

$69.99
$76.99
  • Premium File 145 Questions & Answers. Last Update: Nov 23, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Nokia 4A0-C03 Practice Test 2

Question 10

Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Which measurable result would verify success without relying on assumptions?

  1. Both routers advertise distinct system IDs and all intended peer databases converge consistently.
  2. The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
  3. The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
  4. Level-1 routers choose an intended border exit and preserve local area reachability.

Explanation

Correct Answer

B:

The acceptance measurement for this case is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information. It establishes that the intended remediation (“Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs”) was effective and can be corroborated by: Compare the decoded Level-1 Hello area-address information with the documented regional topology.

Incorrect Answers

A:

The actual case evidence is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The proposed option addresses a different condition: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Confirm the distinction by checking: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The response supported by the evidence is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

C:

This choice does not address the stated situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-supported response is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

D:

The alternative applies to another situation: Two Level-1-only sites have different routes to a Level-1/Level-2 gateway, and a trainee calls the area-exit signal a normal user subnet prefix. The reported case instead states: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The distinguishing check is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The supported action or criterion is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

Question 11

A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Which change most directly addresses the observed problem?

  1. Reconcile the NET area plan and preserve a deliberate Level-2 backbone relationship across areas.
  2. Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
  3. Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
  4. Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

Explanation

Correct Answer

B:

The fault stated in this case is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The specific corrective action is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented. Confirm it with: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The expected end-to-end outcome is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.

Incorrect Answers

A:

The alternative is directed at this separate case: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.

C:

The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The distinguishing check is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The supported action or criterion is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.

D:

These other facts could justify the alternative: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. They differ from the stated case: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Test the distinction using: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-specific response is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.

Question 12

A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Which TWO independent checks would best establish what is happening? (Select TWO.)

  1. Compare both routers' NET values and the system-ID portion of the configured network entity titles.
  2. Inspect both Level-1 and Level-2 adjacency counts before and after renumbering.
  3. Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts.
  4. Compare each router's level capability and database exchange with the approved cross-area design.
  5. Inspect PDU-size related drops and link MTU configuration for each peer.

Explanation

Correct Answers

C:

This is a direct diagnostic for the reported fault: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. A second independent check is: Compare each router's level capability and database exchange with the approved cross-area design. Combined evidence distinguishes the fault before implementing: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.

D:

This is a direct diagnostic for the reported fault: Compare each router's level capability and database exchange with the approved cross-area design. A second independent check is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. Combined evidence distinguishes the fault before implementing: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.

Incorrect Answers

A:

This choice does not address the stated situation: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Its competing context is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The relevant diagnostic is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-supported response is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts; and Compare each router's level capability and database exchange with the approved cross-area design.

B:

The alternative applies to another situation: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. The reported case instead states: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The distinguishing check is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The supported action or criterion is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts; and Compare each router's level capability and database exchange with the approved cross-area design.

E:

The alternative is directed at this separate case: Two edge devices pass small traffic but larger IS-IS link-state PDUs are discarded after an MPLS-over-Ethernet migration changed effective link MTU. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts; and Compare each router's level capability and database exchange with the approved cross-area design.

Question 13

A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. What is the key technical or security failure this situation can produce?

  1. Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
  2. Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.
  3. A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.
  4. An uncoordinated area change can break local reachability while leaving backbone traffic partially operational.

Explanation

Correct Answer

A:

The observed condition is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The principal operational or security impact is: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability. The supported repair is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

B:

These other facts could justify the alternative: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. They differ from the stated case: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Test the distinction using: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-specific response is: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.

C:

The actual case evidence is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The proposed option addresses a different condition: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Confirm the distinction by checking: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The response supported by the evidence is: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.

D:

The alternative is directed at this separate case: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.

Question 14

A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Choose TWO complementary steps: one repair and one precaution against collateral impact. (Select TWO.)

  1. Replace the blanket deny with a specific approved prefix filter that preserves required Level-2 reachability.
  2. Reconcile the NET area plan and preserve a deliberate Level-2 backbone relationship across areas.
  3. Align supported IS-IS PDU size and underlying port MTU on both sides of the affected link.
  4. Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
  5. Stage changes at both ends while protecting existing Level-1 routes and management access.

Explanation

Correct Answers

D:

This is the required technical repair: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented. The separately necessary deployment safeguard is: Stage changes at both ends while protecting existing Level-1 routes and management access. Together they address: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.

E:

This safeguard prevents unwanted collateral effects: Stage changes at both ends while protecting existing Level-1 routes and management access. Its complementary corrective change is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented. Both are required because: Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.

Incorrect Answers

A:

These other facts could justify the alternative: A provider core policy update filters every Level-2 prefix from one neighboring area to stop one unwanted aggregate, unexpectedly removing healthy routes. They differ from the stated case: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Test the distinction using: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-specific response is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented; and Stage changes at both ends while protecting existing Level-1 routes and management access.

B:

The actual case evidence is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The proposed option addresses a different condition: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. Confirm the distinction by checking: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The response supported by the evidence is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented; and Stage changes at both ends while protecting existing Level-1 routes and management access.

C:

The alternative is directed at this separate case: Two edge devices pass small traffic but larger IS-IS link-state PDUs are discarded after an MPLS-over-Ethernet migration changed effective link MTU. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented; and Stage changes at both ends while protecting existing Level-1 routes and management access.

Question 15

A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. What evidence would demonstrate that the intended fix worked correctly?

  1. Both routers advertise distinct system IDs and all intended peer databases converge consistently.
  2. The intended new area peers form Level-1 relationships and Level-2 backbone transit remains stable.
  3. The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
  4. The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.

Explanation

Correct Answer

D:

The acceptance measurement for this case is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone. It establishes that the intended remediation (“Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented”) was effective and can be corroborated by: Compare each router's level capability and database exchange with the approved cross-area design.

Incorrect Answers

A:

The actual case evidence is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The proposed option addresses a different condition: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Confirm the distinction by checking: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The response supported by the evidence is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.

B:

The alternative is directed at this separate case: One router changes its ISO area identifier during site renumbering and its former Level-1 neighbors no longer share area membership, but Level-2 connectivity remains. The present incident is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The pertinent verification is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The action or outcome to select here is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.

C:

This choice does not address the stated situation: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Its competing context is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The relevant diagnostic is: Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts. The case-supported response is: The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.

Question 16

An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Which corrective action best resolves this particular network fault?

  1. Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
  2. Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
  3. Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
  4. Diagnose the point-to-point adjacency handshake and correct mismatched peer state before resetting the entire area.

Explanation

Correct Answer

C:

The fault stated in this case is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The specific corrective action is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan. Confirm it with: Compare level capability advertisements and current adjacency state on both point-to-point ends. The expected end-to-end outcome is: The two routers negotiate the intended common level and install the expected routes.

Incorrect Answers

A:

The alternative is directed at this separate case: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The present incident is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The pertinent verification is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The action or outcome to select here is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.

B:

This choice does not address the stated situation: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-supported response is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.

D:

These other facts could justify the alternative: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. They differ from the stated case: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Test the distinction using: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-specific response is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.

Question 17

An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Before proposing a change, which TWO observations would give the most useful confirmation? (Select TWO.)

  1. Compare level capability advertisements and current adjacency state on both point-to-point ends.
  2. Inspect transmitted and received point-to-point Hello TLVs and their neighbor state indications.
  3. Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts.
  4. Inspect rejected Level-2 advertisements and policy match statistics for several sample prefixes.
  5. Inspect router-wide IS-IS level support and interface overrides before making any edit.

Explanation

Correct Answers

A:

This is a direct diagnostic for the reported fault: Compare level capability advertisements and current adjacency state on both point-to-point ends. A second independent check is: Inspect router-wide IS-IS level support and interface overrides before making any edit. Combined evidence distinguishes the fault before implementing: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.

E:

This is a direct diagnostic for the reported fault: Inspect router-wide IS-IS level support and interface overrides before making any edit. A second independent check is: Compare level capability advertisements and current adjacency state on both point-to-point ends. Combined evidence distinguishes the fault before implementing: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.

Incorrect Answers

B:

The alternative applies to another situation: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. The reported case instead states: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The distinguishing check is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The supported action or criterion is: Compare level capability advertisements and current adjacency state on both point-to-point ends; and Inspect router-wide IS-IS level support and interface overrides before making any edit.

C:

These other facts could justify the alternative: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. They differ from the stated case: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Test the distinction using: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-specific response is: Compare level capability advertisements and current adjacency state on both point-to-point ends; and Inspect router-wide IS-IS level support and interface overrides before making any edit.

D:

The actual case evidence is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The proposed option addresses a different condition: A provider core policy update filters every Level-2 prefix from one neighboring area to stop one unwanted aggregate, unexpectedly removing healthy routes. Confirm the distinction by checking: Compare level capability advertisements and current adjacency state on both point-to-point ends. The response supported by the evidence is: Compare level capability advertisements and current adjacency state on both point-to-point ends; and Inspect router-wide IS-IS level support and interface overrides before making any edit.

Question 18

An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Which statement best describes the immediate risk of ignoring this problem?

  1. Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
  2. A broken neighbor handshake can prevent safe two-way topology advertisement despite bidirectional packet reception.
  3. A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.
  4. A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.

Explanation

Correct Answer

D:

The observed condition is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The principal operational or security impact is: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit. The supported repair is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The reported case instead states: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The distinguishing check is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The supported action or criterion is: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.

B:

These other facts could justify the alternative: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. They differ from the stated case: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Test the distinction using: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-specific response is: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.

C:

The actual case evidence is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The proposed option addresses a different condition: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Confirm the distinction by checking: Compare level capability advertisements and current adjacency state on both point-to-point ends. The response supported by the evidence is: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.

Question 19

An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Which TWO measures together address the fault while protecting other services? (Select TWO.)

  1. Replace the blanket deny with a specific approved prefix filter that preserves required Level-2 reachability.
  2. Configure a compatible wide-metric IS-IS strategy across the intended area before applying large link costs.
  3. Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
  4. Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
  5. Coordinate both-side changes and maintain an out-of-band access path for rollback.

Explanation

Correct Answers

C:

This is the required technical repair: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan. The separately necessary deployment safeguard is: Coordinate both-side changes and maintain an out-of-band access path for rollback. Together they address: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.

E:

This safeguard prevents unwanted collateral effects: Coordinate both-side changes and maintain an out-of-band access path for rollback. Its complementary corrective change is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan. Both are required because: A lack of any common supported IS-IS level prevents link-state synchronization on a healthy circuit.

Incorrect Answers

A:

These other facts could justify the alternative: A provider core policy update filters every Level-2 prefix from one neighboring area to stop one unwanted aggregate, unexpectedly removing healthy routes. They differ from the stated case: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Test the distinction using: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-specific response is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan; and Coordinate both-side changes and maintain an out-of-band access path for rollback.

B:

The actual case evidence is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The proposed option addresses a different condition: A routing design assigns a link cost above the legacy narrow-metric range, but a peer only understands narrow cost advertisements. Confirm the distinction by checking: Compare level capability advertisements and current adjacency state on both point-to-point ends. The response supported by the evidence is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan; and Coordinate both-side changes and maintain an out-of-band access path for rollback.

D:

This choice does not address the stated situation: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-supported response is: Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan; and Coordinate both-side changes and maintain an out-of-band access path for rollback.

Question 20

An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. After the approved repair, which outcome best demonstrates that this exact fault is resolved?

  1. The peer state becomes Up on both sides and link-state advertisements converge without flapping.
  2. The two routers negotiate the intended common level and install the expected routes.
  3. The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
  4. The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

Explanation

Correct Answer

B:

The acceptance measurement for this case is: The two routers negotiate the intended common level and install the expected routes. It establishes that the intended remediation (“Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan”) was effective and can be corroborated by: Inspect router-wide IS-IS level support and interface overrides before making any edit.

Incorrect Answers

A:

The actual case evidence is: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The proposed option addresses a different condition: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. Confirm the distinction by checking: Compare level capability advertisements and current adjacency state on both point-to-point ends. The response supported by the evidence is: The two routers negotiate the intended common level and install the expected routes.

C:

This choice does not address the stated situation: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The case-supported response is: The two routers negotiate the intended common level and install the expected routes.

D:

The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. The distinguishing check is: Compare level capability advertisements and current adjacency state on both point-to-point ends. The supported action or criterion is: The two routers negotiate the intended common level and install the expected routes.

Nokia NRS II Composite: IS-IS version (4A0-C03) Practice Tests