cert
cert-1
cert-2

Pass Nokia 4A0-C03 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
4A0-C03 Exam - Verified By Experts
4A0-C03 Premium File

4A0-C03 Premium File

$69.99
$76.99
  • Premium File 145 Questions & Answers. Last Update: Nov 23, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 10 downloads in the last 7 days
block-screenshots
Nokia 4A0-C03 Practice Test 1

Question 1

Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. An operator needs a controlled repair. Which response is most appropriate?

  1. Assign a stable unique system ID to each routing system and retain the approved area addressing structure.
  2. Repair the unstable link and use supported SPF/LSP pacing only after documenting actual topology churn.
  3. Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
  4. Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.

Explanation

Correct Answer

A:

The fault stated in this case is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The specific corrective action is: Assign a stable unique system ID to each routing system and retain the approved area addressing structure. Confirm it with: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The expected end-to-end outcome is: Both routers advertise distinct system IDs and all intended peer databases converge consistently.

Incorrect Answers

B:

This choice does not address the stated situation: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Its competing context is: A regional core repeatedly recomputes shortest paths because one unstable interface generates frequent changing LSPs. The relevant diagnostic is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The case-supported response is: Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

C:

The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The distinguishing check is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The supported action or criterion is: Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

D:

These other facts could justify the alternative: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. They differ from the stated case: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Test the distinction using: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The case-specific response is: Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

Question 2

Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Which TWO diagnostic investigations most directly test the cause? (Select TWO.)

  1. Correlate LSP generation counters with physical link transition timestamps.
  2. Compare both routers' NET values and the system-ID portion of the configured network entity titles.
  3. Inspect the link-state database for conflicting originators and sequence changes attributed to the duplicated identity.
  4. Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts.
  5. Compare the LSP identifier, sequence number and checksum held by the two peers.

Explanation

Correct Answers

B:

This is a direct diagnostic for the reported fault: Compare both routers' NET values and the system-ID portion of the configured network entity titles. A second independent check is: Inspect the link-state database for conflicting originators and sequence changes attributed to the duplicated identity. Combined evidence distinguishes the fault before implementing: Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

C:

This is a direct diagnostic for the reported fault: Inspect the link-state database for conflicting originators and sequence changes attributed to the duplicated identity. A second independent check is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. Combined evidence distinguishes the fault before implementing: Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

Incorrect Answers

A:

This choice does not address the stated situation: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Its competing context is: A regional core repeatedly recomputes shortest paths because one unstable interface generates frequent changing LSPs. The relevant diagnostic is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The case-supported response is: Compare both routers' NET values and the system-ID portion of the configured network entity titles; and Inspect the link-state database for conflicting originators and sequence changes attributed to the duplicated identity.

D:

The actual case evidence is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The proposed option addresses a different condition: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Confirm the distinction by checking: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The response supported by the evidence is: Compare both routers' NET values and the system-ID portion of the configured network entity titles; and Inspect the link-state database for conflicting originators and sequence changes attributed to the duplicated identity.

E:

The alternative is directed at this separate case: Two connected routing nodes retain different versions of the same IS-IS originator's LSP after a fiber repair, producing inconsistent SPF results. The present incident is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The pertinent verification is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The action or outcome to select here is: Compare both routers' NET values and the system-ID portion of the configured network entity titles; and Inspect the link-state database for conflicting originators and sequence changes attributed to the duplicated identity.

Question 3

Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Which specific consequence explains why a repair is necessary?

  1. A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.
  2. Continuous topology churn can increase CPU consumption and extend reconvergence for unrelated paths.
  3. Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.
  4. Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.

Explanation

Correct Answer

C:

The observed condition is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The principal operational or security impact is: Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation. The supported repair is: Assign a stable unique system ID to each routing system and retain the approved area addressing structure. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The reported case instead states: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The distinguishing check is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The supported action or criterion is: Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.

B:

These other facts could justify the alternative: A regional core repeatedly recomputes shortest paths because one unstable interface generates frequent changing LSPs. They differ from the stated case: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Test the distinction using: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The case-specific response is: Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.

D:

The alternative is directed at this separate case: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The present incident is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The pertinent verification is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The action or outcome to select here is: Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.

Question 4

Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Which TWO actions form both a suitable correction and its necessary change-control safeguard? (Select TWO.)

  1. Restore reliable LSP synchronization using sequence-number comparisons and protocol flooding state inspection.
  2. Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
  3. Correct one lab device at a time with a complete adjacency and rollback plan before deployment.
  4. Assign a stable unique system ID to each routing system and retain the approved area addressing structure.
  5. Align supported IS-IS PDU size and underlying port MTU on both sides of the affected link.

Explanation

Correct Answers

C:

This safeguard prevents unwanted collateral effects: Correct one lab device at a time with a complete adjacency and rollback plan before deployment. Its complementary corrective change is: Assign a stable unique system ID to each routing system and retain the approved area addressing structure. Both are required because: Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.

D:

This is the required technical repair: Assign a stable unique system ID to each routing system and retain the approved area addressing structure. The separately necessary deployment safeguard is: Correct one lab device at a time with a complete adjacency and rollback plan before deployment. Together they address: Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.

Incorrect Answers

A:

These other facts could justify the alternative: Two connected routing nodes retain different versions of the same IS-IS originator's LSP after a fiber repair, producing inconsistent SPF results. They differ from the stated case: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Test the distinction using: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The case-specific response is: Correct one lab device at a time with a complete adjacency and rollback plan before deployment; and Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

B:

The actual case evidence is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The proposed option addresses a different condition: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. Confirm the distinction by checking: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The response supported by the evidence is: Correct one lab device at a time with a complete adjacency and rollback plan before deployment; and Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

E:

The alternative applies to another situation: Two edge devices pass small traffic but larger IS-IS link-state PDUs are discarded after an MPLS-over-Ethernet migration changed effective link MTU. The reported case instead states: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The distinguishing check is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The supported action or criterion is: Correct one lab device at a time with a complete adjacency and rollback plan before deployment; and Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

Question 5

Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Which post-change observation is the strongest acceptance criterion?

  1. Both routers advertise distinct system IDs and all intended peer databases converge consistently.
  2. The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
  3. The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
  4. Link-state updates settle and SPF executions return to an expected stable cadence.

Explanation

Correct Answer

A:

The acceptance measurement for this case is: Both routers advertise distinct system IDs and all intended peer databases converge consistently. It establishes that the intended remediation (“Assign a stable unique system ID to each routing system and retain the approved area addressing structure”) was effective and can be corroborated by: Inspect the link-state database for conflicting originators and sequence changes attributed to the duplicated identity.

Incorrect Answers

B:

The alternative is directed at this separate case: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The present incident is: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The pertinent verification is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The action or outcome to select here is: Both routers advertise distinct system IDs and all intended peer databases converge consistently.

C:

This choice does not address the stated situation: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Its competing context is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The relevant diagnostic is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The case-supported response is: Both routers advertise distinct system IDs and all intended peer databases converge consistently.

D:

The alternative applies to another situation: A regional core repeatedly recomputes shortest paths because one unstable interface generates frequent changing LSPs. The reported case instead states: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. The distinguishing check is: Compare both routers' NET values and the system-ID portion of the configured network entity titles. The supported action or criterion is: Both routers advertise distinct system IDs and all intended peer databases converge consistently.

Question 6

Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Which next technical step should the engineer prioritize?

  1. Identify the Level-1 attached-bit exit behavior rather than manually inventing a complete set of remote prefixes.
  2. Enable the intended Level-2 adjacency for the inter-area backbone while keeping Level-1 boundaries documented.
  3. Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
  4. Assign a stable unique system ID to each routing system and retain the approved area addressing structure.

Explanation

Correct Answer

C:

The fault stated in this case is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The specific corrective action is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs. Confirm it with: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The expected end-to-end outcome is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

Incorrect Answers

A:

The alternative is directed at this separate case: Two Level-1-only sites have different routes to a Level-1/Level-2 gateway, and a trainee calls the area-exit signal a normal user subnet prefix. The present incident is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The pertinent verification is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The action or outcome to select here is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.

B:

This choice does not address the stated situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-supported response is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.

D:

These other facts could justify the alternative: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. They differ from the stated case: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Test the distinction using: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-specific response is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.

Question 7

Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Which TWO items of evidence should the engineer examine first? (Select TWO.)

  1. Inspect IS-IS interface circuit type and currently active Level-1 versus Level-2 adjacency counts.
  2. Compare the decoded Level-1 Hello area-address information with the documented regional topology.
  3. Inspect transmitted and received point-to-point Hello TLVs and their neighbor state indications.
  4. Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange.
  5. Inspect attached-bit advertisement from reachable Level-1/Level-2 border routers.

Explanation

Correct Answers

B:

This is a direct diagnostic for the reported fault: Compare the decoded Level-1 Hello area-address information with the documented regional topology. A second independent check is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. Combined evidence distinguishes the fault before implementing: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.

D:

This is a direct diagnostic for the reported fault: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. A second independent check is: Compare the decoded Level-1 Hello area-address information with the documented regional topology. Combined evidence distinguishes the fault before implementing: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.

Incorrect Answers

A:

This choice does not address the stated situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-supported response is: Compare the decoded Level-1 Hello area-address information with the documented regional topology; and Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange.

C:

These other facts could justify the alternative: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. They differ from the stated case: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Test the distinction using: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-specific response is: Compare the decoded Level-1 Hello area-address information with the documented regional topology; and Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange.

E:

The alternative is directed at this separate case: Two Level-1-only sites have different routes to a Level-1/Level-2 gateway, and a trainee calls the area-exit signal a normal user subnet prefix. The present incident is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The pertinent verification is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The action or outcome to select here is: Compare the decoded Level-1 Hello area-address information with the documented regional topology; and Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange.

Question 8

Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. If the condition is left unresolved, which operational consequence is most directly at risk?

  1. Without suitable Level-2 connectivity, separate Level-1 areas cannot exchange intended inter-area reachability.
  2. Duplicated system IDs can make independent routers appear to be one originator and destabilize route computation.
  3. A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.
  4. Incorrect interpretations of the attached bit can create unnecessary static defaults or black-hole exits.

Explanation

Correct Answer

C:

The observed condition is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The principal operational or security impact is: A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes. The supported repair is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs. Risk describes a possible effect, not proof of every downstream failure.

Incorrect Answers

A:

The alternative applies to another situation: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The reported case instead states: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The distinguishing check is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The supported action or criterion is: A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.

B:

These other facts could justify the alternative: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. They differ from the stated case: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Test the distinction using: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-specific response is: A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.

D:

The alternative is directed at this separate case: Two Level-1-only sites have different routes to a Level-1/Level-2 gateway, and a trainee calls the area-exit signal a normal user subnet prefix. The present incident is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The pertinent verification is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The action or outcome to select here is: A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.

Question 9

Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The engineer wants a safe remedy. Which TWO actions should be paired? (Select TWO.)

  1. Identify the Level-1 attached-bit exit behavior rather than manually inventing a complete set of remote prefixes.
  2. Configure a compatible IS-IS circuit level on the correct peer interface in accordance with the network plan.
  3. Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs.
  4. Diagnose the point-to-point adjacency handshake and correct mismatched peer state before resetting the entire area.
  5. Validate the target area from the approved design before changing NET information on a live node.

Explanation

Correct Answers

C:

This is the required technical repair: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs. The separately necessary deployment safeguard is: Validate the target area from the approved design before changing NET information on a live node. Together they address: A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.

E:

This safeguard prevents unwanted collateral effects: Validate the target area from the approved design before changing NET information on a live node. Its complementary corrective change is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs. Both are required because: A mismatched area prevents Level-1 neighbor formation despite physical connectivity and valid IP routes.

Incorrect Answers

A:

These other facts could justify the alternative: Two Level-1-only sites have different routes to a Level-1/Level-2 gateway, and a trainee calls the area-exit signal a normal user subnet prefix. They differ from the stated case: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Test the distinction using: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-specific response is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs; and Validate the target area from the approved design before changing NET information on a live node.

B:

The actual case evidence is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The proposed option addresses a different condition: An SR OS router is configured as Level-1-only while the neighboring point-to-point peer permits only Level-2, leaving the IGP interface up with no common adjacency. Confirm the distinction by checking: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The response supported by the evidence is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs; and Validate the target area from the approved design before changing NET information on a live node.

D:

This choice does not address the stated situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Its competing context is: An interface shows repeated partial point-to-point IS-IS adjacency attempts after a peer restart, but the expected three-way confirmation never finishes. The relevant diagnostic is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-supported response is: Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs; and Validate the target area from the approved design before changing NET information on a live node.

Question 10

Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Which measurable result would verify success without relying on assumptions?

  1. Both routers advertise distinct system IDs and all intended peer databases converge consistently.
  2. The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.
  3. The Level-2 connection forms and authorized remote-area prefixes become reachable through the backbone.
  4. Level-1 routers choose an intended border exit and preserve local area reachability.

Explanation

Correct Answer

B:

The acceptance measurement for this case is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information. It establishes that the intended remediation (“Align the intended Level-1 area membership on the shared link rather than changing unrelated interface costs”) was effective and can be corroborated by: Compare the decoded Level-1 Hello area-address information with the documented regional topology.

Incorrect Answers

A:

The actual case evidence is: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The proposed option addresses a different condition: Two new Nokia edge routers use the same six-byte system ID in their NET configuration, causing inconsistent link-state origin records in a regional lab. Confirm the distinction by checking: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The response supported by the evidence is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

C:

This choice does not address the stated situation: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. Its competing context is: A service core spans two different Level-1 areas, yet two aggregation routers were configured to exchange only Level-1 IS-IS information across their inter-area link. The relevant diagnostic is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The case-supported response is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

D:

The alternative applies to another situation: Two Level-1-only sites have different routes to a Level-1/Level-2 gateway, and a trainee calls the area-exit signal a normal user subnet prefix. The reported case instead states: Two Nokia routers on the same Ethernet circuit have matching link settings but never establish a Level-1 IS-IS adjacency because their NET area values differ. The distinguishing check is: Inspect each neighbor's configured NET area prefix and Level-1 adjacency counters during Hello exchange. The supported action or criterion is: The authorized Level-1 neighbors reach Up state and exchange their expected area link-state information.

Nokia NRS II Composite: IS-IS version (4A0-C03) Practice Tests