cert
cert-1
cert-2

Pass Network Appliance NS0-094 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
NS0-094 Exam - Verified By Experts
NS0-094 Premium File

NS0-094 Premium File

$89.99
$98.99
  • Premium File 60 Questions & Answers. Last Update: Nov 19, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$98.99
$89.99
accept 10 downloads in the last 7 days
block-screenshots
Network Appliance NS0-094 Practice Test 71

Question 700

Fictional NetApp hardware-support incident R376-C175: A replacement HBA carries a new WWPN but switches retain the old zoning. What measurable acceptance condition should the reviewer require after corrective work?

  1. Supported initiator logs in and sees the intended presented LUN
  2. Protocol connectivity is restored by a scoped network or service fix
  3. Cluster communication stays healthy independent of client data services
  4. Appropriate host paths are visible through approved FC zones

Explanation

Correct Answer

D:

Appropriate host paths are visible through approved FC zones. This outcome would specifically test whether host cannot see lun because san fabric zoning omits its initiator has been corrected in the fictional situation: A replacement HBA carries a new WWPN but switches retain the old zoning.. It should follow the supported response confirm initiator/target wwpn zoning and port states for supported fc host access, with evidence from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.

Incorrect Answers

A:

Supported initiator logs in and sees the intended presented LUN could be a positive validation for the adjacent topic ISCSI target discovery and session, but is insufficient to close this fault. The case reports A replacement HBA carries a new WWPN but switches retain the old zoning.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

B:

Protocol connectivity is restored by a scoped network or service fix could be a positive validation for the adjacent topic Protocol port scope and firewall, but is insufficient to close this fault. The case reports A replacement HBA carries a new WWPN but switches retain the old zoning.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

C:

Cluster communication stays healthy independent of client data services could be a positive validation for the adjacent topic Cluster network isolation, but is insufficient to close this fault. The case reports A replacement HBA carries a new WWPN but switches retain the old zoning.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

Question 701

Fictional NetApp hardware-support incident R376-C176: A new fabric targets a node port not assigned to the intended SVM FC LIF. Which plan most directly resolves the identified hardware-support risk?

  1. Confirm initiator/target WWPN zoning and port states for supported FC host access
  2. Verify export rules, client match and access protocols before assigning a NAS client outage to hardware
  3. Distinguish service listener, route and network filters when NFS, SMB or SAN clients time out
  4. Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health

Explanation

Correct Answer

A:

Confirm initiator/target WWPN zoning and port states for supported FC host access. This is the targeted supported response because host cannot see lun because san fabric zoning omits its initiator. The fictional incident is: A new fabric targets a node port not assigned to the intended SVM FC LIF.. The technician should first correlate compare host wwpn and target wwpn zones with inspect fabric and ontap fc target lif online state, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that appropriate host paths are visible through approved fc zones. The chosen step is author-intended and still needs an independent NetApp-platform expert check.

Incorrect Answers

B:

Verify export rules, client match and access protocols before assigning a NAS client outage to hardware is a legitimate focus when investigating NFS export policy specificity, but it does not resolve the reported fibre channel zoning correctness failure. In this particular incident, A new fabric targets a node port not assigned to the intended SVM FC LIF.. The decisive checks are compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state; these isolate why host cannot see lun because san fabric zoning omits its initiator. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm initiator/target wwpn zoning and port states for supported fc host access. Expert review has not yet confirmed option exclusivity.

C:

Distinguish service listener, route and network filters when NFS, SMB or SAN clients time out is a legitimate focus when investigating Protocol port scope and firewall, but it does not resolve the reported fibre channel zoning correctness failure. In this particular incident, A new fabric targets a node port not assigned to the intended SVM FC LIF.. The decisive checks are compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state; these isolate why host cannot see lun because san fabric zoning omits its initiator. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm initiator/target wwpn zoning and port states for supported fc host access. Expert review has not yet confirmed option exclusivity.

D:

Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health is a legitimate focus when investigating SMB share and authentication, but it does not resolve the reported fibre channel zoning correctness failure. In this particular incident, A new fabric targets a node port not assigned to the intended SVM FC LIF.. The decisive checks are compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state; these isolate why host cannot see lun because san fabric zoning omits its initiator. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm initiator/target wwpn zoning and port states for supported fc host access. Expert review has not yet confirmed option exclusivity.

Question 702

Fictional NetApp hardware-support incident R376-C176: A new fabric targets a node port not assigned to the intended SVM FC LIF. Which check should be requested first to test the reported condition?

  1. Inspect matching export policy rules
  2. Compare host WWPN and target WWPN zones
  3. Check ONTAP LUN map and igroup membership
  4. Check cluster port and LIF status

Explanation

Correct Answer

B:

Compare host WWPN and target WWPN zones is directly relevant evidence for the fibre channel zoning correctness scenario. Pair it with inspect fabric and ontap fc target lif online state when both are called for to establish whether host cannot see lun because san fabric zoning omits its initiator. The support case reports A new fabric targets a node port not assigned to the intended SVM FC LIF.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that appropriate host paths are visible through approved fc zones. This is an author-intended diagnostic choice requiring human technical confirmation.

Incorrect Answers

A:

Inspect matching export policy rules may be appropriate for a separate nfs export policy specificity case, but is not the most discriminating check in this incident: A new fabric targets a node port not assigned to the intended SVM FC LIF.. The described failure is host cannot see lun because san fabric zoning omits its initiator. The targeted evidence is compare host wwpn and target wwpn zones together with inspect fabric and ontap fc target lif online state, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

C:

Check ONTAP LUN map and igroup membership may be appropriate for a separate lun mapping and igroup case, but is not the most discriminating check in this incident: A new fabric targets a node port not assigned to the intended SVM FC LIF.. The described failure is host cannot see lun because san fabric zoning omits its initiator. The targeted evidence is compare host wwpn and target wwpn zones together with inspect fabric and ontap fc target lif online state, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

D:

Check cluster port and LIF status may be appropriate for a separate cluster network isolation case, but is not the most discriminating check in this incident: A new fabric targets a node port not assigned to the intended SVM FC LIF.. The described failure is host cannot see lun because san fabric zoning omits its initiator. The targeted evidence is compare host wwpn and target wwpn zones together with inspect fabric and ontap fc target lif online state, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

Question 703

Fictional NetApp hardware-support incident R376-C176: A new fabric targets a node port not assigned to the intended SVM FC LIF. What is the principal engineering fault indicated by the scenario?

  1. An authentication or ACL rejection is treated as a failed disk
  2. A LUN is healthy in storage but invisible due to missing host mapping
  3. Host cannot see LUN because SAN fabric zoning omits its initiator
  4. Host cannot discover LUN because its target is unreachable

Explanation

Correct Answer

C:

Host cannot see LUN because SAN fabric zoning omits its initiator. This diagnosis fits the original incident, A new fabric targets a node port not assigned to the intended SVM FC LIF., rather than requiring an unrelated service action. Check compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state to confirm the location and status of the affected resource. The relevant corrective response is confirm initiator/target wwpn zoning and port states for supported fc host access, with final acceptance when appropriate host paths are visible through approved fc zones. The author-intended diagnosis has not yet received independent support engineering validation.

Incorrect Answers

A:

An authentication or ACL rejection is treated as a failed disk describes a possible failure in the neighboring topic SMB share and authentication, not the main mechanism demonstrated here. The actual scenario is A new fabric targets a node port not assigned to the intended SVM FC LIF.; the more direct diagnosis is host cannot see lun because san fabric zoning omits its initiator. Confirm it from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.

B:

A LUN is healthy in storage but invisible due to missing host mapping describes a possible failure in the neighboring topic LUN mapping and igroup, not the main mechanism demonstrated here. The actual scenario is A new fabric targets a node port not assigned to the intended SVM FC LIF.; the more direct diagnosis is host cannot see lun because san fabric zoning omits its initiator. Confirm it from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.

D:

Host cannot discover LUN because its target is unreachable describes a possible failure in the neighboring topic ISCSI target discovery and session, not the main mechanism demonstrated here. The actual scenario is A new fabric targets a node port not assigned to the intended SVM FC LIF.; the more direct diagnosis is host cannot see lun because san fabric zoning omits its initiator. Confirm it from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.

Question 704

Fictional NetApp hardware-support incident R376-C176: A new fabric targets a node port not assigned to the intended SVM FC LIF. Which post-service observation best demonstrates the specific problem is resolved?

  1. Protocol connectivity is restored by a scoped network or service fix
  2. The authorized identity reaches the correct SMB share
  3. Required client subnet is reachable on the correct VLAN
  4. Appropriate host paths are visible through approved FC zones

Explanation

Correct Answer

D:

Appropriate host paths are visible through approved FC zones. This outcome would specifically test whether host cannot see lun because san fabric zoning omits its initiator has been corrected in the fictional situation: A new fabric targets a node port not assigned to the intended SVM FC LIF.. It should follow the supported response confirm initiator/target wwpn zoning and port states for supported fc host access, with evidence from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.

Incorrect Answers

A:

Protocol connectivity is restored by a scoped network or service fix could be a positive validation for the adjacent topic Protocol port scope and firewall, but is insufficient to close this fault. The case reports A new fabric targets a node port not assigned to the intended SVM FC LIF.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

B:

The authorized identity reaches the correct SMB share could be a positive validation for the adjacent topic SMB share and authentication, but is insufficient to close this fault. The case reports A new fabric targets a node port not assigned to the intended SVM FC LIF.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

C:

Required client subnet is reachable on the correct VLAN could be a positive validation for the adjacent topic VLAN tags and switch port mode, but is insufficient to close this fault. The case reports A new fabric targets a node port not assigned to the intended SVM FC LIF.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

Question 705

Fictional NetApp hardware-support incident R376-C177: A provisioned iSCSI LUN is not presented to the server's igroup. Which approved diagnostic or corrective step should be selected first?

  1. Verify SAN LUN mapping to correct igroup initiators and host visibility
  2. Verify export rules, client match and access protocols before assigning a NAS client outage to hardware
  3. Preserve dedicated cluster interconnect health and port roles during switch or adapter changes
  4. Confirm initiator/target WWPN zoning and port states for supported FC host access

Explanation

Correct Answer

A:

Verify SAN LUN mapping to correct igroup initiators and host visibility. This is the targeted supported response because a lun is healthy in storage but invisible due to missing host mapping. The fictional incident is: A provisioned iSCSI LUN is not presented to the server's igroup.. The technician should first correlate check ontap lun map and igroup membership with confirm host multipath sees expected lun id and wwid, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that only intended host initiators can access the mapped lun. The chosen step is author-intended and still needs an independent NetApp-platform expert check.

Incorrect Answers

B:

Verify export rules, client match and access protocols before assigning a NAS client outage to hardware is a legitimate focus when investigating NFS export policy specificity, but it does not resolve the reported lun mapping and igroup failure. In this particular incident, A provisioned iSCSI LUN is not presented to the server's igroup.. The decisive checks are check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid; these isolate why a lun is healthy in storage but invisible due to missing host mapping. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify san lun mapping to correct igroup initiators and host visibility. Expert review has not yet confirmed option exclusivity.

C:

Preserve dedicated cluster interconnect health and port roles during switch or adapter changes is a legitimate focus when investigating Cluster network isolation, but it does not resolve the reported lun mapping and igroup failure. In this particular incident, A provisioned iSCSI LUN is not presented to the server's igroup.. The decisive checks are check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid; these isolate why a lun is healthy in storage but invisible due to missing host mapping. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify san lun mapping to correct igroup initiators and host visibility. Expert review has not yet confirmed option exclusivity.

D:

Confirm initiator/target WWPN zoning and port states for supported FC host access is a legitimate focus when investigating Fibre Channel zoning correctness, but it does not resolve the reported lun mapping and igroup failure. In this particular incident, A provisioned iSCSI LUN is not presented to the server's igroup.. The decisive checks are check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid; these isolate why a lun is healthy in storage but invisible due to missing host mapping. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify san lun mapping to correct igroup initiators and host visibility. Expert review has not yet confirmed option exclusivity.

Question 706

Fictional NetApp hardware-support incident R376-C177: A provisioned iSCSI LUN is not presented to the server's igroup. What record best distinguishes this suspected issue from a nearby hardware fault?

  1. Compare host WWPN and target WWPN zones
  2. Check ONTAP LUN map and igroup membership
  3. Check actual target listener and server service
  4. Check network path to target portals

Explanation

Correct Answer

B:

Check ONTAP LUN map and igroup membership is directly relevant evidence for the lun mapping and igroup scenario. Pair it with confirm host multipath sees expected lun id and wwid when both are called for to establish whether a lun is healthy in storage but invisible due to missing host mapping. The support case reports A provisioned iSCSI LUN is not presented to the server's igroup.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that only intended host initiators can access the mapped lun. This is an author-intended diagnostic choice requiring human technical confirmation.

Incorrect Answers

A:

Compare host WWPN and target WWPN zones may be appropriate for a separate fibre channel zoning correctness case, but is not the most discriminating check in this incident: A provisioned iSCSI LUN is not presented to the server's igroup.. The described failure is a lun is healthy in storage but invisible due to missing host mapping. The targeted evidence is check ontap lun map and igroup membership together with confirm host multipath sees expected lun id and wwid, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

C:

Check actual target listener and server service may be appropriate for a separate protocol port scope and firewall case, but is not the most discriminating check in this incident: A provisioned iSCSI LUN is not presented to the server's igroup.. The described failure is a lun is healthy in storage but invisible due to missing host mapping. The targeted evidence is check ontap lun map and igroup membership together with confirm host multipath sees expected lun id and wwid, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

D:

Check network path to target portals may be appropriate for a separate iscsi target discovery and session case, but is not the most discriminating check in this incident: A provisioned iSCSI LUN is not presented to the server's igroup.. The described failure is a lun is healthy in storage but invisible due to missing host mapping. The targeted evidence is check ontap lun map and igroup membership together with confirm host multipath sees expected lun id and wwid, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

Question 707

Fictional NetApp hardware-support incident R376-C177: A provisioned iSCSI LUN is not presented to the server's igroup. What is the principal engineering fault indicated by the scenario?

  1. Host cannot discover LUN because its target is unreachable
  2. Network ACL or protocol service is down but technician orders replacement media
  3. A LUN is healthy in storage but invisible due to missing host mapping
  4. Host cannot see LUN because SAN fabric zoning omits its initiator

Explanation

Correct Answer

C:

A LUN is healthy in storage but invisible due to missing host mapping. This diagnosis fits the original incident, A provisioned iSCSI LUN is not presented to the server's igroup., rather than requiring an unrelated service action. Check check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid to confirm the location and status of the affected resource. The relevant corrective response is verify san lun mapping to correct igroup initiators and host visibility, with final acceptance when only intended host initiators can access the mapped lun. The author-intended diagnosis has not yet received independent support engineering validation.

Incorrect Answers

A:

Host cannot discover LUN because its target is unreachable describes a possible failure in the neighboring topic ISCSI target discovery and session, not the main mechanism demonstrated here. The actual scenario is A provisioned iSCSI LUN is not presented to the server's igroup.; the more direct diagnosis is a lun is healthy in storage but invisible due to missing host mapping. Confirm it from check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.

B:

Network ACL or protocol service is down but technician orders replacement media describes a possible failure in the neighboring topic Protocol port scope and firewall, not the main mechanism demonstrated here. The actual scenario is A provisioned iSCSI LUN is not presented to the server's igroup.; the more direct diagnosis is a lun is healthy in storage but invisible due to missing host mapping. Confirm it from check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.

D:

Host cannot see LUN because SAN fabric zoning omits its initiator describes a possible failure in the neighboring topic Fibre Channel zoning correctness, not the main mechanism demonstrated here. The actual scenario is A provisioned iSCSI LUN is not presented to the server's igroup.; the more direct diagnosis is a lun is healthy in storage but invisible due to missing host mapping. Confirm it from check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.

Question 708

Fictional NetApp hardware-support incident R376-C177: A provisioned iSCSI LUN is not presented to the server's igroup. Which post-service observation best demonstrates the specific problem is resolved?

  1. The authorized identity reaches the correct SMB share
  2. Protocol connectivity is restored by a scoped network or service fix
  3. Authorized NFS mount succeeds under intended rules
  4. Only intended host initiators can access the mapped LUN

Explanation

Correct Answer

D:

Only intended host initiators can access the mapped LUN. This outcome would specifically test whether a lun is healthy in storage but invisible due to missing host mapping has been corrected in the fictional situation: A provisioned iSCSI LUN is not presented to the server's igroup.. It should follow the supported response verify san lun mapping to correct igroup initiators and host visibility, with evidence from check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.

Incorrect Answers

A:

The authorized identity reaches the correct SMB share could be a positive validation for the adjacent topic SMB share and authentication, but is insufficient to close this fault. The case reports A provisioned iSCSI LUN is not presented to the server's igroup.. Its direct acceptance condition is that only intended host initiators can access the mapped lun, after the appropriate action verify san lun mapping to correct igroup initiators and host visibility. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

B:

Protocol connectivity is restored by a scoped network or service fix could be a positive validation for the adjacent topic Protocol port scope and firewall, but is insufficient to close this fault. The case reports A provisioned iSCSI LUN is not presented to the server's igroup.. Its direct acceptance condition is that only intended host initiators can access the mapped lun, after the appropriate action verify san lun mapping to correct igroup initiators and host visibility. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

C:

Authorized NFS mount succeeds under intended rules could be a positive validation for the adjacent topic NFS export policy specificity, but is insufficient to close this fault. The case reports A provisioned iSCSI LUN is not presented to the server's igroup.. Its direct acceptance condition is that only intended host initiators can access the mapped lun, after the appropriate action verify san lun mapping to correct igroup initiators and host visibility. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.

Question 709

Fictional NetApp hardware-support incident R376-C178: A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused. Which response best fits the evidence without disturbing an unrelated healthy component?

  1. Verify SAN LUN mapping to correct igroup initiators and host visibility
  2. Trace initiator to SVM data LIF, target portal and established iSCSI session before blaming media
  3. Verify network MTU across host, switch and ONTAP ports for large frames
  4. Confirm initiator/target WWPN zoning and port states for supported FC host access

Explanation

Correct Answer

A:

Verify SAN LUN mapping to correct igroup initiators and host visibility. This is the targeted supported response because a lun is healthy in storage but invisible due to missing host mapping. The fictional incident is: A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused.. The technician should first correlate check ontap lun map and igroup membership with confirm host multipath sees expected lun id and wwid, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that only intended host initiators can access the mapped lun. The chosen step is author-intended and still needs an independent NetApp-platform expert check.

Incorrect Answers

B:

Trace initiator to SVM data LIF, target portal and established iSCSI session before blaming media is a legitimate focus when investigating ISCSI target discovery and session, but it does not resolve the reported lun mapping and igroup failure. In this particular incident, A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused.. The decisive checks are check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid; these isolate why a lun is healthy in storage but invisible due to missing host mapping. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify san lun mapping to correct igroup initiators and host visibility. Expert review has not yet confirmed option exclusivity.

C:

Verify network MTU across host, switch and ONTAP ports for large frames is a legitimate focus when investigating MTU continuity end to end, but it does not resolve the reported lun mapping and igroup failure. In this particular incident, A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused.. The decisive checks are check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid; these isolate why a lun is healthy in storage but invisible due to missing host mapping. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify san lun mapping to correct igroup initiators and host visibility. Expert review has not yet confirmed option exclusivity.

D:

Confirm initiator/target WWPN zoning and port states for supported FC host access is a legitimate focus when investigating Fibre Channel zoning correctness, but it does not resolve the reported lun mapping and igroup failure. In this particular incident, A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused.. The decisive checks are check ontap lun map and igroup membership and confirm host multipath sees expected lun id and wwid; these isolate why a lun is healthy in storage but invisible due to missing host mapping. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is verify san lun mapping to correct igroup initiators and host visibility. Expert review has not yet confirmed option exclusivity.

Question 710

Fictional NetApp hardware-support incident R376-C178: A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused. Which check should be requested first to test the reported condition?

  1. Check actual target listener and server service
  2. Check ONTAP LUN map and igroup membership
  3. Compare host WWPN and target WWPN zones
  4. Inspect ONTAP VLAN object and parent port

Explanation

Correct Answer

B:

Check ONTAP LUN map and igroup membership is directly relevant evidence for the lun mapping and igroup scenario. Pair it with confirm host multipath sees expected lun id and wwid when both are called for to establish whether a lun is healthy in storage but invisible due to missing host mapping. The support case reports A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that only intended host initiators can access the mapped lun. This is an author-intended diagnostic choice requiring human technical confirmation.

Incorrect Answers

A:

Check actual target listener and server service may be appropriate for a separate protocol port scope and firewall case, but is not the most discriminating check in this incident: A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused.. The described failure is a lun is healthy in storage but invisible due to missing host mapping. The targeted evidence is check ontap lun map and igroup membership together with confirm host multipath sees expected lun id and wwid, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

C:

Compare host WWPN and target WWPN zones may be appropriate for a separate fibre channel zoning correctness case, but is not the most discriminating check in this incident: A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused.. The described failure is a lun is healthy in storage but invisible due to missing host mapping. The targeted evidence is check ontap lun map and igroup membership together with confirm host multipath sees expected lun id and wwid, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

D:

Inspect ONTAP VLAN object and parent port may be appropriate for a separate vlan tags and switch port mode case, but is not the most discriminating check in this incident: A newly deployed host sees another team's LUN because igroup initiators were incorrectly reused.. The described failure is a lun is healthy in storage but invisible due to missing host mapping. The targeted evidence is check ontap lun map and igroup membership together with confirm host multipath sees expected lun id and wwid, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.

NetApp Hardware Support Engineer Professional (NS0-094) Practice Tests