Network Appliance NS0-094 Practice Test 73
Question 720
Fictional NetApp hardware-support incident R376-C180: A new cluster switch uses a default low MTU and intermittent large storage frames fail. Which post-service observation best demonstrates the specific problem is resolved?
- Protocol connectivity is restored by a scoped network or service fix
- Only intended host initiators can access the mapped LUN
- The authorized identity reaches the correct SMB share
- Storage transport works reliably at a mutually supported MTU
Explanation
Correct Answer
D:Storage transport works reliably at a mutually supported MTU. This outcome would specifically test whether one device drops jumbo frames despite others advertising high mtu has been corrected in the fictional situation: A new cluster switch uses a default low MTU and intermittent large storage frames fail.. It should follow the supported response verify network mtu across host, switch and ontap ports for large frames, with evidence from test path mtu along the storage route and compare switch and host mtu configuration with lif/port settings. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Protocol connectivity is restored by a scoped network or service fix could be a positive validation for the adjacent topic Protocol port scope and firewall, but is insufficient to close this fault. The case reports A new cluster switch uses a default low MTU and intermittent large storage frames fail.. Its direct acceptance condition is that storage transport works reliably at a mutually supported mtu, after the appropriate action verify network mtu across host, switch and ontap ports for large frames. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Only intended host initiators can access the mapped LUN could be a positive validation for the adjacent topic LUN mapping and igroup, but is insufficient to close this fault. The case reports A new cluster switch uses a default low MTU and intermittent large storage frames fail.. Its direct acceptance condition is that storage transport works reliably at a mutually supported mtu, after the appropriate action verify network mtu across host, switch and ontap ports for large frames. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:The authorized identity reaches the correct SMB share could be a positive validation for the adjacent topic SMB share and authentication, but is insufficient to close this fault. The case reports A new cluster switch uses a default low MTU and intermittent large storage frames fail.. Its direct acceptance condition is that storage transport works reliably at a mutually supported mtu, after the appropriate action verify network mtu across host, switch and ontap ports for large frames. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 721
Fictional NetApp hardware-support incident R376-C181: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120. Which supported next step addresses the diagnosed fault while preserving the healthy parts of the system?
- Confirm host and ONTAP VLAN IDs and switch trunk/access settings before treating lost link as hardware failure
- Preserve dedicated cluster interconnect health and port roles during switch or adapter changes
- Verify network MTU across host, switch and ONTAP ports for large frames
- Distinguish service listener, route and network filters when NFS, SMB or SAN clients time out
Explanation
Correct Answer
A:Confirm host and ONTAP VLAN IDs and switch trunk/access settings before treating lost link as hardware failure. This is the targeted supported response because lif uses a vlan not carried through the upstream switch. The fictional incident is: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. The technician should first correlate inspect ontap vlan object and parent port with verify switch allowed vlan and tagged traffic path, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that required client subnet is reachable on the correct vlan. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
B:Preserve dedicated cluster interconnect health and port roles during switch or adapter changes is a legitimate focus when investigating Cluster network isolation, but it does not resolve the reported vlan tags and switch port mode failure. In this particular incident, A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. The decisive checks are inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path; these isolate why lif uses a vlan not carried through the upstream switch. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Expert review has not yet confirmed option exclusivity.
C:Verify network MTU across host, switch and ONTAP ports for large frames is a legitimate focus when investigating MTU continuity end to end, but it does not resolve the reported vlan tags and switch port mode failure. In this particular incident, A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. The decisive checks are inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path; these isolate why lif uses a vlan not carried through the upstream switch. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Expert review has not yet confirmed option exclusivity.
D:Distinguish service listener, route and network filters when NFS, SMB or SAN clients time out is a legitimate focus when investigating Protocol port scope and firewall, but it does not resolve the reported vlan tags and switch port mode failure. In this particular incident, A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. The decisive checks are inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path; these isolate why lif uses a vlan not carried through the upstream switch. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Expert review has not yet confirmed option exclusivity.
Question 722
Fictional NetApp hardware-support incident R376-C181: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120. Which check should be requested first to test the reported condition?
- Test path MTU along the storage route
- Inspect ONTAP VLAN object and parent port
- Check share and file ACLs
- Check ONTAP LUN map and igroup membership
Explanation
Correct Answer
B:Inspect ONTAP VLAN object and parent port is directly relevant evidence for the vlan tags and switch port mode scenario. Pair it with verify switch allowed vlan and tagged traffic path when both are called for to establish whether lif uses a vlan not carried through the upstream switch. The support case reports A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that required client subnet is reachable on the correct vlan. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Test path MTU along the storage route may be appropriate for a separate mtu continuity end to end case, but is not the most discriminating check in this incident: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. The described failure is lif uses a vlan not carried through the upstream switch. The targeted evidence is inspect ontap vlan object and parent port together with verify switch allowed vlan and tagged traffic path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Check share and file ACLs may be appropriate for a separate smb share and authentication case, but is not the most discriminating check in this incident: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. The described failure is lif uses a vlan not carried through the upstream switch. The targeted evidence is inspect ontap vlan object and parent port together with verify switch allowed vlan and tagged traffic path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Check ONTAP LUN map and igroup membership may be appropriate for a separate lun mapping and igroup case, but is not the most discriminating check in this incident: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. The described failure is lif uses a vlan not carried through the upstream switch. The targeted evidence is inspect ontap vlan object and parent port together with verify switch allowed vlan and tagged traffic path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 723
Fictional NetApp hardware-support incident R376-C181: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120. What assumption should the engineer reject before touching equipment?
- Cluster traffic is connected through the client data path or wrong VLAN
- A LUN is healthy in storage but invisible due to missing host mapping
- LIF uses a VLAN not carried through the upstream switch
- An authentication or ACL rejection is treated as a failed disk
Explanation
Correct Answer
C:LIF uses a VLAN not carried through the upstream switch. This diagnosis fits the original incident, A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120., rather than requiring an unrelated service action. Check inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path to confirm the location and status of the affected resource. The relevant corrective response is confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure, with final acceptance when required client subnet is reachable on the correct vlan. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
A:Cluster traffic is connected through the client data path or wrong VLAN describes a possible failure in the neighboring topic Cluster network isolation, not the main mechanism demonstrated here. The actual scenario is A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.; the more direct diagnosis is lif uses a vlan not carried through the upstream switch. Confirm it from inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
B:A LUN is healthy in storage but invisible due to missing host mapping describes a possible failure in the neighboring topic LUN mapping and igroup, not the main mechanism demonstrated here. The actual scenario is A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.; the more direct diagnosis is lif uses a vlan not carried through the upstream switch. Confirm it from inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
D:An authentication or ACL rejection is treated as a failed disk describes a possible failure in the neighboring topic SMB share and authentication, not the main mechanism demonstrated here. The actual scenario is A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.; the more direct diagnosis is lif uses a vlan not carried through the upstream switch. Confirm it from inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 724
Fictional NetApp hardware-support incident R376-C181: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120. Which test result best shows restoration of the intended protected behavior?
- Protocol connectivity is restored by a scoped network or service fix
- Supported initiator logs in and sees the intended presented LUN
- Cluster communication stays healthy independent of client data services
- Required client subnet is reachable on the correct VLAN
Explanation
Correct Answer
D:Required client subnet is reachable on the correct VLAN. This outcome would specifically test whether lif uses a vlan not carried through the upstream switch has been corrected in the fictional situation: A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. It should follow the supported response confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure, with evidence from inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Protocol connectivity is restored by a scoped network or service fix could be a positive validation for the adjacent topic Protocol port scope and firewall, but is insufficient to close this fault. The case reports A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. Its direct acceptance condition is that required client subnet is reachable on the correct vlan, after the appropriate action confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Supported initiator logs in and sees the intended presented LUN could be a positive validation for the adjacent topic ISCSI target discovery and session, but is insufficient to close this fault. The case reports A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. Its direct acceptance condition is that required client subnet is reachable on the correct vlan, after the appropriate action confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Cluster communication stays healthy independent of client data services could be a positive validation for the adjacent topic Cluster network isolation, but is insufficient to close this fault. The case reports A new data LIF sits on VLAN 210 while the switch trunk allows only VLAN 120.. Its direct acceptance condition is that required client subnet is reachable on the correct vlan, after the appropriate action confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 725
Fictional NetApp hardware-support incident R376-C182: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability. Which supported next step addresses the diagnosed fault while preserving the healthy parts of the system?
- Confirm host and ONTAP VLAN IDs and switch trunk/access settings before treating lost link as hardware failure
- Verify network MTU across host, switch and ONTAP ports for large frames
- Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health
- Verify SAN LUN mapping to correct igroup initiators and host visibility
Explanation
Correct Answer
A:Confirm host and ONTAP VLAN IDs and switch trunk/access settings before treating lost link as hardware failure. This is the targeted supported response because lif uses a vlan not carried through the upstream switch. The fictional incident is: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. The technician should first correlate inspect ontap vlan object and parent port with verify switch allowed vlan and tagged traffic path, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that required client subnet is reachable on the correct vlan. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
B:Verify network MTU across host, switch and ONTAP ports for large frames is a legitimate focus when investigating MTU continuity end to end, but it does not resolve the reported vlan tags and switch port mode failure. In this particular incident, A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. The decisive checks are inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path; these isolate why lif uses a vlan not carried through the upstream switch. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Expert review has not yet confirmed option exclusivity.
C:Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health is a legitimate focus when investigating SMB share and authentication, but it does not resolve the reported vlan tags and switch port mode failure. In this particular incident, A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. The decisive checks are inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path; these isolate why lif uses a vlan not carried through the upstream switch. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Expert review has not yet confirmed option exclusivity.
D:Verify SAN LUN mapping to correct igroup initiators and host visibility is a legitimate focus when investigating LUN mapping and igroup, but it does not resolve the reported vlan tags and switch port mode failure. In this particular incident, A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. The decisive checks are inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path; these isolate why lif uses a vlan not carried through the upstream switch. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Expert review has not yet confirmed option exclusivity.
Question 726
Fictional NetApp hardware-support incident R376-C182: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability. Which check should be requested first to test the reported condition?
- Check share and file ACLs
- Inspect ONTAP VLAN object and parent port
- Test path MTU along the storage route
- Compare host WWPN and target WWPN zones
Explanation
Correct Answer
B:Inspect ONTAP VLAN object and parent port is directly relevant evidence for the vlan tags and switch port mode scenario. Pair it with verify switch allowed vlan and tagged traffic path when both are called for to establish whether lif uses a vlan not carried through the upstream switch. The support case reports A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that required client subnet is reachable on the correct vlan. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Check share and file ACLs may be appropriate for a separate smb share and authentication case, but is not the most discriminating check in this incident: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. The described failure is lif uses a vlan not carried through the upstream switch. The targeted evidence is inspect ontap vlan object and parent port together with verify switch allowed vlan and tagged traffic path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Test path MTU along the storage route may be appropriate for a separate mtu continuity end to end case, but is not the most discriminating check in this incident: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. The described failure is lif uses a vlan not carried through the upstream switch. The targeted evidence is inspect ontap vlan object and parent port together with verify switch allowed vlan and tagged traffic path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Compare host WWPN and target WWPN zones may be appropriate for a separate fibre channel zoning correctness case, but is not the most discriminating check in this incident: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. The described failure is lif uses a vlan not carried through the upstream switch. The targeted evidence is inspect ontap vlan object and parent port together with verify switch allowed vlan and tagged traffic path, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 727
Fictional NetApp hardware-support incident R376-C182: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability. What is the principal engineering fault indicated by the scenario?
- An authentication or ACL rejection is treated as a failed disk
- Host cannot discover LUN because its target is unreachable
- LIF uses a VLAN not carried through the upstream switch
- Host cannot see LUN because SAN fabric zoning omits its initiator
Explanation
Correct Answer
C:LIF uses a VLAN not carried through the upstream switch. This diagnosis fits the original incident, A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability., rather than requiring an unrelated service action. Check inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path to confirm the location and status of the affected resource. The relevant corrective response is confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure, with final acceptance when required client subnet is reachable on the correct vlan. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
A:An authentication or ACL rejection is treated as a failed disk describes a possible failure in the neighboring topic SMB share and authentication, not the main mechanism demonstrated here. The actual scenario is A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.; the more direct diagnosis is lif uses a vlan not carried through the upstream switch. Confirm it from inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
B:Host cannot discover LUN because its target is unreachable describes a possible failure in the neighboring topic ISCSI target discovery and session, not the main mechanism demonstrated here. The actual scenario is A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.; the more direct diagnosis is lif uses a vlan not carried through the upstream switch. Confirm it from inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
D:Host cannot see LUN because SAN fabric zoning omits its initiator describes a possible failure in the neighboring topic Fibre Channel zoning correctness, not the main mechanism demonstrated here. The actual scenario is A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.; the more direct diagnosis is lif uses a vlan not carried through the upstream switch. Confirm it from inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 728
Fictional NetApp hardware-support incident R376-C182: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability. Which post-service observation best demonstrates the specific problem is resolved?
- Protocol connectivity is restored by a scoped network or service fix
- Storage transport works reliably at a mutually supported MTU
- Cluster communication stays healthy independent of client data services
- Required client subnet is reachable on the correct VLAN
Explanation
Correct Answer
D:Required client subnet is reachable on the correct VLAN. This outcome would specifically test whether lif uses a vlan not carried through the upstream switch has been corrected in the fictional situation: A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. It should follow the supported response confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure, with evidence from inspect ontap vlan object and parent port and verify switch allowed vlan and tagged traffic path. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Protocol connectivity is restored by a scoped network or service fix could be a positive validation for the adjacent topic Protocol port scope and firewall, but is insufficient to close this fault. The case reports A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. Its direct acceptance condition is that required client subnet is reachable on the correct vlan, after the appropriate action confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Storage transport works reliably at a mutually supported MTU could be a positive validation for the adjacent topic MTU continuity end to end, but is insufficient to close this fault. The case reports A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. Its direct acceptance condition is that required client subnet is reachable on the correct vlan, after the appropriate action confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Cluster communication stays healthy independent of client data services could be a positive validation for the adjacent topic Cluster network isolation, but is insufficient to close this fault. The case reports A switch replacement changes a tagged ONTAP port to access mode and clients lose reachability.. Its direct acceptance condition is that required client subnet is reachable on the correct vlan, after the appropriate action confirm host and ontap vlan ids and switch trunk/access settings before treating lost link as hardware failure. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 729
Fictional NetApp hardware-support incident R376-C183: NFS mounts fail only across one firewall while local clients can mount normally. Which plan most directly resolves the identified hardware-support risk?
- Distinguish service listener, route and network filters when NFS, SMB or SAN clients time out
- Verify export rules, client match and access protocols before assigning a NAS client outage to hardware
- Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health
- Trace initiator to SVM data LIF, target portal and established iSCSI session before blaming media
Explanation
Correct Answer
A:Distinguish service listener, route and network filters when NFS, SMB or SAN clients time out. This is the targeted supported response because network acl or protocol service is down but technician orders replacement media. The fictional incident is: NFS mounts fail only across one firewall while local clients can mount normally.. The technician should first correlate check actual target listener and server service with test client path and applicable network acls, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that protocol connectivity is restored by a scoped network or service fix. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
B:Verify export rules, client match and access protocols before assigning a NAS client outage to hardware is a legitimate focus when investigating NFS export policy specificity, but it does not resolve the reported protocol port scope and firewall failure. In this particular incident, NFS mounts fail only across one firewall while local clients can mount normally.. The decisive checks are check actual target listener and server service and test client path and applicable network acls; these isolate why network acl or protocol service is down but technician orders replacement media. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is distinguish service listener, route and network filters when nfs, smb or san clients time out. Expert review has not yet confirmed option exclusivity.
C:Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health is a legitimate focus when investigating SMB share and authentication, but it does not resolve the reported protocol port scope and firewall failure. In this particular incident, NFS mounts fail only across one firewall while local clients can mount normally.. The decisive checks are check actual target listener and server service and test client path and applicable network acls; these isolate why network acl or protocol service is down but technician orders replacement media. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is distinguish service listener, route and network filters when nfs, smb or san clients time out. Expert review has not yet confirmed option exclusivity.
D:Trace initiator to SVM data LIF, target portal and established iSCSI session before blaming media is a legitimate focus when investigating ISCSI target discovery and session, but it does not resolve the reported protocol port scope and firewall failure. In this particular incident, NFS mounts fail only across one firewall while local clients can mount normally.. The decisive checks are check actual target listener and server service and test client path and applicable network acls; these isolate why network acl or protocol service is down but technician orders replacement media. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is distinguish service listener, route and network filters when nfs, smb or san clients time out. Expert review has not yet confirmed option exclusivity.
Question 730
Fictional NetApp hardware-support incident R376-C183: NFS mounts fail only across one firewall while local clients can mount normally. Which verification would directly support or reject the proposed diagnosis?
- Check cluster port and LIF status
- Check actual target listener and server service
- Inspect ONTAP VLAN object and parent port
- Test path MTU along the storage route
Explanation
Correct Answer
B:Check actual target listener and server service is directly relevant evidence for the protocol port scope and firewall scenario. Pair it with test client path and applicable network acls when both are called for to establish whether network acl or protocol service is down but technician orders replacement media. The support case reports NFS mounts fail only across one firewall while local clients can mount normally.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that protocol connectivity is restored by a scoped network or service fix. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Check cluster port and LIF status may be appropriate for a separate cluster network isolation case, but is not the most discriminating check in this incident: NFS mounts fail only across one firewall while local clients can mount normally.. The described failure is network acl or protocol service is down but technician orders replacement media. The targeted evidence is check actual target listener and server service together with test client path and applicable network acls, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Inspect ONTAP VLAN object and parent port may be appropriate for a separate vlan tags and switch port mode case, but is not the most discriminating check in this incident: NFS mounts fail only across one firewall while local clients can mount normally.. The described failure is network acl or protocol service is down but technician orders replacement media. The targeted evidence is check actual target listener and server service together with test client path and applicable network acls, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Test path MTU along the storage route may be appropriate for a separate mtu continuity end to end case, but is not the most discriminating check in this incident: NFS mounts fail only across one firewall while local clients can mount normally.. The described failure is network acl or protocol service is down but technician orders replacement media. The targeted evidence is check actual target listener and server service together with test client path and applicable network acls, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.