Network Appliance NS0-094 Practice Test 70
Question 690
Fictional NetApp hardware-support incident R376-C173: A new Linux host pings the array management port but has no path to iSCSI target portal. Which verification would directly support or reject the proposed diagnosis?
- Check ONTAP LUN map and igroup membership
- Check network path to target portals
- Inspect matching export policy rules
- Compare host WWPN and target WWPN zones
Explanation
Correct Answer
B:Check network path to target portals is directly relevant evidence for the iscsi target discovery and session scenario. Pair it with inspect initiator login and session status when both are called for to establish whether host cannot discover lun because its target is unreachable. The support case reports A new Linux host pings the array management port but has no path to iSCSI target portal.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that supported initiator logs in and sees the intended presented lun. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Check ONTAP LUN map and igroup membership may be appropriate for a separate lun mapping and igroup case, but is not the most discriminating check in this incident: A new Linux host pings the array management port but has no path to iSCSI target portal.. The described failure is host cannot discover lun because its target is unreachable. The targeted evidence is check network path to target portals together with inspect initiator login and session status, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Inspect matching export policy rules may be appropriate for a separate nfs export policy specificity case, but is not the most discriminating check in this incident: A new Linux host pings the array management port but has no path to iSCSI target portal.. The described failure is host cannot discover lun because its target is unreachable. The targeted evidence is check network path to target portals together with inspect initiator login and session status, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Compare host WWPN and target WWPN zones may be appropriate for a separate fibre channel zoning correctness case, but is not the most discriminating check in this incident: A new Linux host pings the array management port but has no path to iSCSI target portal.. The described failure is host cannot discover lun because its target is unreachable. The targeted evidence is check network path to target portals together with inspect initiator login and session status, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 691
Fictional NetApp hardware-support incident R376-C173: A new Linux host pings the array management port but has no path to iSCSI target portal. What assumption should the engineer reject before touching equipment?
- LIF uses a VLAN not carried through the upstream switch
- Ports from unrelated layer 2 networks are treated as one failover domain
- Host cannot discover LUN because its target is unreachable
- One device drops jumbo frames despite others advertising high MTU
Explanation
Correct Answer
C:Host cannot discover LUN because its target is unreachable. This diagnosis fits the original incident, A new Linux host pings the array management port but has no path to iSCSI target portal., rather than requiring an unrelated service action. Check check network path to target portals and inspect initiator login and session status to confirm the location and status of the affected resource. The relevant corrective response is trace initiator to svm data lif, target portal and established iscsi session before blaming media, with final acceptance when supported initiator logs in and sees the intended presented lun. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
A:LIF uses a VLAN not carried through the upstream switch describes a possible failure in the neighboring topic VLAN tags and switch port mode, not the main mechanism demonstrated here. The actual scenario is A new Linux host pings the array management port but has no path to iSCSI target portal.; the more direct diagnosis is host cannot discover lun because its target is unreachable. Confirm it from check network path to target portals and inspect initiator login and session status before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
B:Ports from unrelated layer 2 networks are treated as one failover domain describes a possible failure in the neighboring topic Broadcast domains and ports, not the main mechanism demonstrated here. The actual scenario is A new Linux host pings the array management port but has no path to iSCSI target portal.; the more direct diagnosis is host cannot discover lun because its target is unreachable. Confirm it from check network path to target portals and inspect initiator login and session status before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
D:One device drops jumbo frames despite others advertising high MTU describes a possible failure in the neighboring topic MTU continuity end to end, not the main mechanism demonstrated here. The actual scenario is A new Linux host pings the array management port but has no path to iSCSI target portal.; the more direct diagnosis is host cannot discover lun because its target is unreachable. Confirm it from check network path to target portals and inspect initiator login and session status before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 692
Fictional NetApp hardware-support incident R376-C173: A new Linux host pings the array management port but has no path to iSCSI target portal. Which test result best shows restoration of the intended protected behavior?
- LIF target ports share actual reachable connectivity
- Storage transport works reliably at a mutually supported MTU
- Cluster communication stays healthy independent of client data services
- Supported initiator logs in and sees the intended presented LUN
Explanation
Correct Answer
D:Supported initiator logs in and sees the intended presented LUN. This outcome would specifically test whether host cannot discover lun because its target is unreachable has been corrected in the fictional situation: A new Linux host pings the array management port but has no path to iSCSI target portal.. It should follow the supported response trace initiator to svm data lif, target portal and established iscsi session before blaming media, with evidence from check network path to target portals and inspect initiator login and session status. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:LIF target ports share actual reachable connectivity could be a positive validation for the adjacent topic Broadcast domains and ports, but is insufficient to close this fault. The case reports A new Linux host pings the array management port but has no path to iSCSI target portal.. Its direct acceptance condition is that supported initiator logs in and sees the intended presented lun, after the appropriate action trace initiator to svm data lif, target portal and established iscsi session before blaming media. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Storage transport works reliably at a mutually supported MTU could be a positive validation for the adjacent topic MTU continuity end to end, but is insufficient to close this fault. The case reports A new Linux host pings the array management port but has no path to iSCSI target portal.. Its direct acceptance condition is that supported initiator logs in and sees the intended presented lun, after the appropriate action trace initiator to svm data lif, target portal and established iscsi session before blaming media. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Cluster communication stays healthy independent of client data services could be a positive validation for the adjacent topic Cluster network isolation, but is insufficient to close this fault. The case reports A new Linux host pings the array management port but has no path to iSCSI target portal.. Its direct acceptance condition is that supported initiator logs in and sees the intended presented lun, after the appropriate action trace initiator to svm data lif, target portal and established iscsi session before blaming media. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 693
Fictional NetApp hardware-support incident R376-C174: An iSCSI initiator is configured with the wrong discovery IP and lists no targets. Which approved diagnostic or corrective step should be selected first?
- Trace initiator to SVM data LIF, target portal and established iSCSI session before blaming media
- Verify export rules, client match and access protocols before assigning a NAS client outage to hardware
- Confirm initiator/target WWPN zoning and port states for supported FC host access
- Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health
Explanation
Correct Answer
A:Trace initiator to SVM data LIF, target portal and established iSCSI session before blaming media. This is the targeted supported response because host cannot discover lun because its target is unreachable. The fictional incident is: An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. The technician should first correlate check network path to target portals with inspect initiator login and session status, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that supported initiator logs in and sees the intended presented lun. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
B:Verify export rules, client match and access protocols before assigning a NAS client outage to hardware is a legitimate focus when investigating NFS export policy specificity, but it does not resolve the reported iscsi target discovery and session failure. In this particular incident, An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. The decisive checks are check network path to target portals and inspect initiator login and session status; these isolate why host cannot discover lun because its target is unreachable. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is trace initiator to svm data lif, target portal and established iscsi session before blaming media. Expert review has not yet confirmed option exclusivity.
C:Confirm initiator/target WWPN zoning and port states for supported FC host access is a legitimate focus when investigating Fibre Channel zoning correctness, but it does not resolve the reported iscsi target discovery and session failure. In this particular incident, An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. The decisive checks are check network path to target portals and inspect initiator login and session status; these isolate why host cannot discover lun because its target is unreachable. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is trace initiator to svm data lif, target portal and established iscsi session before blaming media. Expert review has not yet confirmed option exclusivity.
D:Separate SMB share permissions, NTFS ACLs and domain authentication from storage device health is a legitimate focus when investigating SMB share and authentication, but it does not resolve the reported iscsi target discovery and session failure. In this particular incident, An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. The decisive checks are check network path to target portals and inspect initiator login and session status; these isolate why host cannot discover lun because its target is unreachable. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is trace initiator to svm data lif, target portal and established iscsi session before blaming media. Expert review has not yet confirmed option exclusivity.
Question 694
Fictional NetApp hardware-support incident R376-C174: An iSCSI initiator is configured with the wrong discovery IP and lists no targets. Which verification would directly support or reject the proposed diagnosis?
- Inspect matching export policy rules
- Check network path to target portals
- Compare host WWPN and target WWPN zones
- Check share and file ACLs
Explanation
Correct Answer
B:Check network path to target portals is directly relevant evidence for the iscsi target discovery and session scenario. Pair it with inspect initiator login and session status when both are called for to establish whether host cannot discover lun because its target is unreachable. The support case reports An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that supported initiator logs in and sees the intended presented lun. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Inspect matching export policy rules may be appropriate for a separate nfs export policy specificity case, but is not the most discriminating check in this incident: An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. The described failure is host cannot discover lun because its target is unreachable. The targeted evidence is check network path to target portals together with inspect initiator login and session status, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Compare host WWPN and target WWPN zones may be appropriate for a separate fibre channel zoning correctness case, but is not the most discriminating check in this incident: An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. The described failure is host cannot discover lun because its target is unreachable. The targeted evidence is check network path to target portals together with inspect initiator login and session status, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Check share and file ACLs may be appropriate for a separate smb share and authentication case, but is not the most discriminating check in this incident: An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. The described failure is host cannot discover lun because its target is unreachable. The targeted evidence is check network path to target portals together with inspect initiator login and session status, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 695
Fictional NetApp hardware-support incident R376-C174: An iSCSI initiator is configured with the wrong discovery IP and lists no targets. What is the principal engineering fault indicated by the scenario?
- Ports from unrelated layer 2 networks are treated as one failover domain
- Host cannot see LUN because SAN fabric zoning omits its initiator
- Host cannot discover LUN because its target is unreachable
- Cluster traffic is connected through the client data path or wrong VLAN
Explanation
Correct Answer
C:Host cannot discover LUN because its target is unreachable. This diagnosis fits the original incident, An iSCSI initiator is configured with the wrong discovery IP and lists no targets., rather than requiring an unrelated service action. Check check network path to target portals and inspect initiator login and session status to confirm the location and status of the affected resource. The relevant corrective response is trace initiator to svm data lif, target portal and established iscsi session before blaming media, with final acceptance when supported initiator logs in and sees the intended presented lun. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
A:Ports from unrelated layer 2 networks are treated as one failover domain describes a possible failure in the neighboring topic Broadcast domains and ports, not the main mechanism demonstrated here. The actual scenario is An iSCSI initiator is configured with the wrong discovery IP and lists no targets.; the more direct diagnosis is host cannot discover lun because its target is unreachable. Confirm it from check network path to target portals and inspect initiator login and session status before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
B:Host cannot see LUN because SAN fabric zoning omits its initiator describes a possible failure in the neighboring topic Fibre Channel zoning correctness, not the main mechanism demonstrated here. The actual scenario is An iSCSI initiator is configured with the wrong discovery IP and lists no targets.; the more direct diagnosis is host cannot discover lun because its target is unreachable. Confirm it from check network path to target portals and inspect initiator login and session status before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
D:Cluster traffic is connected through the client data path or wrong VLAN describes a possible failure in the neighboring topic Cluster network isolation, not the main mechanism demonstrated here. The actual scenario is An iSCSI initiator is configured with the wrong discovery IP and lists no targets.; the more direct diagnosis is host cannot discover lun because its target is unreachable. Confirm it from check network path to target portals and inspect initiator login and session status before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 696
Fictional NetApp hardware-support incident R376-C174: An iSCSI initiator is configured with the wrong discovery IP and lists no targets. Which post-service observation best demonstrates the specific problem is resolved?
- Required client subnet is reachable on the correct VLAN
- Authorized NFS mount succeeds under intended rules
- Storage transport works reliably at a mutually supported MTU
- Supported initiator logs in and sees the intended presented LUN
Explanation
Correct Answer
D:Supported initiator logs in and sees the intended presented LUN. This outcome would specifically test whether host cannot discover lun because its target is unreachable has been corrected in the fictional situation: An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. It should follow the supported response trace initiator to svm data lif, target portal and established iscsi session before blaming media, with evidence from check network path to target portals and inspect initiator login and session status. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Required client subnet is reachable on the correct VLAN could be a positive validation for the adjacent topic VLAN tags and switch port mode, but is insufficient to close this fault. The case reports An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. Its direct acceptance condition is that supported initiator logs in and sees the intended presented lun, after the appropriate action trace initiator to svm data lif, target portal and established iscsi session before blaming media. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Authorized NFS mount succeeds under intended rules could be a positive validation for the adjacent topic NFS export policy specificity, but is insufficient to close this fault. The case reports An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. Its direct acceptance condition is that supported initiator logs in and sees the intended presented lun, after the appropriate action trace initiator to svm data lif, target portal and established iscsi session before blaming media. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Storage transport works reliably at a mutually supported MTU could be a positive validation for the adjacent topic MTU continuity end to end, but is insufficient to close this fault. The case reports An iSCSI initiator is configured with the wrong discovery IP and lists no targets.. Its direct acceptance condition is that supported initiator logs in and sees the intended presented lun, after the appropriate action trace initiator to svm data lif, target portal and established iscsi session before blaming media. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
Question 697
Fictional NetApp hardware-support incident R376-C175: A replacement HBA carries a new WWPN but switches retain the old zoning. What action should the field engineer take before closing this specific maintenance finding?
- Confirm initiator/target WWPN zoning and port states for supported FC host access
- Confirm host and ONTAP VLAN IDs and switch trunk/access settings before treating lost link as hardware failure
- Verify export rules, client match and access protocols before assigning a NAS client outage to hardware
- Verify network MTU across host, switch and ONTAP ports for large frames
Explanation
Correct Answer
A:Confirm initiator/target WWPN zoning and port states for supported FC host access. This is the targeted supported response because host cannot see lun because san fabric zoning omits its initiator. The fictional incident is: A replacement HBA carries a new WWPN but switches retain the old zoning.. The technician should first correlate compare host wwpn and target wwpn zones with inspect fabric and ontap fc target lif online state, then apply the model-specific guide rather than improvising a live component swap. Acceptance requires that appropriate host paths are visible through approved fc zones. The chosen step is author-intended and still needs an independent NetApp-platform expert check.
Incorrect Answers
B:Confirm host and ONTAP VLAN IDs and switch trunk/access settings before treating lost link as hardware failure is a legitimate focus when investigating VLAN tags and switch port mode, but it does not resolve the reported fibre channel zoning correctness failure. In this particular incident, A replacement HBA carries a new WWPN but switches retain the old zoning.. The decisive checks are compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state; these isolate why host cannot see lun because san fabric zoning omits its initiator. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm initiator/target wwpn zoning and port states for supported fc host access. Expert review has not yet confirmed option exclusivity.
C:Verify export rules, client match and access protocols before assigning a NAS client outage to hardware is a legitimate focus when investigating NFS export policy specificity, but it does not resolve the reported fibre channel zoning correctness failure. In this particular incident, A replacement HBA carries a new WWPN but switches retain the old zoning.. The decisive checks are compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state; these isolate why host cannot see lun because san fabric zoning omits its initiator. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm initiator/target wwpn zoning and port states for supported fc host access. Expert review has not yet confirmed option exclusivity.
D:Verify network MTU across host, switch and ONTAP ports for large frames is a legitimate focus when investigating MTU continuity end to end, but it does not resolve the reported fibre channel zoning correctness failure. In this particular incident, A replacement HBA carries a new WWPN but switches retain the old zoning.. The decisive checks are compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state; these isolate why host cannot see lun because san fabric zoning omits its initiator. Changing a different component or workflow before resolving that evidence would add maintenance risk. The more direct course is confirm initiator/target wwpn zoning and port states for supported fc host access. Expert review has not yet confirmed option exclusivity.
Question 698
Fictional NetApp hardware-support incident R376-C175: A replacement HBA carries a new WWPN but switches retain the old zoning. Which verification would directly support or reject the proposed diagnosis?
- Check share and file ACLs
- Compare host WWPN and target WWPN zones
- Inspect ONTAP VLAN object and parent port
- Check network path to target portals
Explanation
Correct Answer
B:Compare host WWPN and target WWPN zones is directly relevant evidence for the fibre channel zoning correctness scenario. Pair it with inspect fabric and ontap fc target lif online state when both are called for to establish whether host cannot see lun because san fabric zoning omits its initiator. The support case reports A replacement HBA carries a new WWPN but switches retain the old zoning.. Keeping original observations before repair allows the technician to distinguish an actual defective component from a secondary alert; after correction verify that appropriate host paths are visible through approved fc zones. This is an author-intended diagnostic choice requiring human technical confirmation.
Incorrect Answers
A:Check share and file ACLs may be appropriate for a separate smb share and authentication case, but is not the most discriminating check in this incident: A replacement HBA carries a new WWPN but switches retain the old zoning.. The described failure is host cannot see lun because san fabric zoning omits its initiator. The targeted evidence is compare host wwpn and target wwpn zones together with inspect fabric and ontap fc target lif online state, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
C:Inspect ONTAP VLAN object and parent port may be appropriate for a separate vlan tags and switch port mode case, but is not the most discriminating check in this incident: A replacement HBA carries a new WWPN but switches retain the old zoning.. The described failure is host cannot see lun because san fabric zoning omits its initiator. The targeted evidence is compare host wwpn and target wwpn zones together with inspect fabric and ontap fc target lif online state, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
D:Check network path to target portals may be appropriate for a separate iscsi target discovery and session case, but is not the most discriminating check in this incident: A replacement HBA carries a new WWPN but switches retain the old zoning.. The described failure is host cannot see lun because san fabric zoning omits its initiator. The targeted evidence is compare host wwpn and target wwpn zones together with inspect fabric and ontap fc target lif online state, before following the supported corrective action. A reviewer must assess whether any alternative offers a plausible secondary check before accepting the key.
Question 699
Fictional NetApp hardware-support incident R376-C175: A replacement HBA carries a new WWPN but switches retain the old zoning. Which underlying failure mechanism most directly explains the documented symptoms?
- One device drops jumbo frames despite others advertising high MTU
- Host cannot discover LUN because its target is unreachable
- Host cannot see LUN because SAN fabric zoning omits its initiator
- LIF uses a VLAN not carried through the upstream switch
Explanation
Correct Answer
C:Host cannot see LUN because SAN fabric zoning omits its initiator. This diagnosis fits the original incident, A replacement HBA carries a new WWPN but switches retain the old zoning., rather than requiring an unrelated service action. Check compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state to confirm the location and status of the affected resource. The relevant corrective response is confirm initiator/target wwpn zoning and port states for supported fc host access, with final acceptance when appropriate host paths are visible through approved fc zones. The author-intended diagnosis has not yet received independent support engineering validation.
Incorrect Answers
A:One device drops jumbo frames despite others advertising high MTU describes a possible failure in the neighboring topic MTU continuity end to end, not the main mechanism demonstrated here. The actual scenario is A replacement HBA carries a new WWPN but switches retain the old zoning.; the more direct diagnosis is host cannot see lun because san fabric zoning omits its initiator. Confirm it from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
B:Host cannot discover LUN because its target is unreachable describes a possible failure in the neighboring topic ISCSI target discovery and session, not the main mechanism demonstrated here. The actual scenario is A replacement HBA carries a new WWPN but switches retain the old zoning.; the more direct diagnosis is host cannot see lun because san fabric zoning omits its initiator. Confirm it from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
D:LIF uses a VLAN not carried through the upstream switch describes a possible failure in the neighboring topic VLAN tags and switch port mode, not the main mechanism demonstrated here. The actual scenario is A replacement HBA carries a new WWPN but switches retain the old zoning.; the more direct diagnosis is host cannot see lun because san fabric zoning omits its initiator. Confirm it from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state before considering broader corrective work. Adjacent failures may coexist in real arrays, so an expert must review whether the distractor could also plausibly apply.
Question 700
Fictional NetApp hardware-support incident R376-C175: A replacement HBA carries a new WWPN but switches retain the old zoning. What measurable acceptance condition should the reviewer require after corrective work?
- Supported initiator logs in and sees the intended presented LUN
- Protocol connectivity is restored by a scoped network or service fix
- Cluster communication stays healthy independent of client data services
- Appropriate host paths are visible through approved FC zones
Explanation
Correct Answer
D:Appropriate host paths are visible through approved FC zones. This outcome would specifically test whether host cannot see lun because san fabric zoning omits its initiator has been corrected in the fictional situation: A replacement HBA carries a new WWPN but switches retain the old zoning.. It should follow the supported response confirm initiator/target wwpn zoning and port states for supported fc host access, with evidence from compare host wwpn and target wwpn zones and inspect fabric and ontap fc target lif online state. A green indicator alone is insufficient if customer storage availability or redundancy remains degraded. This intended acceptance target remains subject to human review.
Incorrect Answers
A:Supported initiator logs in and sees the intended presented LUN could be a positive validation for the adjacent topic ISCSI target discovery and session, but is insufficient to close this fault. The case reports A replacement HBA carries a new WWPN but switches retain the old zoning.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
B:Protocol connectivity is restored by a scoped network or service fix could be a positive validation for the adjacent topic Protocol port scope and firewall, but is insufficient to close this fault. The case reports A replacement HBA carries a new WWPN but switches retain the old zoning.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.
C:Cluster communication stays healthy independent of client data services could be a positive validation for the adjacent topic Cluster network isolation, but is insufficient to close this fault. The case reports A replacement HBA carries a new WWPN but switches retain the old zoning.. Its direct acceptance condition is that appropriate host paths are visible through approved fc zones, after the appropriate action confirm initiator/target wwpn zoning and port states for supported fc host access. Compare actual hardware and ONTAP evidence rather than inferring success from an unrelated performance or configuration improvement. A qualified engineer must review this distinction.