cert
cert-1
cert-2

Pass Fortinet NSE5_FSW_AD-7.6 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
NSE5_FSW_AD-7.6 Exam - Verified By Experts
NSE5_FSW_AD-7.6 Premium File

NSE5_FSW_AD-7.6 Premium File

$69.99
$76.99
  • Premium File 64 Questions & Answers. Last Update: Nov 15, 2026

Whats Included:

  • Latest Questions
  • 100% Accurate Answers
  • Fast Exam Updates
 
$76.99
$69.99
accept 42 downloads in the last 7 days
block-screenshots
Fortinet NSE5_FSW_AD-7.6 Practice Test 73

Question 720

A newly patched uplink reports an unexpected LLDP peer from a separate customer zone. Which TWO complementary steps identify the appropriate FortiSwitch response AND the evidence needed to verify it? Select TWO.

  1. Inspect local and neighbor port IDs, timestamp, learned MAC per VLAN, trunk member and expected cabling map.
  2. Correlate LLDP neighbor inventory and VLAN-specific MAC entries to reconstruct actual endpoint and uplink paths.
  3. Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.
  4. Phones and access points receive stable allocated power while redundant PSU and priority policies remain within budget.
  5. Collect relevant FortiSwitch controller diagnostics, switch system events and targeted status output before making configuration changes.

Explanation

Correct Answers

A:

Inspect local and neighbor port IDs, timestamp, learned MAC per VLAN, trunk member and expected cabling map. LLDP provides adjacent-device identity, while MAC learning maps forwarding; neither is a full routed trace by itself. The paired action is: Correlate LLDP neighbor inventory and VLAN-specific MAC entries to reconstruct actual endpoint and uplink paths. This is the diagnostic or verification half of the requested TWO-step pair.

B:

Correlate LLDP neighbor inventory and VLAN-specific MAC entries to reconstruct actual endpoint and uplink paths. LLDP provides adjacent-device identity, while MAC learning maps forwarding; neither is a full routed trace by itself. Verify the action with: Inspect local and neighbor port IDs, timestamp, learned MAC per VLAN, trunk member and expected cabling map. This is the configuration or remediation half of the requested TWO-step pair.

Incorrect Answers

C:

Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy. This step concerns SNMP and sFlow monitoring configuration and is not part of the required paired solution. The correct action and evidence are: Correlate LLDP neighbor inventory and VLAN-specific MAC entries to reconstruct actual endpoint and uplink paths. Together with: Inspect local and neighbor port IDs, timestamp, learned MAC per VLAN, trunk member and expected cabling map.

D:

Phones and access points receive stable allocated power while redundant PSU and priority policies remain within budget. This step concerns PoE and LLDP-MED endpoint power coordination and is not part of the required paired solution. The correct action and evidence are: Correlate LLDP neighbor inventory and VLAN-specific MAC entries to reconstruct actual endpoint and uplink paths. Together with: Inspect local and neighbor port IDs, timestamp, learned MAC per VLAN, trunk member and expected cabling map.

E:

Collect relevant FortiSwitch controller diagnostics, switch system events and targeted status output before making configuration changes. This step concerns FortiSwitch diagnostic commands and logs and is not part of the required paired solution. The correct action and evidence are: Correlate LLDP neighbor inventory and VLAN-specific MAC entries to reconstruct actual endpoint and uplink paths. Together with: Inspect local and neighbor port IDs, timestamp, learned MAC per VLAN, trunk member and expected cabling map.

Question 721

An operations platform sees no FortiSwitch traffic samples because the configured sFlow collector address is wrong. Which TWO complementary steps identify the appropriate FortiSwitch response AND the evidence needed to verify it? Select TWO.

  1. Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope.
  2. An access host receives the right subnet while only approved tagged VLANs traverse the uplink.
  3. Retrieve and maintain approved FortiSwitch model, firmware, configuration and authorized-controller records to support incident recovery.
  4. Verify mirror connection, FortiGate sniffing interface, capture expression, expected VLAN tags and packet direction.
  5. Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.

Explanation

Correct Answers

A:

Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. Flow samples are estimates and counters vary by port; collecting telemetry cannot replace a controlled packet capture when headers are needed. Verify the action with: Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy. This is the configuration or remediation half of the requested TWO-step pair.

E:

Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy. Flow samples are estimates and counters vary by port; collecting telemetry cannot replace a controlled packet capture when headers are needed. The paired action is: Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. This is the diagnostic or verification half of the requested TWO-step pair.

Incorrect Answers

B:

An access host receives the right subnet while only approved tagged VLANs traverse the uplink. This step concerns FortiSwitch native VLAN versus allowed VLANs and is not part of the required paired solution. The correct action and evidence are: Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. Together with: Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.

C:

Retrieve and maintain approved FortiSwitch model, firmware, configuration and authorized-controller records to support incident recovery. This step concerns Config backup and firmware inventory evidence and is not part of the required paired solution. The correct action and evidence are: Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. Together with: Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.

D:

Verify mirror connection, FortiGate sniffing interface, capture expression, expected VLAN tags and packet direction. This step concerns FortiGate one-arm sniffer across managed switching and is not part of the required paired solution. The correct action and evidence are: Collect supported SNMP or sFlow telemetry securely with appropriate collector authorization, sampling and interface scope. Together with: Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.

Question 722

A switch has IGMP snooping enabled but no effective querier and group entries age out unexpectedly. Which observable result BEST proves the intended FortiSwitch operation or security policy works?

  1. Each intended managed switch appears with valid upstream connectivity and no unintended layer-2 loop.
  2. Hosts can reach their intended SVI and authorized routed destinations without overlapping address space.
  3. Managed status remains healthy and user traffic uses only its intended FortiLink-carried VLANs.
  4. Members receive subscribed streams while unsubscribed access ports are not flooded unnecessarily.

Explanation

Correct Answer

D:

Members receive subscribed streams while unsubscribed access ports are not flooded unnecessarily. A multicast VLAN alone does not indicate that IGMP receiver membership or querier operation is healthy.

Incorrect Answers

A:

Each intended managed switch appears with valid upstream connectivity and no unintended layer-2 loop. This result relates to FortiLink ISL auto-discovery and stack cabling, not the acceptance condition under test. The relevant result is: Members receive subscribed streams while unsubscribed access ports are not flooded unnecessarily.

B:

Hosts can reach their intended SVI and authorized routed destinations without overlapping address space. This result relates to FortiSwitch SVI routing and connected routes, not the acceptance condition under test. The relevant result is: Members receive subscribed streams while unsubscribed access ports are not flooded unnecessarily.

C:

Managed status remains healthy and user traffic uses only its intended FortiLink-carried VLANs. This result relates to FortiLink control and client VLAN transport separation, not the acceptance condition under test. The relevant result is: Members receive subscribed streams while unsubscribed access ports are not flooded unnecessarily.

Question 723

Voice packets show the correct DSCP but the uplink queues them as ordinary best-effort traffic. Which TWO complementary steps identify the appropriate FortiSwitch response AND the evidence needed to verify it? Select TWO.

  1. Use supported native and voice VLAN policies so phones and downstream workstations receive appropriate separate traffic treatment.
  2. Review spanning-tree topology-change count, MAC instability, BPDU logs, port errors and recent cabling changes.
  3. Inspect incoming 802.1p and DSCP markings, trust mode, QoS map, physical port and classification counters.
  4. Runaway flooding is contained without blocking legitimate broadcast-based onboarding or multicast subscribers.
  5. Define appropriate trusted ingress marking sources and classify untrusted frames before choosing egress queues.

Explanation

Correct Answers

C:

Inspect incoming 802.1p and DSCP markings, trust mode, QoS map, physical port and classification counters. A packet marking has no useful QoS effect until supported classification and scheduling map it consistently. The paired action is: Define appropriate trusted ingress marking sources and classify untrusted frames before choosing egress queues. This is the diagnostic or verification half of the requested TWO-step pair.

E:

Define appropriate trusted ingress marking sources and classify untrusted frames before choosing egress queues. A packet marking has no useful QoS effect until supported classification and scheduling map it consistently. Verify the action with: Inspect incoming 802.1p and DSCP markings, trust mode, QoS map, physical port and classification counters. This is the configuration or remediation half of the requested TWO-step pair.

Incorrect Answers

A:

Use supported native and voice VLAN policies so phones and downstream workstations receive appropriate separate traffic treatment. This step concerns Voice and data VLAN separation on shared access ports and is not part of the required paired solution. The correct action and evidence are: Define appropriate trusted ingress marking sources and classify untrusted frames before choosing egress queues. Together with: Inspect incoming 802.1p and DSCP markings, trust mode, QoS map, physical port and classification counters.

B:

Review spanning-tree topology-change count, MAC instability, BPDU logs, port errors and recent cabling changes. This step concerns STP incident recovery with MAC flap evidence and is not part of the required paired solution. The correct action and evidence are: Define appropriate trusted ingress marking sources and classify untrusted frames before choosing egress queues. Together with: Inspect incoming 802.1p and DSCP markings, trust mode, QoS map, physical port and classification counters.

D:

Runaway flooding is contained without blocking legitimate broadcast-based onboarding or multicast subscribers. This step concerns Storm-control thresholds and broadcast containment and is not part of the required paired solution. The correct action and evidence are: Define appropriate trusted ingress marking sources and classify untrusted frames before choosing egress queues. Together with: Inspect incoming 802.1p and DSCP markings, trust mode, QoS map, physical port and classification counters.

Question 724

A static-IP printer loses connectivity after DAI is turned on with no manual binding exception. Which observable result BEST proves the intended FortiSwitch operation or security policy works?

  1. Switches reconnect to FortiLink and preserve approved VLAN/role configuration after the planned upgrade.
  2. Authorized endpoints enter only permitted VLANs while failed authentication is denied or restricted according to policy.
  3. Spoofed ARP replies are dropped while legitimate endpoints maintain gateway ARP resolution.
  4. Only approved DHCP servers issue leases and the assigned endpoint identity or location remains traceable.

Explanation

Correct Answer

C:

Spoofed ARP replies are dropped while legitimate endpoints maintain gateway ARP resolution. DAI validation needs a reliable binding or exception policy; enabling it blindly can interrupt static-IP devices.

Incorrect Answers

A:

Switches reconnect to FortiLink and preserve approved VLAN/role configuration after the planned upgrade. This result relates to Firmware and lifecycle preparation for FortiSwitch, not the acceptance condition under test. The relevant result is: Spoofed ARP replies are dropped while legitimate endpoints maintain gateway ARP resolution.

B:

Authorized endpoints enter only permitted VLANs while failed authentication is denied or restricted according to policy. This result relates to FortiSwitch 802.1X port-based authentication, not the acceptance condition under test. The relevant result is: Spoofed ARP replies are dropped while legitimate endpoints maintain gateway ARP resolution.

D:

Only approved DHCP servers issue leases and the assigned endpoint identity or location remains traceable. This result relates to DHCP server allowlist and Option 82 validation, not the acceptance condition under test. The relevant result is: Spoofed ARP replies are dropped while legitimate endpoints maintain gateway ARP resolution.

Question 725

An engineer removes an obsolete customer VLAN from a shared trunk without checking another tenant still uses it. Which observable result BEST proves the intended FortiSwitch operation or security policy works?

  1. A tenant reaches only its approved VDOM resources and does not inherit another tenant's policies.
  2. Two tenants can use the supported shared port without accidental cross-tenant broadcasts or privilege escalation.
  3. The intended tenant configuration changes while other tenants retain their segmentation and service.
  4. Voice packets receive intended treatment without allowing arbitrary untrusted hosts to claim top priority.

Explanation

Correct Answer

C:

The intended tenant configuration changes while other tenants retain their segmentation and service. A change on shared physical transport can affect multiple VDOMs, even if each tenant's firewall policy is separate.

Incorrect Answers

A:

A tenant reaches only its approved VDOM resources and does not inherit another tenant's policies. This result relates to FortiGate VDOM-based FortiSwitch tenant assignment, not the acceptance condition under test. The relevant result is: The intended tenant configuration changes while other tenants retain their segmentation and service.

B:

Two tenants can use the supported shared port without accidental cross-tenant broadcasts or privilege escalation. This result relates to Shared port multi-VDOM policy boundaries, not the acceptance condition under test. The relevant result is: The intended tenant configuration changes while other tenants retain their segmentation and service.

D:

Voice packets receive intended treatment without allowing arbitrary untrusted hosts to claim top priority. This result relates to QoS ingress classification and trust boundaries, not the acceptance condition under test. The relevant result is: The intended tenant configuration changes while other tenants retain their segmentation and service.

Question 726

A device dashboard shows an average rate that hides short bursts of dropped voice traffic. Which diagnostic evidence should the FortiSwitch administrator examine FIRST?

  1. Inspect local and neighbor port IDs, timestamp, learned MAC per VLAN, trunk member and expected cabling map.
  2. Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy.
  3. Review frame error type, CRC/FCS, traffic rates, drops, operational speed, port description and sampled timestamps.
  4. Inspect supported topology, FortiLink p2p settings, TPID, transport reachability, discovery frames and switch firmware.

Explanation

Correct Answer

C:

Review frame error type, CRC/FCS, traffic rates, drops, operational speed, port description and sampled timestamps. A port-up indicator or one successful ping is not proof that a congested or errored uplink is healthy. The paired action is: Use FortiGate FortiSwitch Ports statistics or supported switch commands to isolate errors, utilization and port status at the right location.

Incorrect Answers

A:

Inspect local and neighbor port IDs, timestamp, learned MAC per VLAN, trunk member and expected cabling map. These observations are applicable to LLDP and MAC forwarding table extraction, but would not isolate the main failure first. The decisive evidence is: Review frame error type, CRC/FCS, traffic rates, drops, operational speed, port description and sampled timestamps.

B:

Inspect monitoring credentials, SNMP version, sFlow export destination, sample rate, counter freshness and access policy. These observations are applicable to SNMP and sFlow monitoring configuration, but would not isolate the main failure first. The decisive evidence is: Review frame error type, CRC/FCS, traffic rates, drops, operational speed, port description and sampled timestamps.

D:

Inspect supported topology, FortiLink p2p settings, TPID, transport reachability, discovery frames and switch firmware. These observations are applicable to FortiLink transport over nontrivial L2 or L3 paths, but would not isolate the main failure first. The decisive evidence is: Review frame error type, CRC/FCS, traffic rates, drops, operational speed, port description and sampled timestamps.

Question 727

The active FortiGate is restarted before the team verifies how managed-switch authorization behaves on the peer. Which FortiSwitch configuration or corrective action BEST addresses the requirement?

  1. Plan FortiLink management under FortiGate HA with supported links, peer roles and deterministic failover tests.
  2. Choose supported FortiSwitchOS version and maintenance workflow compatible with the FortiGate version and topology.
  3. Use documented peer-group and downstream trunk configuration for MCLAG rather than creating ad hoc parallel Ethernet links.
  4. Create a bounded packet-capture profile on the right switch interface with a narrow filter, then start/stop and inspect frames.

Explanation

Correct Answer

A:

Plan FortiLink management under FortiGate HA with supported links, peer roles and deterministic failover tests. FortiGate HA design and FortiSwitch stacking/MCLAG are separate mechanisms; their failure paths must both be evaluated. Verify the action with: Inspect primary/secondary FortiGate roles, HA health, FortiLink uplinks, downstream switch topology and session continuity.

Incorrect Answers

B:

Choose supported FortiSwitchOS version and maintenance workflow compatible with the FortiGate version and topology. This action is relevant to Firmware and lifecycle preparation for FortiSwitch, not the controlling requirement in this case. A successful image upload does not prove switch operation or controller compatibility after reboot. The targeted response is: Plan FortiLink management under FortiGate HA with supported links, peer roles and deterministic failover tests.

C:

Use documented peer-group and downstream trunk configuration for MCLAG rather than creating ad hoc parallel Ethernet links. This action is relevant to MCLAG multichassis access redundancy, not the controlling requirement in this case. MCLAG requires peer coordination and correct downstream aggregation; it is not equivalent to connecting independent switches in parallel. The targeted response is: Plan FortiLink management under FortiGate HA with supported links, peer roles and deterministic failover tests.

D:

Create a bounded packet-capture profile on the right switch interface with a narrow filter, then start/stop and inspect frames. This action is relevant to FortiSwitch local packet-capture profile and filters, not the controlling requirement in this case. Packet captures are interface and filter scoped, and platform buffer limits differ; a capture file is not proof of all traffic on every switch port. The targeted response is: Plan FortiLink management under FortiGate HA with supported links, peer roles and deterministic failover tests.

Question 728

An untrusted edge switch discards a valid server Offer and the fault is blamed on DHCP service uptime. Which FortiSwitch configuration or corrective action BEST addresses the requirement?

  1. Verify that supported CoA or dynamic user security profiles are enforced on authenticated sessions under the deployed topology.
  2. Verify FortiLink management status and user VLAN reachability independently when a switch is authorized but clients fail.
  3. Investigate managed switch offline or configuration mismatch after firmware upgrade or controller resynchronization using both endpoints.
  4. Trace DHCP and ARP exchanges at ingress and uplink to distinguish missing requests from blocked or malformed responses.

Explanation

Correct Answer

D:

Trace DHCP and ARP exchanges at ingress and uplink to distinguish missing requests from blocked or malformed responses. A DHCP lease failure can originate at the client, switch, relay or server; capturing at one side alone is not always conclusive. Verify the action with: Inspect Discover/Offer/Request/Ack sequence, ARP requests/replies, VLAN tags, DHCP snooping and DAI counters.

Incorrect Answers

A:

Verify that supported CoA or dynamic user security profiles are enforced on authenticated sessions under the deployed topology. This action is relevant to RADIUS change of authorization and applied session policy, not the controlling requirement in this case. RADIUS authentication success is not proof that a downloadable ACL or CoA update was enforced; some modes have documented conditions. The targeted response is: Trace DHCP and ARP exchanges at ingress and uplink to distinguish missing requests from blocked or malformed responses.

B:

Verify FortiLink management status and user VLAN reachability independently when a switch is authorized but clients fail. This action is relevant to FortiLink control and client VLAN transport separation, not the controlling requirement in this case. FortiLink transports management and data; a successful controller heartbeat does not guarantee a user VLAN or firewall session is permitted. The targeted response is: Trace DHCP and ARP exchanges at ingress and uplink to distinguish missing requests from blocked or malformed responses.

C:

Investigate managed switch offline or configuration mismatch after firmware upgrade or controller resynchronization using both endpoints. This action is relevant to FortiLink synchronization and upgrade troubleshooting, not the controlling requirement in this case. Managed switches can be reachable at Layer 2 yet show stale policy after incompatible upgrade or failed controller push. The targeted response is: Trace DHCP and ARP exchanges at ingress and uplink to distinguish missing requests from blocked or malformed responses.

Question 729

An IP phone connects at 100M after a port configuration was mistakenly forced to that rate. Which TWO complementary steps identify the appropriate FortiSwitch response AND the evidence needed to verify it? Select TWO.

  1. Configure supported IGMP snooping and querier expectations to forward multicast only where receivers request it.
  2. Set only mutually supported Ethernet port rates and verify operational negotiation instead of forcing mismatched speeds.
  3. Check both peer capabilities, auto-negotiation, administrative speed, cable quality and CRC/FCS counters.
  4. Runaway flooding is contained without blocking legitimate broadcast-based onboarding or multicast subscribers.
  5. Inspect SVI admin state, VLAN membership, address and mask, connected route, ARP and intended upstream gateway.

Explanation

Correct Answers

B:

Set only mutually supported Ethernet port rates and verify operational negotiation instead of forcing mismatched speeds. Incorrect forced port speed or duplex can mimic application loss even when the VLAN configuration is valid. Verify the action with: Check both peer capabilities, auto-negotiation, administrative speed, cable quality and CRC/FCS counters. This is the configuration or remediation half of the requested TWO-step pair.

C:

Check both peer capabilities, auto-negotiation, administrative speed, cable quality and CRC/FCS counters. Incorrect forced port speed or duplex can mimic application loss even when the VLAN configuration is valid. The paired action is: Set only mutually supported Ethernet port rates and verify operational negotiation instead of forcing mismatched speeds. This is the diagnostic or verification half of the requested TWO-step pair.

Incorrect Answers

A:

Configure supported IGMP snooping and querier expectations to forward multicast only where receivers request it. This step concerns IGMP snooping and multicast receivers and is not part of the required paired solution. The correct action and evidence are: Set only mutually supported Ethernet port rates and verify operational negotiation instead of forcing mismatched speeds. Together with: Check both peer capabilities, auto-negotiation, administrative speed, cable quality and CRC/FCS counters.

D:

Runaway flooding is contained without blocking legitimate broadcast-based onboarding or multicast subscribers. This step concerns Storm-control thresholds and broadcast containment and is not part of the required paired solution. The correct action and evidence are: Set only mutually supported Ethernet port rates and verify operational negotiation instead of forcing mismatched speeds. Together with: Check both peer capabilities, auto-negotiation, administrative speed, cable quality and CRC/FCS counters.

E:

Inspect SVI admin state, VLAN membership, address and mask, connected route, ARP and intended upstream gateway. This step concerns FortiSwitch SVI routing and connected routes and is not part of the required paired solution. The correct action and evidence are: Set only mutually supported Ethernet port rates and verify operational negotiation instead of forcing mismatched speeds. Together with: Check both peer capabilities, auto-negotiation, administrative speed, cable quality and CRC/FCS counters.

Question 730

The active FortiGate is restarted before the team verifies how managed-switch authorization behaves on the peer. Which observable result BEST proves the intended FortiSwitch operation or security policy works?

  1. Voice packets receive intended treatment without allowing arbitrary untrusted hosts to claim top priority.
  2. The intended tenant configuration changes while other tenants retain their segmentation and service.
  3. A tenant reaches only its approved VDOM resources and does not inherit another tenant's policies.
  4. A controlled FortiGate HA failover leaves managed switches authorized and required client access functioning.

Explanation

Correct Answer

D:

A controlled FortiGate HA failover leaves managed switches authorized and required client access functioning. FortiGate HA design and FortiSwitch stacking/MCLAG are separate mechanisms; their failure paths must both be evaluated.

Incorrect Answers

A:

Voice packets receive intended treatment without allowing arbitrary untrusted hosts to claim top priority. This result relates to QoS ingress classification and trust boundaries, not the acceptance condition under test. The relevant result is: A controlled FortiGate HA failover leaves managed switches authorized and required client access functioning.

B:

The intended tenant configuration changes while other tenants retain their segmentation and service. This result relates to Multi-tenant change verification and rollback, not the acceptance condition under test. The relevant result is: A controlled FortiGate HA failover leaves managed switches authorized and required client access functioning.

C:

A tenant reaches only its approved VDOM resources and does not inherit another tenant's policies. This result relates to FortiGate VDOM-based FortiSwitch tenant assignment, not the acceptance condition under test. The relevant result is: A controlled FortiGate HA failover leaves managed switches authorized and required client access functioning.

Fortinet NSE 5 - FortiSwitch 7.6 Administrator (NSE5_FSW_AD-7.6) Practice Tests