cert
cert-1
cert-2

Pass CompTIA N10-009 Exam in First Attempt Guaranteed!

Get 100% Latest Exam Questions, Accurate & Verified Answers to Pass the Actual Exam!
30 Days Free Updates, Instant Download!

cert-5
cert-6
N10-009 Exam - Verified By Experts
N10-009 Premium Bundle
$29.98

N10-009 Premium Bundle

$79.99
$109.97
  • Premium File 768 Questions & Answers. Last update: Nov 13, 2026
  • Training Course 240 Video Lectures
  • Study Guide 128 Pages
 
$109.97
$79.99
accept 176 downloads in last 7 days
block-screenshots
Purchase CompTIA N10-009 Exam Training Products Individually
CompTIA N10-009 Premium File
Premium File 768 Q&A
$76.99$69.99
CompTIA N10-009 Video Training Course
Training Course 240 Lectures
$21.99 $19.99
CompTIA N10-009 PDF Study Guide
Study Guide 128 Pages
$21.99 $19.99
CompTIA N10-009 Practice Test 26

Question 250

Servers in VLAN 70 need an IP default gateway hosted directly on a multilayer switch. Which TWO entries together specify the appropriate corrective measure AND the strongest direct evidence that it works? (Select TWO.)

  1. Set a consistent supported jumbo-frame MTU along the entire intended path.
  2. Create an SVI for VLAN 70 and enable authorized layer-3 forwarding.
  3. Give a host-only loopback interface the same address as the SVI gateway.
  4. Apply inter-VLAN ACLs at the appropriate routed interfaces.
  5. Clients ARP for the SVI and reach an authorized remote subnet.

Explanation

Correct Answers

B:

Correct control. An SVI provides a logical routed interface for its switched VLAN. It addresses the present requirement: Servers in VLAN 70 need an IP default gateway hosted directly on a multilayer switch.

E:

Correct verification. Clients ARP for the SVI and reach an authorized remote subnet. This demonstrates the outcome expected from: Create an SVI for VLAN 70 and enable authorized layer-3 forwarding.

Incorrect Answers

A:

This control fits another scenario in objective 2.2: A storage fabric requires 9000-byte frames but an intermediate switch only allows the standard MTU. It does not directly verify or implement the present issue.

C:

Incorrect control. A local loopback does not provide the switched VLAN's reachable gateway. The inappropriate proposal is: Give a host-only loopback interface the same address as the SVI gateway.

D:

This is a response to a different later requirement: Traffic between VLANs must be restricted to application-specific ports. SVIs provide reachability but policy is needed to control it. It is not the original control-and-evidence pair.

Question 251

Servers in VLAN 70 need an IP default gateway hosted directly on a multilayer switch. After applying the solution 'Create an SVI for VLAN 70 and enable authorized layer-3 forwarding.', which observation MOST directly proves that the requirement was met?

  1. Approval is recorded for 'Create an SVI for VLAN 70 and enable authorized layer-3 forwarding.' but no operational validation is performed.
  2. Clients ARP for the SVI and reach an authorized remote subnet.
  3. End-to-end jumbo packet testing succeeds without unexpected drops.
  4. An unapproved test connection cannot join any production VLAN.

Explanation

Correct Answer

B:

Clients ARP for the SVI and reach an authorized remote subnet. It tests the intended outcome because an svi provides a logical routed interface for its switched vlan.

Incorrect Answers

A:

Approval alone does not demonstrate operating effectiveness. The missing direct test is: Clients ARP for the SVI and reach an authorized remote subnet.

C:

This observation is for a different condition: A storage fabric requires 9000-byte frames but an intermediate switch only allows the standard MTU. It does not directly test the target outcome: Servers in VLAN 70 need an IP default gateway hosted directly on a multilayer switch.

D:

This test addresses a separate problem: A security-sensitive VLAN has unused access ports left enabled and connected to wall jacks.

Question 252

The original case was: Servers in VLAN 70 need an IP default gateway hosted directly on a multilayer switch. The requirement then changes: Traffic between VLANs must be restricted to application-specific ports. Which revised action BEST meets this new condition?

  1. Apply inter-VLAN ACLs at the appropriate routed interfaces.
  2. Give a host-only loopback interface the same address as the SVI gateway.
  3. Create an SVI for VLAN 70 and enable authorized layer-3 forwarding.
  4. Clients ARP for the SVI and reach an authorized remote subnet.

Explanation

Correct Answer

A:

SVIs provide reachability but policy is needed to control it. The revised requirement is: Traffic between VLANs must be restricted to application-specific ports. The appropriate action is: Apply inter-VLAN ACLs at the appropriate routed interfaces.

Incorrect Answers

B:

A local loopback does not provide the switched VLAN's reachable gateway. It remains inappropriate in the revised context.

C:

This is the original control. An SVI provides a logical routed interface for its switched VLAN. It does not directly satisfy the revised requirement: Traffic between VLANs must be restricted to application-specific ports.

D:

Clients ARP for the SVI and reach an authorized remote subnet. The current requirement is: Traffic between VLANs must be restricted to application-specific ports.

Question 253

A 10G link reports large error rates after one end is forced to half duplex and the peer negotiates full duplex. Which action MOST directly meets the stated networking requirement?

  1. Change DNS TTL and assume interface errors are resolved.
  2. Correct speed and duplex settings to a mutually supported configuration.
  3. Validate transceiver and physical signaling compatibility before activation.
  4. Shut unused ports and assign a nonproduction VLAN under port-security policy.

Explanation

Correct Answer

B:

Duplex mismatch causes collisions or errors and poor throughput on affected links. This specifically resolves: A 10G link reports large error rates after one end is forced to half duplex and the peer negotiates full duplex.

Incorrect Answers

A:

Name-resolution cache times do not fix physical negotiation issues. The suggested approach is: Change DNS TTL and assume interface errors are resolved.

C:

This action responds to a later condition: The link upgrades to a new 25G port pair that requires matching optics. A speed upgrade introduces optical and PHY compatibility checks.

D:

This addresses another problem in objective 2.2: A security-sensitive VLAN has unused access ports left enabled and connected to wall jacks.

Question 254

A 10G link reports large error rates after one end is forced to half duplex and the peer negotiates full duplex. A colleague instead suggests: Change DNS TTL and assume interface errors are resolved. Which finding MOST specifically explains why that suggestion is unsuitable?

  1. Duplex mismatch causes collisions or errors and poor throughput on affected links.
  2. Name-resolution cache times do not fix physical negotiation issues.
  3. Auto trunking expands unintended layer-2 access if misused.
  4. A speed upgrade introduces optical and PHY compatibility checks.

Explanation

Correct Answer

B:

Name-resolution cache times do not fix physical negotiation issues. This flaw directly concerns the proposed action: Change DNS TTL and assume interface errors are resolved.

Incorrect Answers

A:

This explains why the recommended control works: Correct speed and duplex settings to a mutually supported configuration.

C:

This flaw concerns a different case in objective 2.2: A security-sensitive VLAN has unused access ports left enabled and connected to wall jacks. The current rejected proposal is: Change DNS TTL and assume interface errors are resolved.

D:

This rationale belongs to a later changed condition: The link upgrades to a new 25G port pair that requires matching optics.

Question 255

A 10G link reports large error rates after one end is forced to half duplex and the peer negotiates full duplex. After applying the solution 'Correct speed and duplex settings to a mutually supported configuration.', which observation MOST directly proves that the requirement was met?

  1. Approval is recorded for 'Correct speed and duplex settings to a mutually supported configuration.' but no operational validation is performed.
  2. An unapproved test connection cannot join any production VLAN.
  3. All switches report the intended root and appropriate designated or alternate roles.
  4. Both ports show expected duplex and the error counters stop increasing.

Explanation

Correct Answer

D:

Both ports show expected duplex and the error counters stop increasing. It tests the intended outcome because duplex mismatch causes collisions or errors and poor throughput on affected links.

Incorrect Answers

A:

Approval alone does not demonstrate operating effectiveness. The missing direct test is: Both ports show expected duplex and the error counters stop increasing.

B:

This observation is for a different condition: A security-sensitive VLAN has unused access ports left enabled and connected to wall jacks. It does not directly test the target outcome: A 10G link reports large error rates after one end is forced to half duplex and the peer negotiates full duplex.

C:

This test addresses a separate problem: A network wants to discover which switch became spanning-tree root after a maintenance change.

Question 256

The original case was: A 10G link reports large error rates after one end is forced to half duplex and the peer negotiates full duplex. The requirement then changes: The link upgrades to a new 25G port pair that requires matching optics. Which revised action BEST meets this new condition?

  1. Change DNS TTL and assume interface errors are resolved.
  2. Correct speed and duplex settings to a mutually supported configuration.
  3. Both ports show expected duplex and the error counters stop increasing.
  4. Validate transceiver and physical signaling compatibility before activation.

Explanation

Correct Answer

D:

A speed upgrade introduces optical and PHY compatibility checks. The revised requirement is: The link upgrades to a new 25G port pair that requires matching optics. The appropriate action is: Validate transceiver and physical signaling compatibility before activation.

Incorrect Answers

A:

Name-resolution cache times do not fix physical negotiation issues. It remains inappropriate in the revised context.

B:

This is the original control. Duplex mismatch causes collisions or errors and poor throughput on affected links. It does not directly satisfy the revised requirement: The link upgrades to a new 25G port pair that requires matching optics.

C:

Both ports show expected duplex and the error counters stop increasing. The current requirement is: The link upgrades to a new 25G port pair that requires matching optics.

Question 257

A storage fabric requires 9000-byte frames but an intermediate switch only allows the standard MTU. Which action MOST directly meets the stated networking requirement?

  1. Inspect root bridge IDs and STP port roles across the affected topology.
  2. Set a consistent supported jumbo-frame MTU along the entire intended path.
  3. Configure 9000 on the endpoints only and ignore transit devices.
  4. Use path MTU discovery and conservative packet sizing.

Explanation

Correct Answer

B:

Any smaller-MTU hop may drop oversized frames or cause fragmentation-related issues. This specifically resolves: A storage fabric requires 9000-byte frames but an intermediate switch only allows the standard MTU.

Incorrect Answers

A:

This addresses another problem in objective 2.2: A network wants to discover which switch became spanning-tree root after a maintenance change.

C:

End host MTU cannot force an intermediate link to accept larger frames. The suggested approach is: Configure 9000 on the endpoints only and ignore transit devices.

D:

This action responds to a later condition: The service moves to an internet path with unknown intermediate MTU. Internet transit cannot assume jumbo-frame support.

Question 258

A storage fabric requires 9000-byte frames but an intermediate switch only allows the standard MTU. A colleague instead suggests: Configure 9000 on the endpoints only and ignore transit devices. Which finding MOST specifically explains why that suggestion is unsuitable?

  1. End host MTU cannot force an intermediate link to accept larger frames.
  2. Internet transit cannot assume jumbo-frame support.
  3. IP hop tracing does not identify layer-2 STP election details.
  4. Any smaller-MTU hop may drop oversized frames or cause fragmentation-related issues.

Explanation

Correct Answer

A:

End host MTU cannot force an intermediate link to accept larger frames. This flaw directly concerns the proposed action: Configure 9000 on the endpoints only and ignore transit devices.

Incorrect Answers

B:

This rationale belongs to a later changed condition: The service moves to an internet path with unknown intermediate MTU.

C:

This flaw concerns a different case in objective 2.2: A network wants to discover which switch became spanning-tree root after a maintenance change. The current rejected proposal is: Configure 9000 on the endpoints only and ignore transit devices.

D:

This explains why the recommended control works: Set a consistent supported jumbo-frame MTU along the entire intended path.

Question 259

A storage fabric requires 9000-byte frames but an intermediate switch only allows the standard MTU. After applying the solution 'Set a consistent supported jumbo-frame MTU along the entire intended path.', which observation MOST directly proves that the requirement was met?

  1. All switches report the intended root and appropriate designated or alternate roles.
  2. End-to-end jumbo packet testing succeeds without unexpected drops.
  3. Approval is recorded for 'Set a consistent supported jumbo-frame MTU along the entire intended path.' but no operational validation is performed.
  4. The MAC table and address allocation show the client in VLAN 30.

Explanation

Correct Answer

B:

End-to-end jumbo packet testing succeeds without unexpected drops. It tests the intended outcome because any smaller-mtu hop may drop oversized frames or cause fragmentation-related issues.

Incorrect Answers

A:

This observation is for a different condition: A network wants to discover which switch became spanning-tree root after a maintenance change. It does not directly test the target outcome: A storage fabric requires 9000-byte frames but an intermediate switch only allows the standard MTU.

C:

Approval alone does not demonstrate operating effectiveness. The missing direct test is: End-to-end jumbo packet testing succeeds without unexpected drops.

D:

This test addresses a separate problem: An employee port belongs in VLAN 30 but the switch currently places it in VLAN 10.

Question 260

The original case was: A storage fabric requires 9000-byte frames but an intermediate switch only allows the standard MTU. The requirement then changes: The service moves to an internet path with unknown intermediate MTU. Which revised action BEST meets this new condition?

  1. Configure 9000 on the endpoints only and ignore transit devices.
  2. Use path MTU discovery and conservative packet sizing.
  3. Set a consistent supported jumbo-frame MTU along the entire intended path.
  4. End-to-end jumbo packet testing succeeds without unexpected drops.

Explanation

Correct Answer

B:

Internet transit cannot assume jumbo-frame support. The revised requirement is: The service moves to an internet path with unknown intermediate MTU. The appropriate action is: Use path MTU discovery and conservative packet sizing.

Incorrect Answers

A:

End host MTU cannot force an intermediate link to accept larger frames. It remains inappropriate in the revised context.

C:

This is the original control. Any smaller-MTU hop may drop oversized frames or cause fragmentation-related issues. It does not directly satisfy the revised requirement: The service moves to an internet path with unknown intermediate MTU.

D:

End-to-end jumbo packet testing succeeds without unexpected drops. The current requirement is: The service moves to an internet path with unknown intermediate MTU.

CompTIA Network+ (N10-009) Practice Tests