CompTIA N10-009 Practice Test 10
Question 90
An access switch needs a 10-gigabit uplink over a short multimode fiber run inside a building. A colleague instead suggests: Install incompatible long-wavelength modules without checking fiber and port support. Which finding MOST specifically explains why that suggestion is unsuitable?
- Transceiver protocol and fiber type must match link budget and port capability.
- Incompatible modules or wavelengths may prevent the optical link from forming.
- Longer distances change the optical power and fiber requirements.
- RJ11 wiring and interface specifications do not support a 25G server uplink.
Explanation
Correct Answer
B:Incompatible modules or wavelengths may prevent the optical link from forming. This flaw directly concerns the proposed action: Install incompatible long-wavelength modules without checking fiber and port support.
Incorrect Answers
A:This explains why the recommended control works: Choose compatible 10G short-range optical transceivers and multimode cabling.
C:This rationale belongs to a later changed condition: The planned uplink becomes a longer campus backbone link.
D:This flaw concerns a different case in objective 1.5: A server and switch share a rack and need a supported 25-gigabit copper interconnect only two meters long. The current rejected proposal is: Install incompatible long-wavelength modules without checking fiber and port support.
Question 91
An access switch needs a 10-gigabit uplink over a short multimode fiber run inside a building. After applying the solution 'Choose compatible 10G short-range optical transceivers and multimode cabling.', which observation MOST directly proves that the requirement was met?
- The negotiated rate and error counters match the supported DAC link characteristics.
- Approval is recorded for 'Choose compatible 10G short-range optical transceivers and multimode cabling.' but no operational validation is performed.
- Both ends establish the intended rate with acceptable optical levels and CRC counts.
- Inventory and interface diagnostics agree on module identity, speed and optical status.
Explanation
Correct Answer
C:Both ends establish the intended rate with acceptable optical levels and CRC counts. It tests the intended outcome because transceiver protocol and fiber type must match link budget and port capability.
Incorrect Answers
A:This observation is for a different condition: A server and switch share a rack and need a supported 25-gigabit copper interconnect only two meters long. It does not directly test the target outcome: An access switch needs a 10-gigabit uplink over a short multimode fiber run inside a building.
B:The missing direct test is: Both ends establish the intended rate with acceptable optical levels and CRC counts.
D:This test addresses a separate problem: A 100-gigabit backbone upgrade requires the correct optical module form factor for high-density aggregation ports.
Question 92
The original case was: An access switch needs a 10-gigabit uplink over a short multimode fiber run inside a building. The requirement then changes: The planned uplink becomes a longer campus backbone link. Which revised action BEST meets this new condition?
- Both ends establish the intended rate with acceptable optical levels and CRC counts.
- Choose compatible 10G short-range optical transceivers and multimode cabling.
- Recalculate distance and deploy compatible single-mode long-reach optics when needed.
- Install incompatible long-wavelength modules without checking fiber and port support.
Explanation
Correct Answer
C:Longer distances change the optical power and fiber requirements. The revised requirement is: The planned uplink becomes a longer campus backbone link. The appropriate action is: Recalculate distance and deploy compatible single-mode long-reach optics when needed.
Incorrect Answers
A:Both ends establish the intended rate with acceptable optical levels and CRC counts. The current requirement is: The planned uplink becomes a longer campus backbone link.
B:This is the original control. Transceiver protocol and fiber type must match link budget and port capability. It does not directly satisfy the revised requirement: The planned uplink becomes a longer campus backbone link.
D:Incompatible modules or wavelengths may prevent the optical link from forming. It remains inappropriate in the revised context.
Question 93
New cabling must run through an air-handling ceiling subject to local fire codes. Which action MOST directly meets the stated networking requirement?
- Select environmentally rated outdoor cabling and appropriate surge protection.
- Use plenum-rated cable appropriate to the installation and applicable local requirements.
- Install non-plenum consumer cable solely because its data rating is high.
- Use compatible QSFP-class modules and verify lane count, reach and connector type.
Explanation
Correct Answer
B:Jacket materials must meet fire and smoke requirements for designated plenum spaces. This specifically resolves: New cabling must run through an air-handling ceiling subject to local fire codes.
Incorrect Answers
A:This action responds to a later condition: The installation shifts to a wet outdoor conduit and must resist moisture. Outdoor physical exposure requires water and environmental protection beyond plenum labeling.
C:Data category alone does not satisfy building fire-safety requirements. The suggested approach is: Install non-plenum consumer cable solely because its data rating is high.
D:This addresses another problem in objective 1.5: A 100-gigabit backbone upgrade requires the correct optical module form factor for high-density aggregation ports.
Question 94
New cabling must run through an air-handling ceiling subject to local fire codes. A colleague instead suggests: Install non-plenum consumer cable solely because its data rating is high. Which finding MOST specifically explains why that suggestion is unsuitable?
- Outdoor physical exposure requires water and environmental protection beyond plenum labeling.
- Data category alone does not satisfy building fire-safety requirements.
- Port form factor and electrical compatibility cannot be assumed interchangeable.
- Jacket materials must meet fire and smoke requirements for designated plenum spaces.
Explanation
Correct Answer
B:Data category alone does not satisfy building fire-safety requirements. This flaw directly concerns the proposed action: Install non-plenum consumer cable solely because its data rating is high.
Incorrect Answers
A:This rationale belongs to a later changed condition: The installation shifts to a wet outdoor conduit and must resist moisture.
C:This flaw concerns a different case in objective 1.5: A 100-gigabit backbone upgrade requires the correct optical module form factor for high-density aggregation ports. The current rejected proposal is: Install non-plenum consumer cable solely because its data rating is high.
D:This explains why the recommended control works: Use plenum-rated cable appropriate to the installation and applicable local requirements.
Question 95
New cabling must run through an air-handling ceiling subject to local fire codes. After applying the solution 'Use plenum-rated cable appropriate to the installation and applicable local requirements.', which observation MOST directly proves that the requirement was met?
- Installation inspection confirms required markings and compliant cable routing.
- Inventory and interface diagnostics agree on module identity, speed and optical status.
- Optical measurements and traffic tests meet expected receive power and error thresholds.
- Approval is recorded for 'Use plenum-rated cable appropriate to the installation and applicable local requirements.' but no operational validation is performed.
Explanation
Correct Answer
A:Installation inspection confirms required markings and compliant cable routing. It tests the intended outcome because jacket materials must meet fire and smoke requirements for designated plenum spaces.
Incorrect Answers
B:This observation is for a different condition: A 100-gigabit backbone upgrade requires the correct optical module form factor for high-density aggregation ports. It does not directly test the target outcome: New cabling must run through an air-handling ceiling subject to local fire codes.
C:This test addresses a separate problem: A carrier link crosses several kilometers between buildings, beyond the usual reach of multimode optics.
D:The missing direct test is: Installation inspection confirms required markings and compliant cable routing.
Question 96
The original case was: New cabling must run through an air-handling ceiling subject to local fire codes. The requirement then changes: The installation shifts to a wet outdoor conduit and must resist moisture. Which revised action BEST meets this new condition?
- Install non-plenum consumer cable solely because its data rating is high.
- Select environmentally rated outdoor cabling and appropriate surge protection.
- Use plenum-rated cable appropriate to the installation and applicable local requirements.
- Installation inspection confirms required markings and compliant cable routing.
Explanation
Correct Answer
B:Outdoor physical exposure requires water and environmental protection beyond plenum labeling. The revised requirement is: The installation shifts to a wet outdoor conduit and must resist moisture. The appropriate action is: Select environmentally rated outdoor cabling and appropriate surge protection.
Incorrect Answers
A:Data category alone does not satisfy building fire-safety requirements. It remains inappropriate in the revised context.
C:This is the original control. Jacket materials must meet fire and smoke requirements for designated plenum spaces. It does not directly satisfy the revised requirement: The installation shifts to a wet outdoor conduit and must resist moisture.
D:Installation inspection confirms required markings and compliant cable routing. The current requirement is: The installation shifts to a wet outdoor conduit and must resist moisture.
Question 97
A server and switch share a rack and need a supported 25-gigabit copper interconnect only two meters long. Which action MOST directly meets the stated networking requirement?
- Replace DAC with distance-appropriate fiber transceivers and tested fiber plant.
- Use an RJ11 telephone patch cord as a 25G Ethernet uplink.
- Choose single-mode fiber and compatible long-distance transceivers within optical budget.
- Use a vendor-supported 25G SFP28 direct attach cable meeting host port specifications.
Explanation
Correct Answer
D:Short twinax DAC links can avoid optical modules for supported short distances. This specifically resolves: A server and switch share a rack and need a supported 25-gigabit copper interconnect only two meters long.
Incorrect Answers
A:This action responds to a later condition: The server moves to a different building hundreds of meters away. DAC range is too short for inter-building connectivity.
B:RJ11 wiring and interface specifications do not support a 25G server uplink. The suggested approach is: Use an RJ11 telephone patch cord as a 25G Ethernet uplink.
C:This addresses another problem in objective 1.5: A carrier link crosses several kilometers between buildings, beyond the usual reach of multimode optics.
Question 98
A server and switch share a rack and need a supported 25-gigabit copper interconnect only two meters long. A colleague instead suggests: Use an RJ11 telephone patch cord as a 25G Ethernet uplink. Which finding MOST specifically explains why that suggestion is unsuitable?
- Short twinax DAC links can avoid optical modules for supported short distances.
- Mismatched fiber optics and reach specifications can prevent reliable links.
- DAC range is too short for inter-building connectivity.
- RJ11 wiring and interface specifications do not support a 25G server uplink.
Explanation
Correct Answer
D:RJ11 wiring and interface specifications do not support a 25G server uplink. This flaw directly concerns the proposed action: Use an RJ11 telephone patch cord as a 25G Ethernet uplink.
Incorrect Answers
A:This explains why the recommended control works: Use a vendor-supported 25G SFP28 direct attach cable meeting host port specifications.
B:This flaw concerns a different case in objective 1.5: A carrier link crosses several kilometers between buildings, beyond the usual reach of multimode optics. The current rejected proposal is: Use an RJ11 telephone patch cord as a 25G Ethernet uplink.
C:This rationale belongs to a later changed condition: The server moves to a different building hundreds of meters away.
Question 99
A server and switch share a rack and need a supported 25-gigabit copper interconnect only two meters long. After applying the solution 'Use a vendor-supported 25G SFP28 direct attach cable meeting host port specifications.', which observation MOST directly proves that the requirement was met?
- Approval is recorded for 'Use a vendor-supported 25G SFP28 direct attach cable meeting host port specifications.' but no operational validation is performed.
- The negotiated rate and error counters match the supported DAC link characteristics.
- Both ends establish the intended rate with acceptable optical levels and CRC counts.
- Optical measurements and traffic tests meet expected receive power and error thresholds.
Explanation
Correct Answer
B:The negotiated rate and error counters match the supported DAC link characteristics. It tests the intended outcome because short twinax dac links can avoid optical modules for supported short distances.
Incorrect Answers
A:The missing direct test is: The negotiated rate and error counters match the supported DAC link characteristics.
C:This test addresses a separate problem: An access switch needs a 10-gigabit uplink over a short multimode fiber run inside a building.
D:This observation is for a different condition: A carrier link crosses several kilometers between buildings, beyond the usual reach of multimode optics. It does not directly test the target outcome: A server and switch share a rack and need a supported 25-gigabit copper interconnect only two meters long.
Question 100
A server and switch share a rack and need a supported 25-gigabit copper interconnect only two meters long. Which THREE entries correctly identify the applicable control, its technical principle, and a direct validation observation? (Select THREE.)
- Choose single-mode fiber and compatible long-distance transceivers within optical budget.
- Use an RJ11 telephone patch cord as a 25G Ethernet uplink.
- Short twinax DAC links can avoid optical modules for supported short distances.
- Replace DAC with distance-appropriate fiber transceivers and tested fiber plant.
- Use a vendor-supported 25G SFP28 direct attach cable meeting host port specifications.
- The negotiated rate and error counters match the supported DAC link characteristics.
Explanation
Correct Answers
C:Correct principle. Short twinax DAC links can avoid optical modules for supported short distances. This is the justification for the selected network control: Use a vendor-supported 25G SFP28 direct attach cable meeting host port specifications.
E:Correct control. Short twinax DAC links can avoid optical modules for supported short distances. It is the recommended implementation for this case.
F:Correct validation. The negotiated rate and error counters match the supported DAC link characteristics. This is the directly measurable result of the control.
Incorrect Answers
A:This is another scenario's control in the same domain: A carrier link crosses several kilometers between buildings, beyond the usual reach of multimode optics. It is not the best action for this case.
B:This control is invalid here. RJ11 wiring and interface specifications do not support a 25G server uplink. It does not meet the specified requirement.
D:This belongs to the changed condition, not the current three-part answer: The server moves to a different building hundreds of meters away. DAC range is too short for inter-building connectivity.